PP Emergencies
PP Emergencies
PP Emergencies
18 February 2013
PMI Revision 00
Presentation outline
Boiler Emergencies
Turbine Emergencies
Generator Emergencies
Grid Failure
18 February 2013
PMI Revision 00
BOILER
18 February 2013
PMI Revision 00
18 February 2013
PMI Revision 00
18 February 2013
PMI Revision 00
ID FAN TRIP
Motor over-loaded. Corresponding FD Fan has tripped. Spurious electrical fault. Lub. Oil pressure problem. Bearing temperature problem. Corresponding APH may have tripped.
18 February 2013
PMI Revision 00
18 February 2013
PMI Revision 00
FD FAN TRIPPED
Motor over-loaded Lub oil pressure trouble. Bearing temperature trouble. ID fan has tripped. FD lub. Oil pressure low.
18 February 2013
PMI Revision 00
PA FAN TRIPPED
tripping is due to high bearing temp. Boiler has tripped. Lub. Oil pressure may be very low. It will lead to tripping of some mills in service.
18 February 2013
PMI Revision 00
AIR PRE-HEATER
AIR PRE HEATER BEARING TEMPERATURE VERY HIGH. AIR PRE-HEATER ELECTRIC MOTOR TRIPPED. APH ELECTRIC DRIVE TRIPPED AND AIR MOTOR FAILS TO START. AIR PRE-HEATER ON FIRE.
18 February 2013
PMI Revision 00
10
18 February 2013
PMI Revision 00
11
18 February 2013
PMI Revision 00
12
18 February 2013
PMI Revision 00
13
18 February 2013
PMI Revision 00
14
18 February 2013
PMI Revision 00
15
18 February 2013
PMI Revision 00
16
18 February 2013
PMI Revision 00
17
18 February 2013
PMI Revision 00
18
TURBINE
18 February 2013
PMI Revision 00
19
TURBINE EMERGENCIES
SUDDEN LOAD THROW OFF SUDDEN INCREASE OF LOAD FROM FULL LOAD VIBRATION HIGH TURBINE OVER SPEED MOT LEVEL LOW TURBINE BEARING OIL PRESS LOW BEARING OIL INLET TEMP. HIGH DIFFERENTIAL EXPANSION HI/LOW AXIAL SHIFT HIGH LOSS OF VACUUM LOSS OF BARRING GEAR OR BARRING GEAR FAILS TO START
18 February 2013
PMI Revision 00
20
18 February 2013
PMI Revision 00
21
18 February 2013
PMI Revision 00
22
LOSS OF VACUUM
Steam ejector not properly functioning. High level in condenser LOSS OF CIRCULATING WATER PUMP Air leak into system Condenser tube choking CW inlet water temp hi.
18 February 2013
PMI Revision 00
23
18 February 2013
PMI Revision 00
24
GENERATOR
18 February 2013
PMI Revision 00
25
Generator emergencies
Stator Water Flow Low Stator Water Conductivity High Hydrogen Pressure Low/Hydrogen leakage Hydrogen Purity Low Seal Oil Differential pr low Liquid in Generator Generator Stator Cooling Water Leakage Damper Tank Level Low Rotor Temperature High Stator Winding Temperature High Loss of Excitation Generator Transformer Cooling System Trouble Generator Rotor Earth Fault.
18 February 2013
PMI Revision 00
26
GRID FAILURE
1.DC lighting ON ( Torch light must be available at least in night shift). 2. Ensure starting of emergency DC drives: -Gen Seal Oil pump. -LOP of main TG -Scanner air fan. Then monitor battery voltage and current. 3. Ensure starting of air motors of APHs. 4. Open vacuum breaker manually. Close MOT oil centrifuge supply vv. Close SB isolation vv. Close gland steam supply vv.
18 February 2013
PMI Revision 00
27
GRID FAILURE
5.Ensure starting of DG set ,charging of EMCC and then changing over of emergency drives. 6.Open the incomer breakers of switch gears and transformers (motor breakers tripped on no voltage ). 7.After normalization of EMCC TVDC,BVDC AND BDDC power supply will restore. So care must be taken so that condenser/FT etc. will not
18 February 2013
PMI Revision 00
28
MISCELLANEOUS SYSTEMS
LOSS OF STATION AIR PRESSURE. LOSS OF INSTRUMENT AIR PRESSURE. BOILER WATER SILICA HIGH. ELECTRICAL TRIPPING OF SUPPLY TO THE BOARD.
18 February 2013
PMI Revision 00
29
THANK YOU
18 February 2013
PMI Revision 00
30