AC - DC DIN Rail Mountable Power Supply

Features
• Universal Input 85V AC to 264V AC
• Short Circuit Protection
• Internal Input Filter
• 3 years warranty

Model List
Model No. Input Voltage Output Wattage Output Voltage Output Current EFF. (Min.) EFF. (Typ.)
Single Output Models
MP-DRAN30-12 +12V DC 2.5A 82% 84%
MP-DRAN30-24 30 WATTS +24V DC 1.24A
83% 86%
MP-DRAN30-48 +48V DC 0.625A
MP-DRAN60-05 85 ~ 264V AC 50 WATTS +5V DC 10A 77% 79%
MP-DRAN60-12 +12V DC 5A 84% 86%
MP-DRAN60-24 60 WATTS +24V DC 2.5A
86% 89%
MP-DRAN60-48 +48V DC 1.25A

Specification
All Specifications Typical At Nominal Line, Full Load, 25°C Unless Otherwise Noticed

General
Characteristics Conditions Min. Typ. Max. Unit
Switching Frequency Vi nom, Io nom 55 135 kHz
Input - Output 3,000 / 4,242
Isolation Voltage Input-FG 1,500 / 2,121 V AC / V DC
Output-FG 500 / 710
Isolation Resistance Input- Output, @ 500V DC 100 MΩ
Ambient Temperature Operating at Vi nom -40 +71 °C
Derating (see Derating
Vi nom, from +61°C to +71°C 2.5 % / °C
curve)
Storage Temperature Non operational -40 +85 °C
Relative Humidity Vi nom, Io nom 20 95 % RH
Temperature Coefficient Vi nom, Io min ±0.03 % / °C

Newark.com/multicomp-pro
Farnell.com/multicomp-pro
Element14.com/multicomp-pro

Page <1> 08/03/21 V1.0


AC - DC DIN Rail Mountable Power Supply

Characteristics Conditions Min. Typ. Max. Unit


MP-DRAN30 12V 640000
Bellcore Issue 6 @40°C, GB 24V 665000
48V 675000
MTBF MP-DRAN60 5V 532000 Hours
Bellcore Issue 6 @40°C, GB 12V 556000
24V 580000
48V 596000
Altitude During Operation EN 62368-1 5,000 m
Dimension Spring terminal type L90 × W40.5 × D114 mm
Cooling Free air convection
Installation Position Vertical (other direction may derating using )
Pollution Degree 2

Input Specifications
Characteristics Conditions Min. Typ. Max. Unit
Rated input voltage Io nom 100 240 V AC
Absolute input max. Ta min ... Ta max, AC in 85 264 V AC
Range Io nom DC in 90 375 V AC
Vi : 115 / 230 V AC, Io nom MP-DRAN30-XX 560 / 330
Input Current MP-DRAN60-XX 1,060 / 590 mA
Vi : 85V AC, Io nom MP-DRAN30 / 60 800 / 1,500
Line Frequency Vi nom, Io nom 47 63 Hz
Vi : 115 / 230V AC , Io nom MP-DRAN30-XX 20 / 40
Inrush current A
MP-DRAN60-XX 30 / 60
Vi : 230 VAC, Io nom 5V 8.5 / 12.5
12V 5.6 / 9
Power Dissipation W
24V 5.5 / 8.8
48V 4.9 / 7.8
Input-Output 0.25 mA
Leakage Current
Input-FG 3.5 mA

Output Specifications
Characteristics Conditions Min. Typ. Max. Unit
Output voltage accuracy
Vi nom, Io max 0 +1
(Adjusted before shipment)
Minimum Load Vi nom 0 %
Line Regulation Io nom, Vi min ...Vi max
±0.5
Load Regulation Vi nom, Io min ...Io nom
MP-DRAN30 & MP-DRAN60 Series 5V 5 5.5
Vi nom, 0.8 Io nom 12V 12 14
Voltage trim Range V DC
24V 24 28
48V 48 55

Newark.com/multicomp-pro
Farnell.com/multicomp-pro
Element14.com/multicomp-pro

Page <2> 08/03/21 V1.0


AC - DC DIN Rail Mountable Power Supply

Characteristics Conditions Min. Typ. Max. Unit


MP-DRAN30 series 12V 2.5A @ 12V DC / 2.1A @ 14V DC
Vi nom 24V 1.25A @ 24V DC / 1.05A @ 28V DC
48V 0.625A @ 48V DC / 0.54A @ 55V DC
Rated continuous loading MP-DRAN60 series 5V 10A @ 5V DC / 9A @ 5.5V DC
Vi nom 12V 5A @ 12V DC / 4.25A @ 14V DC
24V 2.5A @ 24V DC / 2.1A @ 28V DC
48V 1.25A @ 48V DC / 1.08A @ 55V DC
Hold up Time Vi : 115 / 230 V AC , Io nom 20 / 30 ms
Vi nom, Io nom 2,000
Turn on Time ms
Vi nom, Io nom →with Capacitor load 2,000
Vi nom, Io nom 150
Rise Time ms
Vi nom, Io nom →with Capacitor load 500
Fall Time Vi nom, Io nom 150 ms
Transient Recovery Time Vi nom, 1 to 0.5 Io nom 2 ms
Ripple & Noise Vi nom, Io nom, BW = 20MHz 50 mV
MP-DRAN30 & MP-DRAN60 Series 5V 7.5
Vi nom, Io nom 12V 18
Power Back Immunity V DC
1 second 24V 35
48V 63
3,500 /
Capacitor Load Vi nom, Io nom MP-DRAN30 / 60 μF
7,000
Vi nom, Io nom 5V 3.5 4.5
DC ON indicator threshold at 12V 9.0 10.8
V DC
start up (Green LED) 24V 18 21.6
48V 37 43
Up to 89%, See model list and typ
Efficiency Vi nom, Io nom, Po / Pi
efficiency curve

Control and Protection


Characteristics Conditions Min. Typ. Max. Unit
Input fuse T2A / 250V AC internal
Internal surge voltage
IEC 61000-4-5 Varistor
protection
Rated over load protection Vi nom (see typ current limited curve) 110 150 %
Power Rdy
Threshold voltage of contact closed (at start up) 18.8 19.6 V DC
(for 24V model only)
Vi nom, 0.8 Io nom (Auto Recovery) 5V 6 6.8
12V 15 16.5
Over voltage protection V DC
24V 30 33
48V 60 66
Output short circuit Fold forward
Degree of protection IP20

Newark.com/multicomp-pro
Farnell.com/multicomp-pro
Element14.com/multicomp-pro

Page <3> 08/03/21 V1.0


AC - DC DIN Rail Mountable Power Supply

Approvals and Standards


UL 508 Listed
UL / cUL UL 60950-1, UL 1310 Class 2 Power (only 5V and DRAN60-12(A) w/o Class 2) Recognized
ISA 12.12.01(Class I, Division 2, Groups A, B, C and D)
EN 62368-1
TUV
EN 61558-1, EN 61558-2-16 (meet EN 60204-1)
cTUVus UL 62368-1
EN 61000-6-3, EN 55032 Class B, EN 61000-3-2, EN 61000-3-3
EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3
CE EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L / N-FG Level 4
EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11
ENV 50204 Level 2, EN 61204-3
CCC GB4943.1, GB9254, GB17625.1
Vibration resistance meet IEC 60068-2-6 (Mounting on rail : 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis )
Shock resistance meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face)

Physical Characteristics
Case Size 90mm × 40.5mm × 114mm (3.6 inches × 1.59 inches × 4.49 inches)
Case Material Plastic
Weight MP-DRAN30-XX : 270 g MP-DRAN60-XX : 340 g

Mechanism & Pin Configuration


Construction
Easy snap-on mounting onto the DIN-Rail
(TS35/7.5 or TS35/15), unit sits safeIy and firmly
on the rail.
Installation
Ventilation / Cooling Normal convection
All sides 25mm free space For cooling recom-
mended Connector size range
Spring terminal:
AWG 24-14 (0.2~2mm2) flexible / solid cable,
10 m/m stripping at cable end recommends
Screw terminal:
AWG26-12 (0.2~2.5mm2) flexible / solid cable,
connector can withstand torque at maximum
5 pound-inches
4-5m/m stripping at cable end recommends Use
Copper Conductors only, 60/75°C

General Tolerance
0[0.00] - 30[1.18] ±0.3[0.01]
30[1.18] - 120[4.72] ±0.5[0.02]

Dimensions : Millimetres (Inches)

Newark.com/multicomp-pro
Farnell.com/multicomp-pro
Element14.com/multicomp-pro

Page <4> 08/03/21 V1.0


AC - DC DIN Rail Mountable Power Supply

Pin Assignment
Pin No. Designation Description
1 RDY DC OK output for relay (not connect except 24V model)
2 + Positive output terminal
3 Out + Positive output terminal
4 - Negative output terminal
5 - Negative output terminal
6 Ground this terminal to minimize high-frequency emissions
7 In N Input terminals (neutral conductor, no polarity at DC input)
8 L Input terminals (phase conductor, no polarity at DC input)
Vout ADJ Trimmer-potentiometer for Vout adjustment
Other
DC ON Operation indicator LED

Fig. 1 Rdy connection

Circuit Schematic

Typ. Current Limited Curve


MP-DRAN30-XX MP-DRAN60-XX

Newark.com/multicomp-pro
Farnell.com/multicomp-pro
Element14.com/multicomp-pro

Page <5> 08/03/21 V1.0


AC - DC DIN Rail Mountable Power Supply

Derating Curve

TYP. Efficiency Curve

Important Notice : This data sheet and its contents (the “Information”) belong to the members of the AVNET group of companies (the “Group”) or are licensed to it. No licence is granted for
the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change
without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness,
any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make
any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or
where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its
negligence. Multicomp Pro is the registered trademark of Premier Farnell Limited 2019.

Newark.com/multicomp-pro
Farnell.com/multicomp-pro
Element14.com/multicomp-pro

Page <6> 08/03/21 V1.0