GENERAL NOTES

All dimensions are shown in mm unless otherwise


1 2 3 4 5 6 7 8 specified
The contractor must check and verify all dimensions
on site before commencement of any work
17,400
CONSTRUCTION
All soils under slabs and around external
2780 3,250 1,200 1,200 3,440 3260 1200 foundations should be treated with antitermite
Depth of foundation to be determined on site
200 but to be not exceeding 150mm deep
340 2,510 200 3,075 150 1,025 1,025 150 3,265 200 5,060 200 conc. strip to S.E's details

200
All walls less than 200mm thick to be

A A reinforced with hoop iron at every alternate course


1,000

1,125 MECHANICAL
All plumbing and drainage to comply with town

B B council specifications
Drains passing beneath buildings to be encased in
150mm concrete sorrounding
1200

150

All underground foul and waste pipes shall


be UPVC to comply
C C All testing of pipes should be done before plastering

East Elevation
All sanitary work should be in accordance with
Therapy
West Elevation

Therapy Therapy Ministry of Health regulations


3,525

room 1 room 3 ELECTRICAL

room 2 Alll conduits should be laid before plastering


2,799
9,700

D D
2,150 200
1200

Revision History
E E RevID ChID Change Name Date

11
18

17

16

15

14

13

12

10
2,350

2,350

S-02 S-02
18R x 167

UP
17G x 304

F 1
F
2

9
DOWN

284 465 502 316


1780 900 900 1,500 600 625 600 544 1,500 666 900 900 1,169 1,800 1,312
200 SELF
340 2,510 200 3,075 150 1,025 1,025 150 3,265 200 5,060 200 BETTY JEAN GITAU

17,400 St Albans Centre, Acacia Valley Rongai


Telephone: 0722 779871
S-01

1 2 3 4 5 6 7 8
1 2 3 4 5 6 8
South Elevation TYPICAL 1st & 2nd Floor Plan
Roof Notes:

A B C D E F Reinforced Concrete roof with a gentle slope to


150mm fulbora
S.E's details

3.000
Roof Notes:
Reinforced Concrete roof with a gentle slope to
150mm fulbora
Balcony #Project Name
S.E's details
Staircase Details PROPOSED THERAPY COMPLEX ON PLOT NO.
TREAD - 250mm
RISER - 150mm NGONG/NGONG/ 36885
WAIST - 175mm

3.000
Drawing Name
1. Plan
Wall specifications
Balcony 2. Sections
450mm RC beams to S.E's details

900
200mm hand dressed stone wall with horizontal
keys Floor slab Notes:
3. Elevations
1:4 mortar/sand ratio RC column as per 150mm Thick RC slab to S.E's details
S.E's details 3.000
Reinforced with BRC A95 wire mesh on one layer
of 1000G polythene DPM on 50mm murram
blinding on 300mm well compacted hardcore in
2100 Client
Floor slab Notes:
layers of 150mm, on firm ground free of black
cotton soil
1.500 St. Albans Centre
150mm Thick RC slab to S.E's details Soil treated with approved antitermite treatment
Acacia Valley, Ongata Rongai
Reinforced with BRC A95 wire mesh on one layer
of 1000G polythene DPM on 50mm murram
blinding on 300mm well compacted hardcore in
Drawing Status
layers of 150mm, on firm ground free of black
cotton soil Final
Soil treated with approved antitermite treatment

GL Drawn by: Date


F.J.K
Substructure wall notes 2780 3.250 1.200 1.200 3.440 5.260
200mm natural stone foundation
walling
Foundation depth to be determined
1 2 3 4 5 6 8 Checked by Date
on site

Foundation notes Drawing Scale


Column footing to S.E's details
600x200mm wide RC strip
1,000 1,201 2,799 2,250 2,350 1:50
mix 1:1.5:3 to S.E's details
A B C SEC-01 D E F Layout ID Revision

GSPublisherVersion 0.0.100.100
SEC- 02 A.01.2