Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

eskkkd

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

MODEL: KD

Plug-in Signal Conditioners K-UNIT C: 110 V AC


D: 115 V AC
F: 120 V AC
CURRENT LOOP SUPPLY G: 200 V AC
(non-isolated) H: 220 V AC
Functions & Features J: 240 V AC
• Powering a 4 – 20 mA DC current loop
• Output voltage 24 V or 42 V
• Electrically isolating output signal from power input [3] OPTIONS
• Shortcircuit protection blank: none
• Applicable to smart transmitters /Q: With options (specify the specification)
• High-density mounting
SPECIFICATIONS OF OPTION: Q (multiple selections)
Typical Applications COATING (For the detail, refer to our web site.)
• Various 2-wire transmitters /C01: Silicone coating
• 42 V output provides increased loop drive /C02: Polyurethane coating
50 /C03: Rubber coating
(1.97)
TERMINAL SCREW MATERIAL
/S01: Stainless steel
80
K-UNIT
(3.15)
RELATED PRODUCTS
• Resistor module (model: REM-250)
123
(4.84)
mm (inch)
GENERAL SPECIFICATIONS
Construction: Plug-in
Connection: M3.5 screw terminals
MODEL: KD–[1]–[2][3]
Screw terminal: Chromated steel (standard) or stainless
steel
ORDERING INFORMATION Housing material: Flame-resistant resin (black)
• Code number: KD-[1]-[2][3] Isolation: Input or output to power
Specify a code from below for each of [1] through [3].
(e.g. KD-24-B/Q)
SUPPLY OUTPUT
• Specify the specification for option code /Q
Output voltage (with no load):
(e.g. /C01/S01)
24 V use: 24 – 28 V DC
42 V use: 39 – 43 V DC
[1] SUPPLY OUTPUT Current rating: ≤ 22 mA DC
24: 24 V DC • Shortcircuit Protection
42: 42 V DC Current limited: 40 mA max.
Protected time duration: No limit

INPUT
Current INSTALLATION
4 – 20 mA DC Supply voltage
Operational voltage range: Rating ±10 %
50/60 ±2 Hz
OUTPUT
Approx. 2 VA (KD-24)
Current
Approx. 3.2 VA (KD-42)
4 – 20 mA DC
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
[2] POWER INPUT Mounting: Surface or DIN rail
AC Power Weight: 300 g (0.66 lb)
B: 100 V AC
KD SPECIFICATIONS ES-3592 Rev.10 Page 1/3

MG CO., LTD.
www.mgco.jp
MODEL: KD
PERFORMANCE in percentage of span
Line voltage effect
KD-24: ±0.5 % over voltage range
KD-42: ±1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input or output
to power to ground)

EXTERNAL DIMENSIONS unit: mm [inch]


CLAMP
(top & bottom)
7.8 [.31]

[.79]
20
DIN RAIL
35mm wide 6 5 4 3
80 [3.15]

80 [3.15]
2–4.5 [.18] dia.
MTG HOLE
15 [.59] deep
7 8 1 2
8–M3.5
SCREW
50 [1.97] 103 [4.06] 40 [1.57]
123 [4.84] (3.3 [.13]) 50 [1.97]

• When mounting, no extra space is needed between units.

TERMINAL ASSIGNMENTS unit: mm [inch]


OUTPUT RESISTOR
(model: REM)

6 5 4 3
12 (.47)

7 8 1 2

Use output shunt resistor


for voltage output.

KD SPECIFICATIONS ES-3592 Rev.10 Page 2/3

MG CO., LTD.
www.mgco.jp
MODEL: KD
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

2-WIRE
TRANSMITTER
– – 6 * +
3
R OUTPUT 1
Current
+ + 1 4 –
Limiter
**
5 +
OUTPUT 2
2 –

7 U
POWER
8 V

Base Socket

* Use output shunt resistor for voltage output.


**Be sure to short-circuit if not using output 2.
Note: Use 250Ω load resistance when combined with a smart transmitter.

Specifications are subject to change without notice.

KD SPECIFICATIONS ES-3592 Rev.10 Page 3/3

MG CO., LTD.
www.mgco.jp