Models 705C-710C-715C AM Transmitters, 5000 to 15000 watts
GENERAL
FINAL CAVITY
Power Output:
Nominal: 5000W 10000W 15000W
Maximum: 6000W 12000W 15000W
Power Consumption:
Zero Modulation: 10600W 19000W 28000W
Average Modulation: 12000W 22000W 33000W
100% Modulation: 15500W 27000W 40000W
Carrier Shift:
0-100% modulation: Less than 2%, all models
Weight: 1900 lbs. (862 kg) 2150 lbs. (975 kg) 2300 lbs. (1043 kg)
20 00
LC FEMALE (705C)
1%" EIA (710C-715C) SOLID
STATE
AF
NFU, DRIVER
MODULE
FLOOR PLAN
FRONT OF CABINET Models 705C-710C
CJ •
••1;;O •••CI
• • •
0 0 0 0 0
•,; •• • —
.1
OPERATIONAL BENEFITS
o Solid State direct FM phase lock loop exciter. Fuses with fault indicator.
D AFC status indication. D Two (2) tube types.
DI Grounded grid power amplifier. D FCC primary circuits metered and continually
• No neutralization required. monitored.
• VSWR protections. D Secondary operational parameters with multimeter
13 Automatic power output control. readout.
o Remote ready -wire or STL. D Solid State timing -diode logic and relays.
D Interface for telemeter control equipment. DI Tally light fault indicator with memory system.
• ATS interface. Tuning controls with counter indicators.
• Three (3) phase optional single phase. D Unexcelled accessibility.
• Front panel circuit breaker.
11h_11111 11h_11111
ELCOM • BAUER 6199 WAREHOUSE WAY, SACRAMENTO, CA 95826, U.S.A. • (916) 381-3750
TELEX 377-331 • ANS. BK. "ELCOM BAUER SAC."
li e"9 11 li P'-gi ll
BROADCAST PRODUCTS
Models 603-605 FM Transmitters
GENERAL
690PLL EXCITER
The 690PLL Exciter is the heart of all transmitter
models. Its advanced phase-locked loop design pro-
vides great frequency stability while delivering an
exceptionally clean signal for further amplification. A
single crystal frequency is used to synthesize any
carrier frequency in the FM band; the frequency can be
programmed in 100 KHz steps.
690PLL EXCITER
METERING, CONTROL and PROTECTION CIRCUITS
All important operating parameters are metered, mentary fault occur. The tally light memory keeps the
including operating elapsed time and AC line voltage. appropriate fault indicator lamp lit until it is reset
A multimeter is provided to check seven operating locally or by remote control.
voltages and currents. The 690PLL Exciter has its own Interfacing to remote control or ATS systems is
multimeter as well as operating and AFC status simple with all of the standard functions accessible
indicators. via terminal strips. A four-function remote control
The final plate current, final input current, driver interface is available to simplify remote control installa-
plate current, and VSWR are overload protected and tion. All control circuits are accessible via a swing-out
monitored by a tally light system with memory. Auto- panel.
matic recycling restarts the transmitter should a mo-
10•51111 MIA
1P
o
-.-_-
0 CO :
1
1.1 v01 ,0.0.
[imam.] ('
• • •
AM Noise, referred to
equivalent 100%
AM modulation: Better than -50 dB, both models
FLOOR PLAN
79.00"
rl 17.00"
10 50 le-
0
65" 850"
603/605B
HARMONIC FILTER 700"
SQ PA AIR OUT
& DIRECTIONAL COUPLER
CABINET FAN
11 1
00"
11.50"
32.50" 29.50" 32.13"
OPERATIONAL BENEFITS
Solid State direct FM phase lock loop exciter. D Fuses with fault indicator.
AFC status indication. D Three (3) tube types.
Grounded grid power amplifier. • FCC primary circuits metered and continually
No neutralization required. monitored.
VSWR protection. D Secondary operating parameters with multimeter
Automatic power output control. readout.
Remote ready—wire or STL. D Solid State timing-diode logic and relays.
Interface for standard telemeter control equipment. D Tally light fault indicator with memory system.
ATS interface. D Tuning controls with counter indicators.
Built-in standby. • Unexcelled accessibility.
Front panel circuit breaker.
1111à-dill
ELCOM • BAUER 6199 WAREHOUSE WAY, SACRAMENTO, CA 95826, U.S.A. • (916) 381-3750
BROADCAST PRODUCTS
Models 610A-625A FM Transmitters, 7500-27500 watts
690PLL EXCITER
690PLL EXCITER
The 690PLL exciter is the heart of both transmitter
models. Its advanced phase-locked loop design pro-
vides great frequency stability while delivering an ex-
ceptionally clean signal for further amplification. A
single crystal frequency is used to synthesize any car-
rier frequency in the FM band; the frequency can be
programmed in 100 KHZ steps.
The 690PLL accepts input signals from monaural
programming, composite stereo generators, and SCA
generators. The applicable specifications for the 690PLL
are incorporated into the transmitter specifications
shown on the following pages. Also available from
Elcom-Bauer are companion model 682 stereo gener-
ator and model 683 SCA generator.
IRS e
o
,—•Are"
— .1111r.
-
l
p
METERING AND PROTECTIVE CONTROL SYSTEM
Output Impedance: 50 ohms nominal 50 ohms nominal Maximum Altitude:* 7500 feet (2286 meters), both models
FRONT VIEW
175r DC-201
DIRECTIONAL COUPLER
J203
(REVERSE)
741 J201 (FORWARD) 12 00"
J204 (FORWARD)
J203 (REVERSE)