Wing Union PT Model - 425 - Datasheet
Wing Union PT Model - 425 - Datasheet
Wing Union PT Model - 425 - Datasheet
DESCRIPTION
The Model 425 Wing Union Pressure Transmitters are rugged welding process which also ensures hermetic integrity for all
sensors designed for use with 1502 wing unions in demanding field conditions. These transmitters incorporate special assem-
land-based and off-shore applications. bly processes to vibration and shock proof the components to
ensure performance is maintained during the rigors of
The isolated pressure sensing diaphragm minimizes zero shift
fracturing and cementing applications. The 1502 wing union
during hammer-up and eliminates long-term signal drift in the
compatible fittings are machined of Inconel® X-750 providing
field. The sensor diaphragm and wing union fitting are machined
service with highly abrasive and corrosive media. This configura-
as one part. The Model 425 is constructed as an all-welded
tion complies with NACE Standard MR-01-75 (1980) for corro-
assembly using a deep penetration, proprietary, electron beam
sive service.
FEATURES
• Quick delivery service
• Long life X-750 material
• Rugged, robust design
• RFI/EMI protected
• 0.2 % accuracy
• Optional on-board temperature sensor
• Intrinsically safe
• CE approved
Model 425
PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS
Characteristic Measure Characteristic Measure
Pressure ranges 0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi Media Corrosive and abrasive service, Inconel
to 10000 psi; X-750
0 psi to 15000 psi; 0 psi to 20000 psi3 Overload, safe 150 % rated full scale pressure or limit
Accuracy1 ±0.2 % best fit straight line of wing union 1502 fitting
Calibration 5-point calibration: 0 %, 50 %, and 100 Overload, burst 250 % rated pressure or limit of wing
% of full scale union 1502 fitting
Output 4 mA to 20 mA, two-wire Pressure port 1502 wing union, 51 mm [2 in] pipe,
Resolution Infinite male sub end
Wetted parts material Inconel X-750
Weight 2722 g [6 lb]
ENVIRONMENTAL SPECIFICATIONS Case material 316L stainless steel (labels are welded
stainless steel with embossed charac-
Characteristic Measure ters)
Temperature, operating -43 °C to 93 °C [-45 °F to 200 °F]
Temperature, -34 °C to 82 °C [-30 °F to 180 °F]
compensating
RANGE CODES
Temperature effect, zero 0.018 % full scale/°C [0.01 % full Range Code Available ranges
scale/°F] DR 0 psi to 5000 psi
Temperature effect, span 0.018 % reading/°C [0.01 % reading/°F] DS 0 psi to 6000 psi
Temperature effect, sealing Hermetically sealed IP68/NEMA 6P DV 0 psi to 10000 psi
EJ 0 psi to 15000 psi
EL 0 psi to 20000 psi3
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Supply voltage 9 Vdc to 28 Vdc WIRING CODES
Insulation resistance >100 MOhm @ 50 Vdc
Amp (NS), 3-cond, 4 pin, ground
Max. loop resistance 950 ohm @ 28 V decreasing linearly to
A No connection
0 ohm @ 9 V
B (+) Output
Circuit protection Reverse polarity protection of supply
leads C (+) Supply
RFI/EMI protection Noise immunity from 5000 Hz to 1 GHz D Case ground
Frequency response Customer specified and factory in-
stalled filter for frequency response of
min. 10 Hz to max. of 2500 Hz
Zero and span adjustment Field adjustable by removing connector
Electrical termination (std) Standard electrical termination: 4-pin
MS3102 connector designed in stain-
less steel specifically for the oil and gas
industry; offers full hermetic sealing and
direct “Glenair” connector compatibility
Input power (voltage) 9 Vdc to 28 Vdc Pressure 0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to
ranges3 10000 psi; 0 psi to 15000 psi; 0 psi to 20000 psi
Input power (current) 4 mA to 24 mA
Frequency response (amp) 2500 Hz Temperature
-34 °C to 82 °C [-30 °F to 180 °F]
compensation
Power supply rejection 60 db
Operating temperature -43 °C to 93 °C [-45 °F to 200 °F] Internal 2n(2N). 4 mA to 20 mA, two-wire output; intrinsi-
Reverse voltage protection Yes amplifiers cally safe
WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.