Current Transducer HXS 20-NP IP N = 5, 10, 20 A

For the electronic measurement of currents: DC, AC, pulsed..., with


galvanic separation between the primary circuit and the secondary
DUAL PHASE
circuit.

All data are given with RL = 10 kΩ

Electrical data
Features
IP N Primary nominal RMS current ±20 A
IP M Primary current, measuring range ±60 A ● Hall effect measuring principle
SN Nominal sensitivity 0.625 V/ IP N ● Multirange current transducer
Uout Output voltage (Analog) @ IP UO E ±(0.625·IP/ IP N) V through PCB pattern lay-out
Uref Reference voltage 1) Output voltage 2.5 ±0.025 V ● Galvanic separation between
Output impedance typ. 200 Ω primary and secondary circuit
Load impedance 200 kΩ ● Insulation test voltage 3500 V
RL Load resistance 2 kΩ ● Extremely low profile < 11 mm
Rout Output internal resistance <5 Ω ● Fixed offset & sensitivity
CL Load capacitance (±20 %) 4.7 nF ● Low power consumption
UC Supply voltage (±5 %) 2) 5 V ● Single power supply +5 V
IC Current consumption @ UC = 5 V 19 mA ● Insulating plastic case recognized
according to UL 94-V0.
Accuracy - Dynamic performance data
Advantages
ε Error 3) @ IP N, TA = 25 °C ±1 %
εL Linearity error 0 ... IP N ±0.5 % ● Small size and space saving
0 ... 3 × IP N ±1 % ● Only one design for wide current
TCUO E Temperature of coefficient of UO E (+25 ... 105 °C) ±0.4 mV/K ratings range
(−40 ... +25 °C) ±0.525 mV/K ● High immunity to external
TCUref Temperature of coefficient of Uref (+25 ... 105 °C) ±0.01 %/K interference
(−40 ... +25 °C) ±0.015 %/K ● Uref IN/OUT.
TCUO E / UrefTemperature coefficient of UO E /Uref ±0.15 mV/K
Application
TCS Temperature of coefficient of S ±0.05% of reading/K
UO E Electrical offset voltage @ IP = 0, TA = 25 °C Uref ±0.0125 V ● AC variable speed drives and
UO M Magnetic offset voltage @ IP = 0 servo motor drives
after an overload of 3 × IPN ±0.7 % ● Static converters for DC motor
tD 10 Delay time to 10 % of the final output value for IP N step < 3 µs drives
tD 90 Delay time to 90 % of the final output value for IP N step 4) < 5 µs ● Battery supplied applications
Uno Output voltage noise (DC ... 10 kHz) < 20 mVpp ● Uninterruptible Power Supplies
(DC ... 1 MHz) < 40 mVpp (UPS)
BW Frequency bandwidth (−3 dB) 5) DC ... 50 kHz ● Switched Mode Power Supplies
Notes: 1) It is possible to overdrive Uref with an external reference voltage between (SMPS)
1.5 - 2.8 V providing its ability to sink or source approx. 5 mA ● Power supplies for welding
2)
Maximum supply voltage (not operating) < 6.5 V applications.
3)
Excluding offset and magnetic offset voltage Application domain
4)
For a di/dt = 50 A/µs
5)
Small signal only to avoid excessive heatings of the magnetic core. ● Industrial.

N°74.90.17.000.0 Page 1/3

9October2023/Version 23 LEM reserves the right to carry out modifications on its transducers, LEM International SA
in order to improve them. Route du Nant-d’Avril, 152
1217 Meyrin
www.lem.com
Current Transducer HXS 20-NP
General data
TA Ambient operating temperature 1) −40 ... +105 °C
TA st Ambient storage temperature −40 ... +105 °C
m Mass 10 g
Standards EN 50178:1997
Note: 1)
UL recognized with surrounding temperature until +85 °C.

Insulation coordination
Ud RMS voltage for AC insulation test, 50 Hz, 1 min 3.5 kV
Min
dCp Creepage distance 7.48 mm
dCI Clearance 6.6 mm
CTI Comparative tracking index (group I) > 600

Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:

● Over voltage category OV 3


● Pollution degree PD2
● Non-uniform field

According to UL 508 standards and following conditions: Maximum voltage 600 V

● Over voltage category OV 3


● Pollution degree PD2

EN 50178 IEC 61010-1


dCp , dCI Rated insulation voltage Nominal voltage
Basic insulation 600 V 600 V
Reinforced insulation 300 V 150 V

Safety
This transducer must be used in limited-energy secondary circuits according to
IEC 61010-1.

This transducer must be used in electric/electronic equipment with respect to


applicable standards and safety requirements in accordance with the manufacturer’s
operating instructions.

Caution, risk of electrical shock

When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury
and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation. A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3

9October2023/Version 23 LEM reserves the right to carry out modifications on its transducers, LEM International SA
in order to improve them. Route du Nant-d’Avril, 152
1217 Meyrin
www.lem.com
Dimensions HXS 20-NP (in mm)

dCl dCP

Connection

+ UC

Uout
Uref

Primary RMS current Primary


Primary Primary Recommended
insertion
connections nominal maximum resistance PCB connections
inductance
IP N [ A ] IP [ A ] RP [ mΩ ] LP [ µH ]
IN 1 3 5 7
1 20 60 0.05 0.025
2 4 6 8 OUT
IN 1 3 5 7
2 10 30 0.2 0.1
2 4 6 8 OUT
IN 1 3 5 7
4 5 15 1 0.4
2 4 6 8 OUT

Mechanical characteristics Remarks


● General tolerance ±0.2 mm ● Uout is positive when IP flows from terminals 1,3 ,5, 7 (IN) to
● Transducer fastening & terminals 2 , 4, 6, 8 (OUT).
connection of primary jumper 8 pins 1.2 × 1.2 mm ● Temperature of the primary conductor should not exceed
(corner R 0.4 mm) 120 °C.
● Transducer fastening & ● IInstallation of the transducer must be done, unless
connection of secondary pin 4 pins 0.5 × 0.25 mm otherwise specified on the datasheet, according to LEM
Transducer Generic Mounting Rules. Please refer to LEM
Recommended PCB hole document N°ANE120504 available on our Web site:
● Primary PCB hole ⌀ 1.5 mm https://www.lem.com/en/file/3137/download
● Secondary PCB hole ⌀ 0.7 mm
Page 3/3

9October2023/Version 23 LEM reserves the right to carry out modifications on its transducers, LEM International SA
in order to improve them. Route du Nant-d’Avril, 152
1217 Meyrin
www.lem.com