API 650 Answers
API 650 Answers
Submitted
a) Maximum pressure shall not exceed 15 psig
c) Maximum pressure shall not exceed the weight of the roof plates
d) Maximum pressure shall not exceed the weight of the floor plates
Correct
a) Maximum pressure shall not exceed 15 psig
c) Maximum pressure shall not exceed the weight of the roof plates
d) Maximum pressure shall not exceed the weight of the floor plates
Answer is
Correct
a) Any petrochemical service and temperature not exceeding 120°F
Submitted
a) API-650 providing the requirements of Appendix F are met
Correct
a) API-650 providing the requirements of Appendix F are met
b) API-653 providing the requirements of Appendix F are met
Submitted
a) The paragraph requires a decision or action by the API
Correct
a) The paragraph requires a decision or action by the API
Submitted
a.Purchaser.
b. Fabricator.
c. Inspector.
d. Erector.
Correct
a.Purchaser.
b. Fabricator.
c. Inspector.
d. Erector.
Answer is
Q 6. Requirements of tanks with design temperature exceeding 200ºF
to 500ºF is covered in:
Submitted
a.Annexure A.
b. Annexure M
c. Annexure N
d. Annexure O
Correct
a.Annexure A.
b. Annexure M
c. Annexure N
d. Annexure O
Answer is
Submitted
a.Actual thickness.
b.Ordered thickness.
c.Structural thickness.
d. Corroded thickness
Correct
a.Actual thickness.
b.Ordered thickness.
c.Structural thickness.
d. Corroded thickness
Answer is
Q 8. If lowest one day mean temperature of a location is 30ºF what is
the design metal temperature of tank installed at that location?
Submitted
a. 30ºF
b. 45ºF
c. 15ºF
d. 8ºF
Correct
a. 30ºF
b. 45ºF
c. 15ºF
d. 8ºF Answer is
Submitted
a. Coating
b. Painting
c. Liner.
Correct
a. Coating
b. Painting
c. Liner.
Submitted
a. Maximum specific gravity of the stored liquid.
Q 11. The outer periphery of the roof consists of closed-top pontoon
compartments, with the inner section of the roof constructed of a
single deck without flotation mean is a:
Submitted
a. Single deck pontoon fixed roof.
Correct
a. Single deck pontoon fixed roof.
b. Actual thickness.
c. Nominal thickness.
d. Original thickness
Correct
a. Design thickness.
b. Actual thickness.
c. Nominal thickness.
d. Original thickness
Answer is
Q 13. When tanks are to be designed for multiple products the specific
gravity used for floating roof design is:
Submitted
a. Maximum specific gravity of the stored liquid.
Correct
a. Maximum specific gravity of the stored liquid.
Q 14. This thickness which includes any corrosion allowance and is used
for determination of PWHT requirements, weld spacing, minimum
and maximum thickness limitations is :
Submitted
a.Minimum required thickness.
b.Nominal thickness
c.Ordered thickness.
d.Both b & c
Correct
a.Minimum required thickness.
b.Nominal thickness
c.Ordered thickness.
d.Both b & c
Answer is
Submitted
a. Contractor
b. Purchaser.
c. Manufacturer.
d. User.
Correct
a. Contractor
b. Purchaser.
c. Manufacturer.
d. User.
Answer is
Q 16. A steel plate that replaces part of a shell plate, with a nominal
thickness that is greater than the nominal thickness of the
adjoining material by more than 3 mm is
Submitted
a. Insert plate.
c. Flush plate.
Correct
a. Insert plate.
c. Flush plate.
Answer is
Q 17. API-650 lists materials to be used in the construction of tanks
covered by the standard. Is it permissible to use materials other
than those listed in the standard?
Submitted
a) No only materials listed in API-650 may be used in tank fabrication
b) Yes as long as the manufacturer accepts full liability for tank failure
c) Yes providing it is certified as meeting all requirements of a material listed in API- 650 and is
d) Yes providing it is certified as meeting all the requirements of a material listed in API-650 and
is approved by the purchaser
Correct
a) No only materials listed in API-650 may be used in tank fabrication
b) Yes as long as the manufacturer accepts full liability for tank failure
c) Yes providing it is certified as meeting all requirements of a material listed in API- 650 and is
approved by the API-653 Inspector
d) Yes providing it is certified as meeting all the requirements of a material listed in API-650 and
Submitted
a) Yes only if the material passes the tests prescribed in Appendix S
d) Yes only if the material passes the tests prescribed in ASME Section VIII,Div. 2
Correct
a) Yes only if the material passes the tests prescribed in Appendix S
c) Yes only if the material passes the tests prescribed in ASME Section V
d) Yes only if the material passes the tests prescribed in ASME Section VIII,Div. 2
Answer is
Q 19. What is the maximum permitted underrun for shell, roof, and
bottom plates?
Submitted
a) 0.10 inch from the computed design thickness or minimum permitted thickness
b) 0.01 inch from the computed design thickness or minimum permitted thickness
c) 0.001 inch from the computed design thickness or minimum permitted thickness
d) 0.02 inch from the computed design thickness or minimum permitted thickness
Correct
a) 0.10 inch from the computed design thickness or minimum permitted thickness
b) 0.01 inch from the computed design thickness or minimum permitted thickness
c) 0.001 inch from the computed design thickness or minimum permitted thickness
d) 0.02 inch from the computed design thickness or minimum permitted thickness
Answer is
Q 20. Shell plates are limited to what maximum thickness?
Submitted
a) Shell plates are limited to a maximum thickness of 1.250 inches
Correct
a) Shell plates are limited to a maximum thickness of 1.250 inches
Q 21. Which of the following is not a requirement for shell plates that are
thicker than 1.5 inches?
Submitted
a) Plates thicker than 1.5 inches shall be free of mill scale and painted
Correct
a) Plates thicker than 1.5 inches shall be free of mill scale and painted
b) Plates thicker than 1.5 inches shall be made to fine-grain practice
d) Plates thicker than 1.5 inches shall be normalized or quench tempered Answer is
Q 22. What is the maximum shell plate thickness permitted for a tank
fabricated of ASTM A36 material?
Submitted
a) This plate material is limited to 1.750 inches
Correct
a) This plate material is limited to 1.750 inches
Q 23. What is the maximum shell plate thickness permitted for a tank
fabricated of ASTM A285, Grade C material?
Submitted
a) This plate material is limited to 1.000 inches
b) This plate material is limited to 1.250 inches
Correct
a) This plate material is limited to 1.000 inches
Q 24. All welding to repair surface defects shall be done with ______.
Submitted
a) Cellulose coated electrode
c) Low-hydrogen electrode
Correct
a) Cellulose coated electrode
c) Low-hydrogen electrode
Q 25. When conducting impact tests, how many specimens are required
from a single test coupon?
Submitted
a) Impact tests shall be performed on a single specimen taken from a single test coupon
b) Impact tests shall be performed on two specimens taken from a single test coupon
c) Impact tests shall be performed on three specimens taken from a single test coupon
d) Impact tests shall be performed on four specimens taken from a single test coupon
Correct
a) Impact tests shall be performed on a single specimen taken from a single test coupon
b) Impact tests shall be performed on two specimens taken from a single test coupon
c) Impact tests shall be performed on three specimens taken from a single test coupon
d) Impact tests shall be performed on four specimens taken from a single test coupon
Answer is
Submitted
a) 60% of the material thickness
Correct
a) 60% of the material thickness
Q 27. Unless data is available to justify a different temperature, what
must the design metal temperature be for an aboveground storage
tank to be installed in Birmingham, Alabama?
Submitted
a) The design temperature shall be assumed to be 25°F
Correct
a) The design temperature shall be assumed to be 25°F
Q 28. Unless data is available to justify a different temperature, what
must the design metal temperature be for an aboveground storage
tank to be installed in Indianapolis, Indiana?
Submitted
a) The design temperature shall be assumed to be 5°F
Correct
a) The design temperature shall be assumed to be 5°F
Q 29. What is the required average longitudinal impact value of three
specimens taken from a 1.375 inch thick A 516-60 normalized
Group IIIA test coupon?
Submitted
a) 30 foot-pounds
b) 20 foot-pounds
c) 15 foot-pounds
d) 13 foot-pounds
Correct
a) 30 foot-pounds
b) 20 foot-pounds
c) 15 foot-pounds
d) 13 foot-pounds Answer is
Q 30. What is the required average longitudinal impact value of three
specimens taken from a 1.5 inch thick A 516-70 as rolled Group IV
test coupon?
Submitted
a) 35 foot-pounds
b) 25 foot-pounds
c) 20 foot-pounds
d) 30 foot-pounds
Correct
a) 35 foot-pounds
b) 25 foot-pounds
c) 20 foot-pounds
d) 30 foot-pounds
Answer is
Q 31. Longitudinal impact tests are performed on three specimens, taken
from a 1.5 inch thick A 516-70 as rolled test coupon with the
following results:
Specimen #1 – 42 foot-pounds,
Specimen #2 – 18 foot-pounds,
Specimen # 3 – 31 foot-pounds.
Is the impact test acceptable?
Submitted
a) Yes the average impact value exceeds 30 foot-pounds
b) Yes only one specimen is less than 2/3 the specified minimum value
c) No the average impact value of Specimen # 1 exceeds 2/3 the required average impact value
and one specimen is less than 2/3 the specified minimum value
Correct
a) Yes the average impact value exceeds 30 foot-pounds
b) Yes only one specimen is less than 2/3 the specified minimum value
c) No the average impact value of Specimen # 1 exceeds 2/3 the required average impact value
and one specimen is less than 2/3 the specified minimum value
Q 32. Two plates sample A and B were tested for longitudinal impact
testing. Following were results observed. They belonged to Group
No.I as per API 650: Results of impact test for
Sample A were 18ft lb, 8ft lb, 16ft lb.
Sample B were 12ft lb, 14ft lb, 20 ft. lb
Your assessment will be:
Submitted
a) sample A and B both OK
Correct
a) sample A and B both OK
Q 33. What is the MDMT without impact testing for A 516 Gr.60 as
rolled ,killed material of 1.25 inch thickness.
Submitted
a) 40 deg.F
b) 5 deg.F.
c) 25 deg.F.
d.10 deg.F
Correct
a) 40 deg.F
b) 5 deg.F.
c) 25 deg.F.
d.10 deg.F
Answer is
Q 34. If retesting is done due to the impact test failure which of the
following requirements should be met?
Submitted
a. Each of the additional specimen must have a value greater than or equal to the specified
minimum value.
b. At least two specimens must have a value greater than or equal to the specified minimum
value.
c. At least one specimen must have a value greater than or equal to the specified minimum value.
Correct
a. Each of the additional specimen must have a value greater than or equal to the specified
minimum value.
b. At least two specimens must have a value greater than or equal to the specified minimum
value.
c. At least one specimen must have a value greater than or equal to the specified minimum value.
Submitted
a. ASTM A 120.
b. ASTM A 370.
c. API 650.
d. ASME IX
Correct
a. ASTM A 120.
b. ASTM A 370.
c. API 650.
d. ASME IX
Answer is
Submitted
a) Pressing or other non-injurious method prior to layout or shaping
Correct
a) Pressing or other non-injurious method prior to layout or shaping
Q 37. When plates are to be butt-welded, shearing is limited to what
maximum thickness?
Submitted
a) 5/8th inch
b) 3/8th inch
c) 3/16th inch
Correct
a) 5/8th inch
b) 3/8th inch
c) 3/16th inch
Q 38. When plates are to be used in lap-welded joints, shearing is limited
to what maximum thickness
Submitted
a) 3/16th inch
b) 3/8th inch
c) 1/2 inch
d) 5/8th inch
Correct
a) 3/16th inch
b) 3/8th inch
c) 1/2 inch
Q 39. What are the requirements regarding mill test reports according to
API- 650?
Submitted
a) No material shall be used in the construction of an AST unless it is accompanied by a mill test
report
c) Mill test reports shall be furnished to the purchaser only when specified in the original
purchase order
d) Mill test reports shall be furnished to the purchaser prior to final acceptance of the AST
Correct
a) No material shall be used in the construction of an AST unless it is accompanied by a mill test
report
c) Mill test reports shall be furnished to the purchaser only when specified in the original
purchase order
d) Mill test reports shall be furnished to the purchaser prior to final acceptance of the AST
Answer is
Q 40. Attachments that will be welded to the pressure boundary shall
not have a zinc or cadmium coating in the weld area within ______of
the weld.
Submitted
a) 1.0 inch
b) 0.5 inch
c) 0.75 inch
d) 0.25 inch
Correct
a) 1.0 inch
b) 0.5 inch
c) 0.75 inch
d) 0.25 inch
Answer is
Q 41. What is the maximum length of lamination which can be repaired
by edge gouging and re welding?
Submitted
a) 1 inch
b) 2 inches.
c) 3 inches.
Correct
a) 1 inch
b) 2 inches.
c) 3 inches.
Submitted
a) The welding operator or welder
d) The erection manufacturer or the fabrication manufacturer if other than the erection
manufacturer.
Correct
a) The welding operator or welder
d) The erection manufacturer or the fabrication manufacturer if other than the erection
manufacturer.
Answer is
Submitted
a) This material would be included in Group number 2
Correct
a) This material would be included in Group number 2
Q 44. The welder or welding operator’s identification mark shall be hand-
or machine-stamped adjacent to and at intervals not exceeding
____.
Submitted
a. 3 feet
b. 5 feet.
c. 10 feet
d. 6 inches
Correct
a. 3 feet
b. 5 feet.
c. 10 feet
d. 6 inches Answer is
Submitted
a) The coating shall be removed and does not affect the weld and therefore does not need to be
addressed
Correct
a) The coating shall be removed and does not affect the weld and therefore does not need to be
addressed
b) 32°F
c) 60°F
d) 0°F
Correct
a) 50°F
b) 32°F
c) 60°F
d) 0°F
Answer is
Q 47. Materials to be used at a design metal temperature below ____, the
qualification of the welding procedure for all joints shall include
impact tests of the weld metal.
Submitted
a. 50°F
b. 32°F
c. 60°F
d. 20°F
Correct
a. 50°F
b. 32°F
c. 60°F
d. 20°F Answer is
Submitted
a) Shell horizontal weld joints
Correct
a) Shell horizontal weld joints
Submitted
a) This nameplate shall be attached to the tank shell adjacent to a manhole or to a manhole
b) This nameplate shall be attached to the tank shell adjacent to a vertical weld joint least 48”
c) This nameplate shall be attached to the tank shell adjacent to a manhole or to a manhole
reinforcing plate immediately above the manhole
d) This nameplate shall be attached to the tank shell adjacent to a manhole or to a manhole
Correct
a) This nameplate shall be attached to the tank shell adjacent to a manhole or to a manhole
b) This nameplate shall be attached to the tank shell adjacent to a vertical weld joint least 48”
c) This nameplate shall be attached to the tank shell adjacent to a manhole or to a manhole
d) This nameplate shall be attached to the tank shell adjacent to a manhole or to a manhole
Submitted
a) The manufacturer shall provide the purchaser with a U-1 Data Report form
Compliance”
d) The manufacturer shall provide the purchaser with a notarized certificate of compliance
Correct
a) The manufacturer shall provide the purchaser with a U-1 Data Report form
c) The manufacturer shall provide the purchaser with an ASME acceptable “Certificate of
Compliance”
d) The manufacturer shall provide the purchaser with a notarized certificate of compliance
Answer is
Q 51. What should be the minimum size letters or numbers used in tank
name plate?
Submitted
a .1/16 inch.
b. 5/32 inch.
c. 1/8 inch.
d. 3/32 inch
Correct
a .1/16 inch.
b. 5/32 inch.
c. 1/8 inch.
d. 3/32 inch
Answer is
Q 52. When only flush-type cleanout fittings and flush-type shell
connections have been thermally stress relieved the symbol used
in name plate is:
Submitted
a. SR2
b. SR1
c. SR3
d. SR4
Correct
a. SR2
b. SR1
c. SR3
d. SR4
Answer is
Submitted
a) 7/8th inch
b) 3/4th inch
c) 5/8th inch
d) 1/2 inch
Correct
a) 7/8th inch
b) 3/4th inch
c) 5/8th inch
Q 54. What is the maximum tensile stress, before the joint efficiency is
applied, permitted in the design of small tanks in accordance with
Appendix A of API-650?
Submitted
a) 21000 psi
b) 21500 psi
c) 21000 ksi
d) 21500 ksi
Correct
a) 21000 psi
b) 21500 psi
c) 21000 ksi
d) 21500 ksi
Answer is
Q 55. When computing the tension in each ring (course) of a small tank
designed in accordance with Appendix A of API-650, where is this
tension computed?
Submitted
a) The tension shall be computed 12 inches above the centerline of the course in question
b) The tension shall be computed 12 inches above the centerline of the lower horizontal joint of
c) The tension shall be computed 12 inches above the centerline of the tank in question
d) The tension shall be computed 12 inches below the centerline of the upper horizontal joint of
Correct
a) The tension shall be computed 12 inches above the centerline of the course in question
b) The tension shall be computed 12 inches above the centerline of the lower horizontal joint of
c) The tension shall be computed 12 inches above the centerline of the tank in question
d) The tension shall be computed 12 inches below the centerline of the upper horizontal joint of
Q 56. What joint efficiency factor shall be used in the design of small
tanks designed in accordance with Appendix A of API-650 when
spot radiographic examination is applied?
Submitted
a. 1.00
b. 0.90
c. 0.85
d. 0.70
Correct
a. 1.00
b. 0.90
c. 0.85
d. 0.70
Answer is
Q 57. What joint efficiency factor shall be used in the design of small
tanks designed in accordance with Appendix A of API-650 when
spot radiographic examination is omitted?
Submitted
a) 1.00
b) 0.90
c) 0.85
d) 0.70
Correct
a) 1.00
b) 0.90
c) 0.85
d) 0.70
Answer is
Q 58. What is the capacity of 36 feet height and 40 feet diameter tank?
Submitted
a. 8060 barrels.
b. 6710 barrels.
c. 9400 barrels.
Correct
a. 8060 barrels.
b. 6710 barrels.
c. 9400 barrels.
Q 59. If the owner does not specify an alternative grade slope, the
finished tank grade shall be crowned from its outer periphery to
its center at a slope of _____.
Submitted
a) The slope shall be one inch in twelve feet
Correct
a) The slope shall be one inch in twelve feet
Submitted
a) Earth foundations should provide a stable plane for support of the tank
b) Earth foundations should limit settlement to values used in the design of the connecting
piping
c) Earth foundations should not settle excessively at the perimeter due to the weight of the tank
d) Earth foundations should reinforced with steel reinforcing bar to prevent sagging
Correct
a) Earth foundations should provide a stable plane for support of the tank
b) Earth foundations should limit settlement to values used in the design of the connecting
piping
c) Earth foundations should not settle excessively at the perimeter due to the weight of the tank
d) Earth foundations should reinforced with steel reinforcing bar to prevent sagging
Answer is
Submitted
a) When there is some doubt whether the foundation will be able carry the shell load directly
b) When there will be an area in the foundation open for passing cathodic protection equipment
through
c) When the tank is located in an area that is easily accessible for pouring the concrete
d) When the tank erector decides a concrete foundation will be easier to install
Correct
a) When there is some doubt whether the foundation will be able carry the shell load directly
b) When there will be an area in the foundation open for passing cathodic protection equipment
through
c) When the tank is located in an area that is easily accessible for pouring the concrete
d) When the tank erector decides a concrete foundation will be easier to install
Answer is
Submitted
a) The ringwall shall not be less than 8 inches
Correct
a) The ringwall shall not be less than 8 inches
Q 63. How far below the lowest adjacent finish grade must the bottom
of the ringwall, if founded on soil, be located?
Submitted
a) The bottom of the ringwall shall be located 1 foot below grade
b) The bottom of the ringwall shall be located 1.5 feet below grade
c) The bottom of the ringwall shall be located 2.5 feet below grade
Correct
a) The bottom of the ringwall shall be located 1 foot below grade
b) The bottom of the ringwall shall be located 1.5 feet below grade
c) The bottom of the ringwall shall be located 2.5 feet below grade
Submitted
a) Minimum 0.1 inch.
Correct
a) Minimum 0.1 inch.
Q 65. The minimum required thickness for Sleeves and fittings on the
single deck or lower decks of annular pontoons or lower decks of
double-deck Roofs is:
Submitted
a) ¼ inch.
b) ½ inch.
c) 3/8 inch.
d) 3/16 inch.
Correct
a) ¼ inch.
b) ½ inch.
c) 3/8 inch.
d) 3/16 inch.
Answer is
Q 66. What should be the width and thickness of the shunts provided
on the external floating roof?
Submitted
a) Width 3 inch thickness ¼ inch.
Correct
a) Width 3 inch thickness ¼ inch.
Q 67. Top decks of double-deck roofs and of pontoon sections, which
are designed with a permanent slope shall be designed,
fabricated, and erected with a minimum slope of:
Submitted
a) 1 in 32
b) 1 in 64
c) 2 in 12
d) 1 in 120
Correct
a) 1 in 32
b) 1 in 64
c) 2 in 12
d) 1 in 120 Answer is
Q 68. What is the minimum rainfall where single deck Floating roofs
shall have sufficient buoyancy to remain afloat on liquid?
Submitted
a) 12 inch in 12 hour period.
Correct
a) 12 inch in 12 hour period.
Q 69. Each pontoon compartment shall be provided with a liquid-tight
manhole with a minimum nominal size of :
Submitted
a. NPS 24.
b. NPS 30.
c. NPS 20
d. NPS 36.
Correct
a. NPS 24.
b. NPS 30.
c. NPS 20
d. NPS 36.
Answer is
Q 70. Floating roof ladder shall have full-length handrails on both
Sides and shall be designed for a ____midpoint load.
Submitted
a. 5000 lbf
b. 2000 lbf
c. 1000 lbf
d. 3000 lbf
Correct
a. 5000 lbf
b. 2000 lbf
c. 1000 lbf
d. 3000 lbf Answer is
Q 71. what should be the size of primary drain for 130 feet diameter
tank.
Submitted
a. NPS 4
b. NPS 3
c. NPS 2
d. NPS 3.5.
Correct
a. NPS 4
b. NPS 3
c. NPS 2
d. NPS 3.5.
Answer is
Submitted
a. 3.
b. 4
c. 2
d. 1
Correct
a. 3.
b. 4
c. 2
d. 1
Answer is
Submitted
a. 2
b. 3
c. 4
d. 1
Correct
a. 2
b. 3
c. 4
d. 1
Answer is
Q 74. A vapour-tight rim (or skirt), extending at least ____ above the
liquid at the design flotation level, shall be provided around both
the internal floating roof periphery and around all internal
floating roof penetrations.
Submitted
a) 6 inch.
b) 12 inch
c) 18 inch.
d) 14 inch
Correct
a) 6 inch.
b) 12 inch
c) 18 inch.
d) 14 inch
Answer is
Q 75. A peripheral seal (also referred to as “rim seal”) that spans the
annular space between the internal floating roof deck and the
shell shall be provided. When an internal floating roof has two
such devices, one mounted above the other, the lower is the
____________ and the upper is the ___________:
Submitted
a) Primary peripheral seal and secondary peripheral seal. .
Submitted
a) Flouropolymers.
b) urethane laminate.
c) fluoroelastomers, or Buna-N-Vinyl
Correct
a) Flouropolymers.
b) urethane laminate.
c) fluoroelastomers, or Buna-N-Vinyl
b) ±5 inch.
c) ±10 inch.
d) ±12 inch
Correct
a) ±6 inch.
b) ±5 inch.
c) ±10 inch.
d) ±12 inch
Answer is
Submitted
a) 64 feet.
b) 30 feet.
c) 32 feet.
d) 50 feet
Correct
a) 64 feet.
b) 30 feet.
c) 32 feet.
d) 50 feet Answer is
Submitted
a) 1× 10ˉ⁷ cm
b) 2× 10ˉ⁷ cm.
c) 3× 10ˉ⁷ cm.
d) 4× 10ˉ⁷ cm
Correct
a) 1× 10ˉ⁷ cm
b) 2× 10ˉ⁷ cm.
c) 3× 10ˉ⁷ cm.
d) 4× 10ˉ⁷ cm
Answer is
Submitted
a) 20% and 40%.
b) 20% and 20%.
Correct
a) 20% and 40%.
Q 81. in flaw documentation written documentation shall be produced
for each unacceptable flaw and those acceptable flaws that either
exceed ___of reference level for amplitude based techniques or
exceed
___ of the acceptable length for non-amplitude techniques.
Submitted
a) 50% and 75%.
Correct
a) 50% and 75%.
Q 82. With regards to radiographic examination of welded joints, API-
650 considers plates to be the same thickness when the difference
in their specified or design thickness is not greater than ____.
Submitted
a) 1/32nd inch
b) 1/16th inch
c) 3/32nd inch
d) 1/8th inch
Correct
a) 1/32nd inch
b) 1/16th inch
c) 3/32nd inch
d) 1/8th inch
Answer is
Submitted
a) Bottom-plate welds and roof plates.
Correct
a) Bottom-plate welds and roof plates.
Q 84. Vertical butt welds in plates not greater than 3/8th inch thick,
require one spot radiograph to be taken in the first _____ of
completed vertical joint of each type and thickness by each welder
or welding operator.
Submitted
a) 100 feet
b) 50 feet
c) 25 feet
d) 10 feet
Correct
a) 100 feet
b) 50 feet
c) 25 feet
d) 10 feet
Answer is
Q 85. Vertical butt welds in plates not greater than 3/8th inch thick, One
additional spot radiograph shall be taken in each additional ____ of
vertical joint of the same type and thickness.
Submitted
a) 10 feet
b) 200 feet
c) 100 feet
d) 25 feet
Correct
a) 10 feet
b) 200 feet
c) 100 feet
d) 25 feet
Answer is
Q 86. Vertical butt welds in plates not greater than 3/8th inch thick, what
percentage of the selected spot radiographs must be at junctions of
vertical and horizontal welded joints?
Submitted
a) 25 percent
b) 50 percent
c) 75 percent
d) 15 percent
Correct
a) 25 percent
b) 50 percent
c) 75 percent
d) 15 percent
Answer is
Q 87. For butt welded joints in plates over 3/8” to not over 1” in
thickness are required to be radiographically examined to the same
extent as plates 3/8” and less. What additional spot examination
does API-650 require for these welded joints?
Submitted
a) 50 percent of all vertical and horizontal junctions
d) 25 percent of all horizontal joints between the first and second course
Correct
a) 50 percent of all vertical and horizontal junctions
d) 25 percent of all horizontal joints between the first and second course
Answer is
Q 88. The radiographic film for all junctions of vertical and horizontal
joints shall show at least ____ of weld length on each side of the
vertical intersection.
Submitted
a) 3 inches
b) 2 inches
c) 1 inch
d) 4 inches
Correct
a) 3 inches
b) 2 inches
c) 1 inch
d) 4 inches
Answer is
Q 89. The butt weld around the periphery of an insert manhole or nozzle
shall be ____.
Submitted
a) Completely examined by liquid penetrant methods
Correct
a) Completely examined by liquid penetrant methods
Q 90. After the initial spot radiograph in the first 10 feet of horizontal
butt joint, additional spot radiographs shall be taken at what
increment?
Submitted
a) One radiograph shall be taken in each additional 200 feet
Correct
a) One radiograph shall be taken in each additional 200 feet
Q 91. What is the minimum weld length that must be clearly shown on
each radiograph?
Submitted
a) 2 inches
b) 3 inches
c) 6 inches
d) 8 inches
Correct
a) 2 inches
b) 3 inches
c) 6 inches
d) 8 inches
Answer is
Submitted
a) For double-welded butt joints, one spot radiograph shall be taken on 10 % of the radial joints
b) For single-welded butt joints with permanent or removable back-up bar, one spot radiograph
c) Full radiography.
d) only a & b.
Correct
a) For double-welded butt joints, one spot radiograph shall be taken on 10 % of the radial joints
b) For single-welded butt joints with permanent or removable back-up bar, one spot radiograph
c) Full radiography.
d) only a & b. Answer is
Submitted
a) Paragraph UW-51(b) in Section VIII of the ASME Code
Correct
a) Paragraph UW-51(b) in Section VIII of the ASME Code
Submitted
a) One additional spot shall be taken and at least 3” of weld shall be
c) Two spots ten feet from each side of the original radiography shall be examined
d) Two spots, chosen randomly by the purchaser’s inspector, shall be examined by radiography
Correct
a) One additional spot shall be taken and at least 3” of weld shall be
c) Two spots ten feet from each side of the original radiography shall be examined
d) Two spots, chosen randomly by the purchaser’s inspector, shall be examined by radiography
Answer is
Submitted
a) They shall become the property of the insurance company
Correct
a) They shall become the property of the insurance company
Correct
a) The magnetic particle written procedure at a distance not less than 12 inches
Submitted
a) 1/32 inch.
b) 3/32 inch
c) 1/8 inch.
d) 1/16 inch
Correct
a) 1/32 inch.
b) 3/32 inch
c) 1/8 inch.
Submitted
a) ASME VIII DIV.1
d) Same as radiography.
Correct
a) ASME VIII DIV.1
d) Same as radiography.
Answer is
Q 99. Undercutting of vertical butt joints, vertically oriented permanent
Attachments, attachment welds for nozzles, manholes, flush-type
openings, and the inside shell-to-bottom welds?
Submitted
a) Shall not exceed 1/64th inch
Correct
a) Shall not exceed 1/64th inch
Submitted
a. Not acceptable in visual examination.
b. Cracks are not acceptable but arc strikes are acceptable in visual examination
Correct
a. Not acceptable in visual examination.
b. Cracks are not acceptable but arc strikes are acceptable in visual examination
b. 3/16 inch.
c. 1/16 inch.
d. 3/32 inch.
Correct
a. 1/8 inch
b. 3/16 inch.
c. 1/16 inch.
d. 3/32 inch.
Answer is
Q 102.What are the dimensions of a standard vacuum testing box?
Submitted
a. 6” wide by 30” long
Correct
a. 6” wide by 30” long
Q 103.In an examination of a tank’s bottom weld seams by vacuum box
testing, what is the required partial vacuum pressure?
Submitted
a) At least 1 lbf/in2 gauge (psig)
Correct
a) At least 1 lbf/in2 gauge (psig)
Q 104.The vacuum-box test shall have at least ____ overlap of previously
viewed surface on each application.
Submitted
a. 3 inches
b. 2 inches
c. 1 inch
d. No overlap.
Correct
a. 3 inches
b. 2 inches
c. 1 inch
d. No overlap.
Answer is
Submitted
a. 40 to 125 deg.F.
b. 50 to 125 deg.F.
c. 60 to 125 deg.F.
d. 40 to 100 deg.F.
Correct
a. 40 to 125 deg.F.
b. 50 to 125 deg.F.
c. 60 to 125 deg.F.
d. 40 to 100 deg.F.
Answer is
d. The purchaser
Correct
a. The Manufacturer
d. The purchaser
Answer is
Q 107.Where tracer gas testing is employed as an alternate to vacuum-
box testing The technique shall be capable of detecting leakage of:
Submitted
a. 1x 10ˉ⁴Pa m³ /s
b. 2x 10ˉ⁴Pa m³ /s
c. 3x 10ˉ⁴Pa m³ /s
d. 5x 10ˉ⁴Pa m³ /s
Correct
a. 1x 10ˉ⁴Pa m³ /s
b. 2x 10ˉ⁴Pa m³ /s
c. 3x 10ˉ⁴Pa m³ /s
d. 5x 10ˉ⁴Pa m³ /s Answer is
Q 108.What welding process is not permitted when impact testing of the
material is required?
Submitted
a) Shielded metal-arc
b) Gas metal-arc
c) Oxyfuel
d) Submerged arc
Correct
a) Shielded metal-arc
b) Gas metal-arc
c) Oxyfuel
d) Submerged arc
Answer is
Submitted
a) Section VIII, Division 1
b) B31.3
c) Section VIII, Division 2
d) Section IX
Correct
a) Section VIII, Division 1
b) B31.3
d) Section IX
Answer is
Submitted
a) Surface temperature is below 0ºF.
Correct
a) Surface temperature is below 0ºF.
Q 111.When base metal thickness is 1.25 inches and material is group IV ,
what requirement must be met?
Submitted
a) The base metal within 3 inches of the starting point of the welding shall be heated to a
temperature of 50ºF
b) The base metal within 3 inches of the starting point of the welding shall be heated to a
c) The base metal within 3 inches of the starting point of the welding shall be heated to a
d) The base metal within 3 inches of the starting point of the welding shall be heated to a
Correct
a) The base metal within 3 inches of the starting point of the welding shall be heated to a
temperature of 50ºF
b) The base metal within 3 inches of the starting point of the welding shall be heated to a
c) The base metal within 3 inches of the starting point of the welding shall be heated to a
d) The base metal within 3 inches of the starting point of the welding shall be heated to a
Q 112.When tack welds are used during the assembly of vertical joints,
what requirement is stipulated by API-650?
Submitted
a) Tack welds that are to be removed do not require a qualified procedure or welder
b) Tack welds that are to be left in place shall be made using a qualified procedure only
c) Tack welds that are to be removed may be made using a welder in training
d) Tack welds that are to be left in place shall be made using a qualified procedure and welder
Correct
a) Tack welds that are to be removed do not require a qualified procedure or welder
b) Tack welds that are to be left in place shall be made using a qualified procedure only
c) Tack welds that are to be removed may be made using a welder in training
d) Tack welds that are to be left in place shall be made using a qualified procedure and welder
Answer is
Submitted
a) Nozzle reinforcement periphery welds
b) Shell-to-bottom weld
Correct
a) Nozzle reinforcement periphery welds
b) Shell-to-bottom weld
Correct
a) Maximum misalignment is 0 .150 inch
Q 115.In a horizontal joint of an AST, what is the maximum projection of
an upper plate beyond the face of the plate below it? The plate
thickness is 0.25 inch.
Submitted
a) Maximum projection is 0.0625 inch
Correct
a) Maximum projection is 0.0625 inch
b) Maximum projection is 0.0500 inch
Q 116.Multi-pass weld procedures are required for circumferential and
vertical joints in tank shell courses constructed of material that is
more than 1.5 inches thick. What is the maximum weld pass size
permitted?
Submitted
a) 1½ inches
b) ½ inches
c) ¼ inches
Correct
a) 1½ inches
b) ½ inches
c) ¼ inches
Q 117.The initial weld pass inside the shell of the shell-to-bottom weld
shall be cleaned and examined for its entire circumference. This
examination shall be visually and by which of the following?
Submitted
a) Magnetic particle or ultrasonic or suitable liquid penetrant process
b) Magnetic particle or suitable liquid penetrant process or a vacuum box and bubble method
Correct
a) Magnetic particle or ultrasonic or suitable liquid penetrant process
b) Magnetic particle or suitable liquid penetrant process or a vacuum box and bubble method
Submitted
a) Examine either side of the finished weld by MT, PT, or right angle vacuum box
c) Visually examine the finished joint welded surfaces (inside and outside the shell)
Correct
a) Examine either side of the finished weld by MT, PT, or right angle vacuum box
Submitted
a) A hydrostatic pressure test at up to 15 lbf/in2 (psig)
Correct
a) A hydrostatic pressure test at up to 15 lbf/in2 (psig)
Submitted
a) To the maximum design liquid level
b) Tanks with tight roofs, to 2 inches above the weld connecting the roof plate of compression
Correct
a) To the maximum design liquid level
b) Tanks with tight roofs, to 2 inches above the weld connecting the roof plate of compression
Submitted
a) The water level shall be not more than 31 feet from the bottom of the tank
b) The water level shall be not more than 32 feet from the bottom of the tank
Correct
a) The water level shall be not more than 31 feet from the bottom of the tank
b) The water level shall be not more than 32 feet from the bottom of the tank
c) The water level shall be at the maximum design liquid level
Submitted
a) 2.94 inches
b) 3.27 inches
c) 1.31 inches
d) 1.18 inches
Correct
a) 2.94 inches
b) 3.27 inches
c) 1.31 inches
d) 1.18 inches
Answer is
Submitted
a) ¾” measured 10 feet above the bottom corner weld
Correct
a) ¾” measured 10 feet above the bottom corner weld
Q 124.Peaking at vertical welds and banding at horizontal welds shall not
exceed ____.
Submitted
a) 1 inch
b) ¾ inch
c) ½ inch
d) ¼ inch
Correct
a) 1 inch
b) ¾ inch
c) ½ inch
d) ¼ inch
Answer is
Q 125.Peaking and banding are determined using a horizontal sweep
board for peaking and a straight edge vertical sweep board for
banding. What is the required length of these sweep boards?
Submitted
a) 48 inches
b) 24 inches
c) 42 inches
d) 36 inches
Correct
a) 48 inches
b) 24 inches
c) 42 inches
d) 36 inches
Answer is
Q 126.The top of the concrete ringwall (where installed) of an AST must
be level within ± 1/8” in any 30 feet of circumference. What is the
total circumferential tolerance measured from the average
elevation?
Submitted
a) ±1/8”
b) ±3/16”
c) ±1/2”
d) 1/4”
Correct
a) ±1/8”
b) ±3/16”
c) ±1/2”
d) 1/4”
Answer is
Submitted
a) ±1/8” in any 30’ of the circumference and ±1/2” in the total circumference measured from the
average elevation
b) ±1/8” in any 10’ of the circumference and ±1/2” in the total circumference measured from the
average elevation
c) ±1/8” in any 10’ of the circumference and ±1/4” in the total circumference measured from the
average elevation
d) ±1/8” in any 30’ of the circumference and ±1/4” in the total circumference measured from the
average elevation
Correct
a) ±1/8” in any 30’ of the circumference and ±1/2” in the total circumference measured from the
average elevation
b) ±1/8” in any 10’ of the circumference and ±1/2” in the total circumference measured from the
average elevation
c) ±1/8” in any 10’ of the circumference and ±1/4” in the total circumference measured from the
average elevation
d) ±1/8” in any 30’ of the circumference and ±1/4” in the total circumference measured from the
Submitted
a) ±1/8” in any 30’ of the circumference and ±1/4” in the total circumference measured from the
average elevation
b) ±1/8” in any 10’ of the circumference and ±1/2” in the total circumference
c) ±1/8” in any 10’ of the circumference and ±1/4” in the total circumference measured from the
average elevation
d) ±1/4” in any 30’ of the circumference and ±1/4” in the total circumference
Correct
a) ±1/8” in any 30’ of the circumference and ±1/4” in the total circumference measured from the
average elevation
b) ±1/8” in any 10’ of the circumference and ±1/2” in the total circumference
c) ±1/8” in any 10’ of the circumference and ±1/4” in the total circumference measured from the
average elevation
d) ±1/4” in any 30’ of the circumference and ±1/4” in the total circumference
Answer is
Q 129.What is the water filling rate allowed for below top course of 6/8
inch thick bottom course storage tank?
Submitted
a) 9 inch per hour..
Correct
a) 9 inch per hour..
Submitted
a. Where the plates are thicker than 1/2 inch (based on the thickness of the thicker member
b. For all thicknesses when the plates are made of material from Groups IV, IVA, V, and VI.
d. Only a &b
Correct
a. Where the plates are thicker than 1/2 inch (based on the thickness of the thicker member
b. For all thicknesses when the plates are made of material from Groups IV, IVA, V, and VI.
Q 131.What should be the dwell time for penetrant leak testing of shell to
bottom welds?
Submitted
a. 5 minutes minimum.
b. 10 minutes minimum.
c. 60 minutes minimum.
d. 45 minutes minimum.
Correct
a. 5 minutes minimum.
b. 10 minutes minimum.
c. 60 minutes minimum.
d. 45 minutes minimum.
Answer is
Correct
a. 6 inches on both sides of repaired area.
Q 133.When testing tank bottom by pumping water underneath bottom
what should be the liquid head to be maintained?
Submitted
a. 12 inch.
b. 6 inch.
c. 3 inch.
d. 4 inch.
Correct
a. 12 inch.
b. 6 inch.
c. 3 inch.
d. 4 inch. Answer is
Q 134.If sufficient water to fill the tank is not available and hydrostatic
test exemption is specified by the Purchaser which of the following
is the requirement?
Submitted
a. All tank shell weld intersections where vertical joints meet horizontal joints shall be
Correct
a. All tank shell weld intersections where vertical joints meet horizontal joints shall be
Submitted
a. Attachments to the shell located at least 3 feet above the water level.
b. Roof appurtenances.
c. All Nonstructural small attachments.
d. Only a & b
Correct
a. Attachments to the shell located at least 3 feet above the water level.
b. Roof appurtenances.
d. Only a & b
Answer is
Submitted
a. Adding an oxygen scavenger.
b. Adding a biocide.
Correct
a. Adding an oxygen scavenger.
b. Adding a biocide.
Answer is
Q 137.What is the maximum spacing allowed between shell elevation
measurements?
Submitted
a. 32 feet.
b. 32 inches.
c. 10 feet.
d. 32 meter.
Correct
a. 32 feet.
b. 32 inches.
c. 10 feet.
d. 32 meter.
Answer is
Q 138.If settlement measurements are specified by the Purchaser, any
differential settlement greater than ____ of circumference or a
uniform settlement over ____ shall be reported to the Purchaser for
evaluation.
Submitted
a. 1/2 inch per 32 feet and 2 inch.
Submitted
a) May be installed by welders who need practice
c) Are not considered as having any strength value in the finished structure
d) Have strength value in the finished structure provided they are performed by a qualified
Correct
a) May be installed by welders who need practice
c) Are not considered as having any strength value in the finished structure
d) Have strength value in the finished structure provided they are performed by a qualified
b) 1/4”
c) 3/8”
d) 1/2”
Correct
a) 3/16”
b) 1/4”
c) 3/8”
d) 1/2”
Answer is
Q 141.For lap-welded joints that are tack welded, what is the minimum
amount of lap permitted?
Submitted
a) The lap need not exceed 2”
c) The joint shall be lapped at least 5 times the minimum required thickness of the thinner plate
d) The joint shall be lapped at least 5 times the nominal thickness of the thinner plate
Correct
a) The lap need not exceed 2”
b) The lap need not exceed 1”
c) The joint shall be lapped at least 5 times the minimum required thickness of the thinner plate
d) The joint shall be lapped at least 5 times the nominal thickness of the thinner plate Answer is
Q 142.A fillet weld whose size is equal to the thickness of the thinner
joined member is:
Submitted
a. Full fillet weld.
Correct
a. Full fillet weld.
Submitted
a. For Groups I, II, III, and IIIA materials manual welding processes, fillet weld legs or groove weld
b. For Groups I, II, III, and IIIA materials for semi-automatic, machine, and automatic welding
processes, fillet weld legs or groove weld depths greater than 10 mm (3/8 in.) shall be multipass.
c. For Groups IV, IVA, V, or VI shell-to-bottom welds for all welding processes, all welds shall be
made using a minimum of two passes.
Correct
a. For Groups I, II, III, and IIIA materials manual welding processes, fillet weld legs or groove weld
b. For Groups I, II, III, and IIIA materials for semi-automatic, machine, and automatic welding
processes, fillet weld legs or groove weld depths greater than 10 mm (3/8 in.) shall be multipass.
c. For Groups IV, IVA, V, or VI shell-to-bottom welds for all welding processes, all welds shall be
made using a minimum of two passes.
Submitted
a) The minimum offset shall be 5 times the second shell course height
b) The minimum offset shall be 5 times the thickness of the second course
c) The minimum offset shall be 5 times the first shell course height
d) The minimum offset shall be 5 times the thickness of the first shell course
Correct
a) The minimum offset shall be 5 times the second shell course height
b) The minimum offset shall be 5 times the thickness of the second course
c) The minimum offset shall be 5 times the first shell course height
d) The minimum offset shall be 5 times the thickness of the first shell course
Answer is
Submitted
a) 1.2 inches
b) 12 inches
c) 1.2 feet
d) 12 feet
Correct
a) 1.2 inches
b) 12 inches
c) 1.2 feet
d) 12 feet
Answer is
Q 146.What is the maximum size of fillet weld permitted in the
attachment between the lowest course shell plate and the bottom
plate?
Submitted
a) 3/8 inch
b) 5/16 inch
c) 1/2 inch
d) 1/4 inch
Correct
a) 3/8 inch
b) 5/16 inch
c) 1/2 inch
d) 1/4 inch
Answer is
Q 147.What is the minimum size fillet weld required on each side of the
shell plate attaching shell plate to the annular plate? The shell plate
is 1.25” thick.
Submitted
a) 3/8 inch
b) 3/16 inch
c) 1/4 inch
d) 5/16 inch
Correct
a) 3/8 inch
b) 3/16 inch
c) 1/4 inch
d) 5/16 inch
Answer is
Q 148.A 110 ft diameter tank shall have a top angle not less than ____
inches.
Submitted
a) 2 X 2 X 3/8
b) 2 X 3 X 3/8
c) 3 X 3 X 3/8
d) 3 X 2 X 3/8
Correct
a) 2 X 2 X 3/8
b) 2 X 3 X 3/8
c) 3 X 3 X 3/8
d) 3 X 2 X 3/8
Answer is
Q 149.How many hardness tests are required on vertical joints of group
IV to VI materials when specified by purchaser?
Submitted
a. One on each vertical weld.
Correct
a. One on each vertical weld.
Q 150.According to API-650, tanks meeting the minimum requirements
of the standard may be subjected to a partial vacuum of _____.
Submitted
a) One inch of mercury
Q 151.An AST is 116 ft in diameter and constructed of A 516-70 Group V
as rolled material. How many hardness tests are required on one
circumferential weld?
Submitted
a) One
b) Two
c) Three
d) Four
Correct
a) One
b) Two
c) Three
d) Four
Answer is
Q 152.The purchaser orders an aboveground storage tank and insists on a
corrosion allowance in the bottom plates of 0.125 inches. What is
the minimum thickness permitted for bottom plates in this tank?
Submitted
a) Minimum thickness of bottom plate is 1/4 inch
Correct
a) Minimum thickness of bottom plate is 1/4 inch
Submitted
a) Minimum projection is 0.01 inch
Correct
a) Minimum projection is 0.01 inch
b) Minimum projection is 0.10 inch
Q 154.Annular bottom plates shall have a radial width that provides at
least ____ between the inside of the shell and any lap-welded joint
in the remainder of the bottom.
Submitted
a) 12 inches
b) 24 inches
c) 1.2 inches
d) 2.4 inches
Correct
a) 12 inches
b) 24 inches
c) 1.2 inches
d) 2.4 inches
Answer is
Q 155.How far must annular bottom plates project outside the shell?
Submitted
a) Annular bottom plates shall project at least 1 inch when trimmed
b) Annular bottom plates shall project at least 3/4 inch beyond the edge of the weld
c) Annular bottom plates shall project greater of at least 2 inches outside the shell or ½ inch
d) Annular bottom plates shall project at least 5t (t = thickness of the shell course) outside the
shell
Correct
a) Annular bottom plates shall project at least 1 inch when trimmed
b) Annular bottom plates shall project at least 3/4 inch beyond the edge of the weld
c) Annular bottom plates shall project greater of at least 2 inches outside the shell or ½ inch
beyond the edge of weld.
d) Annular bottom plates shall project at least 5t (t = thickness of the shell course) outside the
shell
Answer is
Submitted
a) Minimum required thickness is 5/8th inch
Q 157.According to API-650, what is the minimum allowable nominal
shell thickness of an AST that is 86 feet in diameter?
Submitted
a) Minimum nominal shell thickness is 3/16th inch
Correct
a) Minimum nominal shell thickness is 3/16th inch
Q 158.Unless otherwise agreed to by the purchaser, what is the minimum
nominal width of shell plates?
Submitted
a) Minimum width of shell plates is 84 inches
Correct
a) Minimum width of shell plates is 84 inches
Q 159.For 100 feet diameter tank bottom what is the slope required
towards centre of bottom?
Submitted
a. 12 inches
b. 5 inches.
c. 6 inches.
d. 10 inches.
Correct
a. 12 inches
b. 5 inches.
c. 6 inches.
d. 10 inches. Answer is
Q 160.In calculating the net plate thickness for an AST fabricated of A
516 Grade 60 material, what would be the product design stress
value used in the calculation?
Submitted
a) 24,000
b) 21,300
c) 32,000
d) 23,300
Correct
a) 24,000
b) 21,300
c) 32,000
d) 23,300
Answer is
Q 161.The fabricator of an AST obtains the approval of the purchaser to
use the alternative shell design permitted in Appendix A in the
design of a 60 foot diameter tank using 3/8th inch A 516 Grade 60
plate. What allowable stress would be used in the design
calculations?
Submitted
a) 21,300
b) 24,000
c) 21,000
d) 32,000
Correct
a) 21,300
b) 24,000
c) 21,000
d) 32,000
Answer is
Q 162.What is the maximum diameter of tank that permits the 1-foot
method of calculation for required thickness?
Submitted
a) Tanks 50 feet in diameter and less
Correct
a) Tanks 50 feet in diameter and less
b) Tanks 120 feet in diameter and less
Q 163.Openings in tank shells, larger than that required to accommodate
a ____ flanged or threaded nozzle shall be reinforced.
Submitted
a) 2 inch
b) 2.5 inch
c) 3 inch
d) 3.5 inch
Correct
a) 2 inch
b) 2.5 inch
c) 3 inch
d) 3.5 inch
Answer is
Q 164.When installing openings in a shell plate of thickness greater than
½ inches the edge of the fillet weld around the periphery of the
reinforcing pad shall be spaced at least the greater of _______ from
the centerline of any butt-welded shell joints.( as welded no pwht)
Submitted
a) Eight inches or ten times the weld size
Correct
a) Eight inches or ten times the weld size
Submitted
a) Eight times the larger weld or ten inches from each other
b) Eight inches or six times the larger weld from each other
c) Eight times the larger weld or six inches from each other
d) Eight times the larger weld or eight inches from each other
Correct
a) Eight times the larger weld or ten inches from each other
b) Eight inches or six times the larger weld from each other
c) Eight times the larger weld or six inches from each other
d) Eight times the larger weld or eight inches from each other Answer is
Q 166.A minimum distance of ____ shall be maintained between the toe of
a weld around a non-reinforced penetration and the toe of the
shell-to bottom weld for shell thickness less than 0.5 inch.
Submitted
a) Ten inches
b) Eight inches
c) Six inches
d) Three inches
Correct
a) Ten inches
b) Eight inches
c) Six inches
d) Three inches
Answer is
b) Minimum spacing dimensions are met and a radiographic examination of the welded joint is
conducted
c) Minimum spacing dimensions are met and an ultrasonic examination of the welded joint is
conducted
d) Minimum spacing dimensions are met and a magnetic particle examination of the welded joint
is conducted
Correct
a) Minimum spacing dimensions are met and a liquid penetrant examination of the welded joint
is conducted
b) Minimum spacing dimensions are met and a radiographic examination of the welded joint is
conducted
c) Minimum spacing dimensions are met and an ultrasonic examination of the welded joint is
conducted
d) Minimum spacing dimensions are met and a magnetic particle examination of the welded joint
is conducted
Answer is
Submitted
a) 1100°F to 1200°F for 1 hour per inch of reinforcing plate thickness
b) 1100°F to 1200°F for 1/2 hour per inch of shell thickness
d) 1100°F to 1200°F for 1 & 1/2 hour per inch of shell thickness
Correct
a) 1100°F to 1200°F for 1 hour per inch of reinforcing plate thickness
d) 1100°F to 1200°F for 1 & 1/2 hour per inch of shell thickness
Answer is
Submitted
a) The shell plate is first pre-heated to 300°F
Correct
a) The shell plate is first pre-heated to 300°F
Submitted
a) Minimum thickness of cover plate is 9/16th inch
Correct
a) Minimum thickness of cover plate is 9/16th inch
Q 171.What is the bolt circle diameter for a cover plate used with a 30
inch diameter manhole?
Submitted
a) 32 ¾ inch
b) 36 ¼ inch
c) 38 ¾ inch
d) 42 ¼ inch
Correct
a) 32 ¾ inch
b) 36 ¼ inch
c) 38 ¾ inch
d) 42 ¼ inch
Answer is
Q 172.The purchaser has ordered a 36 inch manhole to be installed in the
first course of an AST. The thickness of the shell plate and the
reinforcing plate is 1.375 inches. What is the required hole
diameter that must be cut in the tank to accommodate this
manhole?
Submitted
a) 36 & 1/4 inch
Correct
a) 36 & 1/4 inch
Q 173.The drip ring shall extend at least ___ beyond the outer periphery of
the foundation ringwall and then turn down (up to 90°) at its outer
diameter:
Submitted
a. 4 inches.
b. 3 inches
c. 6 inches
d. 12 inches
Correct
a. 4 inches.
b. 3 inches
c. 6 inches
d. 12 inches
Answer is
Q 174.Which of the following are considered as permanent attachments?
Submitted
a. Wind girders.
b. Gauging systems.
c. Walkways.
Correct
a. Wind girders.
b. Gauging systems.
c. Walkways.
Q 175.What is the maximum size opening that may be placed in a cover
plate?
Submitted
a) 12 inches pipe size
Correct
a) 12 inches pipe size
Answer is
Q 176.What should be the minimum distance between permanent
attachment and horizontal and vertical joints ?
Submitted
a) 6 inches and 3 inches.
Correct
a) 6 inches and 3 inches.
Submitted
a) 3 inches.
d) 12 inches
Correct
a) 3 inches.
d) 12 inches
Answer is
Submitted
a) 6 times the shell thickness or ½ the radius of opening whichever is less
c) 6 inches.
Correct
a) 6 times the shell thickness or ½ the radius of opening whichever is less
c) 6 inches.
Submitted
a) 30 deg.
b) 1:12
c) 1:2
d) 1:4
Correct
a) 30 deg.
b) 1:12
c) 1:2
d) 1:4
Answer is
Q 180.All free vents shall be provided with corrosion-resistant coarse-
mesh bird screens of a maximum opening size of ?
Submitted
a) ¼ inch.
b) 1.0 inch
c) ¾ inch.
d) ½ inch
Correct
a) ¼ inch.
b) 1.0 inch
c) ¾ inch.
d) ½ inch Answer is
Submitted
a) 3 feet x 6 feet.
b) 3 feet x 3 feet.
c) 6 feet x 6 feet.
Correct
a) 3 feet x 6 feet.
b) 3 feet x 3 feet.
c) 6 feet x 6 feet.
Q 182.If a material tensile strength is 70,000 psi and yield strength is
38,000 psi what should be the design stress used for shell
thickness calculation?
Submitted
a. 25,000 psi.
b. 25,300 psi.
c. 23,30.0 psi.
d. 28,000 psi
Correct
a. 25,000 psi.
b. 25,300 psi.
c. 23,30.0 psi.
d. 28,000 psi
Answer is
Q 183.What is the minimum nominal thickness permitted for roof plates?
Submitted
a) 3/16 inch or 5.76 pounds per square foot
Correct
a) 3/16 inch or 5.76 pounds per square foot
Q 184.As per API Standard 650, the overlap at lap-welded joints shall be
at least five times the nominal thickness of the thinner plate, but
need not exceed,
Submitted
a) 2” for single-welded lap joints and 4” for double welded lap joints
b) 1” for single-welded lap joints and 2” for double welded lap joints
c) 1.5” for single-welded lap joints and 2” for double welded lap joints
d) 1.5” for single-welded lap joints and 1” for double welded lap joints
Correct
a) 2” for single-welded lap joints and 4” for double welded lap joints
b) 1” for single-welded lap joints and 2” for double welded lap joints
c) 1.5” for single-welded lap joints and 2” for double welded lap joints
d) 1.5” for single-welded lap joints and 1” for double welded lap joints
Answer is
b) 0.968”
c) 1.2”
d) 0.922
Correct
a) 1.068”
b) 0.968”
c) 1.2”
d) 0.922
Answer is
Q 186.Calculate by the 1-Foot method the hydrostatic test shell thickness
Tt in inches, of the above referred tank, when water is used for the
test :
Submitted
a) 0.935”
b) 0.985”
c)1.200”
d) 0.955”
Correct
a) 0.935”
b) 0.985”
c)1.200”
d) 0.955” Answer is
Q 187.The minimum required shell thickness of a Tank of 200 ft. diameter
built to API Standard 650, shall be:
Submitted
a) Design shell thickness plus corrosion allowance
c) 8 mm (5/16”)
d) Greater of a, b, c
Correct
a) Design shell thickness plus corrosion allowance
c) 8 mm (5/16”)
d) Greater of a, b, c
Answer is
Q 188.For 36” diameter draw off sump what should be the distance from
centre pipe to shell?
Submitted
a) 3.5 feet
b) 5.0 feet
c) 6.75 feet.
Correct
a) 3.5 feet
b) 5.0 feet
c) 6.75 feet.
Q 189.What should be the roof rafter spacing for roof thickness 0.5”,plate
yield strength 21,000 psi and pressure 2 psi?
Submitted
a) 18 inches
b) 15 inches
c) 62 inches
d) 80 inches.
Correct
a) 18 inches
b) 15 inches
c) 62 inches
d) 80 inches. Answer is
Q 190.A roof is considered ____ if the roof to shell joint will fail prior to the
shell-to-bottom joint in the event of excessive internal pressure:
Submitted
a) External floating
b) Internal floating.
c) Fixed.
d) frangible
Correct
a) External floating
b) Internal floating.
c) Fixed.
d) frangible
Answer is
Submitted
a) is formed approximately to the surface of a right cone;
b) both a and d
Correct
a) is formed approximately to the surface of a right cone;
b) both a and d
Submitted
a) made with at least 2 passes
Correct
a) made with at least 2 passes
Correct
a) is formed approximately to the surface of a right cone;
Q 194.The weight of the tank or tank component, including any corrosion
allowance is called as:
Submitted
a) Live load
b) Dead load
c) Fixed load
Correct
a) Live load
b) Dead load
c) Fixed load
Q 195.If frangible roof radius is 72 feet what should be the slope from top
angle?
Submitted
a) 12 feet
b) 8 feet
c) 6 feet
d) 8 inches
Correct
a) 12 feet
b) 8 feet
c) 6 feet
d) 8 inches
Answer is
Submitted
a) ¼ inch
b) ½ inch
c) 1 inch.
d) ¾ inch.
Correct
a) ¼ inch
b) ½ inch
c) 1 inch.
d) ¾ inch.
Answer is