Current Transducer LF 505-S IPN = 500 A

For the electronic measurement of currents: DC, AC, pulsed...,


with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).

16137
Electrical data

IPN Primary nominal current rms 500 A Features


IPM Primary current, measuring range 0 .. ± 800 A
RM Measuring resistance R M mini R M maxi • Closed loop (compensated) current
with ± 15 V @ ± 500 A maxi 0 60 Ω transducer using the Hall effect
@ ± 800 A maxi 0 11 Ω • Isolated plastic case recognized
with ± 18 V @ ± 500 A maxi 0 92 Ω according to UL 94-V0.
@ ± 800 A maxi 0 30 Ω
with ± 24 V @ ± 500 A maxi 5 149 Ω Advantages
@ ± 800 A maxi 5 65 Ω
• Excellent accuracy
ISN Secondary nominal current rms 100 mA • Very good linearity
KN Conversion ratio 1 : 5000 • Low temperature drift
VC Supply voltage (± 5 %) ± 15 .. 24 V • Optimized response time
IC Current consumption (± 1 mA) 24 (@ ± 18 V) + IS mA • Wide frequency bandwidth
• No insertion losses
Accuracy - Dynamic performance data • High immunity to external
interference
X Accuracy @ IPN , TA = 25°C ± 0.6 % • Current overload capability.
ε L
Linearity error < 0.1 %
Applications
Typ Maxi
IO Offset current @ IP = 0, TA = 25°C ± 0.4 mA • AC variable speed drives and servo
IOM Magnetic offset current @ IP = 0 and specified RM, motor drives
after an overload of 3 x IPN ± 0.2 mA • Static converters for DC motor drives
IOT Temperature variation of IO - 40°C .. + 70°C ± 0.1 ± 0.4 mA • Battery supplied applications
tr 1)
Response time to 90 % of IPN step <1 µs • Uninterruptible Power Supplies (UPS)
di/dt di/dt accurately followed > 100 A/µ s • Switched Mode Power Supplies
BW Frequency bandwidth (- 1 dB) DC .. 100 kHz (SMPS)
• Power supplies for welding
applications.
General data
Applications domain
TA Ambient operating temperature - 40 .. + 70 °C
TS Ambient storage temperature - 40 .. + 85 °C
• Traction
RS Secondary coil resistance @ TA = 70°C 70 Ω
• Industrial.
m Mass 230 g
Standards EN 50155: 1995
EN 50178: 1997
1)
Note: With a di/dt of 100 A/µs.

page 1/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
071003/10 w w w .lem.com
Current Transducer LF 505-S

Isolation characteristics

Vd Rms voltage for AC isolation test, 50 Hz, 1 min 3.8 kV


Vw Impulse withstand voltage 1.2/50 µs 12.5 kV
Mini
dCp Creepage distance 15.2 mm
dCl Clearance distance 14.5 mm
CTI Comparative Tracking Index (Group IIIa) 175

Application examples

According to EN 50178 and CEI 61010-1 standards and following conditions:

• Over voltage category OV 3


• Pollution degree PD2
• Non-uniform field

EN 50178 CEI 61010-1


dCp, dCI, V W Rated isolation voltage Nominal voltage

Single isolation 1250 V 1250 V rms


Reinforced isolation 690 V 690 V rms

Safety

This transducer must be used in electric/electronic equipment with respect to


applicable standards and safety requirements in accordance with the manufacturer's
operating instructions.

Caution, risk of electrical shock

When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.

page 2/3

071003/10 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com
Dimensions LF 505-S (in mm. 1 mm = 0.0394 inch)

Bottom view

Right view Back view

Top view
Connection

Mechanical characteristics Remarks


• General tolerance ± 0.5 mm • IS is positive when IP flows in the direction of the arrow.
• Transducer fastening • Temperature of the primary conductor should not exceed
Vertical or flat lying position 4 or 6 holes ∅ 4.3 mm 100°C.
4 or 6 steel screws M4 • Dynamic performances (di/dt and response time) are best
Recommended fastening torque 3.2 Nm or 2.37 Lb.-Ft. with a single bar completely filling the primary hole.
or vertical position 4 holes ∅ 1.9 mm, • This is a standard model. For different versions (supply
depth : 7.5 mm voltages, turns ratios, unidirectional measurements...), please
4 screws PTKA 25, contact us.
length: 6 mm
Recommended fastening torque 0.7 Nm or 0.52 Lb.-Ft.
or flat lying position 4 holes ∅ 1.9 mm, crossing
4 screws PTKA 25,
length:10 mm
Recommended fastening torque 0.75 Nm or 0.55 Lb.-Ft.
• Primary through-hole ∅ 30.2 mm
• Connection of secondary MOLEX 6410
3 Tin plated pins page 3/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
071003/10 w w w .lem.com