CE 318

STRUCTURE ANALYSIS AND DESIGN II LAB


LECTURE 3
STAIR DESIGN

SEMESTER: SPRING 2021


COURSE TEACHER: SAURAV BARUA
CONTACT NO: +8801715334075
EMAIL: saurav.ce@diu.edu.bd

copyright @Saurav Barua 1


LECTURE PLAN

Stair load calculation


Moment calculation
Reinforcement calculation
Stair reinforcement detailing

copyright @Saurav Barua 2


SLAB OUTLINE

copyright @Saurav Barua 3


copyright @Saurav Barua 4
copyright @Saurav Barua 5
LOAD CALCULATION

Assume, waist slab thickness = 6”


Average slab thickness = (6+10)/2 = 8” (thumb rule)
Weight of stair and landing (per ft width)
= 6/12 x 2.67 x 150 + 6/12 x 52 + 8.332 x150 = 200.75 + .5 x 9.71 x 150
= 928.5 lb/ft width = 0.93k/ft
DL = 0.93/11 = 0.085 ksf
LL = 100 psf = 0.1ksf

copyright @Saurav Barua 6


LOAD CALCULATION
Factored load W = 1.4 DL + 1.7 LL = 1.4 x 0.085 + 1.7 x 0.1 = 0.29 ksf

copyright @Saurav Barua 7


MOMENT CALCULATION
±MU = ± 0.29 X 112 /9 = ±3.9 k-ft/ft
þ = 0.016 (previous lecture, fy and fc’ same)
dreq = √(MU/(Ø þ fy b (1-0.59 þ fy/fc’))
= √(3.9/ (0.9 x 0.016 x 60 x 1 x (1- 0.59 x 0.016 x 60/3))
= 2.36”
dprovided = 6-1 (clear cover) = 5”
dreq< dprovided ok

copyright @Saurav Barua 8


REINFORCEMENT

• AS = 3.9 X 12/(0.9 X 60 X (5-1/2)), (assume a =1”)


= 0.19 in2/ft
a = 0.19 x 60/(0.85 x 3 x 12)
= 0.37
AS = 3.9 X 12/ (0.9 X 60 X (5-0.37/2) = 0.18 in2/ft
Temperature and shrinkage rebar
AS, temp = 0.0018 bh = 0.0018 x 12 x 6 = 0.13 in2/ft

copyright @Saurav Barua 9


• AS+VE = 0.18 in2/ft
• AS-VE = 0.18 in2/ft
Main bar,
Use Ø10mm @ spacing = 0.11x 12/0.18 ≈ 7”c/c
For temperature
Use Ø10mm @ spacing = 0.11x 12/0.13 ≈ 10”c/c

copyright @Saurav Barua 10


a = Ø10mm @ 7”c/c
b = Ø10mm @ 10”c/c

copyright @Saurav Barua 11