CLIIMATLOGY
CLIIMATLOGY
CLIIMATLOGY
OTHER TECHNIQUES:
EVAPORATIVE COOLING
DESICCANT COOLING
TIME LAG COOLING
EARTH COOLING
CROSS VENTILATION
PEDA OFFICE
CHANDIGARH
Punjab Energy
Development Agency
(PEDA), Chandigarh is a
state nodal agency
responsible for
development of new &
renewable energy and nonconventional energy in the
state of Punjab.
GROUND FLOOR
PLAN
SECTION
Psychometric chart
TEMPERATURE
AND RAIN FALL
VARIATION
PEDA Office
OF THE ENERGY EFFICIENCY MOVEMENT IN THE NONDOMESTIC BUILDINGS SUCH AS OFFICES, EDUCATIONAL
INSTITUTIONS AND FACTORIES. THE BUILDING HAS THE
FOLLOWING SALIENT DESIGN FEATURES.
HYPERBOLIC PARABOLOID
SHELL ROOF
PEDA Office
SOLAR CHIMNEY
WIND TOWER COUPLED WITH SOLAR
CHIMNEYS: THE WIND TOWER CENTRALLY
PLACED COUPLED WITH SOLAR
CHIMNEYS ON THE DOMICAL
STRUCTURES FOR SCIENTIFIC DIRECT &
INDIRECT COOLING AND SCIENTIFIC
DRAFTING
OF USED AIR
TEMPERATURE RISE AND EFFICIENCY
SOLAR CHIMNEY under +overflow
PEDA Office
Solar Shells
day light for working
areas
OUTSIDE
STRUCTURAL OUTER
SKIN INTERACTS
WITH EXTERNAL
CONDITIONS
-WEATHER
-AIR TEMP.
-RADIATION
-HUMIDITY
-HUMIDITY
-LIGHT
-AIR TEMP.
-U.V.
INTER-STITIAL SPACE
Winter solstice
Equinox
Summer solstice
OVER SHADOWING
BUILDING IS NOT OVERSHADOWED BY ITS
SURROUNDING BUILDING, DUE TO ITS
ORIENTATIION AND WELL DESIGNED FACADES
,BUILDING IS HAVING ITS OWN SHADOW DURING
Simulation through
PHDC air flow tool
RESULTS
THE COMFORT TEMPERATURE RANGE VARIES FROM 24 TO 31 DURING
DIFFERENT SEASONS OF THE YEAR. COMFORT RELATIVE HUMIDITY RANGE
30TO 80 %. REQUIRED AIR FLOW RATE AS FROM MANUAL CALCULATIONS
CAN BE 3.5 M3/SEC. SO THE AIR FLOW RATE CAN BE ACHIEVED IN ALL THE
CASES. REQUIRED AIRFLOW RATE IS VERY LOW DUE TO LESS OCCUPANCY
AND EQUIPMENT GAIN. GOOD THERMAL MASS OF THE BUILDING HELPS THE
BUILDING TO PERFORM IN EXTREME CONDITIONS. APPROPRIATE BUILDING
DESIGN AND ORIENTATION HAVING PROPERLY PLACED BUILDING ELEMENTS
REDUCED OR MINIMIZE THE SOLAR GAIN IN SUMMER.
FEATURES LIKE LIGHT VAULT, SOLAR CHIMNEY, HYPERBOLIC PARABOLISED
ATRIUM ROOF HELP TO MINIMIZE THE SOLAR GAIN. INSTEAD OF DESIGNING
INDIRECT PLUS DIRECT EVAPORATIVE COOLING SYSTEM PROPOSED BY THE
ARCHITECT, PDEC SYSTEM CAN BE USED TO MAKE THE BUILDING FAVORABLE
PLACE TO WORK. FROM THE ABOVE RESULTS IT CAN BE CONCLUDED THAT
THE TEMPERATURE, RELATIVE HUMIDITY AND AIRFLOW RATE INCREASE FROM
CASE 1 TO CASE 3 WHICH LEADS TO UNSUCCESSFUL RESULT. HENCE THE
CENTRAL ATRIUM SPACE IN BETWEEN NEIGHBORING OFFICES IS WORKING
PROPERLY HAVING PDEC SYSTEM WITH ONE TOWER AND IT WOULD BE THE
BEST OPTION TO WORK WITH. FROM ALL THE CASES WE CAN CONCLUDE
THAT GROUND OFFICE SPACE ALSO GETTING AN AMBIENT TEMPERATURE
DURING SUMMER.
CONCLUSIONS
Evaporative cooling towers work best with open floor plans that
permit the air to circulate through out the building without any
obstacles.
Good thermal mass of the building helps the building to perform in
extreme conditions. Appropriate building design and orientation
having properly placed building elements reduced or minimize the
solar gain in summer.
Elements like light Vault, Solar chimney, Hyperbolic parabolised
atrium roof help to minimize the solar gain.
From the TAS result it can be concluded that the atrium space is
working properly with application of PDEC system by getting 1012C lower than ambient temperature, which also helps to cool the
neighboring south office space to maintain a comfortable space to
work.