Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Automatic Valves

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 33

Automatic valves

FIP TRAINING
Automatic valves

FIP range:

1)Pneumatic quarter turn (0-90°)

2)Electric quarter turn (0-90°….)

3)Pneumatic linear

4)Electric linear
Automatic valves
1)Pneumatic quarter turn (0-90°)

Pneumatic actuator:
Body: Anodized Alluminium
Caps: Epoxi coated alluminium

Two operating principle:


1) Double acting
2) Single acting
Automatic valves

Double acting

Air pressure in inlet A : Air pressure in inlet B :


anti clock-wise rotation clock-wise rotation
Automatic valves

Single acting

Air pressure in inlet A : No air pressure : clock-


anti clock-wise rotation wise rotation (spring
return)
Automatic valves

NAME VK/CP VKD/CP TK/CP FE/CP


FK/CP

SIZE 16-63 mm 75-110mm 16-63 mm 50-225mm 50-


315mm

FUNCTION NC/NO/DA NC/NO/DA SA/DA NC/NO/DA


NC/NO/DA
Automatic valves

PNEUMATIC VALVE ACCESSORIES

1 2 3 4

• 1 Optical position indicator

• 2 Pilot valve 3-5/2 ways for single acting and double acting actuators

• 3 Microswitch box mechanical or inductive

• 4 Positioner 4-20 mA
Automatic valves
Pilot valve 3-5/2 ways for single acting and double acting actuators
Automatic valves
Microswitch box mechanical or inductive

Electro mechanical Inductive wiring 2


wiring or 3 wires
Automatic valves

2)Electric quarter turn (0-90°….)

Plastic cover
Standard:
Manual override
Optical indiction
2 auxiliary limit switches

Availble voltages: 12-24 VDC // 12-24-115-230VAC


Duty cycle: 30% or 50%
Working time: from 4 to 65 seconds (more on request)
Enclosure: IP 65 (IP67)
Automatic valves

FC1

FC2
FCO
FCF

FC1
Auxiliary cam which
gives the opening signal
FC2
Auxiliary cam which
gives the closing signal

FCO
Cam which gives the
opening impulse

FCF
Cam which gives the
closing impulse
Automatic valves

NAME VK/CE VKD/CE TK/CE FE/CE FK/CE

SIZE 16-63 mm 75-110mm 16-63 mm 50-225mm 50-315mm

FUNCTION ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF


Automatic valves
ELECTRIC VALVE ACCESSORIES

• 1 Heater resistor • 2 Potentiometer 3 Positioner 4 -20 mA

• 4 Safe battery • 5 3rd position (TK)


Automatic valves
CONFIGURATION TK / CP-CE L BORE

Configuration 1
(STANDARD)
Automatic valves
CONFIGURATION TK / CP-CE T BORE

Configuration 1

(STANDARD)

Configuration 2

Configuration 3

Configuration 4
Automatic valves
TK ACTUATION COMPONENTS

•For direct actuation:


Stainless steel coupling

• Adaptation kit for


actuators F05 to be mounted
on valves TK D40-50-63
Automatic valves

3)Pneumatic linear

NAME VM/CP CM/CP DM/CP PM/CP


VV/CP

SIZE 20-110 mm 16-20 mm 20-63mm 20-63mm 20-63mm

FUNCTION NC/NO/DA NC/NO/DA NO NC NC/NO/DA


Automatic valves
VM/NC
COMPONENTS/CHARACTERISTICS

Characteristics
• High KV factor

• Possible Mounting of Accessories on the


Valve already Installed

• Easy Replacement of the Valve Diaphragm

• Metallic Reinforcements Included in the


Top of the Actuator

• All Bodies DN 15÷50 Aligned at the


Same Pipe-Center-Line by Means of
Only one Plate
Automatic valves
VM/NO
COMPONENTS/CHARACTERISTICS

Characteristics
• High KV

• Possible Mounting of Accessories on the


Valve already Installed

• Easy Replacement of the Valve Diaphragm

• Metallic Reinforcements Included in the


Top of the Actuator

• The Version N.O. Can Also Operate As


Double Acting Valve
Automatic valves
CONTROL/WORKING PRESSURE

FIP VM/NC FIP VM/NO


bar bar
6 6
Control pressure
Control pressure

5 5 DN 32, 40, 50
DN65 ÷ 80
4 4 DN65 ÷ 100
3 3
2 2
DN15 ÷ 50
1 1 DN 15, 20, 25
0 0
1 2 3 4 5 6 7 8 9 10 bar 1 2 3 4 5 6 7 8 9 10 bar
Working Pressure Working Pressure
Automatic valves
DM/NO
COMPONENTS/CHARACTERISTICS

Characteristics
• Simple and Reliable Technology
at a Low Price

• Standard Provided with Epdm


Reinforced Diaphragm

Accessories
• Stroke Limiter Plus Optical Position
Indicator

• Pilot Valve
Automatic valves
PM/NC
COMPONENTS/CHARACTERISTICS

Characteristics
• Piston actuators
More compact
PN8 DN15-25
PN6 DN32-40
PN4 DN50

• Standard Provided with EPDM


or FPM Reinforced Diaphragm
• Lower price (endurance)
Automatic valves
PNEUMATICALLY ACTUATED
ANGLE-SEAT VALVE
• FIP MOULDED ACTUATOR No External
Metal Part
• Normally Closed
• Normally Open
• Double Acting

• INTERNAL HYDRAULIC The Best on


Performances
CIRCUIT
4-6 bar
• CONTROL PRESSURE
10 bar for All the
• MAXIMUM WORKING Range DN 10-50
PRESSURE
• POSITION INDICATOR
AS STANDARD

• APPLICATION FIELDS:
See Solenoid Valves and Diaphragm Valves, In fact
They Are Often Used Together with Solenoid Valves in
Dosing Plants and Instead of Diaphragm Valves When
the Fluid is Clean and not Viscous
Automatic valves
ACCESSORIES

1 2 3 4 5 6 7 8 9
• 1 Stroke Limiter
• 2 Stroke Limiter with Optical Position Indicator

• 3 Stroke Limiter with Position Indicator


and Emergency Manual Override

• 4 Optical Position Indicator

• 5 Electromechanical Position Indicator ( 1 Microswitch )

• 6 Electromechanical Position Indicator ( 2 Microswitches ) for VM


• 7 Electromechanical Position Indicator ( 2 Microswitches ) for CM

• 6-7 alternative: Inductive Position Indicator

• 8 Pneumatic or Electropneumatic Positioner

• 9 Direct or Battery Mounted Pilot Valve


Automatic valves

4)Electric linear

NAME S.11-S.21 S.13-S.23

SIZE 16-20 mm 16-20 mm

FUNCTION NC NC/NO/MX/DT
Automatic valves
THE SOLENOID:
OPERATING PRINCIPLE

Power Movable Magnetic Core


Connection
Copper Wiring

Fixed Magnetic Core

Spindle
• VOLTAGES AVAILABLE
A.C.: 24 - 48 - 110 - 220 - 240 - 250 at 50/60 Hz
D.C.: 12 - 24 - 48 - 110
NOTE: When Changing the Voltage of a Valve, Always Change
Both
the Solenoid and the Connector.
• DUTY: 100% ED Continuous Working
• ENVIRONMENT PROTECTION: IP 65 ( NEMA 4X )
Totally Protected Against Dust and Water Jet
• MANUAL OVERRIDE AS STANDARD
Automatic valves

S.1. ND 2 - 4 - 6 - 8 lower overall dimensions


S.2. ND 8 - 10 - 15 larger overall dimensions

Body material: PVC Seals: EPDM or FPM


On request C-PVC

Connections:

Type DN d R
mm ISO BS ASTM BSP NPT
10 1/4" 1/4" 1/4" 1/4"
S.1. 2-4-6-8 12 3/8" 3/8" 3/8" 3/8"
16

16 3/8" 3/8" 3/8" 3/8"


S.2. 8-10-15 20 1/2" 1/2" 1/2" 1/2"
Automatic valves
Connector
Metal parts
Silent with light
insulated
solenoid with indicator
from fluid
DC current

Manual
override

Lever type
Different Standard
true-union
connection
Automatic valves

2/2 AND 3/2


WAYS SOLENOID VALVE

1 2 1 2

3
Automatic valves

CONTROL FUNCTIONS
(2/2 WAYS)

2/2 Normally Closed

De-Energised Solenoid Energised Solenoid


Automatic valves
CONTROL FUNCTIONS
(3/2 WAY)
3/2 Normally Closed

De-Energised Solenoid Energised Solenoid

3/2 Normally Open

De-Energised Solenoid Energised Solenoid


Automatic valves
CONTROL FUNCTIONS
(3/2 WAYS)
3/2 Mixer

De-Energised Solenoid

Energised Solenoid
3/2 Diverter

De-Energised Solenoid Energised Solenoid


Automatic valves
THE S1/S2 NAMES
S DN D

240 EPDM
NC AC FPM
110 DC
NO 24
MX 12
DT
DN2-4-6-8
1= 2 Ways DN 8-10-15
3= 3 Ways

1 Small D 10 12 16 20
2 Large D 1/4” 3/8” 1/2”

I= solvent welding end connections ISO


L= solvent welding end connections BS
F= threaded end connections BSP

You might also like