Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–15 of 15 results for author: Ferrer-Ribas, E

Searching in archive astro-ph. Search in all archives.
.
  1. arXiv:2010.12076  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory

    Authors: A. Abeln, K. Altenmüller, S. Arguedas Cuendis, E. Armengaud, D. Attié, S. Aune, S. Basso, L. Bergé, B. Biasuzzi, P. T. C. Borges De Sousa, P. Brun, N. Bykovskiy, D. Calvet, J. M. Carmona, J. F. Castel, S. Cebrián, V. Chernov, F. E. Christensen, M. M. Civitani, C. Cogollos, T. Dafní, A. Derbin, K. Desch, D. Díez, M. Dinter , et al. (101 additional authors not shown)

    Abstract: This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for… ▽ More

    Submitted 4 March, 2021; v1 submitted 22 October, 2020; originally announced October 2020.

    Comments: 77 pages, 49 figures. Prepared for submission to JHEP. Third version after referees comments

  2. arXiv:1610.02396  [pdf, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    Readout technologies for directional WIMP Dark Matter detection

    Authors: J. B. R. Battat, I. G. Irastorza, A. Aleksandrov, M. Ali Guler, T. Asada, E. Baracchini, J. Billard, G. Bosson, O. Bourrion, J. Bouvier, A. Buonaura, K. Burdge, S. Cebrian, P. Colas, L. Consiglio, T. Dafni, N. D'Ambrosio, C. Deaconu, G. De Lellis, T. Descombes, A. Di Crescenzo, N. Di Marco, G. Druitt, R. Eggleston, E. Ferrer-Ribas , et al. (68 additional authors not shown)

    Abstract: The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial… ▽ More

    Submitted 6 October, 2016; originally announced October 2016.

    Comments: 58 pages, 26 figures, accepted by Physics Reports

    Journal ref: Physics Reports 662 (2016) pp. 1-46

  3. arXiv:1509.06190  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research

    Authors: F. Aznar, J. Castel, F. E. Christensen, T. Dafni, T. A. Decker, E. Ferrer-Ribas, J. A. Garcia, I. Giomataris, J. G. Gracia, C. J. Hailey, R. M. Hill, F. J. Iguaz, I. G. Irastorza, A. C. Jakobsen, G. Luzon, H. Mirallas, T. Papaevangelou, M. J. Pivovaroff, J. Ruz, T. Vafeiadis, J. K. Vogel

    Abstract: We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed… ▽ More

    Submitted 21 September, 2015; originally announced September 2015.

    Comments: 21 pages, 16 figures

  4. arXiv:1508.03006  [pdf, other

    astro-ph.IM physics.ins-det

    Exploring 0.1-10$\,$eV axions with a new helioscope concept

    Authors: J. Galán, T. Dafni, E. Ferrer-Ribas, I. Giomataris, F. J. Iguaz, I. G. Irastorza, J. A. García, J. Gracia, G. Luzón, T. Papaevangelou, J. Redondo, A. Tomás

    Abstract: We explore the possibility to develop a new axion helioscope type, sensitive to the higher axion mass region favored by axion models. We propose to use a low background large volume TPC immersed in an intense magnetic field. Contrary to traditional tracking helioscopes, this detection technique takes advantage of the capability to directly detect the photons converted on the buffer gas which defin… ▽ More

    Submitted 7 September, 2015; v1 submitted 12 August, 2015; originally announced August 2015.

    Comments: prepared for submission to JCAP

  5. arXiv:1504.05865  [pdf, other

    astro-ph.IM nucl-ex physics.ins-det

    First detection of tracks of radon progeny recoils by MIMAC

    Authors: Q. Riffard, D. Santos, G. Bosson, O. Bourrion, T. Descombes, C. Fourel, O. Guillaudin, J. -F. Muraz, P. Colas, E. Ferrer-Ribas, I. Giomataris, J. Busto, D. Fouchez, C. Tao, L. Lebreton, D. Maire

    Abstract: The MIMAC experiment is a $μ$-TPC matrix project for directional dark matter search. Directional detection is a strategy based on the measurement of the WIMP flux anisotropy due to the solar system motion with respect to the dark matter halo. The main purpose of MIMAC project is the measurement of the energy and the direction of nuclear recoils in 3D produced by elastic scattering of WIMPs. Since… ▽ More

    Submitted 20 June, 2017; v1 submitted 22 April, 2015; originally announced April 2015.

    Comments: 11 pages, 12 figures, submitted to PRD

  6. arXiv:1503.04561  [pdf, other

    astro-ph.SR hep-ph physics.ins-det

    Search for chameleons with CAST

    Authors: V. Anastassopoulos, M. Arik, S. Aune, K. Barth, A. Belov, H. Bräuninger, G. Cantatore, J. M. Carmona, S. A. Cetin, F. Christensen, J. I. Collar, T. Dafni, M. Davenport, K. Desch, A. Dermenev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis , et al. (39 additional authors not shown)

    Abstract: In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($β_{\rm m}$) and to photons ($β_γ$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to… ▽ More

    Submitted 18 March, 2016; v1 submitted 16 March, 2015; originally announced March 2015.

    Comments: 8 pages, 12 figures

  7. arXiv:1501.01466  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches

    Authors: F. J. Iguaz, S. Aune, F. Aznar, J. F. Castel, T. Dafni, M. Davenport, E. Ferrer-Ribas, J. Galan, J. A. Garcia, J. G. Garza, I. Giomataris, I. G. Irastorza, T. Papaevangelou, A. Rodriguez, A. Tomas, T. Vafeiadis, S. C. Yildiz

    Abstract: Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observ… ▽ More

    Submitted 7 January, 2015; originally announced January 2015.

    Comments: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014)

    Journal ref: Pos(TIPP2014) 295

  8. arXiv:1307.1985  [pdf, ps, other

    hep-ex astro-ph.IM physics.ins-det

    CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap

    Authors: M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Brauninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, E. Da Riva, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galan, J. A. Garcia, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, E. Georgiopoulou , et al. (50 additional authors not shown)

    Abstract: The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10}… ▽ More

    Submitted 15 September, 2014; v1 submitted 8 July, 2013; originally announced July 2013.

    Comments: 5 pages, 2 figures. Last version uploaded

    Journal ref: Phys. Rev. Lett. 112, 091302 (2014)

  9. arXiv:1210.3287  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures

    Authors: S. Cebrián, T. Dafni, E. Ferrer-Ribas, I. Giomataris, D. Gonzalez-Diaz, H. Gómez, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzon, A. Rodríguez, L. Segui, A. Tomás

    Abstract: In this work we present a systematic study of Micromegas detectors in high pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains and energy resolutions for 22.1 keV X-rays are measured for pressures between 1 and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We observe stable operation at all pressures, and a strongly enhanced gas gain, suggestive of… ▽ More

    Submitted 23 November, 2012; v1 submitted 11 October, 2012; originally announced October 2012.

  10. arXiv:1209.6347  [pdf, other

    hep-ex astro-ph.CO

    Results and perspectives of the solar axion search with the CAST experiment

    Authors: E. Ferrer-Ribas, M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Bräuninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, C. Ezer, G. Fanourakis, P. Friedrich, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, I. Giomataris , et al. (47 additional authors not shown)

    Abstract: The status of the solar axion search with the CERN Axion Solar Telescope (CAST) will be presented. Recent results obtained by the use of $^3$He as a buffer gas has allowed us to extend our sensitivity to higher axion masses than our previous measurements with $^4$He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV… ▽ More

    Submitted 30 October, 2012; v1 submitted 27 September, 2012; originally announced September 2012.

    Comments: 4 pages, 2 pages, to appear in the proceedings of the 24th Rencontres de Blois V2 A few affiliations were not corrected in previous version V3 Author added

  11. arXiv:1208.5690  [pdf, other

    physics.ins-det astro-ph.SR hep-ex

    CAST microbulk micromegas in the Canfranc Underground Laboratory

    Authors: A. Tomás, S. Aune, T. Dafni, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gómez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzón, T. Papaevangelou, A. Rodríguez, J. Ruz, L. Seguí, T. Vafeiadis, S. C. Yildiz

    Abstract: During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of $\approx 5 \times 10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies… ▽ More

    Submitted 28 August, 2012; originally announced August 2012.

    Comments: 6 pages, 8 figures. To appear in the proceedings of the 2nd International Conference on Technology and Instrumentation for Particle Physics (TIPP 2011)

    Journal ref: Proceedings of the 2nd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2011) Volume 37, 2012, Pages 478-482

  12. arXiv:1201.3012  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Characterization of microbulk detectors in argon- and neon-based mixtures

    Authors: F. J. Iguaz, E. Ferrer-Ribas, A. Giganon, I. Giomataris

    Abstract: A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at 5.9 keV in Ar+5%iC4H10. This detector has other advantages like its flexible structure, low material budget and high radio-purity. Two microbulk detectors with g… ▽ More

    Submitted 14 January, 2012; originally announced January 2012.

    Comments: Submitted to the Journal of Instrumentation

  13. arXiv:1110.2608  [pdf, other

    physics.ins-det astro-ph.IM

    Low X-ray bakground measurements at the Underground Canfranc Laboratory

    Authors: J. Galan, S. Aune, T. Dafni, G. Fanourakis, E. Ferrer-Ribas, J. A. Garcia, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gomez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzon, T. Papaevangelou, A. Rodriguez, J. Ruz, L. Segui, A. Tomas, T. Vafeiadis, S. C. Yildiz

    Abstract: Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have motivated further studies in the nature of the background levels measured. In particular, different shielding configurations have been tested at the Canfranc Undergrou… ▽ More

    Submitted 25 October, 2011; v1 submitted 12 October, 2011; originally announced October 2011.

    Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011

  14. arXiv:1109.1675  [pdf, other

    physics.ins-det astro-ph.IM

    Micromegas detector developments for MIMAC

    Authors: E. Ferrer-Ribas, D. Attié, D. Calvet, P. Colas, F. Druillole, Y. Giomataris, F. J. Iguaz, J. P. Mols, J. Pancin, T. Papaevangelou, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, D. Santos, C. Golabek, L. Lebreton

    Abstract: The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.

    Submitted 12 September, 2011; v1 submitted 8 September, 2011; originally announced September 2011.

    Comments: 8 pages, 7 figures Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011; corrections on author affiliations

  15. arXiv:1009.1827  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex

    Micromegas readouts for double beta decay searches

    Authors: S. Cebrián, T. Dafni, E. Ferrer-Ribas, J. Galán, J. A. García, I. Giomataris, H. Gómez, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzón, A. Rodríguez, L. Seguí, A. Tomás

    Abstract: Double beta $ββ$ decay experiments are one of the most active research topics in Neutrino Physics. The measurement of the neutrinoless mode $0νββ$ could give unique information on the neutrino mass scale and nature. The current generation of experiments aims at detector target masses at the 100 kg scale, while the next generation will need to go to the ton scale in order to completely explore the… ▽ More

    Submitted 9 September, 2010; originally announced September 2010.

    Comments: 15 pages, 11 figures. Accepted for publication in JCAP

    Journal ref: JCAP 1010:010,2010