Current Transducer LAH 50-P/SP1 IPN = 50 A

For the electronic measurement of currents: DC, AC, pulsed ...,


with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).

16004
Electrical data
IPN Primary nominal current rms 50 A Features
1)
IPM Primary current, measuring range 0 .. ± 90 A • Closed loop (compensated) current
RM Measuring resistance @ TA = 70°C TA = 85°C transducer using the Hall effect
RM min RM max RM min RM max • Printed circuit board mounting
with ± 15 V @ IPN [± A DC ] 22 163 58 159 Ω • Insulated plastic case recognized
@ IPN [A RMS ] 2) 22 93 58 89 Ω according to UL 94-V0.
@ IP IPN 2)
ISN Secondary nominal current rms 50 mA Special features
KN Conversion ratio 1 : 1000 • IPM = 0 .. ± 90 A
VC Supply voltage (± 5 %) ± 15 V • K N= 1 : 1000.
IC Current consumption 10 + IS mA
Advantages
Accuracy - Dynamic performance data • Excellent accuracy
X Accuracy 3) @ IPN, TA = 25°C ± 0.25 % • Very good linearity
ε L
Linearity error < 0.15 % • Low temperature drift
Typ Max • Optimized response time
IO Offset current @ TA = 25°C ± 0.3 mA • Wide frequency bandwidth
IOM Magnetic offset current @ IP = 0 and specified RM, • No insertion losses
after an overload of 5 x IPN ± 0.2 ± 0.3 mA • High immunity to external
IOT Temperature variation of IO 0°C .. + 70°C ± 0.2 ± 0.6 mA interference
- 25°C .. + 85°C ± 0.2 ± 0.8 mA • Current overload capability.
tr a Reaction time @ 10 % of IPN < 200 ns Applications
tr Response time 4) to 90 % of IPN step < 500 ns
di/dt di/dt accurately followed > 200 A/µs • AC variable speed drives and servo
BW Frequency bandwidth (- 1 dB) DC .. 200 kHz motor drives
• Static converters for DC motor drives
• Battery supplied applications
General data
• Uninterruptible Power Supplies
TA Ambient operating temperature - 25 .. + 85 °C (UPS)
TS Ambient storage temperature - 40 .. + 90 °C • Switched Mode Power Supplies
RS Secondary coil resistance @ TA = 70°C 72 Ω (SMPS)
@ TA = 85°C 76 Ω • Power supplies for welding
m Mass 22 g applications.
Standards EN 50178: 1997
Application domain
• Industrial.
Notes: 1)
During 10 s, with R M ≤ 53 Ω
2)
The measuring resistance RM min may be lower
(see "LAH Technical Information" leaflet or the "LAH Application Note")
3)
Without IO & IO M
4)
With a di/dt of 100 A/µs.
Page 1/3

071113/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com
Current Transducer LAH 50-P/SP1

Isolation characteristics

Vd Rms voltage for AC isolation test, 50/60 Hz, 1 mn 5 kV


Vw Impulse withstand voltage 1.2/50 µs 12 kV
Ve Partial discharge extinction voltage rms @ 10pC >2 kV
Min
dCp Creepage distance 5) 11.75 mm
dCl Clearance distance 5) 11.75 mm
CTI Comparative Tracking Index (Group III a) 175

Application examples

According to EN 50178 and IEC 61010-1 standards and following conditions:

• Over voltage category OV 3


• Pollution degree PD2
• Non-uniform field

EN 50178 IEC 61010-1


dCp, dCI Rated isolation voltage Nominal voltage

Single isolation 1000 V 1000 V

Reinforced isolation 500 V 500 V

Note: 5)
On PCB with soldering pattern UTEC93-703.

Safety

This transducer must be used in electric/electronic equipment with respect to


applicable standards and safety requirements in accordance with the manufacturer's
operating instructions.

Caution, risk of electrical shock

When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.

Page 2/3

071113/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com
Dimensions LAH 50-P/SP1 (in mm. 1 mm = 0.0394 inch)

Connection

Bottom view

Left view

Front view

Number Primary current N o m i n a l Turns Primary Primary insertion


of primary nominal maximum output current r a t i o resistance i n d u c t a n c e
t u r n s IPN [ A ] IP [ A ] ISN [ mA ] KN RP [ mΩ ] LP [ µH ]

1 50 90 50 1 : 1000 0.12 0.008

Mechanical characteristics Remarks


• General tolerance ± 0.2 mm • IS is positive when IP flows from IN to OUT.
• Fastening & connection of primary 6 pins 1.4 x 1 mm • The jumper temperature and PCB should not exceed 100°C.
Recommended PCB hole 2 mm
• Fastening & connection of secondary 3 pins 0.7 x 0.6 mm
Recommended PCB hole 1.2 mm

Page 3/3