Showing 1–9 of 9 results for author: Redaelli, N

.
  1. arXiv:2404.01208  [pdf

    physics.ins-det hep-ex

    TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector

    Authors: E. Albuquerque, M. Araújo, A. Benaglia, A. Boletti, R. Bugalho, T. Coutinho, F. De Guio, P. Faccioli, L. Ferramacho, M. Firlej, T. Fiutowski, R. Francisco, M. Gallinaro, A. Ghezzi, J. Hollar, M. Idzik, H. Legoinha, N. Leonardo, C. Leong, M. T. Lucchini, M. Malberti, G. Marozzo, G. Da Molin, J. Moron, T. Niknejad , et al. (16 additional authors not shown)

    Abstract: The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.… ▽ More

    Submitted 1 April, 2024; originally announced April 2024.

    Comments: Editor: J. Varela

  2. arXiv:2106.13654  [pdf, other

    physics.ins-det hep-ex

    Effective exploitation of a geyser bubble-chamber equipment as a background-free fast neutron detector

    Authors: R. Bertoni, G. Bruno, N. Burgio, M. Corcione, L. Cretara, M. Frullini, W. Fulgione, G. Palmerini, A. Quintino, N. Redaelli, A. Santagata, D. Sorrenti, L. Zanotti

    Abstract: MOSCAB equipment, a geyser-concept bubble-chamber originally thought for the search of dark matter in the form of WIMPs, is employed for the detection of fast neutrons. Once the background-free operating conditions are determined such that the detector is sensitive only to neutrons, which occurs when the neutron energy threshold required for nucleation is higher than approximately 2.5 MeV, the d… ▽ More

    Submitted 25 June, 2021; originally announced June 2021.

    Comments: 16 pages, 10 figures, submitted to EPJ C

  3. Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector

    Authors: R. Abbott, A. Abreu, F. Addesa, M. Alhusseini, T. Anderson, Y. Andreev, A. Apresyan, R. Arcidiacono, M. Arenton, E. Auffray, D. Bastos, L. A. T. Bauerdick, R. Bellan, M. Bellato, A. Benaglia, M. Benettoni, R. Bertoni, M. Besancon, S. Bharthuar, A. Bornheim, E. Brücken, J. N. Butler, C. Campagnari, M. Campana, R. Carlin , et al. (174 additional authors not shown)

    Abstract: The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about… ▽ More

    Submitted 16 July, 2021; v1 submitted 15 April, 2021; originally announced April 2021.

    Journal ref: Journal of Instrumentation, Volume 16, July 2021

  4. arXiv:1708.00101  [pdf, other

    physics.ins-det hep-ex

    MOSCAB: A geyser-concept bubble chamber to be used in a dark matter search

    Authors: The MOSCAB Collaboration, A. Antonicci, M. Ardid, R. Bertoni, G. Bruno, N. Burgio, G. Caruso, D. Cattaneo, F. Chignoli, M. Clemenza, M. Corcione, L. Cretara, D. Cudy, I. Felis, M. Frullini, W. Fulgione, G. Lucchini, L. Manara, M. Maspero, A. Papagni, M. Perego, R. Podviyanuk, A. Pullia, A. Quintino, N. Redaelli , et al. (4 additional authors not shown)

    Abstract: The MOSCAB experiment (Materia OSCura A Bolle) uses the "geyser technique", a variant of the superheated liquid technique of extreme simplicity. Operating principles of the new dark matter detector and technical solutions of the device are reported in detail. First results obtained in a series of test runs taken in laboratory demonstrate that we have successfully built and tested a geyser-concept… ▽ More

    Submitted 31 July, 2017; originally announced August 2017.

    Comments: 11pages, 7 figures, 1 table

  5. arXiv:1411.4413  [pdf, other

    hep-ex hep-ph

    Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data

    Authors: The CMS, LHCb Collaborations, :, V. Khachatryan, A. M. Sirunyan, A. Tumasyan, W. Adam, T. Bergauer, M. Dragicevic, J. Erö, M. Friedl, R. Frühwirth, V. M. Ghete, C. Hartl, N. Hörmann, J. Hrubec, M. Jeitler, W. Kiesenhofer, V. Knünz, M. Krammer, I. Krätschmer, D. Liko, I. Mikulec, D. Rabady, B. Rahbaran , et al. (2807 additional authors not shown)

    Abstract: A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta… ▽ More

    Submitted 17 August, 2015; v1 submitted 17 November, 2014; originally announced November 2014.

    Comments: Correspondence should be addressed to cms-and-lhcb-publication-committees@cern.ch

    Report number: CERN-PH-EP-2014-220, CMS-BPH-13-007, LHCb-PAPER-2014-049

    Journal ref: Nature 522, 68-72 (04 June 2015)

  6. arXiv:1311.2214  [pdf, ps, other

    astro-ph.IM physics.ins-det

    A new technique for direct investigation of dark matter

    Authors: R. Bertoni, F. Chignoli, D. Chiesa, D. Chiesa, M. Clemenza, G. Lucchini, R. Mazza, P. Negri, A. Pullia, N. Redaelli, L. Zanotti, D. Cundy

    Abstract: The MOSCAB experiment (Materia OSCura A Bolle) uses a new technique for Dark Matter search. The Geyser technique is applied to the construction of a prototype detector with a mass of 0.5 kg and the encouraging results are reported here; an accent is placed on a big detector of 40 kg in construction at the Milano-Bicocca University and INFN.

    Submitted 9 November, 2013; originally announced November 2013.

  7. arXiv:0912.4300  [pdf

    physics.ins-det hep-ex

    Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter

    Authors: The CMS Electromagnetic Calorimeter Group, P. Adzic, N. Almeida, D. Andelin, I. Anicin, Z. Antunovic, R. Arcidiacono, M. W. Arenton, E. Auffray, S. Argiro, A. Askew, S. Baccaro, S. Baffioni, M. Balazs, D. Bandurin, D. Barney, L. M. Barone, A. Bartoloni, C. Baty, S. Beauceron, K. W. Bell, C. Bernet, M. Besancon, B. Betev, R. Beuselinck , et al. (245 additional authors not shown)

    Abstract: Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews t… ▽ More

    Submitted 21 December, 2009; originally announced December 2009.

    Comments: 24 pages, 19 figures, available on CMS information server at http://cms.cern.ch/iCMS/

    Report number: CMS Note 2009/016

    Journal ref: JINST 5:P03010,2010

  8. A new concept for streamer quenching in resistive plate chambers

    Authors: A. Calcaterra, R. de Sangro, G. Mannocchi, P. Patteri, P. Picchi, M. Piccolo, N. Redaelli, T. Tabarelli de Fatis, G. C. Trinchero

    Abstract: In this paper we propose a new concept for streamer quenching in Resistive Plate Chambers (RPCs). In our approach, the multiplication process is quenched by the appropriate design of a mechanical structure inserted between the two resistive electrodes. We show that stable performance is achieved with binary gas mixtures based on argon and a small fraction of isobutane. Fluorocarbons, deemed resp… ▽ More

    Submitted 21 February, 2006; originally announced February 2006.

    Comments: 11 pages, 6 figures, accepted by Nucl. Instr. and Meth. A

    Report number: LNF-05/13(P)

    Journal ref: Nucl.Instrum.Meth.A565:444-449,2006; Erratum-ibid.A564:615,2006

  9. arXiv:hep-ex/9907024  [pdf, ps, other

    hep-ex

    Measurement of neutrino oscillations by means of a high density detector on the atmospheric neutrino beam

    Authors: M. Aglietta, M. Ambrosio, E. Aprile, G. Bologna, M. Bonesini, G. Bencivenni, M. Calvi, A. Castellina, A. Curioni, W. Fulgione, P. L. Ghia, C. Gustavino, R. P. Kokoulin, G. Mannocchi, F. Murtas, G. P. Murtas, P. Negri, M. Paganoni, L. Periale, A. A. Petrukhin, P. Picchi, A. Pullia, S. Ragazzi, N. Redaelli, L. Satta , et al. (6 additional authors not shown)

    Abstract: A high-density calorimeter, consisting of magnetized iron planes interleaved by RPCs, as tracking and timing devices, is a good candidate for a next generation experiment on atmospheric neutrinos. With 34 kt of mass and in four years of data taking, this experiment will be sensitive to $ν_μ\to ν_x$ oscillation with $Δm^2 > 6 \times 10^{-5}$ and mixing near to maximal and fully cover the region o… ▽ More

    Submitted 15 July, 1999; originally announced July 1999.

    Comments: 12 pp., 5 figg., paper contributed to Lepton-Photon 99