Current Transducer LF 205-S/SP3 100 A
Current Transducer LF 205-S/SP3 100 A
Current Transducer LF 205-S/SP3 100 A
Features
Electrical data
● Closed loop (compensated)
IP N Primary nominal RMS current 100 A current transducer using the Hall
IP M Primary current, measuring range 0 ... ±200 A effect
RM Measuring resistance @ TA = 70 °C TA = 85 °C ● Insulating plastic case recognized
RM min RM max RM min RM max according to UL 94-V0.
with ±12 V @ ±100 A max 0 95 15 94 Ω
@ ±200 A max 0 40 15 39 Ω Special features
with ±15 V @ ±100 A max 16 123 47 122 Ω
● IP N = 100 A
@ ±200 A max 16 55 47 54 Ω
● IP M = 0 ... ±200 A
IS N Secondary nominal RMS current 100 mA
● NP/NS = 1 : 1000.
NP/NS Turns ratio 1 : 1000
UC Supply voltage (+5 %) ±12 ... 15 V Advantages
IC Current consumption @ ±15 V 17 + IS mA
● Excellent accuracy
Accuracy - Dynamic performance data ● Very good linearity
● Low temperature drift
εtot Total error @ IP N, TA = 25 °C ±0.5 % ● Optimized response time
εL Linearity error < 0.1 % ● Wide frequency bandwidth
Typ Max ● No insertion losses
IO E Electrical offset current @ IP = 0, TA = 25 °C ±0.2 mA ● High immunity to external
IO M Magnetic offset current 1) @ IP = 0 and specified RM, interference
after an overload of 3 × IP N ±0.1 mA ● Current overload capability.
IO T Temperature variation of IO −40 °C ... +85 °C ±0.25 ±0.65 mA
Applications
tD 10 Delay time to 10 % of the final output value for IP N step < 500 ns
tD 90 Delay time 2) to 90 % of the final output value for IP N step < 1 µs ● AC variable speed drives and
BW Frequency bandwidth (−3 dB) DC ... 100 kHz servo motor drives
● Static converters for DC motor
General data drives
● Battery supplied applications
TA Ambient operating temperature −40 ... +85 °C
● Uninterruptible Power Supplies
TA st Ambient storage temperature −40 ... +90 °C
(UPS)
RS Resistance of secondary winding @ TA = 70 °C 10 Ω
● Switched Mode Power Supplies
@ TA = 85 °C 11 Ω
(SMPS)
m Mass 78 g
● Power supplies for welding
Standards EN 50178: 1997
applications.
Application domain
Notes: 1) The result of the coercive force of the magnetic circuit
2)
For a di/dt = 100 A/µs. ● Industrial.
7July2023/Version 13 LEM reserves the right to carry out modifications on its transducers, LEM International SA
in order to improve them. Route du Nant-d’Avril, 152
1217 Meyrin
www.lem.com
Current Transducer LF 205-S/SP3
Insulation coordination
Ud RMS voltage for AC insulation test, 50/60 Hz, 1 min 3.5 kV
UNi Impulse withstand voltage 1.2/50 µs 8.8 kV
Ut Partial discharge RMS test voltage (qm< 10 pC) > 2 kV
Min
dCp Creepage distance 11 mm
dCI Clearance 10.2 mm
CTI Comparative Tracking Index (group IIIa) 175
Applications examples
Safety
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
7July2023/Version 13 LEM reserves the right to carry out modifications on its transducers, LEM International SA
in order to improve them. Route du Nant-d’Avril, 152
1217 Meyrin
www.lem.com
Dimensions LF 205-S/SP3 (in mm)
dCl dCp
Connection
IS RM
IP
UC
UC
Page 3/3