In this module, you can review all

the APU controls and indications.

APU MENU Summary 1/16


APU Panel
APU MASTER SW pb sw

APU START pb sw

Select any yellow button for review.

APU MENU Summary 2/16


APU Panel
APU MASTER SW pb sw

Controls the power supply of the


APU and allows the start sequence to
begin when the START pb sw is
pushed.
When selected OFF:
- the APU shuts down APU START pb sw
after 2 mn to cool down if
the APU bleed was used.

When pressed ON:


- the APU air inlet flap
opens
- the ECAM APU page
is displayed.

FAULT light illuminates


when an automatic or an
emergency shut down
occurs.

APU MENU Summary 3/16


APU Panel
APU MASTER SW pb sw

APU START pb sw

When pressed ON, the


APU starting sequence is
initiated.

The AVAIL light


illuminates green
meaning that the APU is
available to supply
electrical power and/or
bleed air.

APU MENU Summary 4/16


ECAM APU Page (1/2)
AVAIL INDICATION

APU GEN PARAMETERS

APU BLEED VALVE POSITION

APU BLEED AIR PRESSURE

Select any yellow button for review.

APU MENU Summary 5/16


ECAM APU Page (1/2)
AVAIL INDICATION

APU GEN PARAMETERS

These indications
give information on
the APU generator
parameters. APU BLEED VALVE POSITION

For more details,


see the ELECTRICAL
chapter.

APU BLEED AIR PRESSURE

APU MENU Summary 6/16


ECAM APU Page (1/2)
AVAIL INDICATION

APU GEN PARAMETERS


Displayed in green.
The APU is available to
supply electrical power
and/or bleed air.

APU BLEED VALVE POSITION

APU BLEED AIR PRESSURE

APU MENU Summary 7/16


ECAM APU Page (1/2)
AVAIL INDICATION

APU GEN PARAMETERS

APU BLEED VALVE POSITION

Valve is open.

Valve is fully
closed

APU BLEED AIR PRESSURE

APU MENU Summary 8/16


ECAM APU Page (1/2)
AVAIL INDICATION

APU GEN PARAMETERS

APU BLEED VALVE POSITION

APU BLEED AIR PRESSURE

Displays the
available bleed air
pressure in green.

APU MENU Summary 9/16


ECAM APU Page (2/2)
APU N INDICATION
FUEL LO PR INDICATION

FLAP OPEN INDICATION


APU EGT INDICATION

LOW OIL LEVEL INDICATION

Select any yellow button for review.

APU MENU Summary 10/16


ECAM APU Page (2/2)
APU N INDICATION
FUEL LO PR INDICATION

Displayed in green
when the APU speed
is normal.

Amber or red if out


of limits.

FLAP OPEN INDICATION


APU EGT INDICATION

LOW OIL LEVEL INDICATION

APU MENU Summary 11/16


ECAM APU Page (2/2)
APU N INDICATION
FUEL LO PR INDICATION

FLAP OPEN INDICATION


APU EGT INDICATION

Displayed in green
at normal operating
temperatures.

Amber or red when LOW OIL LEVEL INDICATION


out of limits.

APU MENU Summary 12/16


ECAM APU Page (2/2)
APU N INDICATION
FUEL LO PR INDICATION

Displayed in amber
when an APU fuel low
pressure is detected.

FLAP OPEN INDICATION


APU EGT INDICATION

LOW OIL LEVEL INDICATION

APU MENU Summary 13/16


ECAM APU Page (2/2)
APU N INDICATION
FUEL LO PR INDICATION

FLAP OPEN INDICATION


APU EGT INDICATION

Displayed in green
when the APU air inlet
flap is fully open.

LOW OIL LEVEL INDICATION

APU MENU Summary 14/16


ECAM APU Page (2/2)
APU N INDICATION
FUEL LO PR INDICATION

FLAP OPEN INDICATION


APU EGT INDICATION

LOW OIL LEVEL INDICATION

Advisory displayed
when an APU oil low
quantity is detected.

APU MENU Summary 15/16


APU Panel ECAM APU Page

You have reviewed all the APU controls and


indications.
Have some fun with the quiz !

Module completed

APU MENU Summary 16/16 NEXT


LIST OF SUBJECTS
APU PANEL

ECAM APU PAGE (1/2)

ECAM APU PAGE (2/2)

REVIEW

AUDIO GLOSSARY FCOM

RETURN EXIT

APU MENU Summary 17/16

You might also like