Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Rt Red Catalog

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

We care for your needs.

DOWNBLAST ROOF EXHAUSTERS


RT/RE Series

Catalogue ID:
ETC-RT/RE-D 2022-ED01V2
October 2022
DOWNBLAST ROOF EXHAUSTERS

TABLE OF CONTENTS

GENERAL INFORMATION........................................................................................................ 3

CONSTRUCTION FEATURES................................................................................................... 4

OPTIONS & ACCESSORIES..................................................................................................... 5

FAN DATA

Direct Drive....................................................................................................................6-10

Belt Driven...................................................................................................................11-17

ACCESSORIES DIMENSIONS................................................................................................ 18

TYPICAL SPECIFICATIONS................................................................................................... 19

MODEL ORDER CODE: R T xx B D

Roof Top D - Downblast

T - Std. Motor B - Belt Driven


E - External Rotor Motor D - Direct Drive

Impeller Size

2 Energy Twin City, Catalog ETC-RT/RE Downblast


GENERAL INFORMATION
DOWNBLAST ROOF EXHAUSTERS

Overview
RExxDD | RTxxDD | RExxBD | RTxxBD

Energy Twin City’s line of quiet, efficient and economical


spun aluminum centrifugal power roof and wall
exhausters are designed to offer value and long-lasting
service in a wide variety of commercial and industrial
ventilating applications.

STRUCTURAL INTEGRITY
Durable housings of spun aluminum have a high strength-
to-weight ratio and incorporate a rolled bead for additional
strength. There are no welds to break or seams to leak.
The heavy-gauge motor mounting platform provides
positive rigidity between all components of the power
Office Building Application
train assembly.

TYPICAL APPLICATIONS INCLUDE


MOTOR SELECTION
Agriculture, Automotive, Boilers, Brick, Car Wash,
Both direct drive and belt driven models are available
Commercial Plan & Spec, Composting, Ethanol, Food &
with a wide range of voltages and enclosures. Standard
Beverage, Foundry, General Manufacturing, Glass, HVAC,
belt driven TEFC selected using a conservative portion of
Institutional & Hospitality, Metal & Minerals, Microchip,
the IEC/NEMA service factor. Standard direct drive TEAO
OEM, Pharmaceutical, Power Generation, Recycling,
motors have Class B/F insulation and internal thermal
Textile, Transportation
overload protection. Each size is carefully engineered to
match the motor to the impeller capacity.
IMPELLER TYPE
Backward Inclined/Curved Centrifugal
INTERNAL WIRING
ODP/TEAO motors are factory-wired between the motor
OPTIONAL CONSTRUCTION and junction box. For either direct drive or belt driven
Special Coatings, IEC-ex Spark Resistant models, an electric disconnect is available.

EASY MAINTENANCE ACCESS CONFIGURATIONS


By removing the fasteners, the motor dome lifts off for RExxDD (Direct Drive)
complete access to all the drive train components. Available in five sizes – 9.0" to 16.0" impeller diameters
External Rotor Motor

RTxxDD (Direct Drive)


CERTIFICATIONS Available in five sizes – 8.0" to 16.0" impeller diameters
Std. Induction Motor

Energy Twin City certifies that the models RT RTxxBD (Belt Driven)
and RE shown herein are licensed to bear the
AMCA Seal. The rating shown are based on tests
Available in seven sizes – 12.0" to 36.0" impeller diameters
and procedures performed in accordance with Std. Induction Motor
AMCA publication 211 and AMCA publication 311
and comply with the requirements of the AMCA
Certified Ratings Program.

CE Conformity with Low Voltage Directive


2014/35/EU relating to electrical equipment
designed for use within certain voltage limits.

Restriction of Hazardous Substances in Electrical


and Electronic Equipment.

ENERGYINTL.COM 3
CONSTRUCTION FEATURES
DOWNBLAST ROOF EXHAUSTERS

CHAMBER COVER
Provides complete protection for the motor and
drive assembly, while allowing quick access to these
components without the need for tools.

MOTOR CHAMBER
Constructed from heavy-gauge aluminum, rolled and
beaded, for durability and appearance.

MOTORS
ODP, TEFC, TEAO and explosion proof, single and three
phase motors are carefully matched to the fan load.

INTERNAL WIRING
Single phase motors are factory-wired between the
motor and junction box. For either direct drive or belt
driven models, an electric disconnect is available.

BEARINGS
Heavy-duty re-greaseable pillow block ball bearings are
specifically designed for air handling applications to
provide an average life (L-50) of 500,000 hours or more
at maximum cataloged operating speeds.

SHAFT
Precision ground and polished with a first critical speed
of at least 125% of the fan’s maximum operating speed.

DRIVE
Adjustable pitch V-belt drives with cast iron sheaves and
heat resistant belts are selected at 150% of the driven
motor horsepower.

VIBRATION ISOLATION
Motor and drive assembly is completely isolated from the
fan supports by rubber isolators to reduce transmission
of noise and vibration.

IMPELLER
Non-overloading impellers with backwardly curved
blades are precisely matched to a deep spun venture.
All impellers are statically and dynamically balanced to
ensure smooth and quiet operation.

HOUSINGS GALVANIZED BIRD SCREEN


RT and RE housings feature heavy-gauge spun aluminum Protects the impeller, inlet and internal components from
construction of the shroud and top cover. Shrouds feature entry of birds.
a rolled bead edge for rigidity. All housings provide
complete protection of the motor and drive assembly, CURB CAP
while allowing quick access to these components. One-piece curb cap/inlet venture assembly provides
protection from weather. Pre-punched mounting holes
EASY MAINTENANCE ACCESS provide easy and accurate attachment to the roof curb.
By removing the fasteners, the motor chamber and
chamber cover lifts off for complete access to all of the CONDUIT TUBING
drive train components. A conduit tube is furnished for running electrical wiring
through the curb cap and into the motor compartment.

4 Energy Twin City, Catalog ETC-RT/RE Downblast


OPTIONS & ACCESSORIES
DOWNBLAST ROOF EXHAUSTERS

BACKDRAFT DAMPER VARIABLE SPEED CONTROL


With automatic or motorized operation, Allows the adjustment of airflow for
features a felt seal on the edge of the system balancing. Variable speed
damper blades for quiet operation. controllers are solid state design,
Damper frames are constructed of variable speed controls can be shipped
steel and blades are constructed of separately.
aluminum.
NEMA 3R DISCONNECT SWITCH
NEMA 1 DISCONNECT SWITCH Externally mounted when ODP or TEFC
Mounted in the motor compartment motors are used. NEMA 3R, rain proof,
when ODP or TEFC motors used. When disconnects are available shipped
explosion proof motors are specified, loose for field mounting and wiring or
a NEMA 7/9 disconnect switch will be factory mounted and wired.
shipped loose for field mounting and
wiring. NEMA 7/9 DISCONNECT SWITCH
Provided on fans with explosion proof
NEMA 4 DISCONNECT SWITCH motors. The NEMA 7/9 switch is
(OPTIONAL) designed for use with fans operating
Mounted externally and is water- and in hazardous environments. NEMA
dust-tight. Switch is available shipped 7/9 disconnect switch will be shipped
loose for field mounting and wiring or loose for field mounting and wiring.
factory mounted and wired.
VENTED ROOF CURB
ROOF CURB Self-flashing style curbs with ventilation
Constructed of galvanized steel with louvers allow ambient air in to cool
continuous, wide base plate (flashing) and dilute grease- or smoke-laden
to ensure watertight seal to roof, airstreams.
wood nailer secured to top ledge,
lined with fiberglass fire-resistant, ADDITIONAL ACCESSORIES
sound-absorbing insulation. Optional • Special coatings
aluminum construction is available. • AMCA Spark B or C
• Aluminum bird screen
BIRD SCREEN • Stainless steel hardware/accessories
Galvanized mesh is standard. Optional • Insect screen
aluminum or stainless steel rigid wire is
also available.

ENERGYINTL.COM 5
RE SERIES DIRECT DRIVE FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RE09DD
Dimensional Data Performance Curve

Roof Opening
225 x 225
Damper Size
215 x 215
Weight (kg)
20

All dimensions in mm.

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 0.750" Pst 1.000" Pst
Hz KW* A RPM
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
50 0.13 0.55 2450 581 17.5 552 17.5 523 17.5 489 13.7 453 13.7 415 13.7 374 13.7 289 11.0
60 0.17 0.74 2700 585 17.8 549 17.8 512 16.0 469 16.0 420 11.8 369 11.8 320 11.8 246 9.1

1. Performance certified is for installation type A: Free Inlet, Free Outlet.


2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. * Maximum input power

RE10DD
Dimensional Data Performance Curve

Roof Opening
300 x 300
Damper Size
290 x 290
Weight (kg)
21

All dimensions in mm.

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 0.750" Pst 1.000" Pst
Hz KW* A RPM
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
50 0.18 0.78 2800 858 18.9 826 18.9 793 18.9 759 18.9 722 18.9 686 16.3 643 16.3 551 13.3
60 0.22 1.05 2850 947 23 908 23 869 23 829 23 780 23 731 17.6 673 17.6 550 17.6

1. Performance certified is for installation type A: Free Inlet, Free Outlet.


2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. * Maximum input power

6 Energy Twin City, Catalog ETC-RT/RE Downblast


RE SERIES DIRECT DRIVE FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RE12DD
Dimensional Data Performance Curve

Roof Opening
300 x 300
Damper Size
290 x 290
Weight (kg)
22.5

All dimensions in mm.

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 0.750" Pst 1.000" Pst
Hz KW* A RPM
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
50 0.13 0.60 1400 1045 11 977 11 901 11 820 8.8 735 8.8 635 7.1 527 7.1 — —
60 0.18 0.80 1580 1189 14 1112 14 1035 14 952 11.5 862 11.5 764 9.2 670 9.2 500 8.8

1. Performance certified is for installation type A: Free Inlet, Free Outlet.


2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. * Maximum input power

RE13DD
Dimensional Data Performance Curve

Roof Opening
400 x 400
Damper Size
390 x 390
Weight (kg)
25

All dimensions in mm.

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 0.750" Pst 1.000" Pst
Hz KW* A RPM
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
50 0.20 0.88 1340 1396 14.2 1322 14.2 1246 14.2 1166 14.2 1080 12.0 986 12.0 661 12.0 — —
60 0.28 1.25 1380 1485 15.3 1400 15.3 1308 14.2 1206 14.2 1100 14.2 994 11.9 695 11.9 542 11.9

1. Performance certified is for installation type A: Free Inlet, Free Outlet.


2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. * Maximum input power

ENERGYINTL.COM 7
RE/RT SERIES DIRECT DRIVE FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RE16DD
Dimensional Data Performance Curve

Roof Opening
400 x 400
Damper Size
390 x 390
Weight (kg)
29

All dimensions in mm.

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 0.750" Pst 1.000" Pst
Hz KW* A RPM
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
50 0.43 1.50 1380 2144 23 2076 23 2008 23 1936 23 1857 23 1778 19.4 1505 19.4 1288 19.4
60 0.61 1.80 1656 2420 27 2344 27 2268 27 2190 25 2091 25 1992 25 1612 21 1378 21

1. Performance certified is for installation type A: Free Inlet, Free Outlet.


2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. * Maximum input power

RT08DD
Dimensional Data Performance Curve

1
50 Hz
Roof Opening
Stac Pressure in. HO

0.8
225 x 225 60 Hz
Damper Size
215 x 215 0.6
Weight (kg)
20 0.4

0.2
All dimensions in mm.
0
0 50 100 150 200 250 300 350 400
Airflow CFM

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 1.000" Pst 1.500" Pst
Hz KW* A RPM
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
50 0.05 0.53 1292 241 1.4 165 1.7 110 2.5 60 3.5 – – – – – – – –
60 0.05 0.64 1550 284 2.4 190 2.8 140 3.5 92 4.1 53 4.9 – – – – – –

1. Performance certified is for installation type A: Free Inlet, Free Outlet.


2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
4. Model RT08DD, 60 Hz, are not certified by AMCA International.
5. * Maximum input power

8 Energy Twin City, Catalog ETC-RT/RE Downblast


RT SERIES DIRECT DRIVE FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RT10DD
Dimensional Data Performance Curve

1.25
50 Hz
Roof Opening
1 60 Hz

Stac Pressure In. HO


300 x 300
Damper Size
290 x 290 0.75
Weight (kg)
21
0.5

0.25
All dimensions in mm.
0
0 100 200 300 400 500 600 700

Airflow CFM

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 0.750" Pst 1.000" Pst
Hz KW* A RPM
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
50 0.12 0.90 1292 465 4.1 398 4.1 333 4.4 262 4.7 167 4.9 – – – – – –
60 0.12 1.2 1550 555 6.1 500 5.9 442 6.1 393 6.5 325 6.8 266 7.0 179 7.2 – –

1. Performance certified is for installation type A: Free Inlet, Free Outlet.


2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
4. Model RT10DD, 60 Hz, are not certified by AMCA International.
5. * Maximum input power

RT11DD
Dimensional Data Performance Curve

1.5
50 Hz
Roof Opening
1.2 60 Hz
Stac Pressure in. HO

300 x 300
Damper Size
290 x 290 0.9
Weight (kg)
22.5 0.6

0.3
All dimensions in mm.
0
0 200 400 600 800 1000 1200
Airflow CFM

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 1.000" Pst 1.250" Pst
Hz KW* A RPM
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
50 0.26 1.40 1437 830 7.4 741 7.1 646 7.0 546 6.8 443 6.6 320 6.4 – – – –
60 0.26 1.68 1725 992 10.2 918 9.7 845 9.5 761 9.5 595 9.4 505 9.2 291 8.9 – –

1. Performance certified is for installation type A: Free Inlet, Free Outlet.


2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
4. Model RT11DD, 60 Hz, are not certified by AMCA International.
5. * Maximum input power

ENERGYINTL.COM 9
RT SERIES DIRECT DRIVE FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RT13DD
Dimensional Data Performance Curve

1.8
50 Hz
Roof Opening 1.5
60 Hz
300 x 300

Stac Pressure In. HO


Damper Size 1.2
290 x 290
Weight (kg) 0.9
25
0.6

0.3
All dimensions in mm.
0
0 200 400 600 800 1000 1200 1400

Airflow CFM

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 1.000" Pst 1.500" Pst
Hz KW* A RPM
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
50 0.31 1.90 1437 1066 11.6 1001 10.8 931 10.1 861 9.6 791 9.2 710 8.7 – – – –
60 0.31 2.30 1725 1278 16 1222 15 1165 14 1110 14 1055 13 990 12 800 11 625 11

1. Performance certified is for installation type A: Free Inlet, Free Outlet.


2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
4. Model RT13DD, 60 Hz, are not certified by AMCA International.
5. * Maximum input power

RT16DD
Dimensional Data Performance Curve
230V
2.5
50 Hz
Stac Pressure In. HO

Roof Opening 2 60 Hz
400 x 400
Damper Size
1.5
390 x 390
Weight (kg)
29 1

0.5

0
All dimensions in mm. 0 500 1000 1500 2000 2500 3000

Airflow CFM

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 1.000" Pst 1.500" Pst
Hz KW* A RPM
CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones
50 0.86 3.90 1437 2512 13.3 2398 12.8 2296 12.3 2196 11.8 2086 11.4 1955 10.9 1486 10.2 – –
60 0.86 4.70 1725 3015 18 2925 17 2830 16 2750 16 2660 15 2572 15 2251 14 2000 13

1. Performance certified is for installation type A: Free Inlet, Free Outlet.


2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
4. Model RT16DD, 60 Hz, are not certified by AMCA International.
5. * Maximum input power

10 Energy Twin City, Catalog ETC-RT/RE Downblast


RT SERIES BELT DRIVEN FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RT12BD
Dimensional Data Performance Curve
1450 RPM 1300 RPM 1150 RPM 950 RPM
2.1

1.8

Stac Pressure in. HO


1.5

1.2

0.9

0.6

0.3
All dimensions in mm.
0
0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000
Roof Opening Max Mtr. Frame
400 x 400 81 Airflow - CFM
Damper Size Weight (kg)
390 x 390 48

Performance Data
0.000" Pst 0.125" Pst 0.375" Pst 0.500" Pst 0.625" Pst 0.750" Pst 1.000" Pst 1.250" Pst
Motor Fan
CFM CFM CFM CFM CFM CFM CFM CFM
HP RPM
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
1368 1151 – – – – – –
700
9.4 0.06 8.7 0.07 – – – – – – – – – – – –
1/4 1658 1485 1084 769 – – – –
850
11.5 0.11 10.8 0.13 10.2 0.14 9.6 0.12 – – – – – – – –
1853 1703 1371 1155 858 – – –
950
12.9 0.16 12.3 0.17 11.4 0.19 11.0 0.20 10.4 0.19 – – – – – –
2020 1894 1597 1422 1219 930 – –
1/3 1050
13.7 0.21 13.2 0.22 12.2 0.25 11.7 0.26 11.6 0.26 11.2 0.25 – – – –
2146 2023 1740 1591 1408 1197 – –
1100
14.5 0.24 13.9 0.26 12.9 0.29 12.5 0.30 12.3 0.31 12.2 0.31 – – – –
2244 2128 1854 1719 1556 1373 572 –
1150
15.3 0.28 14.7 0.29 13.7 0.33 13.3 0.34 12.9 0.35 12.9 0.36 12.0 0.28 – –
1/2 2439 2333 2077 1963 1831 1676 1300 –
1250
17.2 0.36 16.8 0.37 15.7 0.42 15.1 0.43 14.7 0.44 14.4 0.45 14.5 0.45 – –
2540 2439 2195 2080 1963 1827 1503 869
1300
18.1 0.40 17.6 0.42 16.6 0.46 16.0 0.48 15.4 0.49 14.7 0.51 14.9 0.52 14.5 0.45
2635 2536 2303 2190 2083 1956 1654 1248
1350
18.9 0.45 18.4 0.47 17.4 0.51 16.8 0.53 16.3 0.54 15.7 0.56 15.1 0.58 15.6 0.56
2829 2738 2524 2413 2315 2210 1955 1663
3/4 1450
21.0 0.56 20.0 0.58 19.3 0.62 18.7 0.65 18.2 0.66 17.6 0.68 16.6 0.70 16.6 0.72
2925 2833 2627 2520 2421 2327 2090 1811
1500
22.0 0.61 21.0 0.63 20.0 0.68 19.7 0.71 19.2 0.72 18.7 0.74 17.5 0.77 17.3 0.79

1. Performance certified is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include transmission losses.
2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Values shown are for inlet Lwi sound power levels for installation type A: Free Inlet, Free Outlet.
4. Performance ratings do not include the effects of appurtenances (accessories).

ENERGYINTL.COM 11
RT SERIES BELT DRIVEN FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RT14BD
Dimensional Data Performance Curve
1450 RPM 1350 RPM 1150 RPM 950 RPM
2.4

Stac Pressure in. HO


1.6

1.2

0.8

0.4
All dimensions in mm.
0
Roof Opening Max Mtr. Frame 0 500 1000 1500 2000 2500 3000 3500 4000
400 x 400 90 Airflow - CFM
Damper Size Weight (kg)
390 x 390 48

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 1.000" Pst 1.500" Pst
Motor Fan
CFM CFM CFM CFM CFM CFM CFM CFM
HP RPM
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
2295 2077 1835 1522 1104 – – –
850
9.7 0.15 9.0 0.17 8.3 0.18 7.4 0.18 6.3 0.17 – – – – – –
2606 2415 2226 1977 1699 1355 – –
1/3 950
11.8 0.23 11.2 0.24 10.6 0.26 10.0 0.26 8.8 0.26 7.6 0.25 – – – –
2720 2536 2360 2135 1870 1588 – –
1000
12.6 0.26 12.0 0.27 11.4 0.29 10.8 0.30 9.8 0.30 8.5 0.29 – – – –
2885 2708 2549 2348 2106 1854 – –
1050
13.4 0.31 12.8 0.32 12.4 0.34 11.7 0.35 11.0 0.36 9.8 0.35 – – – –
3155 2995 2847 2683 2484 2257 1251 –
1/2 1150
16.0 0.40 15.5 0.42 15.1 0.44 14.5 0.46 13.8 0.47 12.9 0.47 9.8 0.40 – –
3264 3109 3965 2812 2627 2412 1629 –
1200
17.3 0.45 16.8 0.46 16.3 0.48 15.8 0.50 15.1 0.52 14.4 0.52 10.6 0.49 – –
3577 3435 3306 3173 3019 2844 2238 –
1300
18.7 0.59 18.2 0.60 17.7 0.62 17.3 0.65 16.8 0.67 16.2 0.68 13.3 0.67 – –
3/4
3659 3520 3387 3262 3116 2944 2363 –
1350
19.0 0.63 18.5 0.65 18.1 0.67 17.7 0.69 17.2 0.71 16.6 0.73 14.0 0.72 – –
3808 3675 3546 3426 3293 3140 2587 939
1400
19.9 0.71 19.4 0.73 19.0 0.75 18.6 0.77 18.2 0.79 17.6 0.81 15.5 0.82 13.2 0.53
3942 3816 3689 3574 3451 3309 3783 1848
1 1450
21.0 0.79 21.0 0.81 20.0 0.83 19.7 0.85 19.3 0.87 18.8 0.90 16.8 0.91 14.0 0.85
4075 3951 3826 3714 3602 3465 2974 2200
1500
22.0 0.87 22.0 0.89 21.0 0.91 21.0 0.93 20.0 0.96 19.8 0.98 18.1 1.01 14.6 0.97

1. Performance certified is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include transmission losses.
2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Values shown are for inlet Lwi sound power levels for installation type A: Free Inlet, Free Outlet.
4. Performance ratings do not include the effects of appurtenances (accessories).

12 Energy Twin City, Catalog ETC-RT/RE Downblast


RT SERIES BELT DRIVEN FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RT16BD
Dimensional Data Performance Curve
1150 RPM 950 RPM 850 RPM 750 RPM
2.1

1.8

Stac Pressure in. HO


1.5

1.2

0.9

0.6

0.3
All dimensions in mm.
0
Roof Opening Max Mtr. Frame 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
500 x 500 90 Airflow - CFM
Damper Size Weight (kg)
490 x 490 60

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 1.000" Pst 1.500" Pst
Motor Fan
CFM CFM CFM CFM CFM CFM CFM CFM
HP RPM
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
2971 2772 2552 2323 1948 907 – –
700
10.9 0.25 10.5 0.27 10.1 0.28 9.8 0.29 9.2 0.29 8.9 0.20 – – – –
1/3
3142 2950 2744 2528 2266 1620 – –
750
11.9 0.30 11.6 0.31 11.1 0.33 10.7 0.34 10.3 0.34 9.7 0.31 – – – –
3330 3151 2957 2755 2546 2183 – –
800
12.8 0.35 12.4 0.37 12.0 0.38 11.7 0.40 11.3 0.41 10.6 0.40 – – – –
1/2
3538 3368 3188 3001 2808 2575 – –
850
13.8 0.42 13.5 0.44 13.1 0.46 12.7 0.47 12.3 0.49 11.9 0.49 – – – –
3850 3694 3531 3362 3187 3009 1563 –
900
15.8 0.54 15.4 0.56 15.0 0.58 14.7 0.60 14.3 0.62 13.9 0.63 12.5 0.50 – –
3/4
3954 3803 3642 3481 3311 3138 1972 –
950
16.5 0.59 16.1 0.61 15.8 0.63 15.4 0.65 15.0 0.66 15.0 0.68 13.1 0.60 – –
4266 4126 3982 3831 3676 3518 2880 –
1000
17.9 0.74 17.6 0.76 17.2 0.78 16.9 0.80 16.5 0.82 16.2 0.84 14.6 0.86 – –
1
4500 4366 4231 4088 3943 3794 3299 –
1050
18.9 0.87 18.6 0.89 18.3 0.92 17.9 0.94 17.6 0.96 17.2 0.97 15.9 1.01 – –
4787 4662 4532 4403 4268 4129 3703 2209
1150
21.0 1.04 20.0 1.07 20.0 1.10 19.7 1.12 19.3 1.14 19.0 1.16 17.7 1.21 15.6 1.03
5037 4918 4798 4673 4546 4416 4012 3056
1-1/2 1200
22.0 1.22 22.0 1.24 22.0 1.27 21.0 1.30 21.0 1.32 21.0 1.34 19.3 1.40 16.8 1.36
5166 5055 4933 4812 4688 4563 4170 3398
1250
23.0 1.31 23.0 1.34 22.0 1.37 22.0 1.39 22.0 1.42 21.0 1.44 20.0 1.50 17.8 1.51

1. Performance certified is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include transmission losses.
2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Values shown are for inlet Lwi sound power levels for installation type A: Free Inlet, Free Outlet.
4. Performance ratings do not include the effects of appurtenances (accessories).

ENERGYINTL.COM 13
RT SERIES BELT DRIVEN FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RT18BD
Dimensional Data Performance Curve
750 RPM 950 RPM 1150 RPM 1250 RPM
3

2.5

Stac Pressure in. HO


2

1.5

0.5
All dimensions in mm.
0
0 700 1400 2100 2800 3500 4200 4900 5600 6300 7000
Roof Opening Max Mtr. Frame
500 x 500 100 Airflow - CFM
Damper Size Weight (kg)
490 x 490 64

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 1.000" Pst 1.500" Pst
Motor Fan
CFM CFM CFM CFM CFM CFM CFM CFM
HP RPM
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
4052 3808 3542 3271 2974 2383 – –
1/2 750
13.1 0.39 12.7 0.42 12.2 0.44 11.5 0.46 10.6 0.48 9.7 0.46 – – – –
4345 4115 3868 3618 3357 3010 – –
800
15.2 0.48 14.8 0.51 14.2 0.53 13.7 0.56 12.6 0.58 11.6 0.58 – – – –
4503 4281 4042 3804 3555 3278 – –
3/4 850
15.5 0.53 15.1 0.57 14.6 0.59 14.1 0.62 13.2 0.64 12.2 0.65 – – – –
4804 4595 4376 4151 3923 3684 1675 –
900
17.1 0.65 16.8 0.68 16.3 0.71 15.8 0.74 15.1 0.76 14.3 0.78 12.3 0.59 – –
5081 4886 4682 4469 4255 4034 2875 –
1 950
18.9 0.77 18.7 0.81 18.3 0.84 17.8 0.86 17.3 0.89 16.5 0.92 13.8 0.90 – –
5425 5241 5053 4853 4653 4451 3671 –
1000
21.0 0.93 21.0 0.97 20.0 1.01 19.9 1.04 19.5 1.07 18.9 1.10 16.5 1.12 – –
5610 5431 5251 5058 4865 4671 4006 –
1-1/2 1050
22.0 1.03 21.0 1.07 21.0 1.12 21.0 1.14 20.0 1.17 19.5 1.20 17.3 1.25 – –
5792 5621 5448 5262 5075 4887 4290 –
1100
22.0 1.13 22.0 1.18 22.0 1.23 21.0 1.25 21.0 1.28 20.0 1.31 18.1 1.39 – –
6189 6027 5860 5694 5520 5345 4802 3414
1150
24.0 1.38 24.0 1.43 24.0 1.48 23.0 1.51 23.0 1.54 22.0 1.57 20.0 1.67 17.6 1.60
6321 6162 6004 5838 5667 5495 4967 3786
2 1200
25.0 1.47 25.0 1.52 24.0 1.57 24.0 1.61 23.0 1.64 23.0 1.67 21.0 1.77 18.3 1.77
6594 6443 6291 6134 5970 5806 5307 4399
1250
26.0 1.67 26.0 1.73 26.0 1.78 26.0 1.82 25.0 1.85 25.0 1.88 23.0 1.99 21.0 2.00

1. Performance certified is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include transmission losses.
2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Values shown are for inlet Lwi sound power levels for installation type A: Free Inlet, Free Outlet.
4. Performance ratings do not include the effects of appurtenances (accessories).

14 Energy Twin City, Catalog ETC-RT/RE Downblast


RT SERIES BELT DRIVEN FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RT24BD
Dimensional Data Performance Curve
850 RPM 750 RPM 650 RPM 600 RPM
2.1

1.8

Stac Pressure in. HO


1.5

1.2

0.9

0.6

0.3
All dimensions in mm.
0
Roof Opening Max Mtr. Frame 0 1000 2000 3000 4000 5000 6000 7000 8000 9000
635 x 635 100 Airflow - CFM
Damper Size Weight (kg)
625 x 625 92

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 1.000" Pst 1.500" Pst
Motor Fan
CFM CFM CFM CFM CFM CFM CFM CFM
HP RPM
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
5762 5473 5100 4642 4122 3399 – –
600
13.1 0.52 12.6 0.57 11.9 0.59 11.2 0.62 10.3 0.62 8.2 0.59 – – – –
3/4
6003 5726 5382 4955 4484 3890 – –
625
14.3 0.59 13.7 0.64 13.0 0.67 12.3 0.70 11.6 0.71 9.9 0.69 – – – –
6365 6107 5793 5411 4980 4493 – –
650
14.7 0.71 14.2 0.76 13.7 0.79 13.0 0.82 12.3 0.85 11.4 0.84 – – – –
1
6720 6477 6191 5847 5450 5031 – –
700
15.5 0.83 15.0 0.89 14.5 0.93 13.9 0.96 13.3 0.99 12.6 1.00 – – – –
7200 6974 6720 6425 6063 5680 4113 –
750
17.0 1.02 16.6 1.09 16.1 1.14 15.5 1.16 14.9 1.20 14.3 1.22 11.1 1.15 – –
7439 7222 6984 6697 6360 5992 4619 –
1-1/2 775
17.9 1.13 17.5 1.19 17.1 1.25 16.5 1.27 16.0 1.31 15.4 1.34 12.4 1.30 – –
7725 7519 7296 7022 6713 6374 5182 –
800
19.1 1.27 18.6 1.33 18.1 1.40 17.6 1.42 17.0 1.45 16.5 1.50 14.1 1.48 – –
8155 7963 7750 7505 7235 6912 5851 –
850
19.6 1.49 19.2 1.56 18.8 1.63 18.3 1.66 17.8 1.69 17.2 1.74 15.5 1.77 – –
2
8529 8327 8129 7898 7648 7352 6384 4317
875
21.0 1.69 21.0 1.77 20.0 1.84 19.7 1.89 19.2 1.91 18.6 1.95 17.0 2.04 13.9 1.83

1. Performance certified is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include transmission losses.
2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Values shown are for inlet Lwi sound power levels for installation type A: Free Inlet, Free Outlet.
4. Performance ratings do not include the effects of appurtenances (accessories).

ENERGYINTL.COM 15
RT SERIES BELT DRIVEN FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RT30BD
Dimensional Data Performance Curve
925 RPM 750 RPM 650 RPM 500 RPM
3.2
2.8
2.4

Stac Pressure in. HO


2
1.6
1.2
0.8
0.4
All dimensions in mm.
0
Roof Opening Max Mtr. Frame
0 2500 5000 7500 10000 12500 15000
710 x 710 112 Airflow - CFM
Damper Size Weight (kg)
700 x 700 105

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 1.000" Pst 1.500" Pst
Motor Fan
CFM CFM CFM CFM CFM CFM CFM CFM
HP RPM
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
8040 7642 7195 6674 6071 5324 – –
1 500
14.1 0.73 13.3 0.79 12.4 0.83 11.6 0.87 10.8 0.91 9.9 0.92 – – – –
8661 8295 7890 7427 6927 6303 – –
550
15.4 0.91 14.8 0.98 14.2 1.02 13.4 1.06 12.7 1.12 11.8 1.14 – – – –
1-1/2
9280 8938 8566 8153 7698 7192 4847 –
600
16.8 1.12 16.2 1.19 15.6 1.24 15.0 1.29 14.3 1.34 13.5 1.39 10.4 1.33 – –
10200 9897 9567 9220 8820 8400 6798 –
650
19.1 1.49 18.6 1.57 18.1 1.63 17.6 1.68 17.0 1.73 16.2 1.80 13.4 1.88 – –
2
10471 10168 9842 9513 9129 8724 7235 –
675
19.5 1.61 19.0 1.69 18.6 1.75 18.2 1.80 17.7 1.86 16.9 1.92 14.2 2.03 – –
10981 10692 10392 10073 9723 9346 8011 –
700
20.0 1.86 19.9 1.94 19.5 2.01 19.1 2.06 18.7 2.12 18.1 2.18 15.6 2.32 – –
11755 11480 11210 10910 10611 10263 9120 6886
3 750
22.0 2.28 22.0 2.37 21.0 2.45 21.0 2.51 21.0 2.56 20.0 2.63 17.9 2.83 14.8 2.79
12018 11754 11488 11196 10905 10563 9485 7426
725
23.0 2.44 22.0 2.53 22.0 2.61 22.0 2.67 21.0 2.73 21.0 2.79 18.7 3.01 15.5 3.01
12602 12354 12102 11827 11549 11249 10244 8513
800
24.0 2.81 24.0 2.91 23.0 3.00 23.0 3.06 23.0 3.12 23.0 3.19 21.0 3.42 17.2 3.55
13991 13771 13544 13308 13058 12808 11952 10610
5 900
28.0 3.85 28.0 3.96 28.0 4.06 27.0 4.15 27.0 4.22 27.0 4.28 26.0 4.50 22.0 4.79
14275 14054 13831 13603 13355 13112 12284 11001
925
29.0 4.09 29.0 4.19 29.0 4.30 28.0 4.39 28.0 4.46 28.0 4.53 27.0 4.75 23.0 5.07

1. Performance certified is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include transmission losses.
2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Values shown are for inlet Lwi sound power levels for installation type A: Free Inlet, Free Outlet.
4. Performance ratings do not include the effects of appurtenances (accessories).

16 Energy Twin City, Catalog ETC-RT/RE Downblast


RT SERIES BELT DRIVEN FAN DATA
DOWNBLAST ROOF EXHAUSTERS

RT36BD
Dimensional Data Performance Curve
650 RPM 550 RPM 450 RPM 350 RPM
3.2
2.8
2.4

Stac Pressure in. HO


2
1.6
1.2
0.8
0.4
All dimensions in mm.
0
Roof Opening Max Mtr. Frame 0 2500 5000 7500 10000 12500 15000 17500 20000
915 x 915 132 Airflow - CFM
Damper Size Weight (kg)
905 x 905 200

Performance Data
0.000" Pst 0.125" Pst 0.250" Pst 0.375" Pst 0.500" Pst 0.625" Pst 1.000" Pst 1.500" Pst
Motor Fan
CFM CFM CFM CFM CFM CFM CFM CFM
HP RPM
Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP
10766 10037 9130 8086 6338 – – –
350
11.4 0.65 11.1 0.72 10.2 0.82 9.7 0.87 9.3 0.85 – – – – – –
1
11065 10362 9469 8523 7027 – – –
375
12.0 0.71 11.6 0.78 10.8 0.88 10.1 0.94 9.6 0.93 – – – – – –
11800 11169 10314 9503 8351 – – –
400
13.5 0.86 13.3 0.93 12.5 1.04 11.7 1.11 10.9 1.16 – – – – – –
1-1/2
12680 12115 11324 10586 9711 8478 – –
425
15.5 1.06 15.4 1.15 14.8 1.26 14.0 1.35 13.2 1.42 12.3 1.42 – – – –
13425 12896 12165 11453 10719 9706 – –
450
17.0 1.26 17.0 1.36 16.5 1.46 15.7 1.57 15.0 1.65 14.3 1.71 – – – –
2
14270 13798 13136 12432 11778 10998 – –
475
18.8 1.52 18.8 1.63 18.6 1.71 18.0 1.85 17.2 1.95 16.5 2.02 – – – –
14890 14449 13832 13143 12523 11839 – –
500
21.0 1.72 21.0 1.85 21.0 1.92 20.0 2.07 19.4 2.18 18.6 2.26 – – – –
3
16376 15969 15455 14826 14223 13662 11292 –
550
23.0 2.29 23.0 2.43 23.0 2.50 22.0 2.65 22.0 2.80 21.0 2.91 18.9 3.09 – –
16965 16573 16091 15498 14902 14364 12252 –
575
24.0 2.55 24.0 2.69 24.0 2.77 23.0 2.90 23.0 3.07 22.0 3.20 20.0 3.45 – –
18143 17779 17345 16824 16245 15715 14033 –
5 600
27.0 3.12 27.0 3.27 27.0 3.37 26.0 3.48 26.0 3.66 25.0 3.82 23.0 4.13 – –
19441 19101 18722 18255 17730 17205 15732 12737
650
29.0 3.83 29.0 4.00 29.0 4.13 29.0 4.22 28.0 4.38 28.0 4.57 26.0 4.97 23.0 5.10

1. Performance certified is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include transmission losses.
2. The sound ratings shown are for loudness values in fan sones at 5' (1.5m) in a hemispherical free field per AMCA International Standard 301.
3. Values shown are for inlet Lwi sound power levels for installation type A: Free Inlet, Free Outlet.
4. Performance ratings do not include the effects of appurtenances (accessories).

ENERGYINTL.COM 17
ACCESSORIES DIMENSIONS
DOWNBLAST ROOF EXHAUSTERS

ROOF CURB
MODEL Roof Curb Size
NO. Opening F Sq.
RE09DD 225 x 225 460 x 460
RE10DD 300 x 300 460 x 460
RE12DD 300 x 300 460 x 460
RE13DD 400 x 400 510 x 510
RE16DD 400 x 400 510 x 510
RT08DD 225 x 225 460 x 460
RT10DD 300 x 300 460 x 460
RT11DD 300 x 300 460 x 460
RT13DD 300 x 300 460 x 460
RT16DD 400 x 400 510 x 510
RT12BD 400 x 400 620 x 620
RT14BD 400 x 400 620 x 620
RT16BD 500 x 500 720 x 720
RT18BD 500 x 500 720 x 720
RT24BD 635 x 635 840 x 840
RT30BD 710 x 710 920 x 920
RT36BD 915 x 915 1120 x 1120
All dimensions in mm.

BACKDRAFT DAMPER
MODEL Curb Size
NO. F Sq.
RE09DD 215 x 215
RE10DD 290 x 290
RE12DD 290 x 290
RE13DD 390 x 390
RE16DD 390 x 390
RT08DD 215 x 215
RT10DD 290 x 290
RT11DD 290 x 290
RT13DD 290 x 290
RT16DD 390 x 390
RT12BD 390 x 390
RT14BD 390 x 390
RT16BD 490 x 490
RT18BD 490 x 490
RT24BD 625 x 625
RT30BD 700 x 700
RT36BD 905 x 905
All dimensions in mm.

Notes:
1. All dimensions are in mm unless otherwise noted.
2. Dimensions are not to be used for construction.
3. Damper sizes are nominal.

18 Energy Twin City, Catalog ETC-RT/RE Downblast


TYPICAL SPECIFICATIONS
ROOF EXHAUSTERS, DOWNBLAST

PERFORMANCE
Fans shall be tested in accordance with AMCA Standard 210 and AMCA Standard 300 test codes for air moving devices
and shall be guaranteed by the manufacturer to deliver rated published performance levels. Fans shall be licensed to
bear the AMCA certified ratings seal for both sound and air performance.

CONSTRUCTION
Fans shall be constructed of aluminum for durability and appearance. Fan spinning shall have rolled bead edge for
rigidity. Units shall have a deep venture inlet to prevent snow and rain entry into the building. The curb cap shall include
pre-punched mounting holes for ease of attachment.

INSTALLATION
Fans shall bear a permanently attached nameplate displaying model and serial number of the unit for future identification.

MOTOR ASSEMBLY
RT motors shall be mounted out of the exhaust airstream and RE motors shall be mounted within the exhaust airstream.

IMPELLER
Fan impellers shall be of the centrifugal backward inclined/curved type, constructed of aluminum and containing a
matching inlet venturi for optimum unit performance. Impellers shall be statically and dynamically balanced.

MOTOR
Motors shall be heavy-duty ball bearing type, closely matched to the fan load. All single-phase TEAO motors shall
contain thermal overload protection. Motors for use with speed control shall provide good speed controllability without
any objectionable noise.

FINISH AND COATING


Fans shall be constructed of aluminum. Optional coatings shall be available.

ACCESSORIES
When specified, accessories such as backdraft damper, roof curb, variable speed controller, NEMA 4 disconnect switch,
aluminum bird screen, aluminum insect screen and special coatings shall be provided by Energy Twin City.

FACTORY RUN TEST


Prior to shipment, all fans shall be completely assembled and test run as a unit at operating speed or maximum RPM
allowed for the particular construction type. Each impeller shall be statically and dynamically balanced in accordance
with ISO1940 G 2.5 or 6.3 “Balance Quality and Vibration Levels for Fans."

GUARANTEE
The manufacturer shall guarantee the workmanship and materials for its roof and wall mounted centrifugal exhaust
fans for at least one (1) year from startup or eighteen (18) months from shipment, whichever occurs first.

Energy Twin City reserves the right to make changes at any time, without notice, to models, construction, specifications,
options, availability, etc. This catalogue illustrates the appearance of Energy Twin City products at the time of publication.

ENERGYINTL.COM 19
the recognized leader in
manufacturing and distribution
of hvac and industrial
products in the middle east.

MIDDLE EAST UNITED STATES


PO Box 24021, Sharjah Industrial Area 5959 Trenton Lane, Minneapolis, MN 55442
United Arab Emirates Phone: 763.551.7600 | Fax: 763.551.7601
Phone: 971.6534.3488 | Fax: 971.6534.3710 careers.tcf.com
energyintl.com

You might also like