Current Transducer LF 505-S/SP27 IPN = 500 A

For the electronic measurement of currents: DC, AC, pulsed...,


with galvanic separation between the primary circuit and the secondary
circuit. d d Cl Cp

Features
Electrical data
●● Closed loop (compensated)
IPN Primary nominal rms current 500 A current transducer using the Hall
IPM Primary current, measuring range 0 … ±1480 A effect
RM Measuring resistance RM min RM max ●● Insulating plastic case recognized
with ±24 V @ ±500 A max 0 148.5 Ω according to UL 94-V0.
@ ±1480 A max 0 2.5 Ω
ISN Secondary nominal rms current 100 mA Special features
KN Conversion ratio 1 : 5000
●● IPM = 0 … ±1480 A
UC Supply voltage (±5 %) ±24 V
●● UC = ±24 V (±5 %)
IC Current consumption IP 33 + IS mA
UC ●● Connection to secondary circuit
IS
RM
on JST BH03B-XASK-BN
Accuracy - Dynamic performance data
connector
UC
X Accuracy @ IPN, TA = 25 °C ±0.6 % ●● 2D Datamatrix Barcode-label
@ IPN, TA = −10 °C … +70 °C ±0.9 % ●● Improved dynamic performance
εL Linearity error < 0.1 % ●● Extended temperature range.
Typ Max
Advantages
IO Offset current @ IP = 0, TA = 25 °C ±0.4 mA
IOM Magnetic offset current @ IP = 0, and specified RM, ●● Excellent accuracy
after an overload of 3 × IPN ±0.2 mA ●● Very good linearity
IOT Temperature variation of IO −10 °C … +70 °C ±0.1 ±0.3 mA ●● Low temperature drift
−40 °C … −10 °C ±0.3 ±0.8 mA ●● Optimized response time
tr Step response time 1) to 90 % of IPN < 1 µs ●● Wide frequency bandwidth
di/dt di/dt accurately followed > 200 A/µs ●● No insertion losses
BW Frequency bandwidth (−1 dB) DC … 100 kHz ●● High immunity to external
interference
General data ●● Current overload capability.
TA Ambient operating temperature −40 … +70 °C Applications
TS Ambient storage temperature −40 … +85 °C
RS Resistance of secondary winding @ TA = 70 °C 68 Ω ●● AC variable speed drives and
m Mass 230 g servo motor drives
Standards EN 50178: 1997 ●● Static converters for DC motor
IEC 61800-5-1 drives
UL 508: 200 ●● Battery supplied applications
●● Uninterruptible Power Supplies
Note: 1)
With a di/dt of 100 A/µs. (UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.

Application domain

N° 97.14.50.027.0 ●● Industrial.
Page 1/3

9December2015/version 8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
Current Transducer LF 505-S/SP27
Insulation coordination
Ud Rms voltage for AC insulation test, 50 Hz, 1 min 3.8 kV
ÛW Impulse withstand voltage 1.2/50 µs 17.3 kV
Min
dCp Creepage distance 1) 39 mm
dCI Clearance 1) 23 mm
CTI Comparative tracking index (group IIIa) 175

Note: 1)
Without cable length.

Applications examples

According to EN 50178 and IEC 61010-1 standards and following conditions:

●● Over voltage category OV 3


●● Pollution degree PD2
●● Non-uniform field

EN 50178 IEC 61010-1


dCp, dCI, ÛW Rated insulation voltage Nominal voltage
Basic insulation 3000 V 3200 V
Reinforced insulation 1500 V 1600 V

Safety

This transducer must be used in limited-energy secondary circuits according to


IEC 61010-1.

This transducer must be used in electric/electronic equipment with respect to


applicable standards and safety requirements in accordance with the manufacturer’s
operating instructions.

Caution, risk of electrical shock

When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.

N° 97.14.50.027.0 Page 2/3

9December2015/version 8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
Dimensions LF 505-S/SP27 (in mm)

dCl dCp

Connection

IP
UC
IS
RM

UC

Mechanical characteristics Remarks


●● General tolerance ±0.5 mm ●● IS is positive when IP flows in the direction of the arrow.
●● Transducer fastening ●● Temperature of the primary conductor should not exceed
4 or 6 holes ⌀ 4.3 mm
Vertical or horizontal position 100 °C.
4 or 6 M4 steel screws
●● Installation of the transducer must be done unless
Recommended fastening torque 3.2 N·m
otherwise specified on the datasheet, according to LEM
or vertical position 4 holes ⌀ 1.9 mm
depth: 6 mm Transducer Generic Mounting Rules. Please refer to
4 screws PTKA 25 LEM document N°ANE120504 available on our Web site:
length: 6 mm Products/Product Documentation.
Recommended fastening torque 0.7 N·m ●● Dynamic performances (di/dt and response time) are
or horizontal position 4 holes ⌀ 1.9 mm, crossing best with a single bar completely filling the primary hole.
4 screws PTKA 25
length: 10 mm
Recommended fastening torque 0.75 N·m
●● Primary through-hole 30 × 10 mm
or ⌀ 30.2 mm max
●● Connection of secondary JST BH03B-XASK-BN

N° 97.14.50.027.0 Page 3/3

9December2015/version 8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com