You are on page 1/ 4

Replacing Faceplate of Gen 3 Wall

Connector
tesla.com/wallconnector
Removing Faceplate............................................. 2
Installing Faceplate............................................... 3
REMOVING FACEPLATE

Tools and Equipment:


• T10 Torx bit
• 4 mm hex bit

WARNING: Do not service the Wall Connector while it is energized. Turn off power to the Wall
Connector at the upstream circuit breaker prior to servicing.

1. TURN OFF POWER TO THE WALL CONNECTOR AT THE CIRCUIT BREAKER. Wait 5 minutes for the
Wall Connector to completely de-energize.

2. Use a 4 mm hex bit to remove the 4 fasteners securing the main unit to the wirebox. Remove the main
unit from the wirebox.

3. Use a T10 Torx bit to remove the 2 screws securing the faceplate to the main unit.

4. Push the faceplate slightly downward to release it from the 2 sliding tabs at the top of the main unit.
Remove the faceplate.

Replacing Faceplate of Gen 3 Wall Connector 2


INSTALLING FACEPLATE

Tools and Equipment:


• T10 Torx bit
• 4 mm hex bit

1. Position the faceplate on top of the main unit so the 2 screw pegs at the bottom of the faceplate
touch the bottom edge of the main unit.
2. Center the top of the faceplate in the main unit so the 2 tabs at the top of the faceplate align with the
2 tabs at the top of the main unit.
3. With the 2 sliding tabs aligned, push the faceplate upward until the 2 tabs securely connect.

4. Verify that the faceplate is seated securely and sits slightly higher than the main unit at the top.

5. Secure the faceplate to the main unit with 2 screws using a T10 Torx bit. Hand-tighten the screws.

6. Use a 4 mm hex bit to secure the main unit to the wirebox with the four fasteners. Apply pressure to
the faceplate to compress the internal seal.

7. Turn on power to the Wall Connector at the circuit breaker.