CONTENT

(1)
)CHARACTERISTIC FOR YF-98S……… P2

(2)
)USING OPERATION ……………… P3

(3)
)FRONT PANEL INTRODUCTION ……………… P4-P6

(4)
)USER’S MAINTENANCE ……………… P7

(5)
)ERROR CODE AND SOLUTION ……………… P8-P11

(6)
)WARRANTY P12

Ver. 2 2015
2015.10

-1-
(1)CHARACTERISTIC INTRODUCTION

1. FILM 2.ROLLER 3.LOWER MOULD PLATE 4.CUP JACK


5. LOWER MOULD 6.SAFETY DOOR 7. FRONT PANEL
8. FILM CLAMP 9. TRIANGULAR SLIDING PLATE
10. FILM SENSOR 11.JUMP ROD

一、 Principe:
Use electric plate makes film and container mix together,
then use knife which hidden from upper film to cut off. It
achieve film is pasted up on the container.
二、Patent and special design
○1 Safety device:This machine has safety door. If everything

and hand touch to safety door, the display monitor will show
“E07”, then lower mould recoil immediately recoil and
prevent accidents to cut the finger.
○2 Jump Rod:This device can help container which the same caliber,

different depth to sealing. Make it jump at the same time.


User can easy to pick up the container.
○3 Auto detect:Panel can detect any failures. Help the user to

fix.
二、 The sequence of machine motion:○
1 Put cap on the lower mould.

○2 Auto(or manual)sealing. ○
3 Film motor rewinding. ○ 4 Upper

mould push down to sealing and cut the rim. ○ 5 Cap out put.

○6 pick the cup.

-2-
(2)USER’S OPERATION

1. Fill in the film in correct direction as the above picture. If you fill in the wrong
way, the film would be stuck with the heater of upper mould.After loading the film,
please match the eye-mark of film to the place of film sensor.
2. Plug the AC power wire, turn on the power botton, the lower mould will push out
at the same time. Further, the upper mould will be increasing the temperature
automatically.
3. After 5~7 minutes, the TEMPERATURE INDICATIR shall shut off when the upper mould’s
temperature set ready. Till now, the auto function is ready for work. It could
be only in manual while the temperature is not ready.
4. The way to choose the container and film:
(1)PET/ES film is suitable for any kind of trays. (temperature range 140~160°C)
(2)As for sealing well, the material of both container and film should be the same.
(temperature range 160~180°C)

※PS:
PS:Unemployed and children are forbidden to close to the machines.
don’t put hands in the machines unless you pull
To forbidden the accident, don’
out the power wire.

-3-
《3》FRONT PANEL INTRODUCTION
I. Indicator

II. Function of buttons:


buttons:
(1)Power indicator:
indicator Indicating the power is online or offline.
(2)Power
Power key:
key Press power key to start up the machine. After displaying
“YF-LCC”pattern, the machine begins to service you. Oppositely,“PO”
pattern means the power is off.
(3)Auto/Manual
Auto/Manual choice key:
key: Providing you to select auto or manual operation;
A. If manual is selected, the machine is
waiting for pressing the manual key to go on
sealing process.
B. If auto is selected, the machine is
automatically doing sealing process.
(Cups will be sealed automatically.)
4.Manual
Manual Operate KEY:
KEY Work in situation 3-A.
5.Reset
Reset key: Reset the function of microcomputer’s parameters, and special
function.
6.Temperature
Temperature Key:
Key Lighting up as increasing temperature, off oppositely.
7.Right
Right screen: A. To display the temperature as usual condition.
B. To display the parameter of function as changing the
parameter setting.
C. To display error code.
8.〝
〝UP〞
UP〞 and 〝DOWN〞
DOWN〞Keys:
Keys To increase or decrease one unit value.
9.Counter
Counter Key: To display the amount or count back to zero.
10.Left
Left screen:
screen A. To display the amount as usual condition.
B. To display the parameter setting. Symbolizing P1~P5.
-4-
I. LED Indicator
Indicator

ET-
ET-999SN ET-
ET-95SN ET-
ET-99SU ET-
ET-99MU

1. : LOWER MOULD/CUP INPUT

2. : UPPER MOULD SEALING

3. : UPPER MOULD STANDBY

4. : LOWER MOULD/CUP OUTPUT

5. : FILM REWINDING

6. : SECURITY DOOR ERROR

7. : EYE-
EYE-MARK SENSING

8. : TEMP HEATING

9. : MANUAL
MANUAL MODE OPERATION

10. : AUTO MODE OPERATION


11. :YF LED LOGO Indicating the power is online.
-5-
III. Function of setting
1. System parameter table:
Symbol Function Range Parameter Setting
Setting (Set in factory)
Set PP(160~180℃)ES(140~160℃) 160℃
P1
Temperature
P2 Counter LOK: LOCK / OPN: UNLOCK N (can be reset)
Sealing 001~030 unit (0.1sec~3sec) 010 unit (1sec)
P3
time
Cup settled 000~030 unit (0.0sec~3sec) 010 unit (1sec)
P4
time
Film 000~060 unit (0.1sec~6sec) 000(controlled by
P5 rolling sensor)
time
IV.Operating procedures:
The procedures of machine as: A->B->C->D->E->F->G->H->I
A. Press POWER to display YF/LCC, then left screen shows counter and right screen shows
TEMP. The machine is now ready for using.
B. Press SET key, the left screen displays P1,the right screen displays temperature,
then use up or down Key to increase or decrease one degree.(PP film 160~180℃,
ES film 140~160℃)
C. Press SET Key, then the left screen display P2, the right screen shows counting
mode, OPN means can be reset to zero and recounting from one,LOK means cannot be
reset to zero, but continuously counting day after day.
D. Press SET key once more, the left screen shows P3, and right screen shows
sealing time, then use up and down key to increase or decrease the value by one
unit (0.1 second). Generally, the value is assigned between 005 and 015.
E. Press SET key once more, the left display shows P4, and right display shows cup
settling time, then use up and down key to increase or decrease the value by one
unit (0.1 second). Generally, the value is assigned between 005 and 010.
F. Press SET key once more, the left display shows P5 , and right display shows
plastic paper advancing time. If the paper has a sensed point (eye mark), then set
the value at 000, else depends on the length of the paper unit, and use up and down
key to adjust the correct time, generally, is set around 006 and 020.
Press SET key once again, the left display shows YF, and right display shows LCC,
means all set procedures are finished. The left display goes to normal
-6-
《4》USER’S
USER S MAINTENANCE

Any time do maintenance, should un-plug the AC power wire.

G. Daily check point


(1) Check the upper mould and clean by wet cloth or rough plastic sheet. If not, the
dirty plastic sheet or powder will stick on the heating plate.
(2) Keep both the right and left slider those fixed under the lower mould plate clean
and lubricated, if not, the input and output of the lower mould operation will be
unsmooth.
(3) Clean the groove of the lower mould.
(4) Clean the jack system. (Jack slider, spring roller, bearing etc), keep it operate
smoothly.
(5) Clean the film sensor and lower mould in-out sensor.

II. Other maintenance and repair placement:


Please contact with your local dealer for service and cooperate with the
maintenance staff.

-7-
-1
Maintenance-

ERROR CODE AND SOLUTION :

1 E00 Temperature control system error.

2 E01 Heating circuit or temperature wire error.

3 E02 Upper motor or micro switch of upper mould error.

4 E03 Lower motor or micro switch of lower mould error.

Sealing film is not in the right position or the eye-mark


5 E04 sensor error.

6 E05 Lower motor or micro switch of lower mould error.

7 E06 Upper motor or micro switch of upper mould error.

8 E07 Safety door is touched or collided.

9 E19 PCB error:The main control system of PCB error PCB crashed.

10 E20 Short of DC12V.

11 Err Voltage error.

12 E12 Upper motor of film rise error.(Reducer, Web, bolt loose or circuit error.)

Lower motor of film stretch out error. (Reducer, pull rod, bolt loose or
13 E13 circuit error.)

Lower motor of film enter error. (Reducer, pull rod, bolt loose or circuit
14 E15 error.)
Upper motor of film under pressure error. (Reducer, webs, bolt loose or
15 E16 circuit error.)

-88-
-2
Maintenance-

ERROR CODE AND SOLUTION :


Cannot in-put the containers under Auto setting :
1. The film sensor of lower mould is too strong or too weak. please
clean the sensor or adjust the degree of sensor.
12 2. The black paint on lower mould is peeled off. Please paint it
again smoothly. Change a film sensor if above adjustment is useless.

Cannot seal the container smoothly :


1. Clean up the surface of upper mould.
2. defacement of lower mould or silicon rubber.
3. Deformation of the containers.
4. To increase the temperature or adjust the time for sealing.
5. The springs of upper mould is broken, so that the pressure is not
at average. (it occurs about sealing 100 thousand times.)
13 6. The springs of heater is broken, so that the pressure in not at
average.(it occurs about sealing 300 thousand times.)
The knife of upper mould is stuck. Please ask the technical staffs to
clean up the knife. Wrong use of film material: Sealing paper
containers with PP film.(WRONG)Sealing Styrofoam containers with
ES film.(WRONG)

Film stops before sealing but PCB has no error code :


1. Clean up the film sensor.
2. To adjust the degree of the film sensor stronger.
14 3. To change a new film sensor as it is broken.
PCB crashed.

No power of the machine :


1. Please plug the AC power wire.
15 2. The fuse of PCB is broken.
3. The short terminal of PCB is loosen.

-99-
-3
Maintenance-

ERROR CODE AND SOLUTION :


Wrong position of the containers :
16 To use lubricant on slide and jump rod everyday.

Cannot cut down the film:


1. To clean the surface of the upper mould.
2. Please ask the technical staffs to clean up the knife of upper
mould.
3. Defacement of lower mould or silicon rubber.
17 4. Adjust the depth of pressing for upper mould.
5. The springs of upper mould is broken, so that the pressure is not
at average.
6. The PET film is too thick to cut down.
7. The knife of upper mould is not sharp enough or broken.

18 The lower mould lodge when sealing was finished :


The micro switch is stuck by fructose. Please clean up the switch.
19 Shortage of voltage :
1. The extended line is too thin.
2. Conjoint with too many other electric machines for one extended
line.

The safety door is crushed by the containers while sealing :


1. The jack rod collide with the inner edge of lower mould.
20 2. Clean up the jump rod/bar and use lubricant on it.
3. Change a new spring of jump rod as it is broken.

The film is not in the right position or turning around and around :
21 Please avoid to put the sealing machine under the sunshine directly,
or it would cause the misunderstanding of in-put and film sensor.

10-
10
-10
圖一
-11-
Warranty Statement
Statement
Content:
Content:
Warranty Certificate
Date of delivery:__________________________

Customer:

Address:


Tel.: Fax/Email::

Model No: M/C No.::

Inspection: Annotation
1. Here we grant one year free service
since the date of delivery. We will offer
service of free maintenance and parts
change.
2. Damages caused by natural disaster,
re-equip without consulting with the
dealer, due to operator's fault or wrong
operation to make it malfunctioned or
damaged, 、a malfunction caused by
move or shift would be charged for
parts and repair placement.
3. It would be charged for parts and repair
placement one year after delivery.

Authorized by

※The contract would be avoid without authorization.


Model
YF-98S
capacity
110V/220V
Voltage
50/60Hz
Duty 400W

Weight 22kg
Size(mm) 350X360X610