Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

CC-5 MSDS English content

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Page 1/9

Safety data sheet


Regulation (EC) No. 1907/2006 and 1272/2008
Printing date 21.01.2022 Version number 1 Revision: 20.01.2022

SECTION 1: Identification of the substance/mixture and of the company/undertaking


· 1.1 Product identifier
· Trade name: Automatic Hematology Analyzer CC-5 Cell Clean A(CC-5)
· 1.2 Relevant identified uses of the substance or mixture and uses advised against
· Application of the substance / the mixture:
The product is used as a clean solution for the maintenace of hematology analyzer
· 1.3 Details of the supplier of the safety data sheet
· Manufacturer / Supplier: MACCURA BIOTECHNOLOGY CO.,LTD.
· Full address:
16# BAICHUAN ROAD, HI-TECH ZONE, 611731 CHENGDU, PEOPLE’S REPUBLIC OF CHINA
· Phone number: +86 28 87826777
· Email: maccura@maccura.com
· Only Representative / other EU contact point: Not available
· Further information obtainable from: MACCURA BIOTECHNOLOGY CO.,LTD.
· 1.4 Emergency telephone number:
GERMANY
Poison Center Berlin - Institute of Toxicology
Tel: +49 030 192 40
· 1.5 Reference Number: CANEC2201228901,22366869 CQ

SECTION 2: Hazards identification


· 2.1 Classification of the substance or mixture
· Classification according to Regulation (EC) No 1272/2008

GHS05 corrosion

Skin Corr. 1B H314 Causes severe skin burns and eye damage.
Eye Dam. 1 H318 Causes serious eye damage.

GHS09 environment

Aquatic Acute 1 H400 Very toxic to aquatic life.


Aquatic Chronic 1 H410 Very toxic to aquatic life with long lasting effects.
· Information concerning particular hazards for human and environment:
The product has to be labelled due to the calculation procedure of Regulation (EC) No.1272/2008.
· Classification system:
The classification is according to the latest edition of EU Regulation (EC) No. 1272/2008, and extended by
company and literature data.
· 2.2 Label elements
· Labelling according to Regulation (EC) No. 1272/2008
The product is classified and labelled according to the CLP regulation.
· Hazard pictograms

GHS05 GHS09

· Signal word Danger


(Contd. on page 2)
EU

51.1.17
Page 2/9
Safety data sheet
Regulation (EC) No. 1907/2006 and 1272/2008
Printing date 21.01.2022 Version number 1 Revision: 20.01.2022

Trade name: Automatic Hematology Analyzer CC-5 Cell Clean A(CC-5)

(Contd. of page 1)

· Hazard-determining components of labelling:


sodium hypochlorite, solution
· Hazard statements
H314 Causes severe skin burns and eye damage.
H410 Very toxic to aquatic life with long lasting effects.
· Precautionary statements
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with
water [or shower].
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if
present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER/doctor.
P321 Specific treatment (see on this label).
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international
regulations.
· Additional information:
EUH031 Contact with acids liberates toxic gas.
· 2.3 Other hazards:
· Results of PBT and vPvB assessment
· PBT: Not applicable.
· vPvB: Not applicable.

SECTION 3: Composition/information on ingredients


· 3.2 Mixtures
· Description:
Mixture of the substances listed below with nonhazardous additions.
For the wording of the listed hazard statements refer to section 16.
· Composition:
CAS: 7681-52-9 sodium hypochlorite, solution 99.98%
EINECS: 231-668-3 Skin Corr. 1B, H314; Eye Dam. 1, H318; Aquatic Acute 1,
Index number: 017-011-00-1 H400; Aquatic Chronic 1, H410
CAS: 6381-92-6 Glycine, N,N'-1,2-ethanediylbis[N-(carboxymethyl)-, sodium salt, 0.02%
hydrate (1:2:2)
STOT RE 2, H373; Acute Tox. 4, H332

SECTION 4: First aid measures


· 4.1 Description of first aid measures
· General description: Immediately remove any clothing soiled by the product.
· After inhalation: In case of unconsciousness place patient stably in side position for transportation.
· After skin contact: Immediately wash with water and soap and rinse thoroughly.
· After eye contact: Rinse opened eye for several minutes under running water. Then consult a doctor.
· After swallowing: Drink plenty of water and provide fresh air. Call for a doctor immediately.
· 4.2 Most important symptoms and effects, both acute and delayed:
No further relevant information available.
· 4.3 Indication of any immediate medical attention and special treatment needed:
No further relevant information available.
EU
(Contd. on page 3)

51.1.17
Page 3/9
Safety data sheet
Regulation (EC) No. 1907/2006 and 1272/2008
Printing date 21.01.2022 Version number 1 Revision: 20.01.2022

Trade name: Automatic Hematology Analyzer CC-5 Cell Clean A(CC-5)

(Contd. of page 2)

SECTION 5: Firefighting measures


· 5.1 Extinguishing media
· Suitable extinguishing agents: Use fire extinguishing methods suitable to surrounding conditions.
· 5.2 Special hazards arising from the substance or mixture:
During heating or in case of fire poisonous gases are produced.
· 5.3 Advice for firefighters
· Protective equipment: Mouth respiratory protective device.

SECTION 6: Accidental release measures


· 6.1 Personal precautions, protective equipment and emergency procedures:
Mount respiratory protective device.
Wear protective equipment. Keep unprotected persons away.
· 6.2 Environmental precautions:
Do not allow product to reach sewage system or any water sourse.
Inform respective authorities in case of seepage into water course or sewage system.
Dilute with plenty of water.
Do not allow to enter sewers/ surface or ground water.
· 6.3 Methods and material for containment and cleaning up:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Use neutralising agent.
Dispose contaminated material as waste according to section 13.
Ensure adequate ventilation.
· 6.4 Reference to other sections:
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.

SECTION 7: Handling and storage


· 7.1 Precautions for safe handling:
Ensure good ventilation/exhaustion at the workplace.
Prevent formation of aerosols.
For the general occupational hygienic measures refer to Section 8.
· Information about fire - and explosion protection: Keep respiratory protective device available.
· 7.2 Conditions for safe storage, including any incompatibilities
· Requirements to be met by storerooms and receptacles: No special requirements.
· Information about storage in one common storage facility: Do not store together with acids.
· Further information about storage conditions: Keep container tightly sealed.
· 7.3 Specific end use(s): No further relevant information available.

SECTION 8: Exposure controls/personal protection


· 8.1 Control parameters
· Ingredients with limit values that require monitoring at the workplace:
The product does not contain any relevant quantities of materials with critical values that have to be
monitored at the workplace.
· DNELs: Not available
· PNECs: Not available
(Contd. on page 4)
EU

51.1.17
Page 4/9
Safety data sheet
Regulation (EC) No. 1907/2006 and 1272/2008
Printing date 21.01.2022 Version number 1 Revision: 20.01.2022

Trade name: Automatic Hematology Analyzer CC-5 Cell Clean A(CC-5)

(Contd. of page 3)

· Additional information: The lists valid during the making were used as basis.
· 8.2 Exposure controls
Based on the composition shown in Section 3, the following measures are suggested for occupational safety
measure.
· Appropriate engineering controls:
Keep away from foodstuffs, beverages and feed.
Immediately remove all soiled and contaminated clothing
Avoid contact with the eyes.
Avoid contact with the eyes and skin.
See Section 7 for information about design of technical facilities.
· Personal protective equipment
· Respiratory protection:
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer
exposure use self-contained respiratory protective device.
· Protection of hands:

Protective gloves

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/
the chemical mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the
degradation.
· Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of
quality and varies from manufacturer to manufacturer. As the product is a preparation of several
substances, the resistance of the glove material can not be calculated in advance and has therefore to be
checked prior to the application.
· Penetration time of glove material:
The exact break through time has to be found out by the manufacturer of the protective gloves and has to be
observed.
· Eye protection:

Tightly sealed goggles

· Environmental exposure controls:


Control measures must be made in accordance with Community environmental protection legislation.

SECTION 9: Physical and chemical properties


· 9.1 Information on basic physical and chemical properties
· Appearance
Form: Liquid
Colour: Light yellow
· Odour: It smells like chlorine
· Odour threshold: Not available
· pH-value: Not available
· Change in condition
Melting point/Freezing point: Not available
Initial boiling point and boiling range: Not available
(Contd. on page 5)
EU

51.1.17
Page 5/9
Safety data sheet
Regulation (EC) No. 1907/2006 and 1272/2008
Printing date 21.01.2022 Version number 1 Revision: 20.01.2022

Trade name: Automatic Hematology Analyzer CC-5 Cell Clean A(CC-5)

(Contd. of page 4)

· Flash point: Not available


· Flammability (solid, gas): Not available
· Auto-ignition temperature: Not available
· Decomposition temperature: Not available
· Self-igniting: Not available
· Explosive properties: Not available
· Explosion limits
Lower: Not available
Upper: Not available
· Oxidising properties: Not available
· Vapour pressure: Not available
· Density: Not available
· Relative density: Not available
· Vapour density: Not available
· Evaporation rate: Not available
· Solubility in / Miscibility with
water: Not available
· Partition coefficient: n-octanol/water: Not available
· Viscosity
Dynamic: Not available
Kinematic: Not available
· 9.2 Other information No further relevant information available.

SECTION 10: Stability and reactivity


· 10.1 Reactivity: Data not available
· 10.2 Chemical stability: Data not available
· 10.3 Possibility of hazardous reactions: Contact with acids releases toxic gases.
· 10.4 Conditions to avoid: No further relevant information available.
· 10.5 Incompatible materials: No further relevant information available.
· 10.6 Hazardous decomposition products: No dangerous decomposition products known.

SECTION 11: Toxicological information


· 11.1 Information on toxicological effects
· Acute toxicity Based on available data, the classification criteria are not met.
· LD/LC50 values relevant for classification:
7681-52-9 sodium hypochlorite, solution
Oral LD50 5,800 mg/kg (mouse)
· Skin corrosion/irritation:
Causes severe skin burns and eye damage.
· Serious eye damage/irritation:
Causes serious eye damage.
· Respiratory or skin sensitization: Based on available data, the classification criteria are not met.
· Germ cell mutagenicity Based on available data, the classification criteria are not met.
(Contd. on page 6)
EU

51.1.17
Page 6/9
Safety data sheet
Regulation (EC) No. 1907/2006 and 1272/2008
Printing date 21.01.2022 Version number 1 Revision: 20.01.2022

Trade name: Automatic Hematology Analyzer CC-5 Cell Clean A(CC-5)

(Contd. of page 5)
· Carcinogenicity Based on available data, the classification criteria are not met.
· Reproductive toxicity Based on available data, the classification criteria are not met.
· STOT-single exposure Based on available data, the classification criteria are not met.
· STOT-repeated exposure Based on available data, the classification criteria are not met.
· Aspiration hazard Based on available data, the classification criteria are not met.

SECTION 12: Ecological information


· 12.1 Toxicity
· Aquatic toxicity: No further relevant information available.
· 12.2 Persistence and degradability: No further relevant information available.
· 12.3 Bioaccumulative potential: No further relevant information available.
· 12.4 Mobility in soil: No further relevant information available.
· 12.5 Results of PBT and vPvB assessment
· PBT: Not applicable.
· vPvB: Not applicable.
· 12.6 Other adverse effects No further relevant information available.
· 12.7 Additional ecological information:
· General notes:
Water hazard class 2 (German Regulation) (Self-assessment): hazardous for water
Do not allow product to reach ground water, water course or sewage system.
Must not reach sewage water or drainage ditch undiluted or unneutralised.
Danger to drinking water if even small quantities leak into the ground.
Also poisonous for fish and plankton in water bodies.
Very toxic for aquatic organisms

SECTION 13: Disposal considerations


· 13.1 Waste treatment methods
· Recommendation:
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
· Uncleaned packaging
· Recommendation: Disposal must be made according to official regulations.
· Recommended cleansing agents: Water, if necessary together with cleansing agents.

SECTION 14: Transport information


· 14.1 UN-Number
· ADR/RID/ADN, IMDG, IATA UN1791
· 14.2 UN proper shipping name
· ADR/RID/ADN HYPOCHLORITE SOLUTION mixture,
ENVIRONMENTALLY HAZARDOUS
· IMDG HYPOCHLORITE SOLUTION mi xt ure , MAR INE
POLLUTANT
· IATA HYPOCHLORITE SOLUTION mixture
(Contd. on page 7)
EU

51.1.17
Page 7/9
Safety data sheet
Regulation (EC) No. 1907/2006 and 1272/2008
Printing date 21.01.2022 Version number 1 Revision: 20.01.2022

Trade name: Automatic Hematology Analyzer CC-5 Cell Clean A(CC-5)

(Contd. of page 6)

· 14.3 Transport hazard class(es)


· ADR/RID/ADN, IMDG

· Class 8 Corrosive substances.


· Label 8
· IATA

· Class 8 Corrosive substances.


· Label 8
· 14.4 Packing group
· ADR/RID/ADN, IMDG, IATA II
· 14.5 Environmental hazards Product contains environmentally hazardous substances:
sodium hypochlorite, solution
· Marine pollutant: Symbol (fish and tree)
· Special marking (ADR/RID/ADN): Symbol (fish and tree)
· 14.6 Special precautions for user: Warning: Corrosive substances.
· Hazard identification number (Kemler code): 80
· EMS Number: F-A,S-B
· Segregation groups Hypochlorites
· Stowage Category B
· Segregation Code SG20 Stow "away from" SGG1-acids
· 14.7 Transport in bulk according to Annex II of
Marpol and the IBC Code Not applicable
· 14.8 Transport/Additional information:
· ADR/RID/ADN
· Limited quantities (LQ): 1L
· Excepted quantities (EQ) Code: E2
Maximum net quantity per inner packaging: 30 ml
Maximum net quantity per outer packaging: 500 ml
· Transport category: 2
· Tunnel restriction code: E
· IMDG
· Limited quantities (LQ) 1L
· Excepted quantities (EQ) Code: E2
Maximum net quantity per inner packaging: 30 ml
Maximum net quantity per outer packaging: 500 ml
· UN "Model Regulation": UN 1791 HYPOCHLORITE SOLUTION MIXTURE, 8, II,
ENVIRONMENTALLY HAZARDOUS
EU
(Contd. on page 8)

51.1.17
Page 8/9
Safety data sheet
Regulation (EC) No. 1907/2006 and 1272/2008
Printing date 21.01.2022 Version number 1 Revision: 20.01.2022

Trade name: Automatic Hematology Analyzer CC-5 Cell Clean A(CC-5)

(Contd. of page 7)

SECTION 15: Regulatory information


· 15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
· MAK(German Maximum Workplace Concentration)
None of the ingredients is listed.
· Directive 2012/18/EU
· Named dangerous substances - ANNEX I None of the ingredients is listed.
· Seveso category E1 Hazardous to the Aquatic Environment
· Qualifying quantity (tonnes) for the application of lower-tier requirements 200 t
· Qualifying quantity (tonnes) for the application of upper-tier requirements 500 t
· DIRECTIVE 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and
electronic equipment – Annex II
None of the ingredients is listed.
· National regulations:
· Waterhazard class: Water hazard class 2 (Self-assessment): hazardous for water.
· Other regulations, limitations and prohibitive regulations
· SVHC Candidate List of REACH Regulation Annex XIV Authorisation (8/7/2021)
None of the ingredients is listed
· REACH Regulation Annex XVII Restriction (25/1/2021)
See Section 16 for information about restriction of use.
None of the ingredients is listed
· REACH Regulation Annex XIV Authorisation List (6/2/2020)
None of the ingredients is listed

· 15.2 Chemical safety assessment: A Chemical Safety Assessment has not been carried out.

SECTION 16: Other information


· Relevant hazard statements
H314 Causes severe skin burns and eye damage.
H318 Causes serious eye damage.
H332 Harmful if inhaled.
H373 May cause damage to organs through prolonged or repeated exposure.
H400 Very toxic to aquatic life.
H410 Very toxic to aquatic life with long lasting effects.
· Classification according to Regulation (EC) No. 1272/2008
Skin corrosion/irritation The classification of the mixture is generally based
Serious eye damage/eye irritation on the calculation method using substance data
Hazardous to the aquatic environment - short-term according to Regulation (EC) No. 1272/2008.
(acute) aquatic hazard
Hazardous to the aquatic environment - long-term
(chronic) aquatic hazard
· ***************************************************************************************
The contents and format of this SDS are in accordance with Regulation (EC) No 1907/2006, 1272/2008 and
Regulation (EU) No 2015/830.

DISCLAIMER OF LIABILITY
The information in this SDS was obtained from sources which we believe are reliable. However, the
information is provided without any warranty, express or implied, regarding its correctness. The conditions
or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond
our knowledge. For this and other reason, we do not assume responsibility and expressly disclaim liability
for loss, damage or expense arising out of or in any way connected with the handling, storage, use or
(Contd. on page 9)
EU

51.1.17
Page 9/9
Safety data sheet
Regulation (EC) No. 1907/2006 and 1272/2008
Printing date 21.01.2022 Version number 1 Revision: 20.01.2022

Trade name: Automatic Hematology Analyzer CC-5 Cell Clean A(CC-5)

(Contd. of page 8)
disposal of the product. This SDS was prepared and is to be used only for this product. If the product is used
as a component in another product, this SDS information may not be applicable.
· Abbreviations and acronyms:
ADR: Accord européen sur le transport des marchandises dangereuses par Route (European Agreement concerning the International
Carriage of Dangerous Goods by Road)
IMDG: International Maritime Code for Dangerous Goods
IATA: International Air Transport Association
GHS: Globally Harmonised System of Classification and Labelling of Chemicals
EINECS: European Inventory of Existing Commercial Chemical Substances
ELINCS: European List of Notified Chemical Substances
CAS: Chemical Abstracts Service (division of the American Chemical Society)
DNEL: Derived No-Effect Level (REACH)
PNEC: Predicted No-Effect Concentration (REACH)
LC50: Lethal concentration, 50 percent
LD50: Lethal dose, 50 percent
PBT: Persistent, Bioaccumulative and Toxic
vPvB: very Persistent and very Bioaccumulative
Acute Tox. 4: Acute toxicity - inhalation – Category 4
Skin Corr. 1B: Skin corrosion/irritation – Category 1B
Eye Dam. 1: Serious eye damage/eye irritation – Category 1
STOT RE 2: Specific target organ toxicity (repeated exposure) – Category 2
Aquatic Acute 1: Hazardous to the aquatic environment - acute aquatic hazard – Category 1
Aquatic Chronic 1: Hazardous to the aquatic environment - long-term aquatic hazard – Category 1
· ***********************************************************************************
End of document