Final Presentation Design of Peb Systems: Group 5 Piyush Singh CE18M103
Final Presentation Design of Peb Systems: Group 5 Piyush Singh CE18M103
Final Presentation Design of Peb Systems: Group 5 Piyush Singh CE18M103
GROUP 5
PIYUSH SINGH
CE18M103
PROBLEM STATEMENT
RESULTANTS AT
1 : M = 0 , V = 332 kN
2 : M = 1267 kN , V = 98.6 kN
3 : M = 867 kN, V = 168 kN
4 : M = 2102 kN , V = 17.8 kN
DESIGN OF FRAME ELEMENTS
Mezzanine Specifications
Fyp = 280 N/mm2
tp = 0.86 mm
Ap = 1205 mm2
Ip = 0.65 x 106 mm4/m
Mpa = 5 kNm/m
e = 40 mm
ep = 35 mm
Vp = 50 kN
m = 184 N/mm2
k = 0.053 N/mm2
DESIGN OF MEZZANINE SYSTEM
(…continued)
Load Considered (With load factors)
Dead Loads @ 2.5 kN/m2 (x1.35)
Live Loads @ 4 kN/m2 (x1.5)
Construction Loads @ 1.5 kN/m2 (x 1.5)
DESIGN OF MEZZANINE SYSTEM
(…continued)
Construction Stage
Le = 2.445 m
Ms = 2.96 kNm/m
Mh = 3.5 kNm/m
Md = 4.35 kNm/m
Deflection = 6.44 mm
Vertical Shear
@ External Support = 6.72 kN/m
@ Prop = 8.06 kN/m
DESIGN OF MEZZANINE SYSTEM
(…continued)
Composite Stage Composite Stage
Serviceability Le = 4.92 m
As = 360 mm2/m for crack control Msd = 28.37 kNm/m (mid span)
Deflection < span/140 Vertical Shear = 23.75 kN/m
(30.72 ; 35 ) Ncf = 293.4 kN/m
Shear Connectors Fcd = 10.8 N/mm2
20mm Ø , 75 mm high studs X = 27.7 mm
Capacity = 58 kN Mp,rd = 33.1 kNm/m
5 studs between support and point of Vv,RD = 50.9 kN/m
maximum moment (Fa = 273.9)
Vi,RD = 37.1 kN/m
7 studs between point of maximum
moment and internal support (Vλ = 352.2
kN)
DESIGN OF MEZZANINE SYSTEM
(…continued)
Supporting Beams 2 : NPB 400 x 180 @ 66.3 kg/m
Allowable Deflection = 26 mm
DESIGN OF MEZZANINE SYSTEM
(…continued)
Cantilever Beam Columns
NPB 700 x 250 @ 171.47 kg/m NPB 250 x 150 @ 39.78 kg/m
b/tf = 5.31 < 9.4 Buckling Class ‘C’
d/tw = 48.27 < 84 Compressive capacity = 209.1 kN
The section is PLASTIC Compression Applied = 170 kN
Moment Capacity = 1148.68 kNm
Moment Demand = 1035 kNm
Maximum Deflection = 25.9 mm
Allowable Deflection = 50 mm
Design of Purlins and Girts
A bisymmetric 6 x 8 bolt
arrangement is provided.
Vextreme = 308 kN < 334.4 kN
18 mm thick plates are used.
Out-Of-Plane Bracket Moment
Connection
A 10 bolt connection is provided
8 bolts are in the tension zone.
30 mm thick end plates are used.
Effective With of Plates = 300 mm
Prying Force Check is OK
Interaction Check is OK
Remaining Work