Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

BW30Pro-400

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Product Data Sheet

FilmTec™ Reverse Osmosis Membranes

FilmTec™ BW30 PRO-400


High Rejection and High Performance Industry-Standard Brackish Water Reverse
Osmosis Membrane Element

Key Features Key Applications


l Delivers consistent water quality and higher rejection and l Demineralization for industrial applications, such as: Power
flow than previous generation BW30 product Generation, Steel & Metal, Chemical & Petrochemical
l Based on historical BW30 Industry-standard RO membrane l Municipal water purification
with decades of proven performance
l Outstanding durability resulting in stable, long-term
performance

Typical Properties
Active Area Feed Spacer Thickness Permeate Flow Rate Stabilized Salt Rejection Minimum Salt Rejection
FilmTec™ Element ft2 (m2) (mil) gpd (m3/d) (%) (%)
BW30 PRO-400 400 (37) 28 11,000 (42) 99.6 99.4
1. Permeate flow and salt rejection based on the following standard conditions: 2,000 ppm NaCl, 225 psi (15.5 bar), 77°F (25°C), pH 8 and 15% recovery.
2. Flow rates for individual elements may vary but will be no more than 15% below the value shown.
3. Sales specifications may vary as design revisions take place.

Element Dimensions

FilmTec™ Element BW30 PRO-400


Dimensions – inches (mm)
A 40.0 (1,016)
B 1.125 ID (29)
C 7.9 (201)

1. For element weight information refer to the FAQ.


2. For element packaging and shipping information refer to How are FilmTec™ elements packaged and shipped?
Suggested Operating Conditions

Membrane Type Polyamide Thin-Film Composite 1. Maximum temperature for continuous operation above pH 10
is 95°F (35°C).
Maximum Operating Temperature 1 113°F (45°C)
2. Refer to FilmTec™ Cleaning Guidelines
Maximum Operating Pressure 600 psig (41 bar) (Form No. 45-D01696-en).
Maximum Pressure Drop 3. For recommended feed and permeate flow rates, flux, and
recovery for various feed sources, refer to FilmTec™ Design
Per Element 15 psig (1.0 bar) Guidelines for multiple-element systems of 8-inch elements
Per Pressure Vessel (Minimum 4 Elements) 50 psig (3.5 bar) (Form No. 45-D01695-en).
pH Range 4. Oxidation damage is not covered under warranty, DuPont
1
recommends removing residual free chlorine by pretreatment
Continuous Operation 2 - 11 prior to membrane exposure. Please refer to Dechlorinating
Short-Term Cleaning (30 min.) 2 1 - 13 Feedwater (Form No. 45-D01569-en) for more information.
Maximum Feed Flow 3 75 gpm (17 m3/hr)
Maximum Feed Silt Density Index SDI 5
Free Chlorine Tolerance 4 < 0.1 ppm

General Information Important Information


l Keep elements moist at all times after initial wetting. Please consider good operating practices for the optimal
l If operating limits and guidelines given in this bulletin are not performance of the Reverse Osmosis membrane elements to
strictly followed, the FilmTec™ Reverse Osmosis and assure damage free operation:
Nanofiltration Three-Year Prorated Limited Warranty 1. Loading of Pressure Vessels - Preparation & Element Loading
(Form No. 45-D00903-en) will be null and void. (Form No. 45-D01602-en)
l To prevent biological growth during prolonged system 2. System Operation, including plant Start-Up Sequence
shutdowns, it is recommended that membrane elements be (Form No. 45-D01609-en) and RO & NF Systems Shutdown
immersed in a preservative solution. (Form No. 45-D01613-en)
l The customer is fully responsible for the effects of 3. Storage and Shipping of New FilmTec™ Elements
incompatible chemicals and lubricants on elements. (Form No. 45-D03716-en)
l Avoid static permeate-side backpressure at all times.
l Permeate obtained from the first hour of operation should be Regulatory Note
discarded.
l The use of this product in and of itself does not necessarily This product may be subject to drinking water application
guarantee the removal of cysts and pathogens from water. restrictions in some countries; please check the application status
Effective cyst and pathogen reduction is dependent on the before use and sale.
complete system design and on the operation and
maintenance of the system.

All information set forth herein is for informational purposes only. This information is general information and may differ from that based on actual conditions. Customer
is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's workplace
and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale
and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries. Please note that physical
properties may vary depending on certain conditions and while operating conditions stated in this document are intended to lengthen product lifespan and/or improve
product performance, it will ultimately depend on actual circumstances and is in no event a guarantee of achieving any specific results. DuPont assumes no obligation
or liability for the information in this document. References to “DuPont” or the “Company” mean the DuPont legal entity selling the products to Customer unless
otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
ARE EXPRESSLY EXCLUDED. No freedom from infringement of any patent or trademark owned by DuPont or others is to be inferred.

Have a question? Contact us at: © 2021 DuPont. DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with ™, ℠ or ® Form No . 45-D03742-en, Rev. 0
www.dupont.com/water/contact-us are owned by affiliates of DuPont de Nemours Inc., unless otherwise noted. October 2021