(4317) ROYAL VILLA 53_4
(4317) ROYAL VILLA 53_4
(4317) ROYAL VILLA 53_4
2'-0"
WOODGRAIN FINISH CLADDING
-AS SHOWN
26'-0 5/8" [7.94 M]
9'-1"
8'-0"
-AS SHOWN
8'-9"
-AS SHOWN
2'-0"
MANUFACTURED STONE
9'-1"
9'-1"
8'-0"
TYP. COLUMN DETAIL
T/O MAIN FLOOR
3'-1 1/2" [0.95 M]
T/O BASEMENT
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
ROOF VENTS
12 12
5 5
T/O SECOND FLOOR CEILING
T/O WINDOW
2'-0"
9'-1"
8'-0"
12 12
T/O SECOND FLOOR 4 4
T/O MAIN CEILING
1'-1"
T/O WINDOW
VINYL SIDING C/W
VINYL CORNERS
VINYL SIDING -AS SHOWN
c/w VINYL CORNERS
-AS SHOWN BOARD & BATTENS
9'-1"
-AS SHOWN
8'-0"
RAILING
3'-0" (MIN.) HAND RAIL FLAT PANEL
4" MAX. VERTICAL SPACING -AS SHOWN
DROPPED DECK
24" MAX. PARGING NOT HIGHER THAN
PROVIDE NAILING STRIPS 2' ABOVE FINISHED
WINDOW WELL IN FOUNDATION WALL GRADE
AS REQUIRED FOR DROPPED SIDING AS
REQUIRED
T/O BASEMENT
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
12 12 12
5 5 5
T/O SECOND
WOODGRAIN FLOOR CEILING
FINISH CLADDING
-AS SHOWN
2'-0"
T/O WINDOW
VINYL SIDING C/W
VINYL CORNERS
-AS SHOWN
9'-1"
BOARD &
6'-8"
BATTENS
-AS SHOWN
12 12 T/O SECOND
FLAT PANEL 12 12
4 4
-AS SHOWN 4 4 FLOOR
MANUFACTURED
12 T/O MAIN
STONE
4 CEILING
-AS SHOWN
T/O WINDOW
9'-1"
9'-1"
6'-8"
DROPPED DECK
10'-0"
NOT HIGHER THAN
2' ABOVE FINISHED
GRADE T/O MAIN
4"
FLOOR
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
ROOF VENTS 12
ROOF VENT SHOULD BE 4'-0" FROM 5
TRUSS BOTTOM CHORD
12
5
12 12 12
5 5 5
T/O SECOND FLOOR CEILING
WOODGRAIN
FINISH CLADDING T/O WINDOW
2'-0" -AS SHOWN
9'-1"
VINYL CORNERS
-AS SHOWN
6'-8"
BOARD &
BATTENS
12 -AS SHOWN
4 T/O SECOND FLOOR
MANUFACTURED
T/O MAIN CEILING
STONE
12 12 -AS SHOWN
2'-0"
4 4
T/O WINDOW
9'-1"
6'-8"
45 MIN FIRE RATED DROPPED DECK
NOT HIGHER THAN
(FULL WALL) T/O MAIN FLOOR
2' ABOVE FINISHED
GRADE
1'-10"
T/O MAIN
FLOOR
T/O STAIR LANDING
2'-0"
24" MAX. PARGING
PROVIDE NAILING STRIPS
WINDOW WELL
IN FOUNDATION WALL
AS REQUIRED
FOR DROPPED SIDING AS
REQUIRED
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
4'-6" [1.4 M]
2'-6" [0.8 M]
F
25'-8" [7.8 M]
RIGHT O
9'-6" [2.9 M]
8" [0.2 M]
21'-8" [6.6 M]
3.0m
W A Y
1'-6" [0.5 M] 30'-1 5/8" [9.2 M]
14'-6" [4.4 M]
N
8'-0" [2.4 M] GARAGE
30'-6" [9.3 M]
[16.0 M]
18'-0" [5.5 M]
HOUSE
52'-7 5/8"
4'-0" [1.2 M]
7'-10" [2.4 M]
DROPPED DECK
18'-0" [5.5 M]
M]
NOT HIGHER THAN
2' ABOVE FINISHED
8.6
GRADE
"[
3/8
DROPPED
'-2
5'-0" [1.5 M]
DECK
28
23'-0" [7.0 M]
5'-8" [1.7 M]
5'-0" [1.5 M]
ENTRY
10'-5 1
1'-6" [0.5 M]
19'-9" [6.0 M] 8'-0" [2.4 M] 49'-0" [14.9 M]
/8" [3.2
CL 5'-0" [1.5 M]
6'-0" [1.8 M]
8'-5 3/4
M
1'-6" [0.5 M]
9'-6 1/4
]
14'-3 3/4" [4.4 M]
M]
/8" [11.8
" [2.6 M
38'-7 1
" [2.9 M
]
]
10"
3'-11" 3'-2" 3" 12'-8" 9'-0"
TO
N
SL RD
32" DOOR
AI
AB
W
TO BE AIRTIGHT
4'-6"
R
O SD
A
SL
D
PE R
S
PE
D
2'-6"
SL AIN
AR
FLOOR O
AB
SL
W
RADON
DRAIN
TO
PUMP
4'-8"
4'-8"
SUMP 60"X32"
9'-6"
8'-4"
3'-6" 4" 3'-6"
8'-4"
SLIDER
4'-2"
SL OW
WINDOW HEIGHT AB
O AR
T
SL
PE D
AI
2" 1'-8"
8'-0" AFF PE
SL S D
D
O 4" THICK CONCRETE SLAB ON
AB R
DROPPED ENGINEERED BEAM
SL
S
13'-6"
D
WINDOW HEIGHT
AR
-SLOPE 2" TOWARD DRAIN
W
15'-0"
AI
TO
10"4"
N
SUPPLIED BY SUPPLIER
11'-0"
8'-0" AFF
11 7/8" I-JOIST
10'-0"
14'-6"
@ 19.2" o.c.
27'-6"
SL OW
3"
N
O AR
T
4" THICK CONCRETE SLAB ON
AI
D LAB
R
COMPACTED GRANULAR FILL
D
UNDER SLAB (MIN 100MM AND LESS THAN 10%
SL S D
AR S
S
GRANULAR FILL (RADON ROCKS) REQUIRED
1'-6"
W PE
-SLOPE 2" TOWARD DRAIN
AB R
3" 7'-9"
32'-6"
TO LO
16R
UP
S
OF MATERIAL THROUGH A 4MM SIEVE)
A
30'-6"
FLOOR
IN
DRAIN
16'-4"
18'-0"
8'-9"
SMOKE
ALARM/CO
SL
TO
O
N
W
PE
AI
AR
D LAB
R
SL
8'-6"
D
D
18'-0"
AR S
S
AB
S
FINAL LOCATION OF
W PE
D
17'-0"
17'-0"
2x10#2SPF@16"O.C. R
DROPPED ENGINEERED BEAM
MECHANICAL
TO LO
AI
N
S
EQUIPMENT
HRV
TO BE DETERMINED
PLUMBING
SUPPLIED BY SUPPLIER
ROUGH-IN
ON SITE 5'-0"
BUCK DOWN FOR
3-2"X10" #1 SPR. BM.
32" DOOR
10"
UTILITY
8'-9"
FURN
FLOOR W/H
DRAIN
5'-0"
WINDOW HEIGHT PRECAST
8'-0" AFF CONCRETE
SLIDER ELEC. PAN. LANDING/STEPS
6"X6" POST
3"
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
-9'-1" WALLS
-TOP OF WINDOWS @ 96" A.F.F. (UNLESS NOTED)
-ALL CABINETS TO BE DESIGNED & CONFIRMED WITH
SUPPLIER
-ALL ANGLED WALLS ARE AT 45° (UNLESS NOTED)
-BEDROOM SMOKE DETECTORS TO BE INSTALLED WITHIN 1
METER OF DOORWAY
-CENTRE OF TOILET DRAIN TO BE 1'-2" FROM BACK WALL &
72'-0"
1'-4" FROM SIDE WALL / VANITY AS REQUIRED
47'-4" 24'-8"
25'-8" 21'-8" 23'-2" 1'-6"
17'-2" 7'-4" 1'-2" 12'-10" 5'-0" 3'-10"
1'-0"
ENGINEERED BEAM SIZED BY SUPPLIER
4'-2" 2'-8" 6"
4'-6"
NOTE: ENGINEERED BEAM SIZED BY SUPPLIER
2'-6"
32"X80"
ELECTRIC FIREPLACE 5'-1" 7'-9"
4'-8"
4'-8"
36"X36" VAPOUR BARRIER APPLIED &
9'-6"
MINIMUM 12.7mm DRYWALL TO
8'-0"
3'-6" 4" 3'-6" SLIDER MEET N.B.C.-A.E.9.35.4.1 & 9.35.4.4
CUSTOM
CUSTOM CLOSET
8'-0"
SLIDER
TUB/SHOWER
5'-6"
22'-0" X 9'-6"
1'-8" 1'-8"
DN
CUSTOM CLOSET
13'-0"
MUDROOM
GREAT ROOM
19'-0"
9'-10" X 3'-6"
DEN
15'-3"
10'-4"
1'-0"6"
H.R.V.
14'-6"
RAILING
16'-4" X 14'-6"
11'-6"
11'-10" X 10'-8"
15'-0"
8'-4"
28"X80" BATH
11 7/8" I-JOIST
5'-0" X 9'-6" 11 7/8" I-JOIST
O
@ 19.2" o.c.
PE
@ 19.2" o.c.
5'-4"
N
6'-0"
TO
28"X80"
27'-6"
7'-3"
32"X80"
32"X80"
16R
UP
VE
SMOKE
1'-2"
ALARM 2-CAR GARAGE
8"
32'-6"
23'-6" X 17'-0"
4'-2"
ENG. APP. LAM.
BEAM (FLUSH)
30'-6"
SMOKE FLOOR
4'-0"
ENG. APP. LAM. BEAM (FLUSH)
20'-11" 8'-8" 18'-5" 18'-3" 5'-9"
16'-0"
18'-0"
11'-4" 6'-0" 3'-6" 2'-2" 6'-10" 14'-2"
4'-9"
4'-0" 24'-0"
3'-2"
RAILING
5'-4"
O
12" FLUSH EATING BAR
6'-6"
8'-6"
DN
4R
18'-0"
PE
NOT HIGHER THAN
N
SPICE KITCHEN
16'-6"
5'-0"
TO
DINING
15'-6"
6'-0" X 11'-8"
15'-3"
PATIO DOOR
6'-0"
AB
10'-0" X 15'-0"
DW
O
LINE OF FLOOR ABOVE
VE
12'-6"
DROPPED DECK DOOR SILL HEIGHT
RANGE
1'-0"
8'-0" X 18'-0'' 4" AFF
KITCHEN 32"X96" LIVING ROOM
6"
3'-6"
13'-10"
32"X80"
12'-6" X 12'-0" 13'-8" X 12'-0"
FOYER 2'-8" 6'-6"
3-2X10 #1 SPR
2X6 PLUMBING 5'-0" X 4'-6"
6'-0"
BEAM
WALL
3'-6"
42"X96"
COOKTOP
5'-0"
DN DN
4'-6"
WALL OVEN 4R 1R
3'-0"
3'-0"
2'-8"
1'-0"
VS SLIDER BEAM (FLUSH)
1'-6"
1'-6"
CUSTOM CLOSET
2'-1" 4'-9" 6'-10" 3'-4" SPR BEAM
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
2'-6"
2'-6"
2'-0"
ROD & SHELF
H.R.V.
60"X36"
4'-8"
36"X30" 36"X36"
SHOWER
TUB/SHOWER
5'-6"
60"X36"
5'-0"
12" RAISED CEILING
SLIDER CASEMENT
CUSTOM CLOSET
8'-0"
11'-8"
96"X72"
FIXED
GLASS ON
H.R.V.
5'-6"
5'-6"
HALF WALL
11'-10"
RAILING
3'-1"
BATH W.I.C
FREE-STANDING TUB
15'-0"
15'-0"
SLIDER
O
16R
PE
6'-0" X 10'-10"
DN
8'-4" X 10'-10"
N
48"X40"
12'-4"
6'-4"
TO
28"X80"
LO
60"X36"
3'-3"
28"X80"
28"X80"
28"X80"
W
5'-0"
6'-10"
7'-0"
2'-4" 2'-10"
25'-6"
2'-0"
56"X80"
2'-4"
SMOKE
30"X80"
FIXED
36"X60"
ALARM/CO
5'-6"
2'-0"
2'-0"
SMOKE
12" RAISED CEILING
30'-6"
RAILING
7'-0"
3'-0"
1'-6"
3'-10"
ALARM
3'-8"
3'-8"
4'-2"
12'-10" 5'-8" 14'-6" 10'-6" 8'-4" 14'-8"
32"X80"
ALARM
SMOKE
13'-10"
2'-0"
RAILING MASTER BEDROOM
3'-11"
8'-0"
60"X60"
SLIDER
SMOKE 13'-10" X 13'-4"
30"X80"
2'-0"
ALARM LAUNDRY 2'-0"
8'-0" X 5'-8"
72"X60"
SLIDER
5'-4"
8'-4"
J&J BATH 12" RAISED CEILING
F.D.
5'-8" X 11'-0"
6'-6"
15'-6"
BEDROOM 4
4'-5"
28"X80" 28"X80" D W
O
12'-0" X 13'-2"
PE
1'-6"
2'-0"
11'-10"
11'-10"
2'-0" 2'-0" OPEN SHELVES
N
28"X80"
ABOVE
TO
2X4
BEDROOM 3
H.R.V.
BE
CUSTOM CLOSET
LO
12'-4" X 11'-0"
5'-6"
2'-3"
W
7'-6"
6'-6"
5'-6"
FIXED
8'' SEATING
42"X60"
5'-0"
5'-0"
5'-0"
60"X36"
2'-0"
2'-9"
TUB/SHOWER
48"X48"
SLIDER
8'-0" 6'-6"
12'-10" 5'-8" 14'-6" 16'-0" LINE OF FLOOR BELOW 17'-6" 1'-0"1'-0"
49'-0" 19'-6"
68'-6"
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
2'-0"
4/12 SLOPE
2'-0"
2'-0"
4/12 SLOPE
2'-0" 2'-0"
2'-0"
5/12 SLOPE
2'-0"
5/12 SLOPE
5/12 SLOPE
5/12 SLOPE
2'-0"
2'-0"
5/12 SLOPE
2'-0"
5/12 SLOPE
2'-0"
4/12 SLOPE
5/12 SLOPE 2'-0"
2'-0"
5/12 SLOPE
2'-0"
2'-0"
5/12 SLOPE
5/12 SLOPE
4/12 SLOPE
2'-0"
2'-0" 4/12 SLOPE
4/12 SLOPE
2'-0"
4/12 SLOPE
2'-0"
2'-0"
2'-0" 2'-0"
2'-0"
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
12
4
FLUSH ENG. BEAM FLUSH ENG. BEAM
ENGINEERED FLOOR JOISTS SIZED BY SUPPLIER
SIZED BY SUPPLIER SIZED BY SUPPLIER
12
4
ENGINEERED BEAM
1'-4"
SIZED BY SUPPLIER
9'-1"
9'-1"
1"
7'-112
DROPPED DECK
9'-0"
NOT HIGHER THAN
2' ABOVE FINISHED
1'-7 3/4" [0.50 M]
GRADE
1'-10"
1"
ENGINEERED
3'-52
ENGINEERED
8"
8"
2'-47
2'-47
BEAM SIZED BY BEAM SIZED BY
1'-0"
SUPPLIER SUPPLIER
FLOOR DRAIN
9'-0"
MIN.
4'-0"
8"
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
GENERAL NOTES:
1'-0"
-SEE ENGINEER'S LAYOUT
-DESIGN IS BASED ON AN ENGINEERED ROOF TRUSS SYSTEM 12" RAISED CEILING
-SEE ENGINEER'S LAYOUT
-ALL BEAMS TO BE DESIGNED BY SUPPLIER
-SEE ENGINEER'S LAYOUT
-PRECAST CONCRETE STEPS OR CAST-IN-PLACE AS PER
PLAN UNLESS OTHERWISE SHOWN
-ENTRANCE DOORS TO BE SOLID CORE IN ACCORDANCE
WITH N.B.C. 2023-A.E. BUILDING CODE 9.7.2.1.
9'-1"
-INTERIOR DOOR FRAMING HEIGHT TO BE 83" FOR 80" DOOR,
99" FOR 96" DOOR
-PROVIDE SELF-CLOSER ON GARAGE-HOUSE DOOR, c/w
WEATHERSTRIPPING
-ALL WINDOWS SUBJECT TO LOCAL BYLAWS AND MUST MEET
CODE FOR EGRESS IN REQUIRED ROOMS
-WINDOW SIZES SHOWN ARE APPROXIMATE AND SHOULD BE
12
VERIFIED WITH THE BUILDER / CONTRACTOR / OWNER PRIOR
TO ORDERING / INSTALLATION - INCLUDING ROUGH 4
OPENINGS / STYLE / TYPE / GRILLES
-ALL WINDOWS 8'-0" AND OVER TO HAVE LINTEL SIZED BY ENGINEERED FLOOR JOISTS SIZED BY SUPPLIER
SUPPLIER 12 FLUSH ENG. BEAM
-ALL OVERHANGS SUBJECT TO LOCAL BYLAWS SIZED BY SUPPLIER
4
-ALL WALLS / CEILINGS / FLOORS THAT ARE COMMON TO
THIS PORTION TO BE
HOUSE AND GARAGE TO BE 1 HR. FIRE-RATED AND COMPLETE WHEN
GAS-PROOFED TO MEET CODE BASEMENT DEVELOPMENT
IS COMPLETED
-WEEPING TILE TO BE INSTALLED AROUND ALL STRIP
FOOTINGS AND TIED TO DRAINAGE SYSTEM MAIN FLOOR
9'-1"
FLOOR SLAB
TERMINATIONS
CENTRE OF
TO MATCH TOP OF
VERIFIED WITH PLOT PLAN AND / OR GRADES ON SIDE - FOOTING (APPROX. 5")
TO BE
CAPPED/LABELED
ENTRY STEPS TO BE ADJUSTED ACCORDINGLY
BASEMENT
-MAIN FLOOR ELEVATIONS TO TOP OF GARAGE SLAB CONCRETE SLAB
ELEVATION TO BE VERIFIED WITH A QUALIFIED SURVEYOR 4" EXHAUST
PERFORATED
-GLASS SHOWER DOOR / WALLS MUST BE TEMPERED GLASS WEEPING TILE PIPE
9'-0"
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGNER IN THE EVENT OF DISCREPANCIES.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND OTHER DATA NOTED HEREIN WITH CONDITIONS ON SITE.
WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
ENGINEERING AND ANY ENGINEER'S STAMPS TO BE THE SOLE RESPONSIBILITY OF THE BUILDER / CONTRACTOR / OWNER.
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
12"
MIN.
6"
12"
4"
APPLY SILL FLASHING
SILL EXTEND BUILDING PAPER OVER BUILDING PAPER
PAPER HORIZONTALLY 12" TO PROJECT AT SILL & CORNER
BEYOND VERTICAL JAMB FLASHING PATCHES AS SHOWN
INSTALL SELF-STICKING MEMBRANE OVER
APPLY BUILDING PAPER HORIZONTALLY BELOW SILL VULNERABLE CORNER INTERSECTIONS -SILL FLASHING CAN BE ADHESIVE MEMBRANES IF
-FASTEN TOP EDGE OF BUILDING PAPER TO WALL ASPHALT IMPREGNATED FELT OR COATED PAPER
SHEATHING - DO NOT FASTEN TO LOWER EDGE -DO NOT USE ADHESIVE BITUMEN-BASED MEMBRANES
-DRAINAGE PLANE TO BE SLID UP & UNDER LATER WITH PLASTIC HOUSEWRAP - USE BUILDING PAPER
BUILDING PAPER IN SHINGLE FASHION
4"
OF WINDOW
4" MIN. HORIZONTAL LAP
ON DRAINAGE PLANE
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
12"-16" LAP
6 mil VAPOUR 6 mil VAPOUR SEALANT OR ADHESIVE AS
6" MIN.
6" MIN.
BARRIER FOUNDATION LADDER BARRIER FOUNDATION LADDER ADHESIVE AS SHOWN
12"-16" LAP
12"-16" LAP
2x6 FROST WALL W/ 2x6 FROST WALL W/ SHOWN
BATT INSULATION BATT INSULATION ACOUSTIC
6 mil POLY VAPOUR 6 mil POLY VAPOUR SEALANT TO BE
AIRSPACE AIRSPACE BARRIER BARRIER
ACOUSTIC SEALANT TO BE USED USED IN ALL
8" CONCRETE WALL 8" CONCRETE WALL
IN ALL LOCATIONS TO PROVIDE LOCATIONS TO
ACOUSTIC SEALANT TO BE USED PARGING ACOUSTIC SEALANT TO BE USED PARGING
A COMPLETE VAPOUR BARRIER PROVIDE A
IN ALL LOCATIONS TO PROVIDE IN ALL LOCATIONS TO PROVIDE
DAMPROOFING DAMPROOFING COMPLETE
A COMPLETE VAPOUR BARRIER A COMPLETE VAPOUR BARRIER
VAPOUR BARRIER
AIR & VAPOUR SEALING @ FOUNDATION JUNCTION AIR & VAPOUR SEALING @ FOUNDATION JUNCTION AIR & VAPOUR SEALING @ FLOOR JUNCTION AIR & VAPOUR SEALING @ FLOOR
(PERPENDICULAR TO JOISTS) (PARALLEL TO JOISTS) (PERPENDICULAR TO JOISTS) JUNCTION
(PARALLEL TO JOISTS)
2'-0"
-CONTINUOUS DOWN TO FOOTING SHOWN CAULKING w/ END DAM
SHOWN AS REQUIRED (R60)
SEALANT OR
ADHESIVE AS FOUNDATION PRE-MANUFACTURED WALL ENSURE SYNTHETIC
LADDER TRUSS
SHOWN PLATE (INSTALL PRIOR TO BUILDING PAPER
MDF BOTTOM BOTTOM
SEALANT 8'-0" LONG 10M SIDING) OVERLAPS BUILDING
CHORD
REBAR @ 24" o.c . PAPER BELOW
6 mil VAPOUR PARGING
ACOUSTIC SEALANT TO BE USED SYNTHETIC BUILDING BUILDING PAPER
BARRIER DAMPROOFING 6 mil PAPER BEHIND WALL PLATE
IN ALL LOCATIONS TO PROVIDE RUBBER GASKET
AGGREGATE AS VAPOUR CASING (EXTEND MIN.6" AROUND)
A COMPLETE VAPOUR BARRIER HALF JAMB BLOCKING
PER BARRIER
NBC-AE 9.16.2.1(1) SLAB ABOVE FROST LINE DETAIL ATTIC ACCESS ATTIC ACCESS (PLAN VIEW)
SLAB / FOOTING JUNCTION WALL PENETRATION
EXTERIOR WALL ASSEMBLY ACOUSTIC SEALANT TO BE USED
AS REQUIRED IN ALL LOCATIONS TO PROVIDE
SEALED AS PER VENT PIPE
A COMPLETE VAPOUR BARRIER CLADDING AS PER SPEC.
9.36.2.10(15)
-CONTINUOUS WEATHER BARRIER BUILDING
SEALANT OR PAPER (LAP OVER FLASHING)
ADHESIVE AS SPRAY FOAM @
6 mil VAPOUR SHOWN WIRE PENETRATION
BARRIER
6 mil VAPOUR
BARRIER 6 mil VAPOUR 2x6 PLUMBING WALL
-CONTINUOUS BARRIER
SEALANT OR 6 mil BLOCKING
-CONTINUOUS
ADHESIVE AS VAPOUR
INTERIOR WALL SEALANT OR
SHOWN BARRIER ACOUSTIC SEALANT TO BE USED 6 mil PEEL & STICK (OR EQUIVILANT)
ADHESIVE AS BLOCKING 1/2" GD BOARD OUTLET BOX
IN ALL LOCATIONS TO PROVIDE TO ENSURE AIR BARRIER SEALED
SHOWN VAPOUR
POLY HAT AT PENETRATION
A COMPLETE VAPOUR BARRIER BARRIER AS PER 9.36.2.10(5) & (7)
INTERIOR / EXTERIOR WALL CONNECTION INTERIOR WALL @ CEILING VENT PIPE PENETRATION TYPICAL OUTLET BOX TYPICAL OUTLET BOX
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
AIR & VAPOUR SEALING @ RIM JOIST PENETRATION AIR & VAPOUR SEALING @ WALL PENETRATION AIR & VAPOUR BARRIER RECOMMENDED CUT PATTERN
6 mil VAPOUR CLADDING AS PER SPEC. WATERLINES TIGHT AS POSSIBLE TO FLOOR SHEATHING
ACOUSTIC SEALANT TO BE USED BARRIER -ALWAYS INSTALL ON THE FAR SIDE OF THE SECOND
IN ALL LOCATIONS TO PROVIDE
WEATHER BARRIER BUILDING JOIST SPACE
A COMPLETE VAPOUR BARRIER 5/8" TYPE 'X' DRYWALL AS
PAPER (LAP OVER FLASHING)
HIGH HEEL TRUSS REQUIRED WHEN CANTILEVER 5" HEAT DUCT INSTALL INSULATION AROUND
PROJECTS INTO SIDEYARD -CONTINUOUS IN TOP OF CAVITY RECTANGULAR DUCTS
ROOFING AS PER SPEC. SEALANT OR TO BE AS PER NBC-AE 9.36.3.2(5)
INSULATION STOP ADHESIVE AS
(ENSURE 6" LAP OVER SHEATHING PAPER) SHOWN R12 IB R20 FRICTION RECTANGULAR
6 mil VAPOUR FIT INSULATION DUCT
ROOF EDGE FLASHING FLOOR JOISTS (AS PER LOOSE-LAID BATT INSULATION
(COLOUR TO MATCH FASCIA) BARRIER
MANUFACTURER)
PAPER BEHIND
PREFINISHED 15" WIDE 3/8" OSB RIMBOARD
INSULATION STOP
GUTTER & FASCIA LADDER CAP
6 mil POLY
6 mil VAPOUR FOUNDATION RIGID INSULATION VAPOUR
PREFINISHED SOFFIT
12"-16" LAP
BARRIER LADDER OSB (FASTENED W/ DECK BARRIER
2 LAYER BUILDING AS PER NBC-AE 3.2.3.16 2x6 FROST WALL W/
-CONTINUOUS
6" MIN.
PAPER (16" MIN.) (SLOPE AWAY FROM HOUSE) SCREWS)
SEALANT OR BATT INSULATION
ADHESIVE AS 6 mil POLY VAPOUR PREFINISHED SOFFIT
ENSURE LAP OVER BUILDING PAPER OR TYVEK 2x6" @ 19.2" o.c.
SHOWN BARRIER
INSTALLED
CLADDING AS PER SPEC. BELOW JOISTS
6 mil VAPOUR AIRSPACE SLOPE AS PER LOT GRADING
BARRIER 8" CONCRETE WALL LAP WEATHER
ROOF EAVE PARGING BARRIER OVER 1/2" GD BOARD SECOND FLOOR
6 mil POLY VAPOUR ACOUSTIC SEALANT TO BE USED
PRE-FINISHED METAL
BARRIER CLADDING AS PER SPEC. IN ALL LOCATIONS TO PROVIDE DAMPROOFING
DRIP FLASHING
BATT OVER ATTACHED GARAGE
A COMPLETE VAPOUR BARRIER INSULATION
WEATHER BARRIER BUILDING AIR & VAPOUR SEALING @ FOUNDATION CANTILEVER CLADDING
-CONTINUOUS AS PER SPEC
PAPER (LAP OVER FLASHING) HEADER AS
SEALANT OR
ACOUSTIC SEALANT TO BE USED PER ENG.
ADHESIVE AS TRIM
IN ALL LOCATIONS TO PROVIDE
SHOWN METAL DRIP SPRAY FOAM
A COMPLETE VAPOUR BARRIER
FLASHING
WINDOW AS PER
WINDOW FRAME SPEC./SUPPLIER
FLOOR JOISTS RIMBOARD FLOOR JOISTS w/ CONTINUOUS
(AS PER (AS PER SEALANT BEHIND SHIMS
MANUFACTURER) METAL FLASHING MANUFACTURER) NAILING FLANGE
SEALANT AS REQ'D METAL DRIP JAMB EXTENSION
FLASHING AS PER SPEC.
-CONTINUOUS
ROOF
SEALANT OR
TRUSS
ADHESIVE AS SPRAY FOAM
TRIM
SHOWN
WEATHER BARRIER
ACOUSTIC SEALANT TO BE USED 6 mil POLY 2x6" @19.2" o.c. BUILDING PAPER
VAPOUR INSTALLED (LAP OVER FLASHING) BATT
IN ALL LOCATIONS TO PROVIDE
BARRIER BELOW JOISTS INSULATION
A COMPLETE VAPOUR BARRIER CLADDING
SECOND FLOOR OVER ATTACHED GARAGE SECOND FLOOR OVER ATTACHED GARAGE
AS PER SPEC.
@ GARAGE TRUSS @ HOUSE /GARAGE COMMON WALL WINDOW HEAD & SILL DETAIL
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
FOUNDATION WALL BLENDED RSI CALCULATION EXTERIOR AIR FILM 0.03 FOUNDATION WALL BLENDED RSI CALCULATION EARTH 0.00
-2x6 WALL @24" O.C. (140mm X 0.0085 RSI/mm) - 2x6 WALL @ 24" O.C. (140mm X 0.0085 RSI/mm)
(ABOVE GRADE) -R24 BATT INSULATION (152mm - RSI 4.23)
(BELOW GRADE) - R24 BATT INSULATION (152mm - RSI 4.23)
PARGING (4.8mm) 0.00432 NORMAL DENSITY CONCRETE (0.0004/mm) 0.08128
100 100
EXTERIOR AIR FILM RSI = DAMPPROOFING 0.00 RSI = AIR CAVITY (25mm) 0.00
%AREA OF CAVITY
PARGING ( % AREA OF FRAMING
RSLF ) ( +
RSIC ) EARTH ( % AREA OF FRAMING
RSIF ) ( +
% AREA OF CAVITY
RSIC )
NORMAL DENSITY CONCRETE (0.0004/mm) 0.08128 BLENDED RSI FROM CALCULATION 3.17543
DAMPPROOFING 100 DAMPPROOFING 100
RSI = RSI =
NORMAL DENSITY 87
CONCRETE (203mm) ( 13
140 X 0.0085 ) ( +
4.23 ) AIR CAVITY (12.7mm) 0.00 NORMAL DENSITY CONCRETE ( 13
140 X 0.0085
) ( +
87
4.23 ) VAPOUR BARRIER 0.00
(203mm)
AIR CAVITY (12.7mm)
100
BLENDED RSI FROM CALCULATION 3.17543 100
GYPSUM (12.7mm) 0.08
RSI = AIR CAVITY (25mm) RSI =
87 87
R24 BATT INSULATION
(152mm)
( 13
1.19 ) ( +
4.23 ) VAPOUR BARRIER 0.00 R24 BATT INSULATION (152mm)
( 13
1.19 ) ( +
4.23 ) INTERIOR AIR FILM 0.12
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
BUILDING PAPER
( 5.80495 ) (
+ 26.27841 ) TYPE "X" GYPSUM BOARD ( 16.80672 ) (+ 20.67183 ) GYPSUM BOARD (12.7mm) ( 19.32773 ) ( + 19.89664 )
(15.9mm)
INTERIOR AIR FILM 0.12
PREFINISHED METAL SOFFIT 100 100 INTERIOR AIR FILM 100
RSI = INTERIOR AIR FILM RSI = RSI =
32.08336 37.47856 39.22437
EXTERIOR AIR FILM
RSI = 3.11688 RSIEFF 5.08 RSI = 2.66819 RSIEFF 3.12 RSI = 2.54944 RSIEFF 4.28
( % AREA OF FRAMING
) (
+
%AREA OF CAVITY
) BLENDED RSI FROM ( % AREA OF FRAMING
RSLF ) ( +
RSIC ) BLENDED RSI CALCULATION 2.76542
RSLF RSIC 1.83047
2x4 BOTTOM CHORD 100 CALCULATION 100
EXTRUDED POLYSTYRENE (63.5mm X 0.0336) 2.1336 (89mm) RSI = RSI =
88.5
TOP LAYER OF R12 BATT 2.11
EARTH BLOWN-IN (CELLULOSE)
( 11
89 x 0.0085 ) ( +
89
89 x 0.025 ) VAPOUR BARRIER 0.00 INTERIOR AIR FILM ( 11.5
140 X 0.0085 ) ( +
3.34 ) INSULATION
PARGING (4.8mm) NORMAL DENSITY CONCRETE (0.0004/mm) 0.08128 (89mm)
100 6 mil POLY VAPOUR 100
2 1/2" EXTRUDED RSI = GYPSUM (12.7mm) 0.08 BARRIER
RSI = VAPOUR BARRIER 0.00
6 mil POLY VAPOUR 88.5
POLYSTYRENE
DOWN TO FOOTING RSIEFF 2.22 BARRIER ( 11
0.7565 ) ( +
89
2.22 ) ( 11.5
1.19 ) ( +
3.34 )
(63.5mm) INTERIOR AIR FILM 0.11 R12 FRICTION FIT BATT 100
INTERIOR AIR FILM 0.16
100
RSI = INSULATION (89mm) RSI =
DAMPPROOFING
NORMAL DENSITY
GYPSUM BOARD
(12.7mm) ( 14.54065 ) ( + 40.09 ) R20 FRICTION FIT BATT
( 9.66387 ) ( + 26.49701 )
CONCRETE
100 INSULATION (140mm) 100
(203mm) RSI = RSI =
INTERIOR AIR FILM 54.63065 36.16087
GYPSUM BOARD (12.7mm)
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K
2ND FLOOR
45 MINUTE FIRE RATED BLENDED RSI CALCULATION
-2x6 WALL @16" O.C. (140mm X 0.0085 RSI/mm)
EXTERIOR AIR FILM 0.03
VINYL SIDING ON BUILDING PAPER (HOUSE WALLS) -R24 BATT INSULATION (140mm - RSI 4.23)
5/8" TYPE 'X' GYPSUM BOARD VINYL SIDING (HOLLOW BACKED) 0.11
2"X6" STUD WALL @ 16" O/C 100
EXTERIOR AIR FILM
R-22 FIBERGLASS BATT INSULATION 6 MIL CGSB VAPOR RSI =
%AREA OF CAVITY
BUILDING PAPER 0.00
6 MIL CGSB VAPOR BARRIER CLADDING AS PER SPEC. ( % AREA OF FRAMING
RSLF ) (
+
RSIC )
TYPE X GYPSUM (15.88mm) 0.100
5/8" TYPE 'X' GYPSUM BOARD WEATHER BARRIER 100
BUILDING PAPER (LAP RSI =
*STUD WALL MORE THAN 16" O/C REQUIRE BLOCKING 77
2x FLOOR JOISTS
FLASHING
BASEMENT
PROTECTIVE MEMBRANE DAMPPROOFING 8" CONC. MIN 2% SL
OP
CLIENT: DRAWING TITLE FLOOR AREA INFO SUBDIVISION: IRVINE CREEK DATE STARTED:27-09-2024 JOB #:4317
MAIN FLOOR : 1,392 SQ. FT. DESIGNER: RANGARAJ.K