Pr10+ as a candidate for a high-accuracy optical clock for tests of fundamental physics
Authors:
S. G. Porsev,
C. Cheung,
M. S. Safronova,
H. Bekker,
N. -H. Rehbehn,
J. R. Crespo Lopez-Urrutia,
S. M. Brewer
Abstract:
We propose In-like Pr10+ as a candidate for the development of a high-accuracy optical clock with high sensitivity to a time variation of the fine-structure constant, (\dot alpha}/alpha, as well as favorable experimental systematics. We calculate its low-lying energy levels by combining the configuration interaction and the coupled cluster method, achieving uncertainties as low as 0.1%, and improv…
▽ More
We propose In-like Pr10+ as a candidate for the development of a high-accuracy optical clock with high sensitivity to a time variation of the fine-structure constant, (\dot alpha}/alpha, as well as favorable experimental systematics. We calculate its low-lying energy levels by combining the configuration interaction and the coupled cluster method, achieving uncertainties as low as 0.1%, and improving previous work. We benchmark these results by comparing our calculations for the (5s^2 5p 2P_1/2) - (5s^2 5p 2P_3/2) transition in Pr10+ with a dedicated measurement and for Pr9+ with a recent experiment, respectively. In addition, we report calculated hyperfine-structure constants for the clock and logic states in Pr10+.
△ Less
Submitted 24 July, 2024;
originally announced July 2024.
-
High-accuracy optical clocks based on group 16-like highly charged ions
Authors:
Saleh O. Allehabi,
S. M. Brewer,
V. A. Dzuba,
V. V. Flambaum,
K. Beloy
Abstract:
We identify laser-accessible transitions in group 16-like highly charged ions as candidates for high-accuracy optical clocks, including S-, Se-, and Te-like systems. For this class of ions, the ground $^{3}P_{J}$ fine structure manifold exhibits irregular (nonmonotonic in $J$) energy ordering for large enough ionization degree. We consider the $|^3P_2\rangle \longleftrightarrow |^3P_0\rangle$ (gro…
▽ More
We identify laser-accessible transitions in group 16-like highly charged ions as candidates for high-accuracy optical clocks, including S-, Se-, and Te-like systems. For this class of ions, the ground $^{3}P_{J}$ fine structure manifold exhibits irregular (nonmonotonic in $J$) energy ordering for large enough ionization degree. We consider the $|^3P_2\rangle \longleftrightarrow |^3P_0\rangle$ (ground to first-excited state) electric quadrupole transition, performing relativistic many-body calculations of several atomic properties important for optical clock development. All ions discussed are suitable for production in small-scale ion sources and lend themselves to sympathetic cooling and quantum-logic readout with singly charged ions.
△ Less
Submitted 18 September, 2022; v1 submitted 27 July, 2022;
originally announced July 2022.
-
Radium Ion Optical Clock
Authors:
C. A. Holliman,
M. Fan,
A. Contractor,
S. M. Brewer,
A. M. Jayich
Abstract:
We report the first operation of a Ra$^{+}$ optical clock, a promising high-performance clock candidate. The clock uses a single trapped $^{226}$Ra$^{+}$ ion and operates on the $7s\ ^2S_{1/2}\rightarrow$ $6d\ ^2D_{5/2}$ electric quadrupole transition. By self-referencing three pairs of symmetric Zeeman transitions, we demonstrate a frequency instability of 1.1$\times10^{-13}$/$\sqrtτ$, where $τ$…
▽ More
We report the first operation of a Ra$^{+}$ optical clock, a promising high-performance clock candidate. The clock uses a single trapped $^{226}$Ra$^{+}$ ion and operates on the $7s\ ^2S_{1/2}\rightarrow$ $6d\ ^2D_{5/2}$ electric quadrupole transition. By self-referencing three pairs of symmetric Zeeman transitions, we demonstrate a frequency instability of 1.1$\times10^{-13}$/$\sqrtτ$, where $τ$ is the averaging time in seconds. The total systematic uncertainty is evaluated to be ${Δν/ ν= 9 \times 10^{-16}}$. Using the clock, we realize the first measurement of the ratio of the $D_{5/2}$ state to the $S_{1/2}$ state Landé $g$-factors: $g_{D}/g_{S}$ = 0.5988053(11). A Ra$^{+}$ optical clock could improve limits on the time variation of the fine structure constant, $\dot α/ α$, in an optical frequency comparison. The ion also has several features that make it a suitable system for a transportable optical clock.
△ Less
Submitted 25 January, 2022; v1 submitted 18 January, 2022;
originally announced January 2022.
-
Quadruply Ionized Barium as a Candidate for a High-Accuracy Optical Clock
Authors:
Kyle Beloy,
Vladimir A. Dzuba,
Samuel M. Brewer
Abstract:
We identify Ba$^{4+}$ (Te-like) as a promising candidate for a high-accuracy optical clock. The lowest-lying electronic states are part of a $^3P_J$ fine structure manifold with anomalous energy ordering, being non-monotonic in $J$. We propose a clock based on the 338.8 THz electric quadrupole transition between the ground ($^3P_2$) and first-excited ($^3P_0$) electronic states. We perform relativ…
▽ More
We identify Ba$^{4+}$ (Te-like) as a promising candidate for a high-accuracy optical clock. The lowest-lying electronic states are part of a $^3P_J$ fine structure manifold with anomalous energy ordering, being non-monotonic in $J$. We propose a clock based on the 338.8 THz electric quadrupole transition between the ground ($^3P_2$) and first-excited ($^3P_0$) electronic states. We perform relativistic many-body calculations to determine relevant properties of this ion. The lifetime of the excited clock state is found to be several seconds, accommodating low statistical uncertainty with a single ion for practical averaging times. The differential static scalar polarizability is found to be small and negative, providing suppressed sensitivity to blackbody radiation while simultaneously allowing cancellation of Stark and excess micromotion shifts. With the exception of Hg$^+$ and Yb$^+$, sensitivity to variation of the fine structure constant is greater than other optical clocks thus far demonstrated.
△ Less
Submitted 23 October, 2020;
originally announced October 2020.
-
Lifetime-Limited Interrogation of Two Independent ${}^{27}\textrm{Al}^{+}$ Clocks Using Correlation Spectroscopy
Authors:
E. R. Clements,
M. E. Kim,
K. Cui,
A. M. Hankin,
S. M. Brewer,
J. Valencia,
J. -S. Chen,
C. W. Chou,
D. R. Leibrandt,
D. B. Hume
Abstract:
Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perfor…
▽ More
Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the $^1S_0\leftrightarrow{}^3P_0$ transition in $^{27}$Al$^+$. By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of $1.12\times10^{15}$ Hz. The observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s $^3P_0$ state lifetime and supports a measurement instability of $(1.8\pm0.5)\times 10^{-16}/\sqrt{τ/\textrm{s}}$ for averaging periods longer than the probe duration when deadtime is negligible.
△ Less
Submitted 4 July, 2020;
originally announced July 2020.
-
Optical Atomic Clock Comparison through Turbulent Air
Authors:
Martha I. Bodine,
Jean-Daniel Deschênes,
Isaac H. Khader,
William C. Swann,
Holly Leopardi,
Kyle Beloy,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Amanda Koepke,
David R. Leibrandt,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Daniele Nicolodi,
Eric Oelker,
Thomas E. Parker
, et al. (10 additional authors not shown)
Abstract:
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the fr…
▽ More
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.
△ Less
Submitted 11 September, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks
Authors:
Boulder Atomic Clock Optical Network,
Collaboration,
:,
Kyle Beloy,
Martha I. Bodine,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Jean-Daniel Deschênes,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Isaac Khader,
Amanda Koepke,
David R. Leibrandt,
Holly Leopardi,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Nathan R. Newbury
, et al. (13 additional authors not shown)
Abstract:
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al…
▽ More
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Measurements of $^{27}$Al$^{+}$ and $^{25}$Mg$^{+}$ magnetic constants for improved ion clock accuracy
Authors:
S. M. Brewer,
J. -S. Chen,
K. Beloy,
A. M. Hankin,
E. R. Clements,
C. W. Chou,
W. F. McGrew,
X. Zhang,
R. J. Fasano,
D. Nicolodi,
H. Leopardi,
T. M. Fortier,
S. A. Diddams,
A. D. Ludlow,
D. J. Wineland,
D. R. Leibrandt,
D. B. Hume
Abstract:
We have measured the quadratic Zeeman coefficient for the ${^{1}S_{0} \leftrightarrow {^{3}P_{0}}}$ optical clock transition in $^{27}$Al$^{+}$, $C_{2}=-71.944(24)$~MHz/T$^{2}$, and the unperturbed hyperfine splitting of the $^{25}$Mg$^{+}$ $^{2}S_{1/2}$ ground electronic state, $ΔW / h = 1~788~762~752.85(13)$~Hz, with improved uncertainties. Both constants are relevant to the evaluation of the…
▽ More
We have measured the quadratic Zeeman coefficient for the ${^{1}S_{0} \leftrightarrow {^{3}P_{0}}}$ optical clock transition in $^{27}$Al$^{+}$, $C_{2}=-71.944(24)$~MHz/T$^{2}$, and the unperturbed hyperfine splitting of the $^{25}$Mg$^{+}$ $^{2}S_{1/2}$ ground electronic state, $ΔW / h = 1~788~762~752.85(13)$~Hz, with improved uncertainties. Both constants are relevant to the evaluation of the $^{27}$Al$^{+}$ quantum-logic clock systematic uncertainty. The measurement of $C_{2}$ is in agreement with a previous measurement and a new calculation at the $1~σ$ level. The measurement of $ΔW$ is in good agreement with a recent measurement and differs from a previously published result by approximately $2σ$. With the improved value for $ΔW$, we deduce an improved value for the nuclear-to-electronic g-factor ratio $g_{I}/g_{J} = 9.299 ~308 ~313(60) \times 10^{-5}$ and the nuclear g-factor for the $^{25}$Mg nucleus $g_{I} = 1.861 ~957 ~82(28) \times 10^{-4}$. Using the values of $C_{2}$ and $ΔW$ presented here, we derive a quadratic Zeeman shift of the $^{27}$Al$^{+}$ quantum-logic clock of $Δν/ ν= -(9241.8 \pm 3.7) \times 10^{-19}$, for a bias magnetic field of $B \approx 0.12$~mT.
△ Less
Submitted 22 May, 2019; v1 submitted 11 March, 2019;
originally announced March 2019.
-
Systematic uncertainty due to background-gas collisions in trapped-ion optical clocks
Authors:
A. M. Hankin,
E. R. Clements,
Y. Huang,
S. M. Brewer,
J. -S. Chen,
C. W. Chou,
D. B. Hume,
D. R. Leibrandt
Abstract:
We describe a framework for calculating the frequency shift and uncertainty of trapped-ion optical atomic clocks caused by background-gas collisions, and apply this framework to an $^{27}$Al$^+$ clock to enable a total fractional systematic uncertainty below $10^{-18}$. For this clock, with 38(19) nPa of room temperature H$_2$ background gas, we find that collisional heating generates a non-therma…
▽ More
We describe a framework for calculating the frequency shift and uncertainty of trapped-ion optical atomic clocks caused by background-gas collisions, and apply this framework to an $^{27}$Al$^+$ clock to enable a total fractional systematic uncertainty below $10^{-18}$. For this clock, with 38(19) nPa of room temperature H$_2$ background gas, we find that collisional heating generates a non-thermal distribution of motional states with a mean time-dilation shift of order $10^{-16}$ at the end of a 150 ms probe, which is not detected by sideband thermometry energy measurements. However, the contribution of collisional heating to the spectroscopy signal is highly suppressed and we calculate the BGC shift to be $-0.6(2.4)\times 10^{-19}$, where the shift is due to collisional heating time-dilation and the uncertainty is dominated by the worst case $\pm π/2$ bound used for collisional phase shift of the $^{27}$Al$^+$ superposition state. We experimentally validate the framework and determine the background-gas pressure in situ using measurements of the rate of collisions that cause reordering of mixed-species ion pairs.
△ Less
Submitted 23 July, 2019; v1 submitted 22 February, 2019;
originally announced February 2019.
-
An $^{27}$Al$^{+}$ quantum-logic clock with systematic uncertainty below $10^{-18}$
Authors:
S. M. Brewer,
J. -S. Chen,
A. M. Hankin,
E. R. Clements,
C. W. Chou,
D. J. Wineland,
D. B. Hume,
D. R. Leibrandt
Abstract:
We describe an optical atomic clock based on quantum-logic spectroscopy of the $^1$S$_0$ $\leftrightarrow$ $^3$P$_0$ transition in $^{27}$Al$^{+}$ with a systematic uncertainty of ${9.4 \times 10^{-19}}$ and a frequency stability of ${1.2\times10^{-15}/\sqrtτ}$. A $^{25}$Mg$^{+}$ ion is simultaneously trapped with the $^{27}$Al$^{+}$ ion and used for sympathetic cooling and state readout. Improvem…
▽ More
We describe an optical atomic clock based on quantum-logic spectroscopy of the $^1$S$_0$ $\leftrightarrow$ $^3$P$_0$ transition in $^{27}$Al$^{+}$ with a systematic uncertainty of ${9.4 \times 10^{-19}}$ and a frequency stability of ${1.2\times10^{-15}/\sqrtτ}$. A $^{25}$Mg$^{+}$ ion is simultaneously trapped with the $^{27}$Al$^{+}$ ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous $^{27}$Al$^{+}$ clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous $^{27}$Al$^{+}$ clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.
△ Less
Submitted 22 May, 2019; v1 submitted 20 February, 2019;
originally announced February 2019.
-
Sympathetic ground state cooling and time-dilation shifts in an $^{27}\text{Al}^+$ optical clock
Authors:
J. -S. Chen,
S. M. Brewer,
C. W. Chou,
D. J. Wineland,
D. R. Leibrandt,
D. B. Hume
Abstract:
We report on Raman sideband cooling of ${^{25}\text{Mg}^+}$ to sympathetically cool the secular modes of motion in a $^{25}\text{Mg}^+$-$^{27}\!\text{Al}^+$ two-ion pair to near the three-dimensional (3D) ground state. The evolution of the Fock-state distribution during the cooling process is studied using a rate-equation simulation, and various heating sources that limit the efficiency of 3D side…
▽ More
We report on Raman sideband cooling of ${^{25}\text{Mg}^+}$ to sympathetically cool the secular modes of motion in a $^{25}\text{Mg}^+$-$^{27}\!\text{Al}^+$ two-ion pair to near the three-dimensional (3D) ground state. The evolution of the Fock-state distribution during the cooling process is studied using a rate-equation simulation, and various heating sources that limit the efficiency of 3D sideband cooling in our system are discussed. We characterize the residual energy and heating rates of all of the secular modes of motion and estimate a secular motion time-dilation shift of ${-(1.9 \pm 0.1)\times 10^{-18}}$ for an ${^{27}\text{Al}^+}$ clock at a typical clock probe duration of $150$ ms. This is a 50-fold reduction in the secular motion time-dilation shift uncertainty in comparison with previous ${^{27}\text{Al}^+}$ clocks.
△ Less
Submitted 16 February, 2017; v1 submitted 17 August, 2016;
originally announced August 2016.
-
Measurement of the Kr XVIII 3d $^2D_{5/2}$ lifetime at low energy in a unitary Penning trap
Authors:
Nicholas D. Guise,
Joseph N. Tan,
Samuel M. Brewer,
Charlotte F. Fischer,
Per Jönsson
Abstract:
A different technique is used to study the radiative decay of a metastable state in multiply ionized atoms. With use of a unitary Penning trap to selectively capture Kr$^{17+}$ ions from an ion source at NIST, the decay of the 3d $^2D_{5/2}$ metastable state is measured in isolation at low energy, without any active cooling. The highly ionized atoms are trapped in the fine structure of the electro…
▽ More
A different technique is used to study the radiative decay of a metastable state in multiply ionized atoms. With use of a unitary Penning trap to selectively capture Kr$^{17+}$ ions from an ion source at NIST, the decay of the 3d $^2D_{5/2}$ metastable state is measured in isolation at low energy, without any active cooling. The highly ionized atoms are trapped in the fine structure of the electronic ground configuration with an energy spread of 4(1) eV, which is narrower than within the ion source by a factor of about 100. By observing the visible 637 nm photon emission of the forbidden transition from the 3d $^2D_{5/2}$ level to the ground state, we measured its radiative lifetime to be $τ=$ 24.48 ms +/- 0.28(stat.) ms +/- 0.14(syst.) ms. Remarkably, various theoretical predictions for this relativistic Rydberg atom are in agreement with our measurement at the 1% level.
△ Less
Submitted 24 April, 2014;
originally announced April 2014.
-
Capture and isolation of highly-charged ions in a unitary Penning trap
Authors:
Samuel M Brewer,
Nicholas D Guise,
Joseph N Tan
Abstract:
We recently used a compact Penning trap to capture and isolate highly-charged ions extracted from an electron beam ion trap (EBIT) at the National Institute of Standards and Technology (NIST). Isolated charge states of highly-stripped argon and neon ions with total charge $Q \geq 10$, extracted at energies of up to $4\times 10^3\,Q$ eV, are captured in a trap with well depths of…
▽ More
We recently used a compact Penning trap to capture and isolate highly-charged ions extracted from an electron beam ion trap (EBIT) at the National Institute of Standards and Technology (NIST). Isolated charge states of highly-stripped argon and neon ions with total charge $Q \geq 10$, extracted at energies of up to $4\times 10^3\,Q$ eV, are captured in a trap with well depths of $\,\approx (4\, {\rm to}\, 12)\,Q$ eV. Here we discuss in detail the process to optimize velocity-tuning, capture, and storage of highly-charged ions in a unitary Penning trap designed to provide easy radial access for atomic or laser beams in charge exchange or spectroscopic experiments, such as those of interest for proposed studies of one-electron ions in Rydberg states or optical transitions of metastable states in multiply-charged ions. Under near-optimal conditions, ions captured and isolated in such rare-earth Penning traps can be characterized by an initial energy distribution that is $\approx$ 60 times narrower than typically found in an EBIT. This reduction in thermal energy is obtained passively, without the application of any active cooling scheme in the ion-capture trap.
△ Less
Submitted 2 December, 2013;
originally announced December 2013.
-
Quantum interference and light polarization effects in unresolvable atomic lines: application to a precise measurement of the 6,7 Li D2 lines
Authors:
Roger C. Brown,
Saijun Wu,
J. V. Porto,
Craig J. Sansonetti,
C. E. Simien,
Samuel M. Brewer,
Joseph N. Tan,
J. D. Gillaspy
Abstract:
We characterize the effect of quantum interference on the line shapes and measured line positions in atomic spectra. These effects, which occur when the excited state splittings are of order the excited state line widths, represent an overlooked but significant systematic effect. We show that excited state interference gives rise to non-Lorenztian line shapes that depend on excitation polarization…
▽ More
We characterize the effect of quantum interference on the line shapes and measured line positions in atomic spectra. These effects, which occur when the excited state splittings are of order the excited state line widths, represent an overlooked but significant systematic effect. We show that excited state interference gives rise to non-Lorenztian line shapes that depend on excitation polarization, and we present expressions for the corrected line shapes. We present spectra of 6,7 Li D lines taken at multiple excitation laser polarizations and show that failure to account for interference changes the inferred line strengths and shifts the line centers by as much as 1 MHz. Using the correct lineshape, we determine absolute optical transition frequencies with an uncertainty of <= 25kHz and provide an improved determination of the difference in mean square nuclear charge radii between 6 Li and 7 Li. This analysis should be important for a number of high resolution spectral measurements that include partially resolvable atomic lines.
△ Less
Submitted 4 July, 2013; v1 submitted 10 December, 2012;
originally announced December 2012.
-
Highly Charged Ions in Rare Earth Permanent Magnet Penning Traps
Authors:
Nicholas D. Guise,
Samuel M. Brewer,
Joseph N. Tan
Abstract:
A newly constructed apparatus at the National Institute of Standards and Technology (NIST) is designed for the isolation, manipulation, and study of highly charged ions. Highly charged ions are produced in the NIST electron-beam ion trap (EBIT), extracted through a beamline that selects a single mass/charge species, then captured in a compact Penning trap. The magnetic field of the trap is generat…
▽ More
A newly constructed apparatus at the National Institute of Standards and Technology (NIST) is designed for the isolation, manipulation, and study of highly charged ions. Highly charged ions are produced in the NIST electron-beam ion trap (EBIT), extracted through a beamline that selects a single mass/charge species, then captured in a compact Penning trap. The magnetic field of the trap is generated by cylindrical NdFeB permanent magnets integrated into its electrodes. In a room-temperature prototype trap with a single NdFeB magnet, species including Ne10+ and N7+ were confined with storage times of order 1 second, showing the potential of this setup for manipulation and spectroscopy of highly charged ions in a controlled environment. Ion capture has since been demonstrated with similar storage times in a more-elaborate Penning trap that integrates two coaxial NdFeB magnets for improved B-field homogeneity. Ongoing experiments utilize a second-generation apparatus that incorporates this two-magnet Penning trap along with a fast time-of-flight MCP detector capable of resolving the charge-state evolution of trapped ions. Holes in the two-magnet Penning trap ring electrode allow for optical and atomic beam access. Possible applications include spectroscopic studies of one-electron ions in Rydberg states, as well as highly charged ions of interest in atomic physics, metrology, astrophysics, and plasma diagnostics.
△ Less
Submitted 13 July, 2012;
originally announced July 2012.
-
Penning traps with unitary architecture for storage of highly charged ions
Authors:
Joseph N. Tan,
Samuel M. Brewer,
Nicholas D. Guise
Abstract:
Penning traps are made extremely compact by embedding rare-earth permanent magnets in the electrode structure. Axially-oriented NdFeB magnets are used in unitary architectures that couple the electric and magnetic components into an integrated structure. We have constructed a two- magnet Penning trap with radial access to enable the use of laser or atomic beams, as well as the collection of light.…
▽ More
Penning traps are made extremely compact by embedding rare-earth permanent magnets in the electrode structure. Axially-oriented NdFeB magnets are used in unitary architectures that couple the electric and magnetic components into an integrated structure. We have constructed a two- magnet Penning trap with radial access to enable the use of laser or atomic beams, as well as the collection of light. An experimental apparatus equipped with ion optics is installed at the NIST electron beam ion trap (EBIT) facility, constrained to fit within 1 meter at the end of a horizontal beamline for transporting highly charged ions. Highly charged ions of neon and argon, extracted with initial energies up to 4000 eV per unit charge, are captured and stored to study the confinement properties of a one-magnet trap and a two-magnet trap. Design considerations and some test results are discussed.
△ Less
Submitted 28 February, 2012;
originally announced February 2012.