Specification: 50A Current Sensor
Specification: 50A Current Sensor
Specification: 50A Current Sensor
: T60404-N4647-X664
VACUUMSCHMELZE
1)Constructed and manufactured and tested in accordance with EN 61800-5-1:2003 (primary to secondary)
Reinforced insulation, Insulation material group 1, Pollution degree 2
The current sensor passed the EMI susceptibility tests (vertical and horizontal, one direction) according to
the standard 61000-4-3:2010 at 20V/m, 80%AM@1kHz over the frequency range of 80MHz to 1000MHz, level a)
with <2% variation of the Vout during the stress
24
0.5
+0 .5
Ø1.0 3.5 - 0 .3
1.84 2.14
7.62 1.905 0.46x0.46
12 2.54 5.72
Schematic diagram:
680 10 VC
int REF
7 V ref IN / OUT
Ip 40k
+ 10k
1...3 +
10
RM OUT 8 Vout
10k
-
1nF
40k
9 GND
4...6
Routine-Tests: (Measurement after temperature balance of the samples at room temperature, SC=significant characteristic)
VOUT (SC) (100%) M3011/6: Output voltage 625 ± 0.7% mV
VOUT-VREF (100%) M3226: Offset voltage ±0.725 mV
Ud (100%) M3014: Test voltage, 1s 1.5 kVRMS
UPDE 1.4
(AQL 1/S4) M3024: Partial discharge voltage (extinction) kVRMS
UPD*1.875 1.75
Other instructions:
- Current direction: A positive output voltage vs. VREF appears at point VOUT, if primary current flows in direction of
the arrow sign on Sensor package.
- Temperature of the primary conductor should not exceed 105°C.
- Housing and bobbin material UL-listed: Flammability class 94V-0.
- Further standards: UL 508 file E317483, category NMTR2 / NMTR8
- The color of the plastic material is not specified and the current sensor can be supplied in different colors
(e.g. brown, black, white, natural). This has no effect on the specifications or UL approval