Project ProNo.

Page
1

Item
1

HALFEN Design Software HTA, Version 2.96

The design does only apply to the designated HALFEN product. The load bearing capacity of
third party products, appearing to be identical in construction, might differ. For this
reason, the software provider does not extend warranty if non-HALFEN products are used.

System parameters
© Leviat GmbH, Langenfeld, Germany

Anchor channel HZA DYNAGRIP 38/23 - FV - 300 / 2, 2 Anchor


T-bolt HZS 38/23 M 12 FV/GV-S 8.8
Approval / Design method EN 1992-4 / EOTA TR047 / CEN/TR 17080 - ETA-20/1081
Shear load Without lever arm
Concrete C35/45, cracked
Reinforcement of concrete member No dense reinforcement
Edge reinforcement No edge reinforcement
HALFEN Ltd. trading as Leviat, A1/A2 Portland Close, LU5 5AW Houghton Regis, Tel.: +44 1582 470300, Fax: +44 1582 470304

h = 200 mm l = 300 mm c11 = 100 mm c21 = 178 mm


cnom = 20 mm

Adjusting zone ±: Full variability

T-bolt xcbo.1 /scbo N cbEd V cbEd,y V cbEd,x T-bolt scbo N cbEd V cbEd,y V cbEd,x
[mm] [kN] [kN] [kN] [mm] [kN] [kN] [kN]
1 70 0.55 5.00 0.85 2 160 0.55 5.00 0.85

Utilisation: 69% - Verification successful

HTA 2.96
04/06/2024
Project ProNo. Page
2

Item
1

Calculation Summary Utilisation

Verifications for T-bolt


Tension NRd,s,s 1%
Shear VRd,s,s 19%
Combined loading NRd,s,s - VRd,s,s 19%
© Leviat GmbH, Langenfeld, Germany

Verifications for cast-in channels


Channel lips - Tension NRd,s,l 3%
Channel lips - Shear perpendicular VRd,s,l,y 21%
Channel lips - Shear longitudinal VRd,s,l,x 8%
Flexure of channel MRd,s,flex 2%
Combined loading NRd,s,l - VRd,s,l 31%

Connection anchor - channel (Tension) NRd,s,a,c 3%


Connection anchor - channel (Shear) VRd,s,a,c 25%
Connection anchor - channel (Shear, longitudinal) VRd,s,a,c,x 7%
Combined loading NRd,s,a,c - VRd,s,a,c 35%

Verifications for concrete


Tension - Pull-out failure NRd,p 2%
HALFEN Ltd. trading as Leviat, A1/A2 Portland Close, LU5 5AW Houghton Regis, Tel.: +44 1582 470300, Fax: +44 1582 470304

Tension - Concrete cone failure NRd,c 4%


Tension - Concrete splitting failure NRd,sp N/A
Tension - Blow-out failure NRd,cb N/A
Shear - Pry-out failure VRd,cp 18%
Shear - Pry-out failure (longitudinal) VRd,cp,x 3%
Shear - Concrete edge failure VRd,c 69%
Shear - Concrete edge failure (longitudinal) VRd,c,x N/A
Shear - Concrete edge failure, load parallel to edge VRd,c90 23%
Shear - Concrete edge failure, load parallel to edge VRd,c90,x 4%
(longitudinal)

Combined loading NRd,c,p,sp - VRd,c,cp 64%

Verifications:

Steel

T-bolt

Maximum tension load (T-bolt): T-bolt 1 EN 1992-4, 7.4.1.3

67.40 1.50 0.55 < 44.93 kN 0.01

Maximum shear load without lever arm (T-bolt): T-bolt 1 EN 1992-4, 7.4.2.3.1

HTA 2.96
04/06/2024
Project ProNo. Page
3

Item
1

33.70 1.25 5.00 0.85 5.07 < 26.96 kN 0.19

Combined load: T-bolt 1 EN 1992-4, 7.4.3.1


© Leviat GmbH, Langenfeld, Germany

0.55 44.93 0.01 5.07 26.96 kN 0.19

1.0

0.04 < 1.0 0.19

Local flexure of channel lips


HALFEN Ltd. trading as Leviat, A1/A2 Portland Close, LU5 5AW Houghton Regis, Tel.: +44 1582 470300, Fax: +44 1582 470304

Maximum tension load (T-bolt): T-bolt 1 EN 1992-4, 7.4.1.3 (2)

76 1.00 39.30 39.30 1.80

0.55 < 21.83 0.03

Maximum shear load (T-bolt): T-bolt 1 EN 1992-4, 7.4.2.3.1 (2)

76 1.00 43.90 43.90 1.80

5.00 < 24.39 0.21

HTA 2.96
04/06/2024
Project ProNo. Page
4

Item
1

Maximum shear load (T-bolt) longitudinal: T-bolt 1 EOTA TR 047, B.6.2.2.2.4


CEN/TR 17080, 7.2.2.2.4
© Leviat GmbH, Langenfeld, Germany

23.60 1.80 1.20 2.16 0.85 < 10.93 0.08

Flexure of channel EN 1992-4, 7.4.1.3

Decisive span between Anchor 1 and Anchor 2

1497 1.15 30 < 1302 0.02


HALFEN Ltd. trading as Leviat, A1/A2 Portland Close, LU5 5AW Houghton Regis, Tel.: +44 1582 470300, Fax: +44 1582 470304

lips combined EOTA TR 047, B.6.3.1.3


CEN/TR 17080, 7.3.1.4
T-bolt 1, load position xcb,1 = 110 mm

0.55 21.83 0.03 30 1302 0.02

5.00 24.39 0.21 0.85 10.93 0.08

0.23 0.92 0.31

Anchor

Tensile load, Anchor 1, load position xcb,1 = 28 mm EN 1992-4, 7.4.1.3

31.40 1.78 0.66 < 17.64 0.04

HTA 2.96
04/06/2024
Project ProNo. Page
5

Item
1

Shear load, Anchor 1, load position xcb,1 = 28 mm EN 1992-4, 7.4.2.3.1

43.90 1.48 5.99 < 29.66 0.20


© Leviat GmbH, Langenfeld, Germany

Shear load longitudinal, Anchor 1 EOTA TR 047, B.6.2.2.2.2


CEN/TR 17080, 7.2.2.2.2

18.80 1.48 0.85 < 12.70 0.07

Connection anchor - channel


HALFEN Ltd. trading as Leviat, A1/A2 Portland Close, LU5 5AW Houghton Regis, Tel.: +44 1582 470300, Fax: +44 1582 470304

Tensile load, Anchor 1, load position xcb,1 = 28 mm EN 1992-4, 7.4.1.3

36.00 1.80 0.66 < 20.00 0.03

Shear load, Anchor 1, load position xcb,1 = 28 mm EN 1992-4, 7.4.1.3

43.90 1.80 5.99 < 24.39 0.25

Shear load longitudinal, Anchor 1 EOTA TR 047, B.6.2.2.2.3


CEN/TR 17080, 7.2.2.2.3

21.60 1.80 0.85 < 12.00 0.07

HTA 2.96
04/06/2024
Project ProNo. Page
6

Item
1

Combined load EOTA TR 047, B.6.2.2.2.2


CEN/TR 17080, 7.3.1.3
Anchor 1, load position xcb,1 = 28 mm
© Leviat GmbH, Langenfeld, Germany

0.66 17.64 20.00 0.04

5.99 29.66 24.39 0.25

0.85 12.70 12.00 0.07


HALFEN Ltd. trading as Leviat, A1/A2 Portland Close, LU5 5AW Houghton Regis, Tel.: +44 1582 470300, Fax: +44 1582 470304

0.28 < 0.93 0.35

Concrete

Tensile load - Concrete cone failure EN 1992-4, 7.4.1.5

Tensile load, Anchor 1, load position xcb,1 = 28 mm

25.15 1.50 0.66 < 16.77 0.04

HTA 2.96
04/06/2024
Project ProNo. Page
7

Item
1

8.10 35 94 43.67 244 399 0.86

199 100 0.71 178 N/A 0.94 1.00


© Leviat GmbH, Langenfeld, Germany

Tensile load - Pull-out failure EN 1992-4, 7.4.1.4

Tensile load, Anchor 1, load position xcb,1 = 28 mm

61.83 1.50 0.66 < 41.22 kN 0.02


HALFEN Ltd. trading as Leviat, A1/A2 Portland Close, LU5 5AW Houghton Regis, Tel.: +44 1582 470300, Fax: +44 1582 470304

21.20 35 2.92

Shear load - Pry-out failure EN 1992-4, 7.4.2.4

Shear load, Anchor 1, load position xcb,1 = 28 mm

2.00 25.15 50.30 1.50 5.99 < 33.54 0.18

43.67 0.86 0.71 178 N/A 0.94 1.00

Shear load longitudinal, Anchor 1, load position xcb,1 = 70 mm

2.00 23.53 47.07 1.50 0.85 < 31.38 0.03

HTA 2.96
04/06/2024
Project ProNo. Page
8

Item
1

43.67 0.81 0.71 178 N/A 0.94 1.00

Shear load - Concrete edge failure EN 1992-4, 7.4.2.5


© Leviat GmbH, Langenfeld, Germany

Shear load, Anchor 1, load position xcb,1 = 28 mm


HALFEN Ltd. trading as Leviat, A1/A2 Portland Close, LU5 5AW Houghton Regis, Tel.: +44 1582 470300, Fax: +44 1582 470304

13.08 1.50 5.99 < 8.72 0.69

7.50 35 100 20.60 244 38 476

0.81 178 N/A 238 0.86 200 23

246 0.90 1.00

Shear load, parallel to edge, Anchor 1, load position xcb,1 = 28 mm

HTA 2.96
04/06/2024
Project ProNo. Page
9

Item
1

39.47 1.50 5.99 < 26.31 0.23

7.50 35 178 44.43 244 38


© Leviat GmbH, Langenfeld, Germany

1.00 100 N/A 394 0.50 200 23

402 0.71 2.50 1.00

Shear load longitudinal, parallel to edge, Anchor 1 EOTA TR 047, B.6.2.2.4.2


load position xcb,1 = 70 mm CEN/TR 17080, 7.2.2.4.3
HALFEN Ltd. trading as Leviat, A1/A2 Portland Close, LU5 5AW Houghton Regis, Tel.: +44 1582 470300, Fax: +44 1582 470304

30.37 1.50 0.85 < 20.25 0.04

1.70 94 10 100 0.10 0.06 35

16.75 178 N/A 200 81600 45000 1.00

1.00 1.00

Combined load EN 1992-4, 7.4.3


EOTA TR 047, B.6.2.2.4.2
Anchor 1, load position xcb,1 = 28 mm CEN/TR 17080, 7.3.1.5

0.66 41.22 16.77 N/A N/A 16.77 0.04

Edge c11

5.99 33.54 8.72 8.72 0.69

HTA 2.96
04/06/2024
HALFEN Ltd. trading as Leviat, A1/A2 Portland Close, LU5 5AW Houghton Regis, Tel.: +44 1582 470300, Fax: +44 1582 470304 © Leviat GmbH, Langenfeld, Germany

Edge c21

0.85
5.99
0.85

31.38
33.54
31.38
Project

N/A

0.27
0.77

26.31
20.25

<
<
1
Item
ProNo.

1.2
1.2
1.2
1.2

26.31
20.25

31.38
10
Page

0.22
0.03
0.23
0.64
0.04

HTA 2.96
04/06/2024