Aprilaire 5000 Installation Manual
Aprilaire 5000 Installation Manual
Aprilaire 5000 Installation Manual
MODEL 5000
TABLE OF CONTENTS
Safety Instructions ...........................................................................................................2
Specifications......................................................................................................................2
Components........................................................................................................................3
Installation ............................................................................................................................4
Operating Instructions....................................................................................................6
SAFETY INSTRUCTIONS
Read the safety and installation instructions carefully. They will help ensure a correct and SAFE installation of the Aprilaire Electronic Air Cleaner.
WARNING:
120 Volts may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. Leave power disconnected until installation is completed. Arcing in electrical components may cause an explosion. Do not install unit where explosive gasses will be present. Sharp edges may cause injury from cuts. Use care when cutting and handling sheet metal. To reduce the risk of electrical shock, this equipment has a grounding-type (three prong) plug. This plug will fit only into a grounding-type power outlet. If the plug does not fit into the outlet, contact qualified personnel to install the proper outlet. Do not alter this plug in any way. To reduce the risk of electrical shock, locate product so that the power cord can be plugged into an electrical outlet without the use of an extension cord.
CAUTION:
To prevent component failure, do not install the air cleaner on the warm air supply or in an area where the temperature may exceed 149 F. This may include areas above heat exchangers in downflow furnaces or above exhaust flues in lowboy furnace cold air returns. The air cleaner must be installed where the ambient air temperature remains between 32 F and 149 F [0 C and 65 C]. Installation must conform to all applicable codes. Do not install an atomizing humidifier upstream of the air cleaner. Water or mist will cause power supply to shut down.
SPECIFICATIONS
Description The Aprilaire Electronic Air Cleaner Model 5000 is an electronically enhanced ElectraMedia air cleaner. Overall Unit 17 3 / 4 " x 31 1 / 8 " x 11 1 / 2 " 2000 cfm maximum 120V AC 15%, 50/60 Hz Nom., Unit equipped with a 5 ft. grounded cord with plug. Less than 50 watts with high voltage active. 35 lbs.
Power Usage
Shipping Weight
COMPONENTS
MODEL 5000
Figure 1
PLEAT SPACERS
OUTER HOUSING
#501 MEDIA
INNER HOUSING
CONTROL ELECTRODE
Handle
IONIZER FRAME
Model 51
INSTALLATION Important
The Model 5000 Air Cleaner is designed for systems with airflow up to 2000 cfm. If the furnace has more than one return air inlet connection, install one air cleaner in each. The air cleaner can be installed horizontally, vertically, or at an angle depending on furnace type. Figures 2, 3, and 4 show unit orientation in various types of applications. Note airflow direction arrows on inner assembly and outer housing. Allow 29 clearance in front of the unit for media replacement (see Figure 5). If a transition or offsets are required, minimize transition angles to reduce system pressure drop (see Figure 4). Figure 6 shows the air cleaner dimensions.
Figure 3
Figure 4
Upflow "Highboy" - Side Return Installations Airflow
Horizontal Installation
Figure 2
Upflow "Highboy" - Closet Installation (Bottom Return) Airflow Airflow
Figure 5
Figure 5
Figure 6
281/8" without door 237/8" 14 3/4"
door
Front
CAUTION: Do not install an atomizing humidifier upstream from the air cleaner.
INSTALLATION PROCEDURE
Warning: 120 Volts may cause serious injury from electrical shock. Leave power disconnected until installation is completed. 1. Remove air cleaner power pack /door assembly and pull inner assembly out of the outer housing. 2. Remove media carton from the inner housing. 3. Turn off furnace/air handler. 4. On retrofit applications, remove existing filter, discard it, and thoroughly clean the blower and blower compartment. 5. With airflow label in proper orientation, attach outer housing to furnace/air handler system. Seal inlet and discharge connections with caulk or mastic and provide support for the housing as required (See Figure 7). See Figures 2 through 4 for typical system types. 6. Install the media using the instructions on the media carton. 7. Check to make sure that the ionizer frame is properly inserted into the inner housing and that the control electrode is inserted fully into the ionizer frame. 8. Insert the inner assembly into the outer housing and replace the door. 9. Press the power cord into the slot in the side of the power pack /door assembly so that it is directed towards the outlet. See Figure 8. 10. Install a single outlet receptacle to the furnace/air handler cabinet which conforms to NEC standards as well as all applicable local codes, using 1 of the 2 options below: Figure 9- Use the furnace/air handler EAC terminals to wire the outlet. Figure 10- If EAC terminals are not available use the Model 51 (supplied) to wire the outlet and refer to the instructions provided with the Model 51. The outlet must only energize when the system blower is on. IMPORTANT: Identify the outlet for EAC USE ONLY 11. Return power to the furnace/air handler. 12. Plug the Aprilaire Air Cleaner power cord into the outlet installed in step 10. 13. Check for proper operation when the furnace is run through heating and cooling cycles. 14. Provide owners manual and warranty card to homeowner after explaining operation of unit.
Figure 7
Figure 8
Figure 9
Figure 10
OPERATING INSTRUCTIONS
The inner housing assembly must be installed and the power pack /door assembly to the air cleaner must be fully closed. The unit should be plugged in and the power switch on the air cleaner door turned on. There are no other controls or settings required. When the system blower turns on, the air cleaner will turn on and a green light located on the air cleaner door will turn on. After the system blower has turned off, the green light will turn off.
Figure 11
Bus Bar
Figure 5
Ionizer Wires
Control Electrode
If those conditions are met and the green light does not come on, the air cleaner circuit is not being activated. If the green light blinks at approximately one-minute intervals, the air cleaner circuitry is attempting to turn on, but is quickly turning off due to either an over-current condition or because arcing is occurring between components. Check the inner assembly as follows:
1. Turn the furnace/air handler blower off. 2. Turn the air cleaner off. 3. Unplug the air cleaner. 4. Open the power pack /door assembly. 5. Remove the inner housing assembly.
6. Inspect components to ensure the following: a. All components must be dry. b. The ionizer frame-grounding clip must be in contact with the pre-filter. See Figure 11.
Pleat Spacer
Figure 12
End Panel
6. Inspect components to ensure the following (continued): c. The conductive rubber strip must be in contact with the conductive-coated tips of the media. See Figure 12. d. The nine ionizing wires must be clean, straight, and hooked onto the bus bar at one end and the ionizer frame at the other. See Figure 11. e. The control electrode must be properly inserted in the ionizer frame. f. There must be no debris bridging the gap between the ionizing wires and any other component.
7. If a Model 51 is used: a. Measure the current for the wire under the bracket - this must be 4 amps or more. b. Ensure the Model 51 is at least 4 away from any transformer. 8. Re-install the inner housing assembly and close the power pack /door assembly. 9. Plug in the unit and turn it on. 10. Turn on the furnace/air handler blower. 11. After the blower starts, check unit for proper operation.
P.O. BOX 1467 MADISON, WI 53701-1467 Phone 608/257-8801 FAX 608/257-4357 Products For Better Indoor Air Quality
DP# 10004114 5.5.02