INSTALLATION MANUAL

Wall-mounted Type

Thank you very much for purchasing our air conditioner,


please read this manual carefully and keep it for future reference.
When installing the unit in a small room, take measures
against to keep refrigerant concentration from exceeding
allowable safety limits in the event of refrigerant leakage.
Contact the place of purchase for more information.
Excessive refrigerant in a closed ambient can lead to oxygen
deficiency.

Use the attached accessories parts and specified parts


for installation.
otherwise, it will cause the set to fall, water leakage,
electrical shock fire.

Install at a strong and firm location which is able to


withstand the set' s weight.
If the strength is not enough or installation is not properly
done, the set will drop to cause injury.

The appliance must be installed 2.5m above floor.

The appliance shall not be installed in the laundry.

1. PRECAUTIONS Before obtaining access to terminals, all supply circuits


must be disconnected.

The appliance must be positioned so that the plug is


Be sure to be in conformity with the local, national and accessible.
international laws and regulations.
The enclosure of the appliance shall be marked by word,
Read "PRECAUTIONS" carefully before installation. or by symbols, with the direction of the fluid flow.

The following precautions include important safty items. For electrical work, follow the local national wiring
Observe them and never forget. standard, regulation and this installation instructions. An
independent circuit and single outlet must be used.
Keep this manual with the owner's manual in a handy place If electrical circuit capacity is not enough or defect in
for future reference. electrical work, it will cause electrical shock fire.

Installation must be performed in accordance with the Use the specified cable and connect tightly and clamp
requirement of NEC and CEC by authorized personnel only. the cable so that no external force will be acted on the
terminal.
If connection or fixing is not perfect, it will cause heat-up or
fire at the connection.
The safty precautions listed here are divided into two categories. In
either case, important safty information is listed which must be read Wiring routing must be properly arranged so that control
carefully. board cover is fixed properly.
If control board cover is not fixed perfectly, it will cause
WARNING heat-up at connection point of terminal, fire or electrical
shock.
Failure to observe a warning may result in death.
If the supply cord is damaged, it must be replaced by the
CAUTION manufacture or its sevice agent or similarly qualifued
Failure to observe a caution may result in injury or damage person in order to avoid a hazard.
to the equipment.
An all-pole disconnection switch having a cintract
After completing the installation, make sure that the unit operates separation of at least 3mm in a poles should be
properly during the start-up operation. Please instruct the customer connected in fixed wiring.
on how to operate the unit and keep it maintained.Also, inform
customers that they should store this installation manual along with When carrying out piping connection, take care not to let
the owner's manual for future reference. air substances go into refrigeration cycle.
Otherwise, it will cause lower capacity, abnormal high
pressure in the refrigeration cycle, explosion and injury.
WARNING Do not modify the length of the power supply cord or use
Be sure only trained and qualified service personnel to of extension cord, and do not share the single outlet with
install, repair or service the equipment. other electrical appliances.
Improper installation, repair, and maintenance may result in Otherwise, it will cause fire or electrical shock.
electric shocks, short-circuit, leaks, fire or other damage to
the equipment. Carry out the specified installation work after taking into
account strong winds, typhoons or earthquakes.
Install according to this installation instructions strictly. Improper installation work may result in the equipment falling
If installation is defective, it will cause water leakage, electric and causing accidents.
shocks, fire.

installation manual

1
If the refrigerant leaks during installation, ventilate the There is strong electromagnetic wave existing.
area immediately.
There are inflammable materials or gas.
Toxic gas may be produced if the refrigerant comes into the
place contacting with fire. There is acid or alkaline liquid evaporating.

After completing the installation work, check that the The appliance shall not be installed in the laundry.
refrigerant does not leak. Avoid installing it in a narrow sapce which has a high
Toxic gas may be produced if the refrigerant leaks into the requirement to noise.
room and comes into contact with a source of fire, such as a
fan heater, stove or cooker. Other special conditions.

The appliance shall be installed in accordance with


national wiring regulations.

The power cord type designation is H05RN-R/H07RN-F or


above. 2. INSTALLATION INFORMATION

To install properly, please read this "installation manual" at


first.

CAUTION The air conditioner must be installed by qualified persons.

When installing the indoor unit or its tubing, please follow


Ground the air conditioner.
this manual as strictly as possible.
Do not connect the ground wire to gas or water pipes,
lightning rod or a telephone ground wire.Incomplete
If the air conditioner is installed on a metal part of the
grounding may result in electric shocks.
building, it must be electrically insulated according to the
relevant standards to electrical appliances.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in
When all the installation work is finished, please turn on the
electric shocks.
power only after a thorough check.
Connect the outdoor unit wires , then connect the indoor
1.5kW model only can be connected to V4 Plus Series and
unit wires.
Inverter Mini VRF outdoor unit.The outdoor unit specific
You are not allow to connect the air conditioner with the
model please contact the local dealer or technical support
power source until w(including
engineer.
iring and piping the air conditioner is done.
Regret for no further announcement if there is any change
While following the instructions in this installation
of this manual caused by product improvement.
manual, install drain piping in order to ensure proper
drainage and insulate piping in order to prevent
condensation.
Improper drain piping may result in water leakage and
property damage. INSTALLATION ORDER
Select the location;
Install the indoor and outdoor units, power supply wiring
and connecting wires at least 1 meter away from
Install the indoor unit;
televisions or radios in order to prevent image
interference or noise.
Install the outdoor unit;
Depending on the radio waves, a distance of 1 meter may not
be sufficient enough to eliminate the noise.
Install the connecting pipe ;
The appliance is not intended for use by young children
Connect the drain pipe;
or infirm persons without supervision.
Wiring;
Young children should be supervised to ensure that they
do not play with the appliance.
Test operation.
Don't install the air conditioner in the following locations:

There is petrolatum existing.

There is salty air surrounding (near the coast).

There is caustic gas (the sulfide, for example) existing in


the air (near a hot spring).

The Volt vibrates violently (in the factories).

In buses or cabinets.

In kitchen where it is full of oil gas.

installation manual

2
3. ATTACHED FITTINGS
Please check whether the following fittings are of full scope. If there are some spare fittings , please restore them carefully.

NAME SHAPE QUANTITY FUNCTION

1. Remote controller manual 1

2. Screw ST3.9x25 for installation board 8 Secure the installation board

3. Plastic expanded tube 8

4. Wrapping tape 1

5.Drain pipe 1

6. Wall conduit cover 1

7. Remote controller 1
(including operation manual)

8. Frame 1 Hold the remote controller

9. Mounting screw(ST2.9 10-C-H) 2 Insulation Holder for remote controller

10. Alkaline dry batteries (AM4) 2

11. Owner's manual 1 Not attach in several unit

12. Installation manual 1 This manual

The indoor unit which at the terminal of


13. Network matching wire 1 communication system should connect a
impedance between port P and port Q.

14.Copper nut 1 Connect piping

Cautions on remote controller installation:

Never throw or beat the controller. Mounting screw B


ST2.9x10-C-H
Before installation, operate the remote controller to determine its location in a
reception range.

Keep the remote controller at least 1m apart from the nearest TV set or stereo
equipment. (it is necessary to prevent image disturbances or noise interferences.)

Do not install the remote controller in a place exposed to direct sunlight or close to a
heating source, such as a stove. Remote controller
holder
Note that the positive and negative poles are right positions when loading batteries. Remote
controller
This manual is subject to changes due to technological improvement without further Fig.3-1
notices.

installation manual

3
4. INSPECTING AND HANDLING THE UNIT
At delivery, the package should be checked and any damage should 5.2 Drilling A Hole and Mounting Installation
be reported immediately to the carrier claims agent.
Board
When handling the unit, take into account the following:
Installation Board and Its Direction (unit: mm)
1 Fragile, handle the unit with care.

Keep the unit upright in order to avoid compressor


1.5\2.2\2.8\3.6 kW type
damage.
mounting board of indoor unit
2 Choose on before hand the path along which the unit is to be
brought in. 462

57
3 Move this unit as originally package as possible.

290
4 When lifting the unit , always use protectors to prevent belt
damage and pay attention to the position of the unit’s centre
of gravity. 712
915
the shape of indoor unit Fig.5-1

5. INDOOR UNIT INSTALLATION 4.5\5.6\7.1 kW type


5.1 Installation place mounting board of indoor unit

The indoor unit should be installed in a location that meets 730

65
the following reauirements:

Avoid installing it in a narrow sapce which has a high

315
requirement to noise.
The ceiling is horizontal, and its structure can endure the
weight of the indoor unit. 794
1070
The outlet and the inlet are not impeded, and the
influence of external air is the least. the shape of indoor unit Fig.5-2
The air flow can reach throughout the room.
The connecting pipe and drainpipe could be extracted out
1 Fix the installation board.
easily.
There is no direct radiation from heaters. Install the installation board horizontally on structural parts in
the wall with the spaces provided around the plate.
Don't install it in a place whose air contains much salt. If
this can't be avoided, choose a anticorrosive model. In case of brick, concrete or similar type walls,make 5mmdia,
holes in the wall. Insert clip anchors for appropriate mounting
screws.

CAUTION Fix the installation board on the wall.


Installing the equipment in any of the following places may lead to Right installation
faults of the equipment (if that is inevitable, consult the supplier):

A. The site contains mineral oils such as cutting lubricant.


B. Seaside where the air contains much salt.
C. Hotpring area where corrosive gases exist, e.g., sulfide gas.
mounting board
D. Factories where the supply voltage fluctuates seriously. of indoor unit
E. Inside a car or cabin.
F. Place like kitchen where oil permeates.
G. Place where strong electromagnetic waves exist.
H. Place where flammable gases or materials exist.
I. Place where acid or alkali gases evaporate. horizontal line
J. Other special environments.

Fig.5-3

installation manual

4
False installation When connection extension drain hose,insulate the
connecting part of extension drain hose with a shield pipe

mounting board Wall


of indoor unit Shield pipe

horizontal line
Extension drainhose
Drain hose
Fig.5-6

2 Connection pipe

Left piping
mounting board
of indoor unit
Left back piping

Right piping
Right back piping
Fig.5-7
horizontal line

Fig.5-4 For the left-hand and rear-left-hand piping,install the piping as


shown. Bend the conn-ective pipe to be laid at 43mm height or
less from the wall.

Indoor unit outline


2 Drilling a hole. Connective pipe

Determine the pipe hole position using the installation


board, and drill the pipehole (N95mm) so it slants slightly
downward.

43
. .. .. .
Always use a wall hole conduit when piercing metal lath,
. .......
ply wood or metal plate.
........................................................................................ ............
. .. . .. . ..... ... .. .. .. . .
Fig.5-8

5.3 Connective Pipe and Drainage Installation Fix the end of the connective pipe.(Refer to Tightening
Connection in REFRI-GERANT PIPING CONNECTION)

1 Drainage

Run the drain hose sloping downward. Do not install the drain
hose as illustrated below.
CAUTION

Connect the indoor unit first then the outdoor unit and bend
and arrange the pipe carefully.

Do not allow the piping to let out from the back of the
indoor unit.

Be careful not to let the drain hose slack.


Do not form a rise Do not put the hose
end into water Insulate both of the auxiliary piping.

Fig.5-5 Banding the drain hose under the auxiliary pipe.

Do not allow the piping to let out from the back of the
indoor unit.

installation manual

5
3 Piping and bandaging
6. REFRIGERANT PIPE INSTALLATION
Wind the connective cable, drain hose and wiring with tape
securely, evenly as shown below. CAUTION
Because the condensed water from rear of the indoor unit is Ventilate the air if there was any refrigerant leakage during
gathered in Pond Box and is piped out of room. Do not put installation.Leaked refrigerant will generate poisonous gas if
anything else in the box. meeting fire.

Make sure there is no refrigerant leakage after installation.


Indoor unit Pond box .Leaked refrigerant will generate poisonous gas if meeting fire.

Connective
Pipe room 6.1 Allowed Length and Drop of Piping
cable
.. . .
.
.. . . ..
.
. Connective
Requirements are different when installing the Outdoor
.. . .. .
pipe
.. .. Unit,Please refer to Outdoor Unit Installation Manual for
.
. ... .. . .
detailed information.
Wrapping belt

Drain hose
Fig.5-9 6.2 Material and Size of the Piping
Table 6-1
5.4 Indoor Unit Installation Pipe Material Copper Pipe for Air Conditioner
Model (kW) 1.5/2.2/2.8/3.6/4.5 5.6/7.1
Pass the piping through the hole in the wall. (Gas side) Φ12.7 Φ15.9
Size(mm)
(Liquid side) Φ6.4 Φ9.5
Put the claw at the back of the indoor unit on the hook of
the installation board, move the Indoor Unit from side to
side to see that it is securely hooked.

Piping can easily be made by lifting the indoor unit with


6.3 Refrigerant Volume to Be Added
a cushioning material between the indoor unit and the
wall. Get it out after finish piping. Refrigerant Volume to be added is calculated according to
Outdoor Unit Installation Manual .
Push the lower part of the Indoor Unit up to the wall,Then Be save to add refrigerant measuring by a scale.
move the Indoor Unit from side to side, up and down to
check if it is hooked securely.

hooker
CAUTION

Cushioning If refrigerant volume added is inadequate (too much or


material insufficient),the compressor malfunction will be caused.Be
sure to calculate the refrigerant volume carefully.

The service man should note down the piping length and
Fig.5-10 refrigerant volume added on the nameplate, which is on the
Electric Control Box Cover of outdoor unit for to diagnose the
compressor when compressor malfunction occurs.

6.4 Connection of the Refrigerant Pipe


Connection of the refrigerant pipe should
be done by professionals.
Double-span should be used when
connecting pipesof Indoor Unit.

CAUTION

The temperature of refrigerant circuit will be high, please


keep the interconnection cable away from the copper tube.

installation manual

6
1 Take out the faceplate,then dismantle the display cover
plate.(see Fig.7-1)
Tightening Torque
faceplate
Table 6-2
Outer diameter(mm) Tightening Torque
of connection piping (N.m)

Φ6.4 14.2~17.2 display cover plate


Φ9.5 32.7~39.9
Φ12.7 49.5~60.3
Φ15.9 61.8~75.4
Φ19.1 97.2~118.6

S faceplate faceplate
NOTE

Please refer to installation instructions for the refrigerant


piping conection of the air conditioner that with throttle
device inside. wiring cover plate

7. WIRING CHART Fig.7-1

Model(kW) 1.5~7.1
Phase 1-Phase
Power
Frequency and volt 208/230V-1ph-60Hz
2 Individual connect the power cord and signal line,adjust the
dial switch.(see Fig.7-2)
Manual switch/Insurance (A) 15/15
the wire holder of power the wire holder of signal
3x2.5 cord(three-position)) line (five-position))
Indoor unit power wiring (mm2)
2x4.0+1x2.5 display cover plate
(Add eletrical auxiliary heat)

Indoor/outdoor connectingwiring
(mm2) (Electric signal) 3x0.75(3x0.75)

5A dial switch
Fuse (A)
8A
(Add eletrical auxiliary heat)
S faceplate
Power (208/230V-1ph-60Hz)
the wire holder of power the wire holder of signal
cord(three-position)) line (five-position))

INDOOR UNIT
wiring cover plate

CENTRAL CONTROL
MONITOR(CCM) COMPUTER

INDOOR UNIT
OUTDOOR UNIT dial switch
Fig.7-2
INDOOR UNIT

the shielded twisted-pair wire

CAUTION

CAUTION An all-pole disconnection device which has at least 3mm


separation distance in all pole and a residual current
device(RCD)with the rating of above 10mA shall be
The reserved function is indicated in broken line table,users incorporated in the fixed wiring according to the nati-
can select it when necessary. onal rule.

installation manual

7
7.1 Terminal Board Diagram 7.2 Horsepower set
Please refer to the indoor unit wiring diagram for the wiring.
Horsepower code
PO WER_S
NOTE EF 0
D

123 4
ABC
The air-conditioners can connect with Central Control Monitor
(CCM). Before operation, please wiring correctly and set system 56
789
address and network address of indoor units.
ENC1

Single phase indoor unit

BLUE ENC1 Toggle switch For set horsepower


BLUE

RED
RED

Y/G Y/G Code Capacity(Horsepower)


Note: The horsepower
F 1500W(0.6HP)
has been set before
leaving the factory , 0 2200W(0.8HP)
XT1 L N XT1 L1 L2 anyone can’t
modify it except the 1 2800W(1.0HP)
maintenance person.
2 3600W(1.2HP)

3 4500W(1.5HP)
POWER IN POWER IN 5600W(2.0HP)
4
INDOOR UNIT POWER INDOOR UNIT POWER 7100W(2.5HP)
5
208/230V-1ph-60Hz 208/230V-1ph-60Hz
(Conventional) (Special for UL)
YELL OW
BLA CK

BLA CK
WHIT E

GRAY
BLU E

X Y (E) P Q (E)

To central control To outdoor


CAUTION
Monitor (CCM) COMM. BUS
COMM. BUS
Please adopt the shielded twisted-pair wire, The system together have 64units(0-63),everyone has only
and connect the shielded layed to (E) system addresscode,If two addresses are the same in one
system , the abnormal operation will occur.

MAIN BOARD DISPLAY BOARD Please switch off the power before setting,otherwise the
unexpected error will occur.
WIRE CONTROLLER

7.3 Network address set


1) Network address is set by communication of indoor and
outdoor unit; the address is the same as indoor address, there
To wire controller is no need to set separately.
2) The central control of indoor units can be done on outdoor
unit, there is no need to control indoor unit separately, for
details please refer to V4+ outdoor unit manual.
3) For previous control of indoor units, the network can be set
The reserved wire control function is indicated in broken by connecting (X,Y,E) terminals, there is no need to set
line table,users can purchase the wire controller when network address. The network can also be set by outer
necessary. network module and main board (CN20).

installation manual

8
7.4 Main board Code designation

SW1 definition
SW1 ● 1 means factory test mode SW1
ON ON ● 01 means DC fan static pressure is 1
● 0 means auto addressing mode
(reserved)
(default setting)
1234 1234
SW1 SW1
ON ● 1 means DC fan Is chosen ON ● 10 means DC fan static pressure is 2
● 0 means AC fan Is chosen
(reserved)
1234 1234
SW1 SW1
ON ● 00 means DC fan static pressure is 0
ON ● 11 means DC fan static pressure is 3
(reserved) (reserved)
1234 1234

SW2 definition
SW 2 SW2
ON ● 00 means shutting down the ON ● 00 means the time of stopping
unit to"stop cold air" at 15 degrees indoor fan is 4 minutes
1234 1234
SW 2 ● 01 means shutting down the SW2
ON ON ● 01 means the time of stopping
unit to"stop cold air" at 20 degrees indoor fan is 8 minutes
1234 1234
SW 2 ● 10 means shutting down the SW2
ON ON ● 10 means the time of stopping
unit to"stop cold air" at 24 degrees
indoor fan is 12 minutes
1234 1234
SW 2 ● 11 means shutting down the SW2
ON unit to"stop cold air" at 26 degrees ON ● 11 means the time of stopping
indoor fan is 16 minutes
1234 1234

SW5 definition
S W5 SW5
ON ● 00 means temp.compensation ON ● 10 means temp.compensation
value is 6 degrees under heat mode value is 4 degrees under heat mode
1 2 1 2
S W5 SW5
ON ● 01 means temp.compensation ON ● 11 means temp.compensation
value is 2 degrees under heat mode value is 8 degrees under heat mode
1 2 1 2

J1,J2 definition
SW6 definition
SW6
J1
without jumper "J1" for
ON ● 1 means old display panel auto restart function
● 0 means new display panel
1 2 3
SW6 J1
ON ● 1 means auto air blow under auto mode with jumper "J1" for
● 0 means auto air blow under non-auto mode non-auto restart function
1 2 3
SW6 J2
ON reserved reserved

1 2 3

installation manual

9
0/1 definition
According to the user’s requirement, install the remote controller
frame where the remote controller’s signal can reach the indoor
ON unit smoothly.
Means 0
Test operation
● Set the air conditioner under the mode of “COOLING”with the
ON remote controller, and check the following points per the
Means 1 ● “Owner’s Manual”If there is any malfunction, please resolve it
through chapter “Troubles And Causes ”.

The indoor unit

● Whether the switch on the remote controller works well.

● Whether the buttons on the remote controller works well.

● Whether the air flow louver moves normally.

● Whether the room temperature is adjusted well.

● Whether the indicator lights normally.

● Whether the temporary buttons works well.

8 TEST OPERATION ● Whether the drainage is normal.

● Whether there is vibration or abnormal noise during operation.

● Whether the air conditioner heats well in the case of the


CAUTION HEATING/COOLING type.

The outdoor unit


Protection function will delay the startup of compressor for 3
minutes in case the unit is turned on immediately after power on or re- ● Whether there is vibration or abnormal noise during operation.
started after shutdown.
● Whether the generated wind, noise, or condensed water by the
air conditioner have influenced your neighborhood.

● Whether any of the refrigerant is leaked.


The test operation must be carried out after the entire installation
has been completed.

Please confirm the following points before the test operation:

● The indoor unit and outdoor unit are installed properly.

● Tubing and wiring are correctly completed.

● The refrigerant pipe system is leakage-checked.

● The drainage is unimpeded.

● The heating insulation works well.

● The ground wiring is connected correctly.

● The length of the tubing and the added stow capacity of the
refrigerant have been recorded.

● The power voltage fits the rated voltage of the air conditioner.

● There is no obstacle at the outlet and inlet of the outdoor and


indoor and indoor units.

● The gas-side and liquid-side stop values are both opened.

● The air conditioner is pre-heated by turning on the power.

installation manual

10