Tubing

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

Page Index

TUBING SPECIFICATION SHEETS

2-3/8” OD, 4.60 LBS/FT, L-80 TUBING w/ HYDRIL 511 CONNECTIONS Page 1
2-3/8” OD, 4.60 LBS/FT, P-110 TUBING w/ HYDRIL 511 CONNECTIONS 2
2-7/8” OD, 6.40 LBS/FT, L-80 TUBING w/ HYDRIL 511 CONNECTIONS 3
2-7/8” OD, 6.40 LBS/FT, P-110 TUBING w/ HYDRIL 511 CONNECTIONS 4
2-7/8” OD, 7.90 LBS/FT, P-110 TUBING w/ HYDRIL 533 CONNECTIONS 5
3-1/2” OD, 9.20 LBS/FT, L-80 TUBING w/ HYDRIL 511 CONNECTIONS 6
3-1/2” OD, 9.20 LBS/FT, P-110 TUBING w/ HYDRIL 511 CONNECTIONS 7
3-1/2” OD, 15.80 LBS/FT, L-80 TUBING w/ HYDRIL 533 CONNECTIONS 8
4” OD, 9.20 LBS/FT, L-80 TUBING w/ HYDRIL 511 CONNECTIONS 9
4” OD, 11.60 LBS/FT, P110 TUBING w/ HYDRIL 511 CONNECTIONS 10
4-1/2” OD, 15.50 LBS/FT, L-80 TUBING w/ HYDRIL 533 CONNECTIONS 11
5” OD, 18.00 LBS/FT, L-80 TUBING w/ HYDRIL 511 CONNECTIONS 12
5” OD, 18.00 LBS/FT, Q-125 TUBING w/ HYDRIL 521 CONNECTIONS 13
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

2-3/8” OD, 4.60 LBS/FT, L-80 TUBING w/ HYDRIL 511 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 2-3/8”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 4.60
GRADE L-80
NOMINAL WALL THICKNESS 0.190”
NOMINAL INSIDE DIAMETER 1.995”
DRIFT SIZE 1.901”
TYPE OF UPSET N/A
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 104,000
PIPE YIELD TORQUE (FT-LBS) 5,100
PIPE API COLLAPSE (PSI) 11,780
PIPE INTERNAL YIELD (PSI) 11,200
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 511
BOX OD 2.406”
PIN ID (BORED) 1.930”
INTERNAL YIELD (PSI) 99.6%
COLLAPSE (PSI) 100%
JOINT STRENGTH (MIN PARTING LOAD) 74,000
MAKE-UP LOSS 2.27”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 550
MAKE-UP TORQUE (TARGET) (FT-LBS) 600
YIELD TORQUE (FT-LBS) 1,900

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 1
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

2-3/8” OD, 4.60 LBS/FT, P-110 TUBING w/ HYDRIL 511 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 2-3/8”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 4.60
GRADE P-110
NOMINAL WALL THICKNESS 0.190”
NOMINAL INSIDE DIAMETER 1.995”
DRIFT SIZE 1.901”
TYPE OF UPSET N/A
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 143,000
PIPE YIELD TORQUE (FT-LBS) 7,000
PIPE API COLLAPSE (PSI) 16,130
PIPE INTERNAL YIELD (PSI) 15,400
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 511
BOX OD 2.406”
PIN ID (BORED) 1.930”
INTERNAL YIELD (PSI) 99.6%
COLLAPSE (PSI) 100%
JOINT STRENGTH (MIN PARTING LOAD) 98,000
MAKE-UP LOSS 2.27”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 550
MAKE-UP TORQUE (TARGET) (FT-LBS) 600
YIELD TORQUE (FT-LBS) 2,700

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 2
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

2-7/8” OD, 6.40 LBS/FT, L-80 TUBING w/ HYDRIL 511 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 2-7/8”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 6.40
GRADE L-80
NOMINAL WALL THICKNESS 0.217”
NOMINAL INSIDE DIAMETER 2.441”
DRIFT SIZE 2.347”
TYPE OF UPSET N/A
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 145,000
PIPE YIELD TORQUE (FT-LBS) 8,600
PIPE API COLLAPSE (PSI) 11,170
PIPE INTERNAL YIELD (PSI) 10,570
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 511
BOX OD 2.875”
PIN ID (BORED) 2.377”
INTERNAL YIELD (PSI) 99.4%
COLLAPSE (PSI) 100%
JOINT STRENGTH (MIN PARTING LOAD) 95,000
MAKE-UP LOSS 2.27”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 700
MAKE-UP TORQUE (TARGET) (FT-LBS) 800
YIELD TORQUE (FT-LBS) 2,800

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 3
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

2-7/8” OD, 6.40 LBS/FT, P-110 TUBING w/ HYDRIL 511 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 2-7/8”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 6.40
GRADE P-110
NOMINAL WALL THICKNESS 0.217”
NOMINAL INSIDE DIAMETER 2.441”
DRIFT SIZE 2.347”
TYPE OF UPSET N/A
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 199,000
PIPE YIELD TORQUE (FT-LBS) 11,900
PIPE API COLLAPSE (PSI) 14,550
PIPE INTERNAL YIELD (PSI) 14,530
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 511
BOX OD 2.875”
PIN ID (BORED) 2.377”
INTERNAL YIELD (PSI) 99.4%
COLLAPSE (PSI) 100%
JOINT STRENGTH (MIN PARTING LOAD) 125,000
MAKE-UP LOSS 2.27”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 700
MAKE-UP TORQUE (TARGET) (FT-LBS) 800
YIELD TORQUE (FT-LBS) 3,900

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 4
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

2-7/8” OD, 8.70 LBS/FT, P-110 TUBING w/ HYDRIL 533 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 2-7/8”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 8.70
GRADE P-110
NOMINAL WALL THICKNESS 0.308”
NOMINAL INSIDE DIAMETER 2.259”
DRIFT SIZE 2.165”
TYPE OF UPSET EU
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 273,000
PIPE YIELD TORQUE (FT-LBS) 15,272
PIPE API COLLAPSE (PSI) 21,040
PIPE INTERNAL YIELD (PSI) 20,620
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 533
BOX OD (TURNED) 3.328”
PIN ID (BORED) 2.259”
INTERNAL YIELD (PSI) 100%
COLLAPSE (PSI) 100%
TENSILE EFFICIENCY 100%
MAKE-UP LOSS 3.64”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 2,500
MAKE-UP TORQUE (TARGET) (FT-LBS) 3,000
YIELD TORQUE (FT-LBS) 9,100

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 5
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

3-1/2” OD, 9.20 LBS/FT, L-80 TUBING w/ HYDRIL 511 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 3-1/2”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 9.20
GRADE L-80
NOMINAL WALL THICKNESS 0.254”
NOMINAL INSIDE DIAMETER 2.992”
DRIFT SIZE 2.867”
TYPE OF UPSET N/A
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 207,000
PIPE YIELD TORQUE (FT-LBS) 15,100
PIPE API COLLAPSE (PSI) 10,540
PIPE INTERNAL YIELD (PSI) 10,160
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 511
BOX OD 3.500”
PIN ID (BORED) 2.897”
INTERNAL YIELD (PSI) 100%
COLLAPSE (PSI) 100%
JOINT STRENGTH (MIN PARTING LOAD) 150,000
MAKE-UP LOSS 2.74”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 1,200
MAKE-UP TORQUE (TARGET) (FT-LBS) 1,400
YIELD TORQUE (FT-LBS) 5,600

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 6
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

3-1/2” OD, 9.20 LBS/FT, P-110 TUBING w/ HYDRIL 511 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 3-1/2”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 9.20
GRADE P-110
NOMINAL WALL THICKNESS 0.254”
NOMINAL INSIDE DIAMETER 2.992”
DRIFT SIZE 2.867”
TYPE OF UPSET N/A
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 285,000
PIPE YIELD TORQUE (FT-LBS) 21,000
PIPE API COLLAPSE (PSI) 13,530
PIPE INTERNAL YIELD (PSI) 13,970
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 511
BOX OD 3.500”
PIN ID (BORED) 2.897”
INTERNAL YIELD (PSI) 100%
COLLAPSE (PSI) 100%
JOINT STRENGTH (MIN PARTING LOAD) 197,000
MAKE-UP LOSS 2.74”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 1,200
MAKE-UP TORQUE (TARGET) (FT-LBS) 1,400
YIELD TORQUE (FT-LBS) 7,600

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 7
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

3-1/2” OD, 15.80 LBS/FT, L-80 TUBING w/ HYDRIL 533 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 3-1/2”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 15.80
GRADE L-80
NOMINAL WALL THICKNESS 0.476”
NOMINAL INSIDE DIAMETER 2.548”
DRIFT SIZE 2.423”
TYPE OF UPSET EU
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 362,000
PIPE YIELD TORQUE (FT-LBS) 23,000
PIPE API COLLAPSE (PSI) 18,800
PIPE INTERNAL YIELD (PSI) 19,040
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 533
BOX OD (TURNED) 4.160”
PIN ID (BORED) 2.498”
INTERNAL YIELD (PSI) 100%
COLLAPSE (PSI) 100%
TENSILE EFFICIENCY 100%
MAKE-UP LOSS 4.49”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 7,800
MAKE-UP TORQUE (TARGET) (FT-LBS) 9,000
YIELD TORQUE (FT-LBS) 14,700

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 8
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

4” OD, 9.50 LBS/FT, L-80 TUBING w/ HYDRIL 511 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 4”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 9.50
GRADE L-80
NOMINAL WALL THICKNESS 0.226”
NOMINAL INSIDE DIAMETER 3.548”
DRIFT SIZE 3.423”
TYPE OF UPSET N/A
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 214,000
PIPE YIELD TORQUE (FT-LBS) 18,400
PIPE API COLLAPSE (PSI) 6,590
PIPE INTERNAL YIELD (PSI) 7,910
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 511
BOX OD 4.000”
PIN ID (BORED) 3.454”
INTERNAL YIELD (PSI) 100%
COLLAPSE (PSI) 100%
JOINT STRENGTH (MIN PARTING LOAD) 157,000
MAKE-UP LOSS 2.74”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 1,300
MAKE-UP TORQUE (TARGET) (FT-LBS) 1,500
YIELD TORQUE (FT-LBS) 7,500

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 9
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

4” OD, 11.60 LBS/FT, P-110 TUBING w/ HYDRIL 511 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 4”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 11.60
GRADE P-110
NOMINAL WALL THICKNESS 0.286”
NOMINAL INSIDE DIAMETER 3.428”
DRIFT SIZE 3.303”
TYPE OF UPSET N/A
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 367,000
PIPE YIELD TORQUE (FT-LBS) 31,000
PIPE API COLLAPSE (PSI) 13,160
PIPE INTERNAL YIELD (PSI) 13,760
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 511
BOX OD 4.000”
PIN ID (BORED) 3.334”
INTERNAL YIELD (PSI) 93.6%
COLLAPSE (PSI) 100%
JOINT STRENGTH (MIN PARTING LOAD) 254,000
MAKE-UP LOSS 2.74”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 1,700
MAKE-UP TORQUE (TARGET) (FT-LBS) 2,000
YIELD TORQUE (FT-LBS) 10,300

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 10
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

4-1/2” OD, 15.50 LBS/FT, L-80 TUBING w/ HYDRIL 533 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 4-1/2”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 15.50
GRADE L-80
NOMINAL WALL THICKNESS 0.337”
NOMINAL INSIDE DIAMETER 3.826”
DRIFT SIZE 3.701”
TYPE OF UPSET EU
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 353,000
PIPE YIELD TORQUE (FT-LBS) 33,000
PIPE API COLLAPSE (PSI) 11,080
PIPE INTERNAL YIELD (PSI) 10,480
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 533
BOX OD (TURNED) 4.992”
PIN ID (BORED) 3.776”
INTERNAL YIELD (PSI) 100%
COLLAPSE (PSI) 100%
TENSILE EFFICIENCY 100%
MAKE-UP LOSS 4.09”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 5,800
MAKE-UP TORQUE (TARGET) (FT-LBS) 6,700
YIELD TORQUE (FT-LBS) 21,000

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 11
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

5” OD, 18.00 LBS/FT, L-80 TUBING w/ HYDRIL 511 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 5”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 18.00
GRADE L-80
NOMINAL WALL THICKNESS 0.362”
NOMINAL INSIDE DIAMETER 4.276”
DRIFT SIZE 4.151”
TYPE OF UPSET N/A
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 422,000
PIPE YIELD TORQUE (FT-LBS) 44,000
PIPE API COLLAPSE (PSI) 10,500
PIPE INTERNAL YIELD (PSI) 10,140
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 511
BOX OD 5.000”
PIN ID (BORED) 4.185”
INTERNAL YIELD (PSI) 100%
COLLAPSE (PSI) 100%
JOINT STRENGTH (MIN PARTING LOAD) 315,000
MAKE-UP LOSS 3.62”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 3,500
MAKE-UP TORQUE (TARGET) (FT-LBS) 4,000
YIELD TORQUE (FT-LBS) 18,300

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 12
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE
Saltire Energy Ltd Telephone: (01224) 872228
Badentoy Road Fax: ((01224) 897541
Badentoy Park E mail: enquiries@saltire-energy.com
Portlethen
Aberdeen
AB12 4YA

TUBING SPE CIF ICAT ION SHEET

5” OD, 18.00 LBS/FT, Q-125 TUBING w/ HYDRIL 521 CONNECTIONS

PIPE SPECIFICATION NEW


NOMINAL PIPE OD 5”
NOMINAL WEIGHT (PIPE TUBE) (LBS/FT) 18.00
GRADE Q-125
NOMINAL WALL THICKNESS 0.362”
NOMINAL INSIDE DIAMETER 4.276”
DRIFT SIZE 4.151”
TYPE OF UPSET
PIPE CAPACITIES NEW
PIPE BODY YIELD STRENGTH (LBS) 659,000
PIPE YIELD TORQUE (FT-LBS) 69,000
PIPE API COLLAPSE (PSI) 14,830
PIPE INTERNAL YIELD (PSI) 15,840
C ONNECTION SPECIFICATION NEW
CONNECTION HYDRIL 521
BOX OD (TURNED) 5.359”
PIN ID (BORED) 4.226”
INTERNAL YIELD (PSI) 15,840
COLLAPSE (PSI) 14,820
JOINT STRENGTH (MIN PARTING LOAD) 525,000
MAKE-UP LOSS 3.62”
MAKE-UP TORQUE (MINIMUM) (FT-LBS) 6,100
MAKE-UP TORQUE (TARGET) (FT-LBS) 7,300
YIELD TORQUE (FT-LBS) 18,300

The information on this specification sheet is provided for illustration purposes only and is taken from information available from the
manufacturer and other public sources. Saltire Energy Limited accepts no responsibility or liability for the accuracy of the information
provided or for any error, omission or misstatement. The user is fully expected to review the information for accuracy.

VAT No. 671 1126 64


EU No. EU/0908/147/08
index Registered No. 165384 Page 13
Registered Office: 23 Rubislaw Terrace, Aberdeen AB10 1XE

You might also like