Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (1 vote)
160 views31 pages

Transformer & Electrical Machines

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1/ 31

CHAPTER 6

Transformer & Electrical


Machines
TRANSFORMERS

 A transformer is an electrical device that transfers


energy from one circuit to another by magnetic coupling
with no moving parts.

 When two loops with or without contacts between them


affect each other through the magnetic field generated
by one of them they are said to be magnetically coupled.
TRANSFORMERS

 Transformers uses the magnetically coupled coils to


transfer energy from one circuit to another.

 Transformer is used for stepping up or stepping down ac


voltages or current, for isolation between two portion of a
circuit and for impedance matching.

 Transformer consists of two coils. The coils that is


directly connected to the voltage source is called the
primary winding.

 Coil that is connected to the load is called secondary


winding.
TRANSFORMERS
TRANSFORMERS

 The iron core of a transformer is made up of sheets


of rolled iron.

 This iron is treated such that it has high magnetic


conducting quality (high permeability) throughout the
length of the core.

 Permeability is the ability of a material to allow the


magnetic flux, φ to flow through it.
TRANSFORMERS

 From the figure, N1 and N2 is the number of turns for


primary winding and secondary winding respectively.

 V1 and V2 is the voltage across the primary winding and


secondary winding respectively.
TRANSFORMERS

 When a sinusoidal voltage is applied to the primary


winding, the same magnetic flux φ goes through
both windings.

 According to Faraday’s law, the voltage across the


primary winding and secondary winding are
d d
V1  N1 , V2  N 2
dt dt

or V1 = 4.44 φm f N1, V2 = 4.44 φm f N2

where φm is the maximum flux


f is the supply frequency
TRANSFORMERS
 Dividing both of the above equation gives
V2 N 2
 n
V1 N1
where n is the turns ratio or transformer ratio.

 For the reason of power conservation, the energy supplied to


the primary must equal the energy absorbed by the
secondary, since there are no losses in an ideal transformer.
Or the apparent power for both winding are the same. Thus,

S1  S 2  V1 I1  V2 I 2
I1 V2
 n
I 2 V1

 When n = 1, we generally call the transformer an isolation


transformer.
TRANSFORMERS

 If n > 1, we have a step-up transformer, as the


voltage is increased from primary to secondary
(V2 > V1).

 If n < 1, the transformer is a step-down transformer, since the


voltage is decreased from primary to secondary (V2 < V1).

 The rating of a transformer are usually specified as V1/V2.

 A transformer with rating 2400/120 V should have 2400V on


the primary and 120V on the secondary (a step-down
transformer)

 Keep in mind that the voltage ratings are in rms.


TRANSFORMERS

EXAMPLE:

An ideal transformer is rated at 2400/120 V, 9.6kVA and


has 50 turns on the secondary. Calculate
d) the turns ratio

e) the number of turns on the primary side

f) the current ratings for the primary and secondary


windings
TRANSFORMERS

Solution:

 This is a step-down transformer, since V1 = 2400V > V2


= 120V thus the turns ratio is
V2 120
n   0.05
V1 2400

N2 50
 n  0.05 
N1 N1
50
thus N1   1000 turns
0.05
TRANSFORMERS

 S = V1I1 = V2I2 = 9.6kVA. Hence,

9600 9600
I1    4A
V1 2400
9600 9600 I1 4
I2    80A or I2    80A
V2 120 n 0.05
POWER SUPPLY
 A power supply is a device or system that supplies
electrical or other types of energy to an output load
or group of loads.

 Figure below show the block diagram of a power supply


system.
POWER SUPPLY

 The power supply consists of rectifier, filter and


voltage regulators.

 Starting with an ac voltage, a steady dc voltage is


obtained by rectifying the ac voltage, then filtering to a dc
level and finally, regulating to obtain a desired fixed dc
voltage.

 The regulation is usually obtained from an IC voltage


regulator unit, which takes a dc voltage and provides a
somewhat lower dc voltage, which remains the same
even if the input dc voltage varies or the output load
connected to the dc voltage changes.
POWER SUPPLY
 The ac voltage, typically 240rms, is connected to a
transformer, which steps down that ac voltage to a level
for the desired dc output.

 A diode rectifier then provides a full-wave rectified


voltage/convert ac to dc voltage that is initially filtered by a
simple capacitor filter produce a dc voltage. This resulting dc
voltage usually has some ripple or ac voltage variation.

 A regulator circuit can use this dc input to provide a dc voltage


that not only has much less ripple voltage but also remains
the same dc value.

 This voltage regulation is usually obtained using one of a


number of popular voltage regulator IC units.
POWER SUPPLY

RECTIFIER

 In order to convert the ac voltage into dc voltage, a


rectifier circuit is needed.

 The rectifier can be divided into two types, half-wave


rectifier and full-wave rectifier.
POWER SUPPLY

 The half-wave rectifier uses the transformer during


only one-half of the cycle.

 Thus, for any given size transformer, less power is


developed than if the transformer were used on both
halves of the cycle.

 Therefore a full-wave rectifier is used.


POWER SUPPLY

Full-wave rectifier
1) Bridge network:

 Based on the figure above, during the period t = 0 to T/2


the polarity of the input and output are as shown in the
next figure.
POWER SUPPLY

 D2 and D3 are conducting while D1 and D4 are in


“off” state.

 The load voltage is vo = vi since the diodes are ideal.


POWER SUPPLY

 During the period t = T/2 to T the polarity of the


input and output are as shown in figure below.
POWER SUPPLY

 D1 and D4 are conducting while D2 and D3 are in


“off” state.

 The polarity of the output is the inverse of the input, thus


the full-wave waveform is produced.

 This produced waveform is then send to the filter.


POWER SUPPLY

2) Center-tapped transformer:

 A second popular full-wave rectifier which use only two


diodes but require a center-tapped transformer.

 During the positive portion of vi applied to the primary of


the transformer, D1 is assumed to be short-circuit while
D2 is open-circuit.
POWER SUPPLY

 During the negative portion of vi applied to the primary of


the transformer, D2 is assumed to be short-circuit while
D1 is open-circuit.
POWER SUPPLY

 From the figure it can be seen that the obtained


waveform is a full-wave rectifier waveform.
POWER SUPPLY

FILTER
 A filter is used to remove unwanted signal components.

 A very popular filter circuit is the capacitor-filter circuit


shown below.

 A capacitor is connected at the rectifier output and a dc


voltage is obtained across the capacitor.
POWER SUPPLY

 Figure 19.4(a) shows the output voltage of a


full-wave rectifier before and after the signal is filtered.
 Notice that the filtered waveform is essentially a dc
voltage with some ripple.
POWER SUPPLY

 To further reduce the amount of ripple across a


capacitor filter, one can add an additional RC filter
as shown below.
POWER SUPPLY

IC REGULATOR
 Regulator IC units contain the circuitry for reference
source, comparator amplifier, control devices and
overload protection all in a single IC.

 The IC regulator will provide an output dc voltage that is


regulated/maintained at a set value even if the input
voltage varies or if the load connected to the output
changes.

 The series 78 regulators provide fixed regulated voltages


from 5V to 24V. Example: A 7805 provide a +5V dc
output, a 7812 provide a +12V dc output.
POWER SUPPLY
POWER SUPPLY

 An unregulated input voltage Vi is filtered by capacitor C1


and connected to the IC’s IN terminal. The IC’s OUT
terminal provides a regulated +12V, which is filtered by
capacitor C2 (mostly for any high-frequency noise). The third
IC terminal is connected to ground (GND).

 The ac line voltage (120Vrms) is stepped down to 18Vrms.

 A full-wave rectifier and capacitor filter then provides an


unregulated dc voltage, shown as a dc voltage of about 22V,
with ac ripple of a few volts as input to the voltage regulator.

 The 7812 IC then provides an output that is a regulated +12V


dc.
MOTOR