Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Exam. ET 211 2023

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

COLLEGE OF TECHNOLOGY

Electronics Technology Department


MIDTERM EXAMINATION IN ET211
Electrical Circuits (DC) and Devices

Name: _________________________________________ Date: ______________ Score/Rating: _________

I – DIRECTION: Choose the letter of the correct answer.

_____ 1. Electrical works cannot be done without one of the following.


a. Electrical tape b. Tools and equipment c. Pliers d. Electricity
_____ 2. The most important thing must be secured before, during and after performing electrical works.
a.Salary b. Safety c. Tools and Equipment d. all of the above
_____ 3. A type of tester that only tells if the voltage is present but cannot tell the exact amount of voltage.
a. multi tester b. screw driver c. neon tester d. clamp meter
_____ 4. It is an interconnection of electrical components or system to utilize electricity.
a. Device c. Power Tools
b. Electrical Circuit d. Series
_____ 5. The first thing that one should do before working in a circuit.
a. Test the Circuit b. Shut the Power Off c. Cut the Circuit Line d. Leave it On
_____ 6. An Electrical Instrument that can measure resistance, current and voltage with a needle and scale.
a. Analog Multimeter b. Digital Multimeter c. Watt meter d. Clamp meter
_____ 7. Instrument that uses digital figures to measure resistance, current and voltage.
a. Megger Tester c. Digital multimeter
b. Volt meter d. Ammeter
_____ 8. It used to heat up pvc pipe to make elbows or to bend.
a. flame gun b. blower c. hammer d. hacksaw
_____ 9. A hand-held power tools that are used to chip away at or break up concrete.
a. flame gun b. chipping gun c. pistol gun d. glue gun
_____10. A tool used in conjunction with a very long lever, used to bend angles in conduit, that electric wires
are placed into.
a. flame gun b. EMT bender c. blender d. extender
_____11. The circuit conductors between the final overcurrent device protecting the circuit and the outlets.
a. circuit breaker b. branch circuit c. fuse d. panel board
_____12. An accessory such us locknuts, bushing, or other part of wiring system that is intended primarily to
Perform a mechanical rather than an electrical function.
a. feeder b. fitting c. fuse d. all of the above
_____13. An ability of a conductor that allows the electricity to flow.
a. Resonance b. Conductance c. Current d. Voltage
_____14. What is the unit of current?
a. ampere b. joules c. voltage d. ohms
_____15. Rendered inaccessible by the structure or finish of the building.
a. conduit b. fitting c. concealed d. exposed
_____16. On or attached to the surface or behind panels designed to allow access.
a. conduit b. fitting c. concealed d. exposed
_____17. What is the standard size of utility box?
a. 2x2” b. 4x4” c. 3x4” d. 2x4”
_____18. What is the shape of pvc junction box?
a. rectangle b. triangle c. hexagon d. octagon
_____19. Surrounded by a case, housing, fence or walls that prevents persons from accidentally contacting
the energized parts.
a. enclosed b. concealed c. closed d. guarded
_____20. A metal enclosure with hinged or metal doors that supplements the wiring space equipment.
a. enclosure b. nema 3r c. wire gutter d. panel board
_____21. An equipment used to govern all connection usually place after the metering equipment.
a. service equipment b. circuit breaker c. meter base d. switch gear
_____22. The electrical engineering law that must be followed or implemented by licensed electrical
practitioner such REE, RME and PEE
a. R.A 7920 b. R.A 1996 c. R.A 4411 d. R.A 7820
_____23. The standard height of service pole along commercial areas parking lots, agricultural areas subject
to truck traffic.
a. 22ft b. 18ft c. 20ft d. 12ft
_____24. Service pole standard height for public streets, alleys, roads and driveways.
a. 22ft b. 18ft c. 20ft d. 12ft
_____25. Connected to earth or to some conducting body that serves in place to earth.
a. jumper b. conduit c. grounded d. equipment
_____26. What is the standard length of a ground rod?
a. 18ft b. 9ft c. 8ft d. 10ft
_____27. An aircon has 30 amperes current, with a power factor of 80% and supplied with 240 volts.
What is the exact wattage of aircon?
a. 1,200w b. 1hp c. 5,760w d. 746w
_____28. A type of switch that can control lights in two different places.
a. 2gang b. 3gang c. 3way d. 4way
_____29. A type of switch that can control three different places.
a. 2gang b. 3gang c. 3way d. 4way
_____30. Single pole double throw (SPDT) what type of switch is that?
a. 2gang b. 3gang. c. 3way d. 4way

II – DIRECTION: Write the equivalent size of given sizes of wire and standard ampere rating.

AWG mm Ampere
16
14
12
10
8
6
4
3
2
1