Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

APD 1650 BD

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

APD 1650 BD

INTRODUCTION

Aksa power generation system, providing optimum performance, and reliability, for stationary standby,
prime power, and continuous duty applications. All generator sets are factory build, and production
tested.

Certificate

TS ISO 8528

CE

SZUTEST

2000/14/EC

General Characteristics

Model Name APD 1650 BD

Frequency (Hz) 50

Fuel Type Diesel

Engine Made and Model BAUDOUIN - 12M33G1650/5

Alternator Made and Model Aksa - AK 71250

Control Panel Model DSE 7320

Canopy AK 96-AP1400

Производитель сохраняет за собой право без предварительного уведомления делать изменения в моделях, технических
характеристиках, цветах, оборудовании, аксессуарах и чертежах.

www.aksa.com.tr
APD 1650 BD

3 Phase, 50 Hz, PF 0.8

STANDBY RATING (ESP) PRIME RATING (PRP)

VOLTAGE Standby Amper

kVA kW kVA kW

400/231 1650 1320.00 1550 1240.00 2381.64

STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of
power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not
allowed.

PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is
in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour
perod of operation.

ENGINE SPECIFICATIONS

Engine BAUDOUIN

Engine Model 12M33G1650/5

NO. OF CYLINDERS AND BUILD 12 cylinders - V type

BORE AND STROKE mm 150 X 185

TOTAL DISPLACEMENT L 39,2

Turbo Charged and Air to Air


Aspiration
AfterCooled

Производитель сохраняет за собой право без предварительного уведомления делать изменения в моделях, технических
характеристиках, цветах, оборудовании, аксессуарах и чертежах.

www.aksa.com.tr
APD 1650 BD

COMPRESSION RATIO 15:1

RATED SPEED (RPM) d/dk 1500

OIL CAPACITY L 160

Standby Power (kW/HP) 1450/1944

Prime Power 1350/1810

Block Heater QTY


2

Block Heater Power (Watt)


3000

Fuel Type
Diesel

Injection Type and System


Direct

Type of Fuel Pump


HPCR (High Pressure Common Rail)

Производитель сохраняет за собой право без предварительного уведомления делать изменения в моделях, технических
характеристиках, цветах, оборудовании, аксессуарах и чертежах.

www.aksa.com.tr
APD 1650 BD

Governor System
ECU

Operating Voltage (Vdc)


24 Vdc

Battery and Capacity (Qty/Ah)


4x143

Charge Alternator (A)


55

Cooling Method
Water Cooled

Cooling Fan Air Flow (m3/min)


1380

Coolant Capacity (engine only / with radiator)


(lt)
83/159

Air Filter
Dry Type

Производитель сохраняет за собой право без предварительного уведомления делать изменения в моделях, технических
характеристиках, цветах, оборудовании, аксессуарах и чертежах.

www.aksa.com.tr
APD 1650 BD

Fuel Cons. Prime With %100 Load (lt/hr)


324

Fuel Cons. Prime With %75 Load (lt/hr)


234.2

Fuel Cons. Prime With %50 Load (lt/hr)


156.1

ALTERNATOR SPECIFICATIONS

Manufacturer Aksa

Alternator Made and Model AK 71250

Frequency (Hz) Hz 50

Power (kVA) kVA 1563

DESIGN Brushless

VOLTAGE V 400

Phase 3

Производитель сохраняет за собой право без предварительного уведомления делать изменения в моделях, технических
характеристиках, цветах, оборудовании, аксессуарах и чертежах.

www.aksa.com.tr
APD 1650 BD

A.V.R. MX341

Voltage Regulation (+/-) 1

Insulation System H

Protection IP22

Rated Power Factor 0.8

WEIGHT COMP. GENERATOR (Kg) 3018

COOLING AIR (m³/min) m3 161.4

SIZE and WEIGHT

DRY WEIGHT (kg.) LENGTH WIDTH HEIGHT


Open Type TANK CAPACITY (lt.) (Lt.)
(kg.) (mm.) (mm.) (mm.)

4830 1850 2544 2000

DRY WEIGHT (kg.) LENGTH WIDTH HEIGHT


CANOPY TANK CAPACITY (lt.) (Lt.)
(kg.) (mm.) (mm.) (mm.)

AK 96-AP1400
7500 2300 2495 1900

Производитель сохраняет за собой право без предварительного уведомления делать изменения в моделях, технических
характеристиках, цветах, оборудовании, аксессуарах и чертежах.

www.aksa.com.tr
APD 1650 BD

STANDART SPECIFICATIONS

Water cooled diesel engine


Radiator with mechanical fan
Protective grille for rotating and hot parts
Electric starter and charge alternator
Starting battery (with lead acid) including rack and cables
Engine coolant heater
Steel base frame and anti-vibration isolators
Spare external fuel tank (open set)
Flexible fuel connection hoses
Single bearing, class H alternator
Industrial exhaust silencer and steel bellows supplied separately
Static battery charger
Manual for application and installation
Generators Sets’ voltage and frequency regulation comply with ISO 8528-5

OPTIONAL EQUIPMENTS

ENGINE
• Fuel-Water Seperator Filter
• Oil heater

ALTERNATOR
• Anti-Condensation Heater
• Over sized alternator
• PMG excitation + AVR
• Main line circuit breaker
CONTROL SYSTEM
• Automatic synchronising and power control system ( multi gen-set Parallel )
• Transition synchronization with mains
• Remote annunciator panel
• Remote relay output
• Alarm output relays
• Remote communication with modem
• Earth fault, single set
• Charge Ammeter

TRANSFER SWITCH
• Three Pole Contactor
• Four Pole Contactor

Производитель сохраняет за собой право без предварительного уведомления делать изменения в моделях, технических
характеристиках, цветах, оборудовании, аксессуарах и чертежах.

www.aksa.com.tr
APD 1650 BD

• Three or four pole motor operated circuit breaker

OTHER ACCESSORIES
• Main Fuel Tank
• Automatic or manual fuel filling system
• Manual oil drain pump
• Electrical oil drain pump
• Low and high fuel level alarm
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Trailer
• Tool kit for maintenance
• Automatic transfer switch

INTRODUCTION

Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the
sound requirements and provide optimum protection from inclement weather and development by our
specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for
servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures
are designed to optimize genset cooling performance, providing you with confidence that genset ratings
and ambient capability.

STANDARD SPECIFICATIONS

Compact footprint, low profile design.


Enclosure, generator set, exhaust system and fuel tank are pre-ssembled, pre-integrated and shipped as
one package
Body made from steel components treated with polyester powder coating
Fire retardant foam insulation
Easy access to all service points
Exhaust system inside canopy
Large doors on each side
Control panel viewing window in a lockable access door
Emergency stop push button mounted on enclosure exterior
Cooling fan and battery charging alternator fully guarded
Fuel fill and battery can only be reached via lockable access doors.

Производитель сохраняет за собой право без предварительного уведомления делать изменения в моделях, технических
характеристиках, цветах, оборудовании, аксессуарах и чертежах.

www.aksa.com.tr
APD 1650 BD

Lifting points on the top of canopy and base frame


Customer options available to meet your applications needs.
Aksa makes its generating sets' noise level tests in accordance with directive 2000/14/EC validation of
the noise level test has been aproved by the notified body Szutest

CANOPY MODEL AK 96-AP1400

WIDTH mm. 2300

LENGTH mm. 7500

HEIGHT mm. 2495

TANK CAPACITY (lt.) Lt. 1900

Производитель сохраняет за собой право без предварительного уведомления делать изменения в моделях, технических
характеристиках, цветах, оборудовании, аксессуарах и чертежах.

www.aksa.com.tr