-
Optical Atomic Clock Comparison through Turbulent Air
Authors:
Martha I. Bodine,
Jean-Daniel Deschênes,
Isaac H. Khader,
William C. Swann,
Holly Leopardi,
Kyle Beloy,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Amanda Koepke,
David R. Leibrandt,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Daniele Nicolodi,
Eric Oelker,
Thomas E. Parker
, et al. (10 additional authors not shown)
Abstract:
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the fr…
▽ More
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.
△ Less
Submitted 11 September, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks
Authors:
Boulder Atomic Clock Optical Network,
Collaboration,
:,
Kyle Beloy,
Martha I. Bodine,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Jean-Daniel Deschênes,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Isaac Khader,
Amanda Koepke,
David R. Leibrandt,
Holly Leopardi,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Nathan R. Newbury
, et al. (13 additional authors not shown)
Abstract:
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al…
▽ More
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI Limit
Authors:
W. F. McGrew,
X. Zhang,
H. Leopardi,
R. J. Fasano,
D. Nicolodi,
K. Beloy,
J. Yao,
J. A. Sherman,
S. A. Schäffer,
J. Savory,
R. C. Brown,
S. Römisch,
C. W. Oates,
T. E. Parker,
T. M. Fortier,
A. D. Ludlow
Abstract:
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by compari…
▽ More
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by comparing against a primary cesium reference. A key verification of this process can be achieved by performing a loop closure$-$comparing frequency ratios derived from absolute frequency measurements against ratios determined from direct optical comparisons. We measure the $^1$S$_0\!\rightarrow^3$P$_0$ transition of $^{171}$Yb by comparing the clock frequency to an international frequency standard with the aid of a maser ensemble serving as a flywheel oscillator. Our measurements consist of 79 separate runs spanning eight months, and we determine the absolute frequency to be 518 295 836 590 863.71(11) Hz, the uncertainty of which is equivalent to a fractional frequency of $2.1\times10^{-16}$. This absolute frequency measurement, the most accurate reported for any transition, allows us to close the Cs-Yb-Sr-Cs frequency measurement loop at an uncertainty of $<$3$\times10^{-16}$, limited by the current realization of the SI second. We use these measurements to tighten the constraints on variation of the electron-to-proton mass ratio, $μ=m_e/m_p$. Incorporating our measurements with the entire record of Yb and Sr absolute frequency measurements, we infer a coupling coefficient to gravitational potential of $k_\mathrmμ=(-1.9\pm 9.4)\times10^{-7}$ and a drift with respect to time of $\frac{\dotμ}μ=(5.3 \pm 6.5)\times10^{-17}/$yr.
△ Less
Submitted 14 November, 2018;
originally announced November 2018.
-
A null test of General Relativity: New limits on Local Position Invariance and the variation of fundamental constants
Authors:
Neil Ashby,
Thomas E. Parker,
Bijunath R. Patla
Abstract:
We compare the long-term fractional frequency variation of four hydrogen masers that are part of an ensemble of clocks comprising the National Institute of Standards and Technology,(NIST), Boulder, timescale with the fractional frequencies of primary frequency standards operated by leading metrology laboratories in the United States, France, Germany, Italy and the United Kingdom for a period exten…
▽ More
We compare the long-term fractional frequency variation of four hydrogen masers that are part of an ensemble of clocks comprising the National Institute of Standards and Technology,(NIST), Boulder, timescale with the fractional frequencies of primary frequency standards operated by leading metrology laboratories in the United States, France, Germany, Italy and the United Kingdom for a period extending more than 14 years. The measure of the assumed variation of non-gravitational interaction,(LPI parameter, $β$)---within the atoms of H and Cs---over time as the earth orbits the sun, has been constrained to $β=(2.2 \pm 2.5)\times 10^{-7}$, a factor of two improvement over previous estimates. Using our results together with the previous best estimates of $β$ based on Rb vs. Cs, and Rb vs. H comparisons, we impose the most stringent limits to date on the dimensionless coupling constants that relate the variation of fundamental constants such as the fine-structure constant and the scaled quark mass with strong(QCD) interaction to the variation in the local gravitational potential. For any metric theory of gravity $β=0$.
△ Less
Submitted 20 February, 2018; v1 submitted 30 June, 2017;
originally announced June 2017.
-
Precision measurement of the speed of propagation of neutrinos using the MINOS detectors
Authors:
P. Adamson,
I. Anghel,
N. Ashby,
A. Aurisano,
G. Barr,
M. Bishai,
A. Blake,
G. J. Bock,
D. Bogert,
R. Bumgarner,
S. V. Cao,
C. M. Castromonte,
S. Childress,
J. A. B. Coelho,
L. Corwin,
D. Cronin-Hennessy,
J. K. de Jong,
A. V. Devan,
N. E. Devenish,
M. V. Diwan,
C. O. Escobar,
J. J. Evans,
E. Falk,
G. J. Feldman,
B. Fonville
, et al. (98 additional authors not shown)
Abstract:
We report a two-detector measurement of the propagation speed of neutrinos over a baseline of 734 km. The measurement was made with the NuMI beam at Fermilab between the near and far MINOS detectors. The fractional difference between the neutrino speed and the speed of light is determined to be $(v/c-1) = (1.0 \pm 1.1) \times 10^{-6}$, consistent with relativistic neutrinos.
We report a two-detector measurement of the propagation speed of neutrinos over a baseline of 734 km. The measurement was made with the NuMI beam at Fermilab between the near and far MINOS detectors. The fractional difference between the neutrino speed and the speed of light is determined to be $(v/c-1) = (1.0 \pm 1.1) \times 10^{-6}$, consistent with relativistic neutrinos.
△ Less
Submitted 21 August, 2015; v1 submitted 15 July, 2015;
originally announced July 2015.
-
Spin-1/2 Optical Lattice Clock
Authors:
N. D. Lemke,
A. D. Ludlow,
Z. W. Barber,
T. M. Fortier,
S. A. Diddams,
Y. Jiang,
S. R. Jefferts,
T. P. Heavner,
T. E. Parker,
C. W. Oates
Abstract:
We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of $3.4 \times 10^{-16}$, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock tran…
▽ More
We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of $3.4 \times 10^{-16}$, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.
△ Less
Submitted 24 July, 2009; v1 submitted 5 June, 2009;
originally announced June 2009.
-
The absolute frequency of the 87Sr optical clock transition
Authors:
Gretchen K. Campbell,
Andrew D. Ludlow,
Sebastian Blatt,
Jan W. Thomsen,
Michael J. Martin,
Marcio H. G. de Miranda,
Tanya Zelevinsky,
Martin M. Boyd,
Jun Ye,
Scott A. Diddams,
Thomas P. Heavner,
Thomas E. Parker,
Steven R. Jefferts
Abstract:
The absolute frequency of the 1S0-3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6x10-16 represents one of the most accurate measurements of an atomic transition frequency to date. After a detailed study of systematic effects, which reduced the total systematic uncertainty of the Sr lattice c…
▽ More
The absolute frequency of the 1S0-3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6x10-16 represents one of the most accurate measurements of an atomic transition frequency to date. After a detailed study of systematic effects, which reduced the total systematic uncertainty of the Sr lattice clock to 1.5x10-16, the clock frequency is measured against a hydrogen maser which is simultaneously calibrated to the US primary frequency standard, the NIST Cs fountain clock, NIST-F1. The comparison is made possible using a femtosecond laser based optical frequency comb to phase coherently connect the optical and microwave spectral regions and by a 3.5 km fiber transfer scheme to compare the remotely located clock signals.
△ Less
Submitted 28 April, 2008;
originally announced April 2008.
-
Testing the stability of fundamental constants with the 199Hg+ single-ion optical clock
Authors:
S. Bize,
S. A. Diddams,
U. Tanaka,
C. E. Tanner,
W. H. Oskay,
R. E. Drullinger,
T. E. Parker,
T. P. Heavner,
S. R. Jefferts,
L. Hollberg,
W. M. Itano,
D. J. Wineland,
J. C. Bergquist
Abstract:
Over a two-year duration, we have compared the frequency of the 199Hg+ 5d106s 2S 1/2 (F=0)<-> 5d9 6s2 2D 5/2 (F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/- 7 10^-15 / yr (1 sigma uncertai…
▽ More
Over a two-year duration, we have compared the frequency of the 199Hg+ 5d106s 2S 1/2 (F=0)<-> 5d9 6s2 2D 5/2 (F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/- 7 10^-15 / yr (1 sigma uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of g(Cs) m_e / m_p alpha^6.0 at the same level.
△ Less
Submitted 30 December, 2002;
originally announced December 2002.