Auto Transfer Switch

Introduction

Daijin Electrics is always here


for customers’ satisfaction.

Daijin Electrics is ‘Green Company’ and we are providing Daijin’s ATS are suitable for; Daijin’s ATS comes with;

Eco-friendly manufactures’ for the Earth and people.


Any types of Switch Gear Various models from 100A to 6300A
We never stop providing the best of best technology Motor control Switch Gear & Mechanism High rated switching performance 100kA
protection protection Switch Gear (6300AF at 600Vac)
of manufactures.

39 ATS_ 40
ATS www.Daijinelec.com
Auto Transfer Switch

External Configurations & Specifications(SYF) Circuit Diagrams(SYF)

AC POWER

DC POWER
Specification
SYF Type 01 02 04 06
Rated Current 100A 200A 400A 600A
Rated Voltage AC 600V/DC 125V
Number of Poles 3/4
Operating Time 0.06sec.
Change Over Time 0.08sec.
Max. Weight (3/4 poles Kg) 8.5kg 13kg
AC100/110V 8A 15A
Inrush
AC200/220V 5A 12A
Current
DC100/110V 8A 15A

Short Time Peak (KA) 12


w/Stand Capacity rms (KA) / sec. 5
Mechanical Life 25,000 times
Performance
Switching Frequency 5,000 times/hour
Accessories Auxiliary Switch w/2C Capacity AC110V 5A, DC110V 5A

41 ATS_ 42
ATS www.Daijinelec.com
Auto Transfer Switch

Outline Dimension Drawings(SYF)

ATS-F TYPE [100A~200A] 42 35


ATS-F TYPE [400A~600A] 52.4 55

2P 100AF 2P 100AF

136.9

141.4
176.5 282.8 216 308.6

ATS-F TYPE [100A~200A] 42 35 35


ATS-F TYPE [400A~600A] 52.4 55 55

3P 100AF 3P 100AF

136.9

141.4
211.5 282.8 271 308.6

ATS-F TYPE [100A~200A] ATS-F TYPE [400A~600A] 52.4 55 55 55


42 35 35 35
4P 100AF 4P 100AF
136.9

141.4
246.5 282.8 326 308.6

43 ATS_ 44
ATS www.Daijinelec.com
Auto Transfer Switch

External Configurations & Specifications(SYB) Circuit Diagrams(SYB)

AC POWER

2
1. Manual Handle
2. N, R Contact Position Indicator
4
3. Terminal Block
4.- N Power Source Terminal
- R Power Source Terminal
- Loading Terminal

Specification
SYB Type 04 06 08 10 12 16 20 25 32 40 50 63

Rated Current 400 600 800 1000 1200 1600 2000 2500 3200 4000 5000 6300
DC POWER
Rated Voltage 600
Number of Poles 3/4
Operating Time 0.09sec.
Change Over Time 0.10sec.
Fixed 39/47 42/50 47/55 62/70 70/78 110/160
Max. Weight(kg)
Drawout 62/70 65/73 70/78 77/85 92/110 180/220
AC110V 27A 35A 80A
Inrush
AC220V 16A 28A 60A
Current
DC110V 27A 35A 80A
Short time Peak(KA) 75 75 81 81 85 85 105 105 105 127 127 127
w/Stand
Capacity rms (KA) / sec. 32 32 37 37 40 40 50 50 50 65 65 65

Performance Mechanical life 10000 times 7500 times

Dimensions Fixed 560x358x372 560x385x368 1070x383x370


W * H * D (mm)
Drawout 590x490x440 1090x490x440

45 ATS_ 46
ATS www.Daijinelec.com
Auto Transfer Switch

Outline Dimension Drawings(SYB)

FIXED TYPE FIXED TYPE


387
SYB04~SYB16 48.5 60 55 60 55 60 48.5 SYB04~SYB16 48.5 60 55 60
502
55 60 55 60 48.5
20
20

61

61
25 25
387 N

10
Ø12x2EA Ø12x2EA

10
40 56 45 70 45 70 45 56 40 502 78.5 115 115 115 78.5
78.5 115 115 78.5
56 45 70 45 70 45 70 45 56

104

104
Dimension Dimension
SYB12 SYB12
Current T(mm) W(mm) Current T(mm) W(mm)
10

10
25 25 N
630A ~ 1000A 10 45 40 Ø12x2EA 387 630A ~ 1000A 10 45 40 Ø12x2EA
78.5 115 115 78.5 502
38.5 80 35 80 35 80 38.5 78.5 115 115 115 78.5

104
104
1250A 10 60 1250A 10 60 38.5 80 35 80 35 80 35 80 38.5
1600A 10 80 SYB04 ~ SYB10 1600A 10 80 SYB04 ~ SYB10
10

10
40 40

89
89

25 25 Ø12x3EA 25 25 Ø12x3EA N
78.5 115 115 78.5 78.5 115 115 115 78.5

SYB16 SYB16

FIXED TYPE FIXED TYPE


SYB20~SYB25 20 20 SYB20~SYB25 20 20

61
387
61

61

61
20

20
25

25
40 40 38.5 80 35 80 35 80 38.5 40 40
104
104

104

104
Dimension Dimension 502
Ø12x3EA
20

25

20

25
25 25 38.5 80 35 80 35 80 35 80 38.5
Current T(mm) W(mm) 40 40 78.5 115 115 78.5 Current T(mm) W(mm) 40 40
104

104

104
104

2000A 20 80 2000A 20 80
25 25 N
2500A 25 80 2500A 25 80 Ø12x3EA
25

25
20

20
40 40 40 40 78.5 115 115 115 78.5
89

89

89
89

FIXED TYPE FIXED TYPE


20 20
SYB32 SYB32
61

61
30

30
387 502
45 45
33.5 90 25 90 25 90 33.5 33.5 90 25 90 25 90 25 90 33.5
104

104
30

Dimension

30
25 25 Dimension
45 45
Current T(mm) W(mm) N
104

Ø12x3EA 25 25

104
Current T(mm) W(mm) Ø12x3EA
3200A 35 90 78.5 115 115 78.5 3200A 35 90 78.5 115 115 115 78.5
30

30
45 45
89

89
30

30
When replacing old model(~May 2018) When replacing old model(~May 2018)
above 3200A above 3200A

ATS-B Type 3P ATS-B Type 4P


FIXED TYPE FIXED TYPE

387 502
358

358
415 138 24 163.5 25.5 530
138 24 163.5 25.5
445 351 560 351

47 ATS_ 48
ATS www.Daijinelec.com
Auto Transfer Switch

Outline Dimension Drawings(SYB)

FIXED TYPE FIXED TYPE


SYB40 3P SYB40 4P

20 20

66

66
40
40
507 662
45 45

99

99
Dimension 38.5 120 35 120 35 120 38.5 Dimension 38.5 120 35 120 35 120 35 120 38.5
Current Current

40
T(mm) W(mm) T(mm) W(mm)

40
45 45
4000A 40 120 4000A 40 120

99

99
22.5 25 25 25 22.5 Ø12x4EA 22.5 25 25 25 22.5 Ø12x4EA
99.5 154 154 99.5 100 154 154 154 100

40
40

45 45

94
94
30

30
When replacing old model(~May 2018) When replacing old model(~May 2018)
above 3200A above 3200A

ATS B-Type 3P ATS B-Type 4P


FIXED TYPE FIXED TYPE

507 662
358

358
535 138 24 163.5 25.5 690 138 24 163.5 25.5
565 351 720 351

49 ATS_ 50
ATS
Auto Transfer Switch

ATS Controller Outline Dimension Drawing

5 Cutting Hole
2 4. 2 .

1.
Normal Stand-by

Front Cover Cutting ole

212

11
1

1
ELESYS
Auto Transfer Switch CONTROLLER

1.
1 24. 2 4. 2 24.

SEC. 6 14
A B
11 13
9
15 17
7

1 7
5

A-RDY 3
20
1 B-RDY Circuit Diagrams
Manual B Type ATS Control Sequence Diagram
2 8 ATS DIAGRAM
A POWER B POWER
CONTROL PCB
Auto
Manual Manual
TB TB
CC A1 A1
MG1 FUSE
3 9 MG2
A2
B1
A2
B1 MANUAL AUTO
A-PWR B-PWR MG2 FUSE
B2 B2
ON ON

Load AC1 AC1 PCB


LS1
4 10 MG2
LS2
BC1 BC1

A-On B-On AC AC
A
A A
A-Prior BC BC 27 84
Daijin electric B
EVENT B B
KR GR K G

F Type ATS Control Sequence Diagram


ATS DIAGRAM CONTROL PCB
B POWER A POWER

Descriptions of External Appearances TB TB


CC AC1 A1
A2 A2 FUSE
MANUAL AUTO
1. Normal Time Operation LED 6. Nomal / Stand-by Time Setting Adjustment BC1 B1
FUSE
B2 B2
ON ON
AC
2. Normal Change Manual Button 7. Stand-by Time Operation LED N
A AC1
27
PCB
BC BC1
3. Normal Power Indicator LE 8. Stand-by Change Manual Button R B
84

AC
4. Normal Power On/Off Switch 9. Stand-by Power LED A
BC 27 84

5. Operated ATS Power Indicator LED 10. Stand-by Power On/Off Switch B
KR GR K G

51 ATS_ 52
ATS www.Daijinelec.com
Auto Transfer Switch

Switching Operation Trouble Shooting

Manual Operation

B-TYPE F-TYPE Malfunctions Probable Causes Corrective Actions

If the low voltage is occured after checking


‘Normal’ and ‘Stand-by’ Rated Voltage,
Overload Trip
please directly contact to the panel board
distributor.
clac!
clac!
clac! Please, change the accerssories and/or
Diod/or micro switch may NOT
if more questions please contact
Common in B are F properly work
Daijin Electrics A/S department.
[“B” and “F” Type]

Please, contact immediately to the A/S


Coil Failure center after checking the discoloration of
Manual change over If ‘Normal’ and ‘Stand-by’ are NOT
the coil or the reek smell.

automatically switched over


Manual method operation as normal-power such as following picture, if it is pulled down until it sounds ‘clac’. Please operate the manual handle bar and
It may be cause of missing
In opposite way, it’s switching NORMAL POWER to STAND-BY POWER if it’s not working right, directly contact to
part or broken
A/S department.
The Indicator shows A-ON(normal power) to B-ON(stand-by power) or B-ON to A-ON

! DANGER
Check for the connection and contact us.
Please do not touch main circuit or terminals, which is applying an electric current. It’s will result in Bad connection.

personal injury or property damage by electric shock to A-ON (“F” type shows N or R)

If ‘Normal’ and ‘Stand-by’ are NOT


Digital Please check if it’s working right.
Motored change over automatically switched over
Please perform following details
Please contact A/S Center immediately for
- When operating panel board, keep a function switch in local. It may be cause of missing
Either ‘Normal’ and ‘Stand-by’ working changing broken part.
- Stay A.T.S(draw-out type) at CONNECTED state part or broken

- Change over S/W shows A-ON(normal power) to B-ON(stand-by power) or B-ON to A-ON (“F” type shows N or R)
If the indicator lamps for
If the controller unit is not working or Please check the rated voltage and check
the control unit are
! CAUTION malfunction the connection between
not ‘On’ please contact us to
Voltage range for change over device is operating in 85%~110% rated voltage. main body of ATS and controller
change the lamp.

*Maintenance Period: 1 time/mth.

53 ATS_ 54