CL Neutralearthingresistor
CL Neutralearthingresistor
CL Neutralearthingresistor
Dear Sir,
We take this opportunity to introduce ourselves as a manufacturer of various types of Electrical Resistors.
We manufacture following types of resistors: -
1) Neutral Grounding Resistors up to 66 KV for Generators /Transformers
2) Loading Resistors for Generators/Transformers/Ups etc.
3) Load bank for testing of Generators/Transformers/Ups etc.
4) Starting / Speed control Resistors for Crane Motors.
5) Buffer /Slip Resistors for Sugar Industries.
6) LA-SC-PT Panel for Generators
7) Battery Discharge Resistors.
8) Dynamic Breaking Resistors.
9) Neutral side cubicles with CTs /Isolators/Relays etc for DG sets.
10) Phase side cubicles with CT/PT/LA/SC etc. for DG sets.
We are an ISO 9001-2008 certified firm and have a long standing experience in this field.
Considering our expertise and technical know-how, we request you to send your enquiries and give us an
opportunity to fulfill your requirements.
Thanking you.
For NATIONAL RESISTORS
Salient Features
National Resistors
1) Cast Iron Grids are sprayed with heat resistant aluminium paint to have a heat
resistant and anti-corrosive coating.
2) A high thermal time constant permits very high currents to pass in Resistors for short
time durations.
3) Electrical contact surfaces are given a ground finish for better contact between grids to
avoid sparking.
4) Mica tube is provided as an insulation between MS tie rod and grids & mica washers
between alternate grids.Porcelain insulators are used as back - up insulation between
live parts and enclosure in case of high voltages.
o
5) Temperature coefficient of resistance is 0.05% per C Approx. for Cast Iron
6) While assembling tapping can be provided between any adjacent grids to have
desired sectional resistance values.
INFOMRATION TO BE FURNISHED TO US.
1. FOR NEUTRAL GROUNDING RESISTOR :
a) Material of Resistor
b) Ohmic Value
c) Current Rating
d) Duty rating 10 sec., 30 sec., 60 sec., & continuous etc.
e) If details against ‘b’ and ‘c’ cannot be given then inform details of transformer such
as KVA rating, full load current, Primary & Secondary Voltage.
f) System voltage / operating voltage.
g) Type of Enclosure and material for enclosure (protection class as per IS-12063)
h) Location : Indoor or outdoor.
i) Temperature rise allowed over an ambient temperature.
j) Whether space heater, current transformer, isolating switch on load / off load,
manually / motorised, or any other other accessories are required.
Details of atmospheric conditions at site and height above sea level.
NEUTRAL ISOLATOR PANELS (NIS) WITH CT, RELAY. PUNCHED STAINLESS STEEL GRIDS : (Tailor made design is done for each job)