SOLBERG

®
Filtra�on & Separa�on

“L” Style Compact Vacuum Filters


CSL Series 3/8” - 4”

Benefits
■ Large dirt holding capacity and easy field cleaning,
especially when mounted horizontally or inverted
■ Low pressure design

Features
■ Seamless drawn housings
■ O‐ring seal
■ Corrosive resistant black powder coat carbon steel
■ Stainless steel torsion clips for durability

Technical Specifications
■ Vacuum Rating: medium vacuum service*
■ Temp (continuous): min ‐26°C (‐15°F) max 104°C (220°F)
■ Filter change out differential: 37‐50 mbar over initial ΔP
■ Polyester: 99%+ removal efficiency standard to 5 micron
■ Paper: 99%+ removal efficiency standard to 2 micron

Options ATEX
Available
■ Vacuum gauge
■ Higher holding capacity configurations available
(select models)
■ Material/Finishes: stainless steel, epoxy coating
■ Support brackets
■ Alternative top‐to‐canister fastening system for low
pressure or pulsating systems
■ Stainless steel (select models)

Rev: CSL .38-4-EU1907N


CSL Series 3/8” - 4”

E B

Inlet
A

C
Outlet

Inlet/Outlet Assembly Assembly Part Number Dimensions - mm Suggested Approx. Replacement Element
m³/hr Service Ht. Weight Element Part No. m³/hr
Size Type Rating Polyester Paper A B C D E (kg) Polyester Paper Rating
3/8” BSPP 31 CSL-825-039HCB CSL-824-039HCB 85 54 95 46 76 0.40 825 824 43
1/2” BSPP 31 CSL-825-051HCB CSL-824-051HCB 89 57 95 49 76 0.40 825 824 43
1/2” BSPP 34 CSL-843-051HCB CSL-842-051HCB 103 76 146 64 83 1.4 843 842 94
3/4” BSPP 41 CSL-825-076HCB CSL-824-076HCB 89 58 95 50 76 0.40 825 824 43
3/4” BSPP 43 CSL-843-076HCB CSL-842-076HCB 103 76 146 64 83 1.4 843 842 94
1” BSPP 60 CSL-843-101HCB CSL-842-101HCB 111 83 146 67 83 1.4 843 842 94
1” BSPP 68 CSL-849-101HCB CSL-848-101HCB 170 105 187 114 133 2.3 849 848 196
1 1/4” BSPP 94 CSL-843-126HCB CSL-842-126HCB 111 83 146 67 83 1.4 843 842 94
1 1/4” BSPP 102 CSL-849-126HCB CSL-848-126HCB 170 105 187 114 133 2.3 849 848 196
1 1/2” BSPP 136 CSL-849-151HCB CSL-848-151HCB 171 105 187 114 133 2.3 849 848 196
2” BSPP 298 CSL-851-201HCB CSL-850-201HCB 260 114 222 127 235 6.8 851 850 493
2 1/2” BSPP 357 CSL-851-251HCB CSL-850-251HCB 271 130 222 140 235 6.8 851 850 493
3” BSPP 510 CSL-239-301HCB CSL-238-301HCB 362 184 337 182 279 15 239 238 969
3” NPT 510 CSL-2541-301B CSL-2540-301B 391 216 337 216 305 14 2541 2540 1360
4” NPT 880 CSL-2541-401B CSL-2540-401B 416 242 337 241 305 15 2541 2540 1360

*See Vacuum Filter Technical Data for Vacuum Service Data.

SOLBERG
SOLBERG
®

®
Filtra�on & Separa�on
All model offerings and design parameters are subject to change without prior notice.
Contact your representative or Solberg for the most current information.
SOLBERG
Filtra�on & Separa�on
®

“L” Style Vacuum Filters


CSL Series 3” - 6” BSPT, DN80 - DN300 FLG

Benefits
■ Reduce piping costs with multiple mounting
configurations (mount horizontal or inverted)
■ Minimize equipment pressure-drop change with low
pressure-drop filter design

Features
■ Heavy duty T bolts for easy maintenance
■ Corrosive resistant carbon steel construction
■ Black powder coat finish
■ O‐ring stays in place with unique U-channel groove
■ Inlet & outlet 1/4” gauge taps
■ Lifting lugs
■ Brackets for optional support legs
■ Nameplate bracket

Technical Specifications
■ Vacuum Rating: Medium vacuum service* G B
■ Filter change out differential: 37‐50 mbar over initial ΔP
■ Polyester: 99%+ removal efficiency standard to 5 micron
■ Paper: 99%+ removal efficiency standard to 2 micron
*See Vacuum Filter Technical Data for vacuum service data. Inlet

ATEX
Options Available

■ Straight‐through configurations +
■ Various filter media A
■ Stainless steel E
■ Various nonstandard finishes and D
connection styles F
■ ISO Flange
■ PN6, PN16 flange patterns E
■ Flange faces free of paint
■ Mounting housing bands
C
■ Internal surfaces free of paint
Outlet

Rev: CSL DN80-EU1119N


CSL Series 3” - 6” BSPT, DN80 - DN300 FLG

Flanged Assemblies
Flange Assembly Assembly Part Number Dimensions - mm Suggested Approx. Replacement Element
Inlet & m3/hr Service Ht. Weight Element Part No. m3/hr
Outlet Rating Polyester Paper A B C D E F G kg Polyester Paper Rating
DN80 510 CSL‐235P‐DN80 CSL‐234P‐DN80 695 229 356 470 300 312 305 28 235P 234P 970
DN80 510 CSL‐335P‐DN80 CSL‐334P‐DN80 695 229 356 470 300 312 432 29 335P 334P 1360
DN100 885 CSL‐235P‐DN100 CSL‐234P‐DN100 695 229 356 470 300 312 305 28 235P 234P 970
DN100 885 CSL‐335P‐DN100 CSL‐334P‐DN100 695 229 356 470 300 312 432 29 335P 334P 1360
DN125 1360 CSL‐245P‐DN125 CSL‐244P‐DN125 730 279 470 495 377 347 305 40 245P 244P 1500
DN125 1360 CSL‐345P‐DN125 CSL‐344P‐DN125 730 279 470 495 377 347 432 41 345P 344P 1870
DN150 1870 CSL‐275P‐DN150 CSL‐274P‐DN150 755 305 470 521 377 365 305 50 275P 274P 1870
DN150 1870 CSL‐375P‐DN150 CSL‐374P‐DN150 755 305 470 521 377 365 432 51 375P 374P 2550
DN200 3060 CSL‐377P‐DN200 CSL‐376P‐DN200 991 356 572 648 484 464 432 83 377P 376P 3105
DN250 4930 CSL‐385P‐DN250 CSL‐384P‐DN250 1156 406 686 864 560 598 432 115 385P 384P 5610
DN300 7990 CSL‐485P‐DN300 CSL‐484P‐DN300 1156 406 686 864 560 642 610 125 485P 484P 8000
DN250 4930 CSL‐685P‐DN250 CSL‐384P(2)‐DN250* 1480 406 686 1143 560 820 787 171 685P 384P (2)* 11220
DN300 8415 CSL‐685P‐DN300 CSL‐384P(2)‐DN300* 1480 406 686 1143 560 820 787 171 685P 384P (2)* 11220
DN300 8415 CSL‐485P(2)‐DN300* CSL‐484P(2)‐DN300* 1785 406 686 1448 560 547 610 209 485P (2)* 484P (2)* 16000

See Vacuum Filter Technical Data for sizing guidelines. *Denotes 2 elements stacked in housing.

PN10 Dimensions - mm Flange


Pattern No. of Thickness
Flange O.D. B.C. B.H. Holes mm B.C. O.D.
DN80 200 160 18 8 20 O.D.: Outside Diameter
DN100 220 180 18 8 22 B.C.: Bolt Circle
DN125 250 210 18 8 22 B.H.: Bolt Hole
DN150 285 240 22 8 22 B.H.
DN200 340 295 22 8 24
DN250 395 350 22 12 26
All flanges are orientated “split center”.
DN300 445 400 22 12 26

BSPT Assemblies
BSPT Assembly Assembly Part Number Dimensions - mm Suggested Approx. Replacement Element
Inlet & m3/hr Service Ht. Weight Element Part No. m3/hr
Outlet Rating Polyester Paper A B C D E F G kg Polyester Paper Rating
3” 510 CSL‐235P‐301 CSL‐234P‐301 695 229 356 470 300 312 305 21 235P 234P 970
3” 510 CSL‐335P‐301 CSL‐334P‐301 695 229 356 470 300 312 432 23 335P 334P 1360
4” 885 CSL‐235P‐401 CSL‐234P‐401 695 229 356 470 300 312 305 23 235P 234P 970
4” 885 CSL‐335P‐401 CSL‐334P‐401 695 229 356 470 300 312 432 25 335P 334P 1360
5” 1360 CSL‐245P‐501 CSL‐244P‐501 730 279 470 495 377 347 305 37 245P 244P 1500
5” 1360 CSL‐345P‐501 CSL‐344P‐501 730 279 470 495 377 347 432 40 345P 344P 1870
6” 1870 CSL‐275P‐601 CSL‐274P‐601 755 305 470 521 377 365 305 43 275P 274P 1870
6” 1870 CSL‐375P‐601 CSL‐374P‐601 755 305 470 521 377 365 432 44 375P 374P 2550

See Vacuum Filter Technical Data for sizing guidelines.

SOLBERG
SOLBERG
Filtra�on & Separa�on
®

All model offerings and design parameters are subject to change without prior notice.
Contact your representative or Solberg for the most current information.
Technical Data
Inlet Vacuum Filters

Applications & Equipment Identification


■ Industrial & Severe Duty Standard Solberg assemblies should have an identification
■ Vacuum Pumps & Systems: Roots, Rotary label/nameplate that gives the following information:
Vane, Screw, Piston ■ Assembly Model #
■ Vacuum Packaging Equipment ■ Replacement Element #
■ Vacuum Furnace The part number designates the filter type, the element
■ Blowers: Side Channel & P.D. configuration and housing connection size. For example, the
■ Vacuum Lifters following part number identifies the filter as being a “CSL”
■ Intake Suction Filters design filter with a “235” element, “P” prefilter and DN100
flange connection size.
■ Food Industry
■ Woodworking/Routers
■ Ash Handling CSL-235P-DN100
■ Printing Industry
■ Medical/Hospital Connection Size and Type
■ Remote Installations for Piston & Screw Replacement Element Part Number
Compressors
Filter Type
■ Paper Processing
■ Waste Water Aeration
■ Cement Processing
■ Bag House Systems
■ Vacuum Vent Breathers
Vacuum Service Rating Chart
■ Chemical Processing Threaded vacuum filter connections must be free of defect
■ Factory Automation Equipment and properly sealed to achieve deeper vacuum levels.
Vacuum service levels are given for reference only and serve
■ Leak Detection Systems
as a guideline for product selection. Product certification and
alternative designs are available for applications requiring
deeper vacuum levels and specific leak rates. Please contact
factory for details.

Vacuum Level Pressure (mbar) Pressure (Torr) Pressure (Pa)

Atmospheric Pressure 1013 760 1.013x10+5


Coarse Vacuum 1013 to 33 760 to 25 1x10+5 to 3x10+3
Medium Vacuum 33 to 1.3x10-3 25 to 1x10-3 3x10+3 to 1x10-1
High Vacuum 1.3x10-3 to 1.3x10-9 1x10-3 to 1x10-9 1x10-1 to 1x10-7

Rev: InletVacTech-EU0719K
Inlet Vacuum Filters

Choosing the Best Filter for Your Equipment


A. When the connection & airflow is known:
1. select the appropriate connection style. (i.e.: BSPT, Flange, BSPP, etc.)
2. check assembly m3/hr (flow) rating. Compare with your required airflow.
(Note: Assembly flow ratings are based on 6,000 FPM or 30m/sec for a given connection size to achieve low pressure
drop performance. When required flow exceeds assembly flow rating, the pressure drop through the outlet connection
will increase. In such cases select by element m3/hr (flow) rating.)
3. when required flow rating matches connection size; skip to “C. Selecting Elements”.
B. When the connection size is unknown, flexible, or the required flow rating exceeds assembly flow rating:
1. match required flow rating with the element flow rating.
2. choose related connection size.
C. Selecting Elements: The filter performance is influenced by the actual application duty and the equipment it is installed on.
Regular maintenance checks and proper servicing is required.
Application Duty Descriptions:
Industrial Duty: clean workshop or clean outdoor environment ‐ small element sizing is sufficient.
Severe Duty: dirty workshop, wastewater – medium to large element is recommended.
Extreme Duty: cement, steel making, plastics or dusty material conveying – largest element sizing is recommended.
1. Select media required by your application. Options include:
a. Standard media
1. Polyester: all purpose; withstands pulses, moisture, and oily air
2. Paper: mostly dry, smooth flow applications
b. Special Media: for a variety of micron levels and media types, see the “Filter Media Specifications” in the
Replacement Element Section or contact Solberg.
2. Select element size by matching the element with the anticipated duty and upsize accordingly.

Filter Assembly Maintenance


Request the appropriate maintenance manual for more in‐depth information from your Solberg representative or on our
website: www.solbergmfg.com.

Element Maintenance
Solberg elements should be replaced once the pressure drop reaches 37-50 mbar above the initial pressure drop of the
installation. Cleaning the element is also an option.

Solberg recommends replacing dirty elements for optimal performance. Any damage which results from by‐pass or additional
pressure drop created by element cleaning is the sole responsibility of the operator.

Note: The overall performance of a filter element is altered once cleaned. The initial pressure drop after subsequent cleanings
will be greater than the original, clean pressure drop of the element. After each cleaning, the pressure drop will continue to
increase. Under all circumstances, the initial pressure drop of the element needs to be maintained at less than 37 mbar.

If the pressure drop exceeds 50 mbar at start‐up; it should be replaced with a new element. With many types of equipment,
the maximum pressure drop allowed will be dictated by the ability of the equipment to perform to its rated capacity. Under
all circumstances, the operator should avoid exceeding the manufacturer’s recommended maximum pressure drop for their
specific equipment.