-
Excess noise and photo-induced effects in highly reflective crystalline mirror coatings
Authors:
Jialiang Yu,
Dhruv Kedar,
Sebastian Häfner,
Thomas Legero,
Fritz Riehle,
Sofia Herbers,
Daniele Nicolodi,
Chun Yu Ma,
John M. Robinson,
Eric Oelker,
Jun Ye,
Uwe Sterr
Abstract:
Thermodynamically induced length fluctuations of high-reflectivity mirror coatings put a fundamental limit on sensitivity and stability of precision optical interferometers like gravitational wave detectors and ultra-stable lasers. The main contribution - Brownian thermal noise - is related to the mechanical loss of the coating material. Owing to their low mechanical losses, Al\textsubscript{0.92}…
▽ More
Thermodynamically induced length fluctuations of high-reflectivity mirror coatings put a fundamental limit on sensitivity and stability of precision optical interferometers like gravitational wave detectors and ultra-stable lasers. The main contribution - Brownian thermal noise - is related to the mechanical loss of the coating material. Owing to their low mechanical losses, Al\textsubscript{0.92}Ga\textsubscript{0.08}As/GaAs crystalline mirror coatings are expected to reduce this limit. At room temperature they have demonstrated lower Brownian thermal noise than with conventional amorphous coatings. %However, no detailed study on the noise constituents from these coatings in optical interferometers has been conducted. We present a detailed study on the spatial and temporal noise properties of such coatings by using them in two independent cryogenic silicon optical Fabry-Perot resonators operated at 4 K, 16 K and 124 K. We confirm the expected low Brownian thermal noise, but also discover two new noise sources that exceed the Brownian noise: birefringent noise that can be canceled via polarization averaging and global excess noise (10 dB above Brownian noise). These new noise contributions are a barrier to improving ultra-stable lasers and the related performance of atomic clocks, and potentially limit the sensitivity of third-generation gravitational wave detectors. Hence, they must be considered carefully in precision interferometry experiments using similar coatings based on semiconductor materials.
△ Less
Submitted 30 October, 2023; v1 submitted 26 October, 2022;
originally announced October 2022.
-
Frequency stability of cryogenic silicon cavities with semiconductor crystalline coatings
Authors:
Dhruv Kedar,
Jialiang Yu,
Eric Oelker,
Alexander Staron,
William R. Milner,
John M. Robinson,
Thomas Legero,
Fritz Riehle,
Uwe Sterr,
Jun Ye
Abstract:
State-of-the-art optical oscillators employing cryogenic reference cavities are limited in performance by the Brownian thermal noise associated with the mechanical dissipation of the mirror coatings. Recently, crystalline Al$_{1-x}$Ga$_{x}$As/GaAs coatings have emerged as a promising candidate for improved coating thermal noise. We present measurements of the frequency noise of two fully crystalli…
▽ More
State-of-the-art optical oscillators employing cryogenic reference cavities are limited in performance by the Brownian thermal noise associated with the mechanical dissipation of the mirror coatings. Recently, crystalline Al$_{1-x}$Ga$_{x}$As/GaAs coatings have emerged as a promising candidate for improved coating thermal noise. We present measurements of the frequency noise of two fully crystalline cryogenic reference cavities with Al$_{0.92}$Ga$_{0.08}$As/GaAs optical coatings. We report on previously unmeasured birefringent noise associated with anti-correlated frequency fluctuations between the polarization modes of the crystalline coatings, and identify variables that affect its magnitude. Comparing the birefringent noise between the two cryogenic reference cavities reveals a phenomenological set of scalings with intracavity power and mode area. We implement an interrogation scheme that cancels this noise by simultaneous probing of both polarization modes. The residual noise remaining after this cancellation is larger than both cavities thermal noise limits, but still lower than the instabilities previously measured on equivalent resonators with dielectric coatings. Though the source of these novel noise mechanisms is unclear, we demonstrate that crystalline coatings can provide stability and sensitivity competitive with resonators employing dielectric coatings.
△ Less
Submitted 26 October, 2022;
originally announced October 2022.
-
Resolving the gravitational redshift within a millimeter atomic sample
Authors:
Tobias Bothwell,
Colin J. Kennedy,
Alexander Aeppli,
Dhruv Kedar,
John M. Robinson,
Eric Oelker,
Alexander Staron,
Jun Ye
Abstract:
Einstein's theory of general relativity states that clocks at different gravitational potentials tick at different rates - an effect known as the gravitational redshift. As fundamental probes of space and time, atomic clocks have long served to test this prediction at distance scales from 30 centimeters to thousands of kilometers. Ultimately, clocks will study the union of general relativity and q…
▽ More
Einstein's theory of general relativity states that clocks at different gravitational potentials tick at different rates - an effect known as the gravitational redshift. As fundamental probes of space and time, atomic clocks have long served to test this prediction at distance scales from 30 centimeters to thousands of kilometers. Ultimately, clocks will study the union of general relativity and quantum mechanics once they become sensitive to the finite wavefunction of quantum objects oscillating in curved spacetime. Towards this regime, we measure a linear frequency gradient consistent with the gravitational redshift within a single millimeter scale sample of ultracold strontium. Our result is enabled by improving the fractional frequency measurement uncertainty by more than a factor of 10, now reaching 7.6$\times 10^{-21}$. This heralds a new regime of clock operation necessitating intra-sample corrections for gravitational perturbations.
△ Less
Submitted 24 September, 2021;
originally announced September 2021.
-
Thermal noise and mechanical loss of SiO$_2$/Ta$_2$O$_5$ optical coatings at cryogenic temperatures
Authors:
John M Robinson,
Eric Oelker,
William R Milner,
Dhruv Kedar,
Wei Zhang,
Thomas Legero,
Dan G Matei,
Sebastian Hafner,
Fritz Riehle,
Uwe Sterr,
Jun Ye
Abstract:
Mechanical loss of dielectric mirror coatings sets fundamental limits for both gravitational wave detectors and cavity-stabilized optical local oscillators for atomic clocks. Two approaches are used to determine the mechanical loss: ringdown measurements of the coating quality factor and direct measurement of the coating thermal noise. Here we report a systematic study of the mirror thermal noise…
▽ More
Mechanical loss of dielectric mirror coatings sets fundamental limits for both gravitational wave detectors and cavity-stabilized optical local oscillators for atomic clocks. Two approaches are used to determine the mechanical loss: ringdown measurements of the coating quality factor and direct measurement of the coating thermal noise. Here we report a systematic study of the mirror thermal noise from room temperature to 4 K by operating reference cavities at these temperatures. The directly measured thermal noise is used to extract the corresponding mechanical loss for SiO$_2$/Ta$_2$O$_5$ coatings, which are compared with previously reported values.
△ Less
Submitted 10 November, 2020;
originally announced November 2020.
-
Precision Metrology Meets Cosmology: Improved Constraints on Ultralight Dark Matter from Atom-Cavity Frequency Comparisons
Authors:
Colin J. Kennedy,
Eric Oelker,
John M. Robinson,
Tobias Bothwell,
Dhruv Kedar,
William R. Milner,
G. Edward Marti,
Andrei Derevianko,
Jun Ye
Abstract:
We conduct frequency comparisons between a state-of-the-art strontium optical lattice clock, a cryogenic crystalline silicon cavity, and a hydrogen maser to set new bounds on the coupling of ultralight dark matter to Standard Model particles and fields in the mass range of $10^{-16}$ $-$ $10^{-21}$ eV. The key advantage of this two-part ratio comparison is the differential sensitivities to time va…
▽ More
We conduct frequency comparisons between a state-of-the-art strontium optical lattice clock, a cryogenic crystalline silicon cavity, and a hydrogen maser to set new bounds on the coupling of ultralight dark matter to Standard Model particles and fields in the mass range of $10^{-16}$ $-$ $10^{-21}$ eV. The key advantage of this two-part ratio comparison is the differential sensitivities to time variation of both the fine-structure constant and the electron mass, achieving a substantially improved limit on the moduli of ultralight dark matter, particularly at higher masses than typical atomic spectroscopic results. Furthermore, we demonstrate an extension of the search range to even higher masses by use of dynamical decoupling techniques. These results highlight the importance of using the best performing atomic clocks for fundamental physics applications as all-optical timescales are increasingly integrated with, and will eventually supplant, existing microwave timescales.
△ Less
Submitted 20 August, 2020;
originally announced August 2020.
-
Optical Atomic Clock Comparison through Turbulent Air
Authors:
Martha I. Bodine,
Jean-Daniel Deschênes,
Isaac H. Khader,
William C. Swann,
Holly Leopardi,
Kyle Beloy,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Amanda Koepke,
David R. Leibrandt,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Daniele Nicolodi,
Eric Oelker,
Thomas E. Parker
, et al. (10 additional authors not shown)
Abstract:
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the fr…
▽ More
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.
△ Less
Submitted 11 September, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks
Authors:
Boulder Atomic Clock Optical Network,
Collaboration,
:,
Kyle Beloy,
Martha I. Bodine,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Jean-Daniel Deschênes,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Isaac Khader,
Amanda Koepke,
David R. Leibrandt,
Holly Leopardi,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Nathan R. Newbury
, et al. (13 additional authors not shown)
Abstract:
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al…
▽ More
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
A tweezer clock with half-minute atomic coherence at optical frequencies and high relative stability
Authors:
Aaron W. Young,
William J. Eckner,
William R. Milner,
Dhruv Kedar,
Matthew A. Norcia,
Eric Oelker,
Nathan Schine,
Jun Ye,
Adam M. Kaufman
Abstract:
The preparation of large, low-entropy, highly coherent ensembles of identical quantum systems is foundational for many studies in quantum metrology, simulation, and information. Here, we realize these features by leveraging the favorable properties of tweezer-trapped alkaline-earth atoms while introducing a new, hybrid approach to tailoring optical potentials that balances scalability, high-fideli…
▽ More
The preparation of large, low-entropy, highly coherent ensembles of identical quantum systems is foundational for many studies in quantum metrology, simulation, and information. Here, we realize these features by leveraging the favorable properties of tweezer-trapped alkaline-earth atoms while introducing a new, hybrid approach to tailoring optical potentials that balances scalability, high-fidelity state preparation, site-resolved readout, and preservation of atomic coherence. With this approach, we achieve trapping and optical clock excited-state lifetimes exceeding $ 40 $ seconds in ensembles of approximately $ 150 $ atoms. This leads to half-minute-scale atomic coherence on an optical clock transition, corresponding to quality factors well in excess of $10^{16}$. These coherence times and atom numbers reduce the effect of quantum projection noise to a level that is on par with leading atomic systems, yielding a relative fractional frequency stability of $5.2(3)\times10^{-17}~(τ/s)^{-1/2}$ for synchronous clock comparisons between sub-ensembles within the tweezer array. When further combined with the microscopic control and readout available in this system, these results pave the way towards long-lived engineered entanglement on an optical clock transition in tailored atom arrays.
△ Less
Submitted 23 June, 2020; v1 submitted 13 April, 2020;
originally announced April 2020.
-
Demonstration of a time scale based on a stable optical carrier
Authors:
William R. Milner,
John M. Robinson,
Colin J. Kennedy,
Tobias Bothwell,
Dhruv Kedar,
Dan G. Matei,
Thomas Legero,
Uwe Sterr,
Fritz Riehle,
Holly Leopardi,
Tara M. Fortier,
Jeffrey A. Sherman,
Judah Levine,
Jian Yao,
Jun Ye,
Eric Oelker
Abstract:
We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even wh…
▽ More
We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even when they are steered to optical frequency standards. Our analysis indicates that this time scale is capable of reaching a stability below $1\times10^{-17}$ after a few months of averaging, making timekeeping at the $10^{-18}$ level a realistic prospect.
△ Less
Submitted 6 July, 2019;
originally announced July 2019.
-
JILA SrI Optical Lattice Clock with Uncertainty of $2.0 \times 10^{-18}$
Authors:
Tobias Bothwell,
Dhruv Kedar,
Eric Oelker,
John M. Robinson,
Sarah L. Bromley,
Weston L. Tew,
Jun Ye,
Colin J. Kennedy
Abstract:
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical systematic uncertainty compared to the previous strontium accuracy record set by the JILA SrII optical lattice clock (OLC) at $2.1 \times 10^{-18}$. This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reducti…
▽ More
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical systematic uncertainty compared to the previous strontium accuracy record set by the JILA SrII optical lattice clock (OLC) at $2.1 \times 10^{-18}$. This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reduction in systematic uncertainty to $2.0 \times 10^{-18}$. A seven-fold improvement in clock stability, reaching $4.8 \times 10^{-17}/\sqrtτ$ for an averaging time $τ$ in seconds, allows the clock to average to its systematic uncertainty in under 10 minutes. We improve the systematic uncertainty budget in several important ways. This includes a novel scheme for taming blackbody radiation-induced frequency shifts through active stabilization and characterization of the thermal environment, inclusion of higher-order terms in the lattice light shift, and updated atomic coefficients. Along with careful control of other systematic effects, we achieve low temporal drift of systematic offsets and high uptime of the clock. We additionally present an improved evaluation of the second order Zeeman coefficient that is applicable to all Sr optical lattice clocks. These improvements in performance have enabled several important studies including frequency ratio measurements through the Boulder Area Clock Optical Network (BACON), a high precision comparison with the JILA 3D lattice clock, a demonstration of a new all-optical time scale combining SrI and a cryogenic silicon cavity, and a high sensitivity search for ultralight scalar dark matter.
△ Less
Submitted 13 June, 2019;
originally announced June 2019.
-
Seconds-scale coherence in a tweezer-array optical clock
Authors:
Matthew A. Norcia,
Aaron W. Young,
William J. Eckner,
Eric Oelker,
Jun Ye,
Adam M. Kaufman
Abstract:
Optical clocks based on atoms and ions achieve exceptional precision and accuracy, with applications to relativistic geodesy, tests of relativity, and searches for dark matter. Achieving such performance requires balancing competing desirable features, including a high particle number, isolation of atoms from collisions, insensitivity to motional effects, and high duty-cycle operation. Here we dem…
▽ More
Optical clocks based on atoms and ions achieve exceptional precision and accuracy, with applications to relativistic geodesy, tests of relativity, and searches for dark matter. Achieving such performance requires balancing competing desirable features, including a high particle number, isolation of atoms from collisions, insensitivity to motional effects, and high duty-cycle operation. Here we demonstrate a new platform based on arrays of ultracold strontium atoms confined within optical tweezers that realizes a novel combination of these features by providing a scalable platform for isolated atoms that can be interrogated multiple times. With this tweezer-array clock, we achieve greater than 3 second coherence times and record duty cycles up to 96%, as well as stability commensurate with leading platforms. By using optical tweezer arrays --- a proven platform for the controlled creation of entanglement through microscopic control --- this work further promises a new path toward combining entanglement enhanced sensitivities with the most precise optical clock transitions.
△ Less
Submitted 24 July, 2019; v1 submitted 24 April, 2019;
originally announced April 2019.
-
Optical clock intercomparison with $6\times 10^{-19}$ precision in one hour
Authors:
E. Oelker,
R. B. Hutson,
C. J. Kennedy,
L. Sonderhouse,
T. Bothwell,
A. Goban,
D. Kedar,
C. Sanner,
J. M. Robinson,
G. E. Marti,
D. G. Matei,
T. Legero,
M. Giunta,
R. Holzwarth,
F. Riehle,
U. Sterr,
J. Ye
Abstract:
Improvements in atom-light coherence are foundational to progress in quantum information science, quantum optics, and precision metrology. Optical atomic clocks require local oscillators with exceptional optical coherence due to the challenge of performing spectroscopy on their ultra-narrow linewidth clock transitions. Advances in laser stabilization have thus enabled rapid progress in clock preci…
▽ More
Improvements in atom-light coherence are foundational to progress in quantum information science, quantum optics, and precision metrology. Optical atomic clocks require local oscillators with exceptional optical coherence due to the challenge of performing spectroscopy on their ultra-narrow linewidth clock transitions. Advances in laser stabilization have thus enabled rapid progress in clock precision. A new class of ultrastable lasers based on cryogenic silicon reference cavities has recently demonstrated the longest optical coherence times to date. In this work we utilize such a local oscillator, along with a state-of-the-art frequency comb for coherence transfer, with two Sr optical lattice clocks to achieve an unprecedented level of clock stability. Through an anti-synchronous comparison, the fractional instability of both clocks is assessed to be $4.8\times 10^{-17}/\sqrtτ$ for an averaging time $τ$ in seconds. Synchronous interrogation reveals a quantum projection noise dominated instability of $3.5(2)\times10^{-17}/\sqrtτ$, resulting in a precision of $5.8(3)\times 10^{-19}$ after a single hour of averaging. The ability to measure sub-$10^{-18}$ level frequency shifts in such short timescales will impact a wide range of applications for clocks in quantum sensing and fundamental physics. For example, this precision allows one to resolve the gravitational red shift from a 1 cm elevation change in only 20 minutes.
△ Less
Submitted 7 February, 2019;
originally announced February 2019.
-
Crystalline optical cavity at 4 K with thermal noise limited instability and ultralow drift
Authors:
John M. Robinson,
Eric Oelker,
William R. Milner,
Wei Zhang,
Thomas Legero,
Dan G. Matei,
Fritz Riehle,
Uwe Sterr,
Jun Ye
Abstract:
Crystalline optical cavities are the foundation of today's state-of-the-art ultrastable lasers. Building on our previous silicon cavity effort, we now achieve the fundamental thermal noise-limited stability for a 6 cm long silicon cavity cooled to 4 Kelvin, reaching $6.5\times10^{-17}$ from 0.8 to 80 seconds. We also report for the first time a clear linear dependence of the cavity frequency drift…
▽ More
Crystalline optical cavities are the foundation of today's state-of-the-art ultrastable lasers. Building on our previous silicon cavity effort, we now achieve the fundamental thermal noise-limited stability for a 6 cm long silicon cavity cooled to 4 Kelvin, reaching $6.5\times10^{-17}$ from 0.8 to 80 seconds. We also report for the first time a clear linear dependence of the cavity frequency drift on the incident optical power. The lowest fractional frequency drift of $-3\times10^{-19}$/s is attained at a transmitted power of 40 nW, with an extrapolated drift approaching zero in the absence of optical power. These demonstrations provide a promising direction to reach a new performance domain for stable lasers, with stability better than $1\times10^{-17}$ and fractional linear drift below $1\times10^{-19}$/s.
△ Less
Submitted 6 December, 2018;
originally announced December 2018.
-
An ultrastable silicon cavity in a continuously operating closed-cycle cryostat at 4 K
Authors:
W. Zhang,
J. M. Robinson,
L. Sonderhouse,
E. Oelker,
C. Benko,
J. L. Hall,
T. Legero,
D. G. Matei,
F. Riehle,
U. Sterr,
J. Ye
Abstract:
We report on a laser locked to a silicon cavity operating continuously at 4 K with $1 \times 10^{-16}$ instability and a median linewidth of 17 mHz at 1542 nm. This is a ten-fold improvement in short-term instability, and a $10^4$ improvement in linewidth, over previous sub-10 K systems. Operating at low temperatures reduces the thermal noise floor, and thus is advantageous toward reaching an inst…
▽ More
We report on a laser locked to a silicon cavity operating continuously at 4 K with $1 \times 10^{-16}$ instability and a median linewidth of 17 mHz at 1542 nm. This is a ten-fold improvement in short-term instability, and a $10^4$ improvement in linewidth, over previous sub-10 K systems. Operating at low temperatures reduces the thermal noise floor, and thus is advantageous toward reaching an instability of $10^{-18}$, a long-sought goal of the optical clock community. The performance of this system demonstrates the technical readiness for the development of the next generation of ultrastable lasers that operate with ultranarrow linewidth and long-term stability without user intervention.
△ Less
Submitted 5 November, 2017; v1 submitted 17 August, 2017;
originally announced August 2017.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Audio-band frequency-dependent squeezing
Authors:
Eric Oelker,
Tomoki Isogai,
John Miller,
Maggie Tse,
Lisa Barsotti,
Nergis Mavalvala,
Matthew Evans
Abstract:
Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. However, optomechanical interactions dictate that the vacuum's squeezed quadrature mus…
▽ More
Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. However, optomechanical interactions dictate that the vacuum's squeezed quadrature must rotate by 90 degrees around 50Hz. Here we use a 2-m-long, high-finesse optical resonator to produce frequency-dependent rotation around 1.2kHz. This demonstration of audio-band frequency-dependent squeezing uses technology and methods that are scalable to the required rotation frequency, heralding application of the technique in future gravitational-wave detectors.
△ Less
Submitted 18 August, 2015;
originally announced August 2015.