METRAVI DIGITAL CLAMP METER DT-2250

TECHNICAL SPECIFICATIONS
Function Range & Resolution Accuracy (% of reading
± no. of dgts)
40.00 AAC ± (2.5% + 10 digits)
AC Current 400.0 AAC ± (2.5% + 5 digits)
1000 AAC ± (3.0% + 4 digits)
400.0 mVDC ± (0.8% + 3 digits)
4.000 VDC
DC Voltage 40.00 VDC ± (1.5% + 3 digits)
400.0 VDC
600 VDC ± (2.0% + 3 digits)
400.0 mVAC ± (0.8% + 20 digits)
4.000 VAC
AC Voltage 40.00 VAC ± (1.8% + 5 digits)
400.0 VAC
600 VAC ± (2.5% + 5 digits)
400.0 W ± (1.0% + 4 digits) GENERAL SPECIFICATIONS
4.000 KW
Resistance 40.00 KW ± (1.5% + 2 digits) Input Limits
400.0KW Function Maximum Input
4.000 MW ± (2.5% + 3 digits) A AC 1000A
40.00 MW ± (3.5% + 5 digits) V DC, V AC 600V DC/AC
40.00nF ± (5.0% + 100 digits) Resistance, Diode, Continuity 250V DC/AC
Frequency, Duty Cycle Test
400.0nF ± (3.0% + 5 digits)
Temperature (ºC/ºF) 60V DC/24V AC
Capacitance 4.000mF ± (3.5% + 5 digits)
40.0mF Clamp size Opening 1.2” (30mm) approx
100.mF ± (5.0% + 5 digits) Diode Test Test current of 0.3mA typical;
Open circuit voltage 1.5V DC
5.000Hz ± (1.5% + 5 digits) Continuity Check Threshold <100W;
50.00Hz Test current < 1mA
500.0Hz Low Battery Indcation “ ” is displayed
Overrange Indication “OL” is displayed
Frequency 5.000kHz ± (1.2% + 5 digits) Measurements Rate 2 per second, nominal
50.00kHz Sensitivity: 10Vrms min. Input Impedance 7.8 MW (VDC and VAC)
500.0kHz Display 4000 counts Backlit LCD, 3-3/4 digits
5MHz ± (1.5% + 10 digits) AC Current bandwidth 50/60Hz (AAC)
AC Voltage bandwidth 50/60Hz (VAC)
10.00MHz
Operating Temperature 14 to 122ºF (-10 to 50ºC)
Duty Cycle 0.5 to 99.0% ± (1.2% + 2 digits) Storage Temperature -14 to 140ºF (-30 to 60ºC)
Pulse width: 100ms - 100ms Relative Humidity 90% (0ºC to 30ºC);
Temp (type-K) -20.0 to 400.0ºC ± (3.0% + 5ºC) 75% (30ºC to 40ºC);
45% (40ºC to 50ºC);
(Probe 400 to 1000ºC Altitude Operating: 3000m; Storage 10,000m
accuracy not -4.0 to 400.0ºF ± (3.0% + 7ºF) Over voltage Category III 600V
included) 400 to 1832 ºF Battery One “9V” Battery
Note: No Autoranging & 400mV AC Voltage Range Auto Power OFF Approx. 30 minutes
Dimensions/Weight 229 x 80 x 49 mm / 303g
OPTIONAL ACESSIORIES: Data Hold To freeze the displayed data
l Infra-red non contact temperature adaptor to measure temperature from -30°C to 550°C with Safety: For indoor use and in accordance with Overvoltage Category II,
Pollution Degree 2. Category II includes local level, appliance, portable
fixed emissivity of 0.95 and distance to sighting ratio of 8:1. Model TS-03
equipment, etc., with transient overvoltages less than overvoltage Cat III

*Technical Specifications & Appearance are subject to change without prior notice