The LCD-80TM
Liquid Crystal Display
for the Notifier AM2020/AFP1010 and AFP-200
Fire Alarm Control Panels
Document 50182
07/31/97 Revision: A
P/N 50182:A3 ECN 96-424
Installation Precautions - Adherence to the following will aid in problem-free installation with long-term reliability:
WARNING - Several different sources of power can be connected to the fire alarm Like all solid state electronic devices, this system may operate erratically or can
control panel. Disconnect all sources of power before servicing. Control unit and be damaged when subjected to lightning induced transients. Although no system is
associated equipment may be damaged by removing and/or inserting cards, completely immune from lightning transients and interferences, proper grounding will
modules, or interconnecting cables while the unit is energized. Do not attempt to reduce susceptibility. Overhead or outside aerial wiring is not recommended, due to
install, service, or operate this unit until this manual is read and understood. an increased susceptibility to nearby lightning strikes. Consult with the Technical
Services Department if any problems are anticipated or encountered.
CAUTION - System Reacceptance Test after Software Changes: To ensure
proper system operation, this product must be tested in accordance with NFPA 72- Disconnect AC power and batteries prior to removing or inserting circuit boards.
1993 Chapter 7 after any programming operation or change in site-specific software. Failure to do so can damage circuits.
Reacceptance testing is required after any change, addition or deletion of system
components, or after any modification, repair or adjustment to system hardware or Remove all electronic assemblies prior to any drilling, filing, reaming, or punching
wiring. of the enclosure. When possible, make all cable entries from the sides or rear.
Before making modifications, verify that they will not interfere with battery,
All components, circuits, system operations, or software functions known to be transformer, and printed circuit board location.
affected by a change must be 100% tested. In addition, to ensure that other
operations are not inadvertently affected, at least 10% of initiating devices that are Do not tighten screw terminals more than 9 in-lbs. Over tightening may damage
not directly affected by the change, up to a maximum of 50 devices, must also be threads, resulting in reduced terminal contact pressure and difficulty with screw
tested and proper system operation verified. terminal removal.
This system meets NFPA requirements for operation at 0-49O C/32-120 O F This system contains static-sensitive components. Always ground yourself with a
and at a relative humidity of 85% RH (non-condensing) at 30 O C/86 O F. proper wrist strap before handling any circuits so that static charges are removed
However, the useful life of the system's standby batteries and the electronic from the body. Use static suppressive packaging to protect electronic assemblies
components may be adversely affected by extreme temperature ranges and removed from the unit.
humidity. Therefore, it is recommended that this system and its peripherals be
installed in an environment with a nominal room temperature of 15-27O C/60-80 O Follow the instructions in the installation, operating, and programming manuals.
F. These instructions must be followed to avoid damage to the control panel and
associated equipment. FACP operation and reliability depend upon proper
Verify that wire sizes are adequate for all initiating and indicating device loops. installation.
Most devices cannot tolerate more than a 10% I.R. drop from the specified device
voltage.
An automatic fire alarm system - typically made up of smoke detectors, heat Audible warning devices such as bells may not alert people if these devices are
detectors, manual pull stations, audible warning devices, and a fire alarm control located on the other side of closed or partly open doors or are located on another
with remote notification capability can provide early warning of a developing fire. floor of a building.
Such a system, however, does not assure protection against property damage or
loss of life resulting from a fire. A fire alarm system will not operate without any electrical power. If AC power fails,
the system will operate from standby batteries only for a specified time.
Any fire alarm system may fail for a variety of reasons:
Rate-of-Rise heat detectors may be subject to reduced sensitivity over time. For
Smoke detectors may not sense fire where smoke cannot reach the detectors such this reason, the rate-of-rise feature of each detector should be tested at least once
as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke per year by a qualified fire protection specialist.
detectors also may not sense a fire on another level or floor of a building. A second
floor detector, for example, may not sense a first floor or basement fire. Further- Equipment used in the system may not be technically compatible with the control.
more, all types of smoke detectors - both ionization and photoelectric types, have It is essential to use only equipment listed for service with your control panel.
sensing limitations. No type of smoke detector can sense every kind of fire caused
by carelessness and safety hazards like smoking in bed, violent explosions, Telephone lines needed to transmit alarm signals from a premise to a central
escaping gas, improper storage of flammable materials, overloaded electrical monitoring station may be out of service or temporarily disabled.
circuits, children playing with matches, or arson.
The most common cause of fire alarm malfunctions, however, is inadequate
IMPORTANT! Smoke detectors must be installed in the same room as the maintenance. All devices and system wiring should be tested and maintained by
control panel and in rooms used by the system for the connection of alarm professional fire alarm installers following written procedures supplied with each
transmission wiring, communications, signaling, and/or power. If detectors are device. System inspection and testing should be scheduled monthly or as required
not so located, a developing fire may damage the alarm system, crippling its by National and/or local fire codes. Adequate written records of all inspections should
ability to report a fire. be kept.
FCC Warning
WARNING: This equipment generates, uses, and can radiate radio frequency Canadian Requirements
energy and if not installed and used in accordance with the instruction manual, may This digital apparatus does not exceed the Class A limits for radiation noise
cause interference to radio communications. It has been tested and found to comply emissions from digital apparatus set out in the Radio Interference Regulations of the
with the limits for class A computing device pursuant to Subpart B of Part 15 of FCC Canadian Department of Communications.
Rules, which is designed to provide reasonable protection against such interference
when operated in a commercial environment. Operation of this equipment in a Le present appareil numerique n'emet pas de bruits radioelectriques depassant les
residential area is likely to cause interference, in which case the user will be required limites applicables aux appareils numeriques de la classe A prescrites dans le
to correct the interference at his own expense. Reglement sur le brouillage radioelectrique edicte par le ministere des Communica-
tions du Canada.
CCM-1
NOTES:
EIA-485: Maximum of 6000 feet between units.
Optional CRT Display Monitor connection to CCM-1. One Between each LCD-80TM are four wires: A twisted-shielded pair
max - requires programming at the AM2020/AFP1010. If a for data communications and an open pair for 24 VDC power.
CRT is not used, connect the LCD-80TM directly to DIA The return circuit only requires two wires for data communication.
TB1.
AM2020/AFP1010 Note: The EIA-485 interface used for the LCD-80TM should not be confused with the EIA-485
circuit used for the ACS interface. The CCM-1 Convertor Module converts the EIA-232 Terminal Interface from the
SIB-2048 into the EIA-485 standard required by the LCD-80TM. The DIA-2020N can support LCD-80TMs in terminal
mode without the need for a CCM-1 converter module (if a CRT is not being used).
Display Patterns
The LCD-80TM displays directly the information from the AFP-200 or AM2020/AFP1010 terminal interface without
alteration.
Note: The ALARMS PENDING, TROUBLES PENDING, Alarm Count and Trouble Count information will not be
displayed on the LCD-80TM.
If the LCD-80TM fails to receive communications from the panel for a period of over one minute, it will activate its local
sounder and display the following message:
C O M M U NI C A T I O N S F A I L
Status Button
The LCD-80TM, when used with the AM2020/AFP1010 will keep a count of alarms in the system (number of alarm
messages, minus alarm clear messages, since the last ALL SYSTEMS NORMAL message). When this key is pressed
the alarm count is displayed in place of the time/date for 10 seconds.
Contrast Adjust
Repeatedly press this switch until the display's contrast is acceptable.
Silence Button
When the SILENCE switch is pressed on the front panel, the LCD-80TM sends
a Signal Silence command to the control panel, emulating the CRT terminal.
Reset Button
When the System Reset switch is pressed on the front panel, the LCD-80TM
sends a Reset command to the control panel, emulating the CRT terminal.
Note: If Acknowledge, Silence, and Reset switches are enabled for system control, access security must be provided by
mounting the LCD-80TM in a locked Fire Alarm Cabinet, or Annunciator Backbox model ABF-1/1D or ABS-1T with AKS-
1 key switch option.
LCD-80TM
( - ) EIA-485
To next LCD-80TM
(+) EIA-485
Notes:
1) All connections are power-limited and supervised. Refer to Appendix A for shield
termination instructions.
2) A maximum of 32 LCD-80TMs may be connected to this circuit.
3) 6000 feet maximum distance (@ 16 AWG) between the panel and the first or last LCD-80TM and between each additional LCD-
80TM.
4) Use overall foil/braided-shield twisted pair cable suitable for EIA-485 applications (refer to Appendix A for shield termination
information).
6) Each LCD-80TM must have R-120 resistors installed across the in and out terminals as shown.
CCM-1 DIA
EIA-485 AFP-200
(AM2020/AFP1010) (AM2020/AFP1010)
LCD-80TM
From Main Power Supply
(refer to table below)
( - ) Common
MPS-24A AFP-200
Note: All enclosures, including the FACP backbox, must be connected to earth ground! Never use the shield for
grounding purposes.
Terminate the EIA-485 shields at both the Out and Return ends of the CCM-1 (or the DIA-1010 or DIA-2020 Display
Interface Board if employing that option), at either the cabinet (when not in conduit) or at system common (when in
conduit) as outlined below:
When the EIA-485 shield is not in conduit: At each respective LCD-80TM enclosure (except the first on the
loop), terminate the shield coming in from the previous LCD-80TM at the outside of the cabinet backbox (earth
ground). Let the outgoing (to next LCD-80TM) shield float (no connection). Shield termination between LCD-
80TMs can only occur at the receiving end - the end connected to P1 Terminals 2 and 4. For the first LCD-80TM
on the loop, let the shield coming in from the CCM-1 or DIA float.
When the EIA-485 shield is in conduit: At each respective LCD-80TM enclosure (except the first on the loop),
terminate the shield coming in from the previous LCD-80TM at system common. Let the shield going out to next
LCD-80TM shield float (no connection). Shield termination between LCD-80TMs can only occur at the receiving
end - the end connected to LCD-80TM P1 Terminals 2 and 4. For the first LCD-80TM on the loop, let the shield
coming in from the CCM-1 or DIA float.
NOTIFIER® warrants its products to be free from defects in materials and workmanship
for eighteen (18) months from the date of manufacture, under normal use and service.
Products are date stamped at time of manufacture. The sole and exclusive obligation
of NOTIFIER® is to repair or replace, at its option, free of charge for parts and labor,
any part which is defective in materials or workmanship under normal use and service.
For products not under NOTIFIER® manufacturing date-stamp control, the warranty
is eighteen (18) months from date of original purchase by NOTIFIER®'s distributor
unless the installation instructions or catalog sets forth a shorter period, in which
case the shorter period shall apply. This warranty is void if the product is altered,
repaired or serviced by anyone other than NOTIFIER® or its authorized distributors or
if there is a failure to maintain the products and systems in which they operate in a
proper and workable manner. In case of defect, secure a Return Material Authorization
form from our customer service department. Return product, transportation prepaid,
to NOTIFIER®, 12 Clintonville Road, Northford, Connecticut 06472-1653.
This writing constitutes the only warranty made by NOTIFIER® with respect to its
products. NOTIFIER® does not represent that its products will prevent any loss by
fire or otherwise, or that its products will in all cases provide the protection for which
they are installed or intended. Buyer acknowledges that NOTIFIER® is not an insurer
and assumes no risk for loss or damages or the cost of any inconvenience,
transportation, damage, misuse, abuse, accident or similar incident.
This warranty replaces all previous warranties and is the only warranty made by
NOTIFIER®. No increase or alteration, written or verbal, of the obligation of this warranty
is authorized.