Ultrastable lasers: investigations of crystalline mirrors and closed cycle cooling at 124 K
Authors:
C. Y. Ma,
J. Yu,
T. Legero,
S. Herbers,
D. Nicolodi,
M. Kempkes,
F. Riehle,
D. Kedar,
J. M. Robinson,
J. Ye,
U. Sterr
Abstract:
We have investigated crystalline AlGaAs/GaAs optical coatings with three ultra-stable cavities operating at 4 K, 16 K, 124 K and 297 K. The response of the resonance frequencies of cavities to variations in optical power indicates effects beyond the photo-thermo-optic effect observed in dielectric coatings. These effects are strongly dependent on the intensity of the intracavity light at 1.5~\text…
▽ More
We have investigated crystalline AlGaAs/GaAs optical coatings with three ultra-stable cavities operating at 4 K, 16 K, 124 K and 297 K. The response of the resonance frequencies of cavities to variations in optical power indicates effects beyond the photo-thermo-optic effect observed in dielectric coatings. These effects are strongly dependent on the intensity of the intracavity light at 1.5~\textmu m. When the rear side of the mirrors is illuminated with external light, we observe a prominent photo-modified birefringence for photon energies above the GaAs bandgap, which points to a possible mechanism relating our observations to the semiconductor properties of the coatings. Separately, we also present a low maintenance evolution of our 124 K silicon cavity system where the liquid nitrogen based cooling system is replaced with closed cycle cooling from a pulse-tube cryo-cooler.
△ Less
Submitted 4 April, 2024; v1 submitted 3 April, 2024;
originally announced April 2024.
-
Substrate-transferred GaAs/AlGaAs crystalline coatings for gravitational-wave detectors: A review of the state of the art
Authors:
G. D. Cole,
S. Ballmer,
G. Billingsley,
S. B. Cataño-Lopez,
M. Fejer,
P. Fritschel,
A. M. Gretarsson,
G. M. Harry,
D. Kedar,
T. Legero,
C. Makarem,
S. D. Penn,
D. Reitze,
J. Steinlechner,
U. Sterr,
S. Tanioka,
G. -W. Truong,
J. Ye,
J. Yu
Abstract:
In this Perspective we summarize the status of technological development for large-area and low-noise substrate-transferred GaAs/AlGaAs (AlGaAs) crystalline coatings for interferometric gravitational-wave (GW) detectors. These topics were originally presented in a workshop† bringing together members of the GW community from the laser interferometer gravitational-wave observatory (LIGO), Virgo, and…
▽ More
In this Perspective we summarize the status of technological development for large-area and low-noise substrate-transferred GaAs/AlGaAs (AlGaAs) crystalline coatings for interferometric gravitational-wave (GW) detectors. These topics were originally presented in a workshop† bringing together members of the GW community from the laser interferometer gravitational-wave observatory (LIGO), Virgo, and KAGRA collaborations, along with scientists from the precision optical metrology community, and industry partners with extensive expertise in the manufacturing of said coatings. AlGaAs-based crystalline coatings present the possibility of GW observatories having significantly greater range than current systems employing ion-beam sputtered mirrors. Given the low thermal noise of AlGaAs at room temperature, GW detectors could realize these significant sensitivity gains, while potentially avoiding cryogenic operation. However, the development of large-area AlGaAs coatings presents unique challenges. Herein, we describe recent research and development efforts relevant to crystalline coatings, covering characterization efforts on novel noise processes, as well as optical metrology on large-area (~10 cm diameter) mirrors. We further explore options to expand the maximum coating diameter to 20 cm and beyond, forging a path to produce low-noise AlGaAs mirrors amenable to future GW detector upgrades, while noting the unique requirements and prospective experimental testbeds for these novel materials.
△ Less
Submitted 6 January, 2023;
originally announced January 2023.
-
Excess noise and photo-induced effects in highly reflective crystalline mirror coatings
Authors:
Jialiang Yu,
Dhruv Kedar,
Sebastian Häfner,
Thomas Legero,
Fritz Riehle,
Sofia Herbers,
Daniele Nicolodi,
Chun Yu Ma,
John M. Robinson,
Eric Oelker,
Jun Ye,
Uwe Sterr
Abstract:
Thermodynamically induced length fluctuations of high-reflectivity mirror coatings put a fundamental limit on sensitivity and stability of precision optical interferometers like gravitational wave detectors and ultra-stable lasers. The main contribution - Brownian thermal noise - is related to the mechanical loss of the coating material. Owing to their low mechanical losses, Al\textsubscript{0.92}…
▽ More
Thermodynamically induced length fluctuations of high-reflectivity mirror coatings put a fundamental limit on sensitivity and stability of precision optical interferometers like gravitational wave detectors and ultra-stable lasers. The main contribution - Brownian thermal noise - is related to the mechanical loss of the coating material. Owing to their low mechanical losses, Al\textsubscript{0.92}Ga\textsubscript{0.08}As/GaAs crystalline mirror coatings are expected to reduce this limit. At room temperature they have demonstrated lower Brownian thermal noise than with conventional amorphous coatings. %However, no detailed study on the noise constituents from these coatings in optical interferometers has been conducted. We present a detailed study on the spatial and temporal noise properties of such coatings by using them in two independent cryogenic silicon optical Fabry-Perot resonators operated at 4 K, 16 K and 124 K. We confirm the expected low Brownian thermal noise, but also discover two new noise sources that exceed the Brownian noise: birefringent noise that can be canceled via polarization averaging and global excess noise (10 dB above Brownian noise). These new noise contributions are a barrier to improving ultra-stable lasers and the related performance of atomic clocks, and potentially limit the sensitivity of third-generation gravitational wave detectors. Hence, they must be considered carefully in precision interferometry experiments using similar coatings based on semiconductor materials.
△ Less
Submitted 30 October, 2023; v1 submitted 26 October, 2022;
originally announced October 2022.
-
Frequency stability of cryogenic silicon cavities with semiconductor crystalline coatings
Authors:
Dhruv Kedar,
Jialiang Yu,
Eric Oelker,
Alexander Staron,
William R. Milner,
John M. Robinson,
Thomas Legero,
Fritz Riehle,
Uwe Sterr,
Jun Ye
Abstract:
State-of-the-art optical oscillators employing cryogenic reference cavities are limited in performance by the Brownian thermal noise associated with the mechanical dissipation of the mirror coatings. Recently, crystalline Al$_{1-x}$Ga$_{x}$As/GaAs coatings have emerged as a promising candidate for improved coating thermal noise. We present measurements of the frequency noise of two fully crystalli…
▽ More
State-of-the-art optical oscillators employing cryogenic reference cavities are limited in performance by the Brownian thermal noise associated with the mechanical dissipation of the mirror coatings. Recently, crystalline Al$_{1-x}$Ga$_{x}$As/GaAs coatings have emerged as a promising candidate for improved coating thermal noise. We present measurements of the frequency noise of two fully crystalline cryogenic reference cavities with Al$_{0.92}$Ga$_{0.08}$As/GaAs optical coatings. We report on previously unmeasured birefringent noise associated with anti-correlated frequency fluctuations between the polarization modes of the crystalline coatings, and identify variables that affect its magnitude. Comparing the birefringent noise between the two cryogenic reference cavities reveals a phenomenological set of scalings with intracavity power and mode area. We implement an interrogation scheme that cancels this noise by simultaneous probing of both polarization modes. The residual noise remaining after this cancellation is larger than both cavities thermal noise limits, but still lower than the instabilities previously measured on equivalent resonators with dielectric coatings. Though the source of these novel noise mechanisms is unclear, we demonstrate that crystalline coatings can provide stability and sensitivity competitive with resonators employing dielectric coatings.
△ Less
Submitted 26 October, 2022;
originally announced October 2022.
-
A transportable clock laser system with an instability of $1.6 \times 10^{-16}$
Authors:
Sofia Herbers,
Sebastian Häfner,
Sören Dörscher,
Tim Lücke,
Uwe Sterr,
Christian Lisdat
Abstract:
We present a transportable ultra-stable clock laser system based on a Fabry-Pérot cavity with crystalline Al$_{0.92}$Ga$_{0.08}$As/GaAs mirror coatings, fused silica (FS) mirror substrates and a 20~cm-long ultra-low expansion (ULE\textsuperscript{\textregistered}) glass spacer with a predicted thermal noise floor of $\mathrm{mod}\,σ_\mathrm{y} = 7 \times 10^{-17}$ in modified Allan deviation at on…
▽ More
We present a transportable ultra-stable clock laser system based on a Fabry-Pérot cavity with crystalline Al$_{0.92}$Ga$_{0.08}$As/GaAs mirror coatings, fused silica (FS) mirror substrates and a 20~cm-long ultra-low expansion (ULE\textsuperscript{\textregistered}) glass spacer with a predicted thermal noise floor of $\mathrm{mod}\,σ_\mathrm{y} = 7 \times 10^{-17}$ in modified Allan deviation at one second averaging time. The cavity has a cylindrical shape and is mounted at ten points. Its measured sensitivity of the fractional frequency to acceleration for the three Cartesian directions are $2(1) \times 10^{-12}$/(ms$^{-2}$), $3(3) \times 10^{-12}$/(ms$^{-2}$) and $3(1) \times 10^{-12}$/(ms$^{-2}$), which belong to the lowest acceleration sensitivities published for transportable systems. The laser system's instability reaches down to $\mathrm{mod}\,σ_\mathrm{y} = 1.6 \times 10^{-16}$
△ Less
Submitted 20 October, 2022; v1 submitted 18 July, 2022;
originally announced July 2022.
-
Ultimate stability of active optical frequency standards
Authors:
Georgy A. Kazakov,
Swadheen Dubey,
Anna Bychek,
Uwe Sterr,
Marcin Bober,
Michał Zawada
Abstract:
Active optical frequency standards provide interesting alternatives to their passive counterparts. Particularly, such a clock alone continuously generates highly-stable narrow-line laser radiation. Thus a local oscillator is not required to keep the optical phase during a dead time between interrogations as in passive clocks, but only to boost the active clock's low output power to practically usa…
▽ More
Active optical frequency standards provide interesting alternatives to their passive counterparts. Particularly, such a clock alone continuously generates highly-stable narrow-line laser radiation. Thus a local oscillator is not required to keep the optical phase during a dead time between interrogations as in passive clocks, but only to boost the active clock's low output power to practically usable levels with the current state of technology. Here we investigate the spectral properties and the stability of active clocks, including homogeneous and inhomogeneous broadening effects. We find that for short averaging times the stability is limited by photon shot noise from the limited emitted laser power and at long averaging times by phase diffusion of the laser output. Operational parameters for best long-term stability were identified. Using realistic numbers for an active clock with $^{87}$Sr we find that an optimized stability of $σ_y(τ) \approx 4\times10^{-18}/\sqrt{τ[\mathrm{s}]}$ is achievable.
△ Less
Submitted 26 October, 2022; v1 submitted 27 May, 2022;
originally announced May 2022.
-
Thermal noise and mechanical loss of SiO$_2$/Ta$_2$O$_5$ optical coatings at cryogenic temperatures
Authors:
John M Robinson,
Eric Oelker,
William R Milner,
Dhruv Kedar,
Wei Zhang,
Thomas Legero,
Dan G Matei,
Sebastian Hafner,
Fritz Riehle,
Uwe Sterr,
Jun Ye
Abstract:
Mechanical loss of dielectric mirror coatings sets fundamental limits for both gravitational wave detectors and cavity-stabilized optical local oscillators for atomic clocks. Two approaches are used to determine the mechanical loss: ringdown measurements of the coating quality factor and direct measurement of the coating thermal noise. Here we report a systematic study of the mirror thermal noise…
▽ More
Mechanical loss of dielectric mirror coatings sets fundamental limits for both gravitational wave detectors and cavity-stabilized optical local oscillators for atomic clocks. Two approaches are used to determine the mechanical loss: ringdown measurements of the coating quality factor and direct measurement of the coating thermal noise. Here we report a systematic study of the mirror thermal noise from room temperature to 4 K by operating reference cavities at these temperatures. The directly measured thermal noise is used to extract the corresponding mechanical loss for SiO$_2$/Ta$_2$O$_5$ coatings, which are compared with previously reported values.
△ Less
Submitted 10 November, 2020;
originally announced November 2020.
-
Simple and compact diode laser system stabilized to Doppler-broadened iodine-lines at 633 nm
Authors:
Florian Krause,
Erik Benkler,
Christian Nölleke,
Patrick Leisching,
Uwe Sterr
Abstract:
We present a compact iodine-stabilized laser system at 633 nm, based on a distributed-feedback laser diode. Within a footprint of $27\times 15$ cm$^2$ the system provides 5 mW of frequency stabilized light from a single-mode fiber. Its performance was evaluated in comparison to Cs clocks representing primary frequency standards, realizing the SI unit Hz via an optical frequency comb. With the best…
▽ More
We present a compact iodine-stabilized laser system at 633 nm, based on a distributed-feedback laser diode. Within a footprint of $27\times 15$ cm$^2$ the system provides 5 mW of frequency stabilized light from a single-mode fiber. Its performance was evaluated in comparison to Cs clocks representing primary frequency standards, realizing the SI unit Hz via an optical frequency comb. With the best suited absorption line the laser reaches a fractional frequency instability below $10^{-10}$ for averaging times above 10 s. The performance was investigated at several iodine lines and a model was developed to describe the observed stability on the different lines.
△ Less
Submitted 5 November, 2020;
originally announced November 2020.
-
Optical frequency ratio of a ${}^{171}\mathrm{Yb}^+$ single-ion clock and a ${}^{87}\mathrm{Sr}$ lattice clock
Authors:
Sören Dörscher,
Nils Huntemann,
Roman Schwarz,
Richard Lange,
Erik Benkler,
Burghard Lipphardt,
Uwe Sterr,
Ekkehard Peik,
Christian Lisdat
Abstract:
We report direct measurements of the frequency ratio of the 642 THz ${}^2S_{1/2} (F=0)$--${}^2F_{7/2} (F=3)$ electric octupole transition in ${}^{171}\mathrm{Yb}^+$ and the 429 THz ${}^1S_0$--${}^3P_0$ transition in ${}^{87}\mathrm{Sr}$. A series of 107 measurements has been performed at the Physikalisch-Technische Bundesanstalt between December 2012 and October 2019. Long-term variations of the r…
▽ More
We report direct measurements of the frequency ratio of the 642 THz ${}^2S_{1/2} (F=0)$--${}^2F_{7/2} (F=3)$ electric octupole transition in ${}^{171}\mathrm{Yb}^+$ and the 429 THz ${}^1S_0$--${}^3P_0$ transition in ${}^{87}\mathrm{Sr}$. A series of 107 measurements has been performed at the Physikalisch-Technische Bundesanstalt between December 2012 and October 2019. Long-term variations of the ratio are larger than expected from the individual measurement uncertainties of few $10^{-17}$. The cause of these variations remains unknown. Even taking these into account, we find a fractional uncertainty of the frequency ratio of $2.5 \times 10^{-17}$, which improves upon previous knowledge by one order of magnitude. The average frequency ratio is $ν_{\mathrm{Yb}^+} / ν_{\mathrm{Sr}} = 1.495\,991\,618\,544\,900\,537(38)$. This represents one of the most accurate measurements between two different atomic species to date.
△ Less
Submitted 11 September, 2020;
originally announced September 2020.
-
Long term measurement of the $^{87}$Sr clock frequency at the limit of primary Cs clocks
Authors:
R. Schwarz,
S. Dörscher,
A. Al-Masoudi,
E. Benkler,
T. Legero,
U. Sterr,
S. Weyers,
J. Rahm,
B. Lipphardt,
C. Lisdat
Abstract:
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement…
▽ More
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement run has been extended by use of a hydrogen maser as flywheel to improve the statistical uncertainty given by the Cs clocks. We determine an averaged transition frequency of $429\:228\:004\:229\:873.00(0.07)$~Hz with $1.5\times10^{-16}$ fractional uncertainty, at the limit of the current realization of the unit hertz. Analysis of the data provides an improved limit on the coupling of the gravitational potential of the Sun to the proton--electron mass ratio $μ$, and confirms the limits on its temporal drift.
△ Less
Submitted 15 May, 2020;
originally announced May 2020.
-
A transportable interrogation laser system with an instability of $\mathrm{mod}\,σ_{\rm y} = 3\times10^{-16}$
Authors:
Sebastian Häfner,
Sofia Herbers,
Stefan Vogt,
Christian Lisdat,
Uwe Sterr
Abstract:
We present an interrogation laser system for a transportable strontium lattice clock operating at 698 nm, which is based on an ultra-low-expansion glass reference cavity. Transportability is achieved by implementing a rigid, compact, and vibration insensitive mounting of the 12 cm-long reference cavity, sustaining shocks of up to 50 g. The cavity is mounted at optimized support points that indepen…
▽ More
We present an interrogation laser system for a transportable strontium lattice clock operating at 698 nm, which is based on an ultra-low-expansion glass reference cavity. Transportability is achieved by implementing a rigid, compact, and vibration insensitive mounting of the 12 cm-long reference cavity, sustaining shocks of up to 50 g. The cavity is mounted at optimized support points that independently constrain all degrees of freedom. This mounting concept is especially beneficial for cavities with a ratio of length $L$ over diameter $D$ $L/D>1$. Generally large $L$ helps to reduce thermal noise-induced laser frequency instability while small $D$ leads to small cavity volume. The frequency instability was evaluated, reaching its thermal noise floor of $\mathrm{mod}\,σ_{\rm y} \approx 3 \times 10^{-16}$ for averaging times between 0.5 s and 10 s. The laser system was successfully operated during several field studies.
△ Less
Submitted 19 May, 2020; v1 submitted 3 March, 2020;
originally announced March 2020.
-
Dynamic decoupling of laser phase noise in compound atomic clocks
Authors:
Sören Dörscher,
Ali Al-Masoudi,
Marcin Bober,
Roman Schwarz,
Richard Hobson,
Uwe Sterr,
Christian Lisdat
Abstract:
The frequency stability achieved by an optical atomic clock ultimately depends on the coherence of its local oscillator. Even the best ultrastable lasers only allow interrogation times of a few seconds, at present. Here we present a universal measurement protocol that overcomes this limitation. Engineered dynamic decoupling of laser phase noise allows any optical atomic clock with high signal-to-n…
▽ More
The frequency stability achieved by an optical atomic clock ultimately depends on the coherence of its local oscillator. Even the best ultrastable lasers only allow interrogation times of a few seconds, at present. Here we present a universal measurement protocol that overcomes this limitation. Engineered dynamic decoupling of laser phase noise allows any optical atomic clock with high signal-to-noise ratio in a single interrogation to reconstruct the laser's phase well beyond its coherence limit. A compound clock is then formed in combination with another optical clock of any type, allowing the latter to achieve significantly higher frequency stability than on its own. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment with a phase reconstruction fidelity of 99 %. The protocol enables minute-long interrogation for the best ultrastable laser systems. Likewise, it can improve clock performance where less stable local oscillators are used, such as in transortable systems.
△ Less
Submitted 29 November, 2019;
originally announced November 2019.
-
Prospects and challenges for squeezing-enhanced optical atomic clocks
Authors:
Marius Schulte,
Christian Lisdat,
Piet O. Schmidt,
Uwe Sterr,
Klemens Hammerer
Abstract:
We have investigated the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we can give quantitative predictions on the optimal clock stability for a given dead time and laser noise. Our analytic predictions are in very good agreement with numerical simulat…
▽ More
We have investigated the benefits of spin squeezed states for clocks operated with typical Brownian frequency noise-limited laser sources. Based on an analytic model of the closed servo-loop of an optical atomic clock, we can give quantitative predictions on the optimal clock stability for a given dead time and laser noise. Our analytic predictions are in very good agreement with numerical simulations of the closed servo-loop. We find that for usual cyclic Ramsey interrogation of single atomic ensembles with dead time, even with the current most stable lasers spin squeezing can only improve the clock stability for ensembles below a critical atom number of about one thousand in an optical Sr lattice clock. Even with a future improvement of the laser performance by one order of magnitude the critical atom number still remains below 100,000. In contrast, clocks based on smaller, non-scalable ensembles, such as ion clocks, can already benefit from squeezed states with current clock lasers.
△ Less
Submitted 9 September, 2020; v1 submitted 3 November, 2019;
originally announced November 2019.
-
End-to-end topology for fiber comb based optical frequency transfer at the $10^{-21}$ level
Authors:
Erik Benkler,
Burghard Lipphardt,
Thomas Puppe,
Rafał Wilk,
Felix Rohde,
Uwe Sterr
Abstract:
We introduce a simple and robust scheme for optical frequency transfer of an ultra-stable source light field via an optical frequency comb to a field at a target optical frequency, where highest stability is required, e.g. for the interrogation of an optical clock. The scheme relies on a topology for end-to-end suppression of the influence of optical path-length fluctuations, which is attained by…
▽ More
We introduce a simple and robust scheme for optical frequency transfer of an ultra-stable source light field via an optical frequency comb to a field at a target optical frequency, where highest stability is required, e.g. for the interrogation of an optical clock. The scheme relies on a topology for end-to-end suppression of the influence of optical path-length fluctuations, which is attained by actively phase-stabilized delivery, combined with common-path propagation. This approach provides a robust stability improvement without the need for additional isolation against environmental disturbances such as temperature, pressure or humidity changes. We measure residual frequency transfer instabilities by comparing the frequency transfers carried out with two independent combs simultaneously. Residual fractional frequency instabilities between two systems of $8\times10^{-18}$ at 1 s and $3\times10^{-21}$ at $10^5$ s averaging time are observed. We discuss the individual noise contributions to the residual instability. The presented scheme is technically simple, robust against environmental parameter fluctuations, and enables an ultra-stable frequency transfer, e.g. to optical clock lasers or to lasers in gravitational wave detectors.
△ Less
Submitted 1 April, 2020; v1 submitted 9 October, 2019;
originally announced October 2019.
-
SAGE: A Proposal for a Space Atomic Gravity Explorer
Authors:
G. M. Tino,
A. Bassi,
G. Bianco,
K. Bongs,
P. Bouyer,
L. Cacciapuoti,
S. Capozziello,
X. Chen,
M. L. Chiofalo,
A. Derevianko,
W. Ertmer,
N. Gaaloul,
P. Gill,
P. W. Graham,
J. M. Hogan,
L. Iess,
M. A. Kasevich,
H. Katori,
C. Klempt,
X. Lu,
L. -S. Ma,
H. Müller,
N. R. Newbury,
C. Oates,
A. Peters
, et al. (22 additional authors not shown)
Abstract:
The proposed mission "Space Atomic Gravity Explorer" (SAGE) has the scientific objective to investigate gravitational waves, dark matter, and other fundamental aspects of gravity as well as the connection between gravitational physics and quantum physics using new quantum sensors, namely, optical atomic clocks and atom interferometers based on ultracold strontium atoms.
The proposed mission "Space Atomic Gravity Explorer" (SAGE) has the scientific objective to investigate gravitational waves, dark matter, and other fundamental aspects of gravity as well as the connection between gravitational physics and quantum physics using new quantum sensors, namely, optical atomic clocks and atom interferometers based on ultracold strontium atoms.
△ Less
Submitted 18 November, 2019; v1 submitted 8 July, 2019;
originally announced July 2019.
-
Demonstration of a time scale based on a stable optical carrier
Authors:
William R. Milner,
John M. Robinson,
Colin J. Kennedy,
Tobias Bothwell,
Dhruv Kedar,
Dan G. Matei,
Thomas Legero,
Uwe Sterr,
Fritz Riehle,
Holly Leopardi,
Tara M. Fortier,
Jeffrey A. Sherman,
Judah Levine,
Jian Yao,
Jun Ye,
Eric Oelker
Abstract:
We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even wh…
▽ More
We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even when they are steered to optical frequency standards. Our analysis indicates that this time scale is capable of reaching a stability below $1\times10^{-17}$ after a few months of averaging, making timekeeping at the $10^{-18}$ level a realistic prospect.
△ Less
Submitted 6 July, 2019;
originally announced July 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty
Authors:
Moustafa Abdel-Hafiz,
Piotr Ablewski,
Ali Al-Masoudi,
Héctor Álvarez Martínez,
Petr Balling,
Geoffrey Barwood,
Erik Benkler,
Marcin Bober,
Mateusz Borkowski,
William Bowden,
Roman Ciuryło,
Hubert Cybulski,
Alexandre Didier,
Miroslav Doležal,
Sören Dörscher,
Stephan Falke,
Rachel M. Godun,
Ramiz Hamid,
Ian R. Hill,
Richard Hobson,
Nils Huntemann,
Yann Le Coq,
Rodolphe Le Targat,
Thomas Legero,
Thomas Lindvall
, et al. (20 additional authors not shown)
Abstract:
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency…
▽ More
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
△ Less
Submitted 13 August, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
Optical clock intercomparison with $6\times 10^{-19}$ precision in one hour
Authors:
E. Oelker,
R. B. Hutson,
C. J. Kennedy,
L. Sonderhouse,
T. Bothwell,
A. Goban,
D. Kedar,
C. Sanner,
J. M. Robinson,
G. E. Marti,
D. G. Matei,
T. Legero,
M. Giunta,
R. Holzwarth,
F. Riehle,
U. Sterr,
J. Ye
Abstract:
Improvements in atom-light coherence are foundational to progress in quantum information science, quantum optics, and precision metrology. Optical atomic clocks require local oscillators with exceptional optical coherence due to the challenge of performing spectroscopy on their ultra-narrow linewidth clock transitions. Advances in laser stabilization have thus enabled rapid progress in clock preci…
▽ More
Improvements in atom-light coherence are foundational to progress in quantum information science, quantum optics, and precision metrology. Optical atomic clocks require local oscillators with exceptional optical coherence due to the challenge of performing spectroscopy on their ultra-narrow linewidth clock transitions. Advances in laser stabilization have thus enabled rapid progress in clock precision. A new class of ultrastable lasers based on cryogenic silicon reference cavities has recently demonstrated the longest optical coherence times to date. In this work we utilize such a local oscillator, along with a state-of-the-art frequency comb for coherence transfer, with two Sr optical lattice clocks to achieve an unprecedented level of clock stability. Through an anti-synchronous comparison, the fractional instability of both clocks is assessed to be $4.8\times 10^{-17}/\sqrtτ$ for an averaging time $τ$ in seconds. Synchronous interrogation reveals a quantum projection noise dominated instability of $3.5(2)\times10^{-17}/\sqrtτ$, resulting in a precision of $5.8(3)\times 10^{-19}$ after a single hour of averaging. The ability to measure sub-$10^{-18}$ level frequency shifts in such short timescales will impact a wide range of applications for clocks in quantum sensing and fundamental physics. For example, this precision allows one to resolve the gravitational red shift from a 1 cm elevation change in only 20 minutes.
△ Less
Submitted 7 February, 2019;
originally announced February 2019.
-
Crystalline optical cavity at 4 K with thermal noise limited instability and ultralow drift
Authors:
John M. Robinson,
Eric Oelker,
William R. Milner,
Wei Zhang,
Thomas Legero,
Dan G. Matei,
Fritz Riehle,
Uwe Sterr,
Jun Ye
Abstract:
Crystalline optical cavities are the foundation of today's state-of-the-art ultrastable lasers. Building on our previous silicon cavity effort, we now achieve the fundamental thermal noise-limited stability for a 6 cm long silicon cavity cooled to 4 Kelvin, reaching $6.5\times10^{-17}$ from 0.8 to 80 seconds. We also report for the first time a clear linear dependence of the cavity frequency drift…
▽ More
Crystalline optical cavities are the foundation of today's state-of-the-art ultrastable lasers. Building on our previous silicon cavity effort, we now achieve the fundamental thermal noise-limited stability for a 6 cm long silicon cavity cooled to 4 Kelvin, reaching $6.5\times10^{-17}$ from 0.8 to 80 seconds. We also report for the first time a clear linear dependence of the cavity frequency drift on the incident optical power. The lowest fractional frequency drift of $-3\times10^{-19}$/s is attained at a transmitted power of 40 nW, with an extrapolated drift approaching zero in the absence of optical power. These demonstrations provide a promising direction to reach a new performance domain for stable lasers, with stability better than $1\times10^{-17}$ and fractional linear drift below $1\times10^{-19}$/s.
△ Less
Submitted 6 December, 2018;
originally announced December 2018.
-
A high-performance optical lattice clock based on bosonic atoms
Authors:
Stefano Origlia,
Mysore Srinivas Pramod,
Stephan Schiller,
Yeshpal Singh,
Kai Bongs,
Roman Schwarz,
Ali Al-Masoudi,
Sören Dörscher,
Sofia Herbers,
Sebastian Häfner,
Uwe Sterr,
Christian Lisdat
Abstract:
Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and $2.0\times 10^{-17}$ accuracy, both values improving on previous work by a factor 30. This was enabled by probing the clock transition with an ultra-long inter…
▽ More
Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and $2.0\times 10^{-17}$ accuracy, both values improving on previous work by a factor 30. This was enabled by probing the clock transition with an ultra-long interrogation time of 4 s, using the long coherence time provided by a cryogenic silicon resonator, by careful stabilization of relevant operating parameters, and by operating at low atom density. This work demonstrates that bosonic clocks, in combination with highly coherent interrogation lasers, are suitable for high-accuracy applications with particular requirements, such as high reliability, transportability, operation in space, or suitability for particular fundamental physics topics. As an example, we determine the $^{88}\textrm{Sr} - ^{87}$Sr isotope shift with 12 mHz uncertainty.
△ Less
Submitted 8 March, 2018;
originally announced March 2018.
-
Lattice-induced photon scattering in an optical lattice clock
Authors:
Sören Dörscher,
Roman Schwarz,
Ali Al-Masoudi,
Stephan Falke,
Uwe Sterr,
Christian Lisdat
Abstract:
We investigate scattering of lattice laser radiation in a strontium optical lattice clock and its implications for operating clocks at interrogation times up to several tens of seconds. Rayleigh scattering does not cause significant decoherence of the atomic superposition state near a magic wavelength. Among the Raman scattering processes, lattice-induced decay of the excited state…
▽ More
We investigate scattering of lattice laser radiation in a strontium optical lattice clock and its implications for operating clocks at interrogation times up to several tens of seconds. Rayleigh scattering does not cause significant decoherence of the atomic superposition state near a magic wavelength. Among the Raman scattering processes, lattice-induced decay of the excited state $(5s5p)\,{}^{3}\mathrm{P}_{0}$ to the ground state $(5s^2)\,{}^{1}\mathrm{S}_{0}$ via the state $(5s5p)\,{}^{3}\mathrm{P}_{1}$ is particularly relevant, as it reduces the effective lifetime of the excited state and gives rise to quantum projection noise in spectroscopy. We observe this process in our experiment and find a decay rate of $556(15)\times 10^{-6}\,\mathrm{s}^{-1}$ per photon recoil energy $E_\mathrm{r}$ of effective lattice depth, which agrees well with the rate we predict from atomic data. We also derive a natural lifetime $τ= 330(140)\,\mathrm{s}$ of the excited state ${}^{3}\mathrm{P}_{0}$ from our observations. Lattice-induced decay thus exceeds spontaneous decay at typical lattice depths used by present clocks. It eventually limits interrogation times in clocks restricted to high-intensity lattices, but can be largely avoided, e.g., by operating them with shallow lattice potentials.
△ Less
Submitted 19 July, 2018; v1 submitted 8 February, 2018;
originally announced February 2018.
-
An ultrastable silicon cavity in a continuously operating closed-cycle cryostat at 4 K
Authors:
W. Zhang,
J. M. Robinson,
L. Sonderhouse,
E. Oelker,
C. Benko,
J. L. Hall,
T. Legero,
D. G. Matei,
F. Riehle,
U. Sterr,
J. Ye
Abstract:
We report on a laser locked to a silicon cavity operating continuously at 4 K with $1 \times 10^{-16}$ instability and a median linewidth of 17 mHz at 1542 nm. This is a ten-fold improvement in short-term instability, and a $10^4$ improvement in linewidth, over previous sub-10 K systems. Operating at low temperatures reduces the thermal noise floor, and thus is advantageous toward reaching an inst…
▽ More
We report on a laser locked to a silicon cavity operating continuously at 4 K with $1 \times 10^{-16}$ instability and a median linewidth of 17 mHz at 1542 nm. This is a ten-fold improvement in short-term instability, and a $10^4$ improvement in linewidth, over previous sub-10 K systems. Operating at low temperatures reduces the thermal noise floor, and thus is advantageous toward reaching an instability of $10^{-18}$, a long-sought goal of the optical clock community. The performance of this system demonstrates the technical readiness for the development of the next generation of ultrastable lasers that operate with ultranarrow linewidth and long-term stability without user intervention.
△ Less
Submitted 5 November, 2017; v1 submitted 17 August, 2017;
originally announced August 2017.
-
Geodesy and metrology with a transportable optical clock
Authors:
Jacopo Grotti,
Silvio Koller,
Stefan Vogt,
Sebastian Häfner,
Uwe Sterr,
Christian Lisdat,
Heiner Denker,
Christian Voigt,
Ludger Timmen,
Antoine Rolland,
Fred N. Baynes,
Helen S. Margolis,
Michel Zampaolo,
Pierre Thoumany,
Marco Pizzocaro,
Benjamin Rauf,
Filippo Bregolin,
Anna Tampellini,
Piero Barbieri,
Massimo Zucco,
Giovanni A. Costanzo,
Cecilia Clivati,
Filippo Levi,
Davide Calonico
Abstract:
The advent of novel measurement instrumentation can lead to paradigm shifts in scientific research. Optical atomic clocks, due to their unprecedented stability and uncertainty, are already being used to test physical theories and herald a revision of the International System of units (SI). However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy, a major…
▽ More
The advent of novel measurement instrumentation can lead to paradigm shifts in scientific research. Optical atomic clocks, due to their unprecedented stability and uncertainty, are already being used to test physical theories and herald a revision of the International System of units (SI). However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy, a major challenge remains. This is their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations. Here we report the first field measurement campaign performed with a ubiquitously applicable $^{87}$Sr optical lattice clock. We use it to determine the gravity potential difference between the middle of a mountain and a location 90 km apart, exploiting both local and remote clock comparisons to eliminate potential clock errors. A local comparison with a $^{171}$Yb lattice clock also serves as an important check on the international consistency of independently developed optical clocks. This campaign demonstrates the exciting prospects for transportable optical clocks.
△ Less
Submitted 11 May, 2017;
originally announced May 2017.
-
Test of special relativity using a fiber network of optical clocks
Authors:
P. Delva,
J. Lodewyck,
S. Bilicki,
E. Bookjans,
G. Vallet,
R. Le Targat,
P. -E. Pottie,
C. Guerlin,
F. Meynadier,
C. Le Poncin-Lafitte,
O. Lopez,
A. Amy-Klein,
W. -K. Lee,
N. Quintin,
C. Lisdat,
A. Al-Masoudi,
S. Dörscher,
C. Grebing,
G. Grosche,
A. Kuhl,
S. Raupach,
U. Sterr,
I. R. Hill,
R. Hobson,
W. Bowden
, et al. (6 additional authors not shown)
Abstract:
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted…
▽ More
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson--Mansouri--Sexl parameter $|α|\lesssim 1.1 \times10^{-8}$ quantifying a violation of time dilation, thus improving by a factor of around two the best known constraint obtained with Ives--Stilwell type experiments, and by two orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this paper will improve by orders of magnitude in the near future.
△ Less
Submitted 12 June, 2017; v1 submitted 13 March, 2017;
originally announced March 2017.
-
1.5 $μ$m lasers with sub 10 mHz linewidth
Authors:
D. G. Matei,
T. Legero,
S. Häfner,
C. Grebing,
R. Weyrich,
W. Zhang,
L. Sonderhouse,
J. M. Robinson,
J. Ye,
F. Riehle,
U. Sterr
Abstract:
We report on two ultrastable lasers each stabilized to independent silicon Fabry-Pérot cavities operated at 124 K. The fractional frequency instability of each laser is completely determined by the fundamental thermal Brownian noise of the mirror coatings with a flicker noise floor of $4 \times 10^{-17}$ for integration times between 0.8 s and a few tens of seconds. We rigorously treat the notorio…
▽ More
We report on two ultrastable lasers each stabilized to independent silicon Fabry-Pérot cavities operated at 124 K. The fractional frequency instability of each laser is completely determined by the fundamental thermal Brownian noise of the mirror coatings with a flicker noise floor of $4 \times 10^{-17}$ for integration times between 0.8 s and a few tens of seconds. We rigorously treat the notorious divergencies encountered with the associated flicker frequency noise and derive methods to relate this noise to observable and practically relevant linewidths and coherence times. The individual laser linewidth obtained from the phase noise spectrum or the direct beat note between the two lasers can be as small as 5 mHz at 194 THz. From the measured phase evolution between the two laser fields we derive usable phase coherence times for different applications of 11 s and 60 s.
△ Less
Submitted 9 June, 2017; v1 submitted 15 February, 2017;
originally announced February 2017.
-
Ground-state properties of Ca$_2$ from narrow line two-color photoassociation
Authors:
Evgenij Pachomow,
Veit Peter Dahlke,
Eberhard Tiemann,
Fritz Riehle,
Uwe Sterr
Abstract:
By two-color photoassociation of $^{40}$Ca four weakly bound vibrational levels in the Ca$_2$ \Xpot ground state potential were measured, using highly spin-forbidden transitions to intermediate states of the coupled system $^3Π_{u}$ and $^3Σ^+ _{u}$ near the ${^3P_1}$+${^1S_0}$ asymptote. From the observed binding energies, including the least bound state, the long range dispersion coefficients…
▽ More
By two-color photoassociation of $^{40}$Ca four weakly bound vibrational levels in the Ca$_2$ \Xpot ground state potential were measured, using highly spin-forbidden transitions to intermediate states of the coupled system $^3Π_{u}$ and $^3Σ^+ _{u}$ near the ${^3P_1}$+${^1S_0}$ asymptote. From the observed binding energies, including the least bound state, the long range dispersion coefficients $\mathrm{C}_6, \mathrm{C}_8,\mathrm{C}_{10}$ and a precise value for the s-wave scattering length of 308.5(50)~$a_0$ were derived. From mass scaling we also calculated the corresponding scattering length for other natural isotopes. From the Autler-Townes splitting of the spectra, the molecular Rabi frequency has been determined as function of the laser intensity for one bound-bound transition. The observed value for the Rabi-frequency is in good agreement with calculated transition moments based on the derived potentials, assuming a dipole moment being independent of internuclear separation for the atomic pair model.
△ Less
Submitted 23 May, 2017; v1 submitted 2 February, 2017;
originally announced February 2017.
-
A transportable optical lattice clock with $7\times10^{-17}$ uncertainty
Authors:
S. B. Koller,
J. Grotti,
St. Vogt,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
U. Sterr,
Ch. Lisdat
Abstract:
We present a transportable optical clock (TOC) with $^{87}$Sr. Its complete characterization against a stationary lattice clock resulted in a systematic uncertainty of ${7.4 \times 10^{-17}}$ which is currently limited by the statistics of the determination of the residual lattice light shift. The measurements confirm that the systematic uncertainty is reduceable to below the design goal of…
▽ More
We present a transportable optical clock (TOC) with $^{87}$Sr. Its complete characterization against a stationary lattice clock resulted in a systematic uncertainty of ${7.4 \times 10^{-17}}$ which is currently limited by the statistics of the determination of the residual lattice light shift. The measurements confirm that the systematic uncertainty is reduceable to below the design goal of $1 \times 10^{-17}$. The instability of our TOC is $1.3 \times 10^{-15}/\sqrt{(τ/s)}$. Both, the systematic uncertainty and the instability are to our best knowledge currently the best achieved with any type of transportable clock. For autonomous operation the TOC is installed in an air-conditioned car-trailer. It is suitable for chronometric leveling with sub-meter resolution as well as intercontinental cross-linking of optical clocks, which is essential for a redefiniton of the SI second. In addition, the TOC will be used for high precision experiments for fundamental science that are commonly tied to precise frequency measurements and it is a first step to space borne optical clocks
△ Less
Submitted 20 September, 2016;
originally announced September 2016.
-
Development of a strontium optical lattice clock for the SOC mission on the ISS
Authors:
S. Origlia,
S. Schiller,
M. S. Pramod,
L. Smith,
Y. Singh,
W. He,
S. Viswam,
D. Świerad,
J. Hughes,
K. Bongs,
U. Sterr,
Ch. Lisdat,
S. Vogt,
S. Bize,
J. Lodewyck,
R. Le Targat,
D. Holleville,
B. Venon,
P. Gill,
G. Barwood,
I. R. Hill,
Y. Ovchinnikov,
A. Kulosa,
W. Ertmer,
E. -M. Rasel
, et al. (3 additional authors not shown)
Abstract:
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than…
▽ More
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than $1 \times 10^{-17}$ uncertainty and $1 \times 10^{-15} τ^{-1/2}$ instability. Within an EU-FP7-funded project, a strontium optical lattice clock demonstrator has been developed. Goal performances are instability below $1 \times 10^{-15} τ^{-1/2}$ and fractional inaccuracy $5 \times 10^{-17}$. For the design of the clock, techniques and approaches suitable for later space application are used, such as modular design, diode lasers, low power consumption subunits, and compact dimensions. The Sr clock apparatus is fully operational, and the clock transition in $^{88}$Sr was observed with linewidth as small as 9 Hz.
△ Less
Submitted 19 March, 2016;
originally announced March 2016.
-
A clock network for geodesy and fundamental science
Authors:
C. Lisdat,
G. Grosche,
N. Quintin,
C. Shi,
S. M. F. Raupach,
C. Grebing,
D. Nicolodi,
F. Stefani,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
J. -L. Robyr,
N. Chiodo,
S. Bilicki,
E. Bookjans,
A. Koczwara,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
M. Abgrall,
M. Lours,
T. Legero,
H. Schnatz
, et al. (10 additional authors not shown)
Abstract:
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of t…
▽ More
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of the clocks themselves. This is achieved by a phase-coherent optical frequency transfer via a 1415 km long telecom fiber link that enables substantially better precision than classical means of frequency transfer. The fractional precision in comparing the optical clocks of three parts in $10^{17}$ was reached after only 1000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than with any other existing frequency transfer method. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Realization of a time-scale with an accurate optical lattice clock
Authors:
C. Grebing,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
V. Gerginov,
S. Weyers,
B. Lipphardt,
F. Riehle,
U. Sterr,
C. Lisdat
Abstract:
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a cont…
▽ More
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a continuous realization of a timescale impractical. In this paper, we demonstrate how this situation can be resolved and that a timescale based on an optical clock can be established that is superior to one based on even the best caesium fountain clocks. The paper also gives further proof of the international consistency of strontium lattice clocks on the $10^{-16}$ accuracy level, which is another prerequisite for a change in the definition of the second.
△ Less
Submitted 22 February, 2016; v1 submitted 12 November, 2015;
originally announced November 2015.
-
Noise and instability of an optical lattice clock
Authors:
Ali Al-Masoudi,
Sören Dörscher,
Sebastian Häfner,
Uwe Sterr,
Christian Lisdat
Abstract:
We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise--limited detection is possible if more than 130~atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-$10^{-16}$ fractional frequency instability allows…
▽ More
We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise--limited detection is possible if more than 130~atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-$10^{-16}$ fractional frequency instability allows to infer the clock stability for different modes of operation. Excellent agreement with experimental observations for the instability of the difference between two interleaved stabilizations is found. We infer a clock instability of $1.6 \times 10^{-16}/\sqrt{τ/ \mathrm{s}}$ as a function of averaging time $τ$ for normal clock operation.
△ Less
Submitted 3 November, 2015; v1 submitted 17 July, 2015;
originally announced July 2015.
-
Nonlinear Zeeman effect in photoassociation spectra of $^{40}$Ca near the $^3$P$_1$+$^1$S$_0$ asymptote
Authors:
Eberhard Tiemann,
Max Kahmann,
Evgenij Pachomow,
Fritz Riehle,
Uwe Sterr
Abstract:
We present calculations of the Zeeman effect of narrow photoassociation lines of $^{40}$Ca near the $^3$P$_1$ + $^1$S$_0$ asymptote. Using a coupled-channel model we find a nonlinear Zeeman effect that even at low fields of a few mT amounts to several kHz. With this model we analyze previous measurements and give corrected long range dispersion coefficients of the $^3Π_{u}$ and $^3Σ^+ _{u}$ states…
▽ More
We present calculations of the Zeeman effect of narrow photoassociation lines of $^{40}$Ca near the $^3$P$_1$ + $^1$S$_0$ asymptote. Using a coupled-channel model we find a nonlinear Zeeman effect that even at low fields of a few mT amounts to several kHz. With this model we analyze previous measurements and give corrected long range dispersion coefficients of the $^3Π_{u}$ and $^3Σ^+ _{u}$ states.
△ Less
Submitted 12 June, 2015;
originally announced June 2015.
-
On the relation between uncertainties of weighted frequency averages and the various types of Allan deviations
Authors:
Erik Benkler,
Christian Lisdat,
Uwe Sterr
Abstract:
The power spectral density in Fourier frequency domain, and the different variants of the Allan deviation (ADEV) in dependence on the averaging time are well established tools to analyse the fluctuation properties and frequency instability of an oscillatory signal. It is often supposed that the statistical uncertainty of a measured average frequency is given by the ADEV at a well considered averag…
▽ More
The power spectral density in Fourier frequency domain, and the different variants of the Allan deviation (ADEV) in dependence on the averaging time are well established tools to analyse the fluctuation properties and frequency instability of an oscillatory signal. It is often supposed that the statistical uncertainty of a measured average frequency is given by the ADEV at a well considered averaging time. However, this approach requires further mathematical justification and refinement, which has already been done regarding the original ADEV for certain noise types. Here we provide the necessary background to use the modified Allan deviation (modADEV) and other two-sample deviations to determine the uncertainty of weighted frequency averages. The type of two-sample deviation used to determine the uncertainty depends on the method used for determination of the average. We find that the modADEV, which is connected with $Λ$-weighted averaging, and the two sample deviation associated to a linear phase regression weighting (parADEV) are in particular advantageous for measurements, in which white phase noise is dominating. Furthermore, we derive a procedure how to minimize the uncertainty of a measurement for a typical combination of white phase and frequency noise by adaptive averaging of the data set with different weighting functions. Finally, some aspects of the theoretical considerations for real-world frequency measurement equipment are discussed.
△ Less
Submitted 27 April, 2015; v1 submitted 2 April, 2015;
originally announced April 2015.
-
Development of a strontium optical lattice clock for the SOC mission on the ISS
Authors:
K. Bongs,
Y. Singh,
L. Smith,
W. He,
O. Kock,
D. Swierad,
J. Hughes,
S. Schiller,
S. Alighanbari,
S. Origlia,
S. Vogt,
U. Sterr,
Ch. Lisdat,
R. Le Targat,
J. Lodewyck,
D. Holleville,
B. Venon,
S. Bize,
G. P. Barwood,
P. Gill,
I. R. Hill,
Y. B. Ovchinnikov,
N. Poli,
G. M. Tino,
J. Stuhler
, et al. (2 additional authors not shown)
Abstract:
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at l…
▽ More
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project no. 263500, during the years 2011-2015 a compact, modular and robust strontium lattice optical clock demonstrator has been developed. Goal performance is a fractional frequency instability below 1x10^{-15}, tau^{-1/2} and a fractional inaccuracy below 5x10^{-17}. Here we describe the current status of the apparatus' development, including the laser subsystems. Robust preparation of cold {88}^Sr atoms in a second stage magneto-optical trap (MOT) is achieved.
△ Less
Submitted 29 March, 2015;
originally announced March 2015.
-
8E-17 fractional laser frequency instability with a long room-temperature cavity
Authors:
Sebastian Häfner,
Stephan Falke,
Christian Grebing,
Stefan Vogt,
Thomas Legero,
Mikko Merimaa,
Christian Lisdat,
Uwe Sterr
Abstract:
We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to acceleration of below $Δν/ ν$ < 2E-10 /g in all directions. Furthermore, fiber noise cancellations from a common reference point near the laser diode to the cavity m…
▽ More
We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to acceleration of below $Δν/ ν$ < 2E-10 /g in all directions. Furthermore, fiber noise cancellations from a common reference point near the laser diode to the cavity mirror and to additional user points (Sr clock and frequency comb) are implemented. Through comparison to other cavity-stabilized lasers and to a strontium lattice clock an instability of below 1E-16 at averaging times from 1 s to 1000 s is revealed.
△ Less
Submitted 31 March, 2015; v1 submitted 9 February, 2015;
originally announced February 2015.
-
A compact, robust, and transportable ultra-stable laser with a fractional frequency instability of $1\times10^{-15}$
Authors:
Qun-Feng Chen,
Alexander Nevsky,
Marco Cardace,
Stephan Schiller,
Thomas Legero,
Sebastian Häfner,
Andre Uhde,
Uwe Sterr
Abstract:
We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of $1\times10^{-15}$ at integration times between 1 to 10 s. The system was conceived as a prototype of a subsystem of a microwave-optical local oscillator to be used on the satellite mission STE-QUEST (Space-Time Explorer and QUantum Equivalence Principle Space Test, http://sci.es…
▽ More
We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of $1\times10^{-15}$ at integration times between 1 to 10 s. The system was conceived as a prototype of a subsystem of a microwave-optical local oscillator to be used on the satellite mission STE-QUEST (Space-Time Explorer and QUantum Equivalence Principle Space Test, http://sci.esa.int/ste-quest/). It was therefore designed to be compact, to sustain accelerations occurring during rocket launch, to exhibit low vibration sensitivity, and to reach a low frequency instability. Overall dimensions of the optical system are $40\textrm{ cm}\times20\textrm{ cm}\times30\textrm{ cm}$. The acceleration sensitivities of the optical frequency in the three directions were measured to be $1.7\times10^{-11}/g$, $8.0\times10^{-11}/g$, and $3.9\times10^{-10}/g$, and the absolute frequency instability was determined via a three-cornered hat measurement. The design is also appropriate and useful for terrestrial applications.
△ Less
Submitted 20 October, 2014;
originally announced October 2014.
-
A transportable strontium optical lattice clock
Authors:
N. Poli,
M. Schioppo,
S. Vogt,
St. Falke,
U. Sterr,
Ch. Lisdat,
G. M. Tino
Abstract:
We report on a transportable optical clock, based on laser-cooled strontium atoms trapped in an optical lattice. The experimental apparatus is composed of a compact source of ultra-cold strontium atoms including a compact cooling laser set-up and a transportable ultra-stable laser for interrogating the optical clock transition. The whole setup (excluding electronics) fits within a volume of less t…
▽ More
We report on a transportable optical clock, based on laser-cooled strontium atoms trapped in an optical lattice. The experimental apparatus is composed of a compact source of ultra-cold strontium atoms including a compact cooling laser set-up and a transportable ultra-stable laser for interrogating the optical clock transition. The whole setup (excluding electronics) fits within a volume of less than 2 m$^3$. The high degree of operation reliability of both systems allowed the spectroscopy of the clock transition to be performed with 10 Hz resolution. We estimate an uncertainty of the clock of $7\times10^{-15}$.
△ Less
Submitted 17 September, 2014; v1 submitted 16 September, 2014;
originally announced September 2014.
-
Ultra-stable laser with average fractional frequency drift rate below $5\times10^{-19}/\mathrm{s}$
Authors:
Christian Hagemann,
Christian Grebing,
Christian Lisdat,
Stephan Falke,
Thomas Legero,
Uwe Sterr,
Fritz Riehle,
Michael J. Martin,
Jun Ye
Abstract:
Cryogenic single-crystal optical cavities have the potential to provide highest dimensional stability. We have investigated the long-term performance of an ultra-stable laser system which is stabilized to a single-crystal silicon cavity operated at 124 K. Utilizing a frequency comb, the laser is compared to a hydrogen maser that is referenced to a primary caesium fountain standard and to the…
▽ More
Cryogenic single-crystal optical cavities have the potential to provide highest dimensional stability. We have investigated the long-term performance of an ultra-stable laser system which is stabilized to a single-crystal silicon cavity operated at 124 K. Utilizing a frequency comb, the laser is compared to a hydrogen maser that is referenced to a primary caesium fountain standard and to the $^{87}\mathrm{Sr}$ optical lattice clock at PTB. With fractional frequency instabilities of $σ_y(τ)\leq2\times10^{-16}$ for averaging times of $τ=60\mathrm{~s}$ to $1000\mathrm{~s}$ and $σ_y(1 \mathrm{d})\leq 2\times10^{-15}$ the stability of this laser, without any aid from an atomic reference, surpasses the best microwave standards for short averaging times and is competitive with the best hydrogen masers for longer times of one day. The comparison of modeled thermal response of the cavity with measured data indicates a fractional frequency drift below $5\times 10^{-19}/\mathrm{s}$, which we do not expect to be a fundamental limit.
△ Less
Submitted 7 May, 2014;
originally announced May 2014.
-
A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency
Authors:
Stephan Falke,
Nathan Lemke,
Christian Grebing,
Burghard Lipphardt,
Stefan Weyers,
Vladislav Gerginov,
Nils Huntemann,
Christian Hagemann,
Ali Al-Masoudi,
Sebastian Häfner,
Stefan Vogt,
Uwe Sterr,
Christian Lisdat
Abstract:
We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent ag…
▽ More
We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.
△ Less
Submitted 15 August, 2014; v1 submitted 12 December, 2013;
originally announced December 2013.
-
High accuracy photoassociation of $^{40}$Ca near the ${^3P_1}+{^1S_0}$ asymptote and its Zeeman effect
Authors:
Max Kahmann,
Eberhard Tiemann,
Oliver Appel,
Uwe Sterr,
Fritz Riehle
Abstract:
We report on the first measurement of narrow photoassociation lines of $^{40}$Ca near the ${^3P_1}+{^1S_0}$ asymptote related to the molecular states $^3Π_u$ and $^3Σ^+_u$. The highly accurate binding energies and Zeeman splittings are well described by a coupled channel theoretical model, confirming theoretical predictions of long-range coefficients. Our analysis shows that only the inclusion of…
▽ More
We report on the first measurement of narrow photoassociation lines of $^{40}$Ca near the ${^3P_1}+{^1S_0}$ asymptote related to the molecular states $^3Π_u$ and $^3Σ^+_u$. The highly accurate binding energies and Zeeman splittings are well described by a coupled channel theoretical model, confirming theoretical predictions of long-range coefficients. Our analysis shows that only the inclusion of both energies and Zeeman splittings provides an accurate description of the long-range interaction potentials.
△ Less
Submitted 27 June, 2013;
originally announced June 2013.
-
Reducing the effect of thermal noise in optical cavities
Authors:
Sana Amairi,
Thomas Legero,
Thomas Kessler,
Uwe Sterr,
Jannes B. Wübbena,
Olaf Mandel,
Piet O. Schmidt
Abstract:
Thermal noise in optical cavities imposes a severe limitation in the stability of the most advanced frequency standards at a level of a few 10^(-16) (s/t)^(1/2) for long averaging times t. In this paper we describe two schemes for reducing the effect of thermal noise in a reference cavity. In the first approach, we investigate the potential and limitations of operating the cavity close to instabil…
▽ More
Thermal noise in optical cavities imposes a severe limitation in the stability of the most advanced frequency standards at a level of a few 10^(-16) (s/t)^(1/2) for long averaging times t. In this paper we describe two schemes for reducing the effect of thermal noise in a reference cavity. In the first approach, we investigate the potential and limitations of operating the cavity close to instability, where the beam diameter on the mirrors becomes large. Our analysis shows that even a 10 cm short cavity can achieve a thermal noise limited fractional frequency instability in the low 10^(-16) regime. In the second approach, we increase the length of the optical cavity. We show that a 39.5 cm long cavity has the potential for a fractional frequency instability even below 10^(-16), while it seems feasible to achieve a reduced sensitivity of <10^(-10)/g for vibration-induced fractional length changes in all three directions.
△ Less
Submitted 17 December, 2013; v1 submitted 14 December, 2012;
originally announced December 2012.
-
A compact and efficient strontium oven for laser-cooling experiments
Authors:
Marco Schioppo,
Nicola Poli,
Marco Prevedelli,
Stephan Falke,
Christian Lisdat,
Uwe Sterr,
Guglielmo Maria Tino
Abstract:
Here we describe a compact and efficient strontium oven well suited for laser-cooling experiments. Novel design solutions allowed us to produce a collimated strontium atomic beam with a flux of 1.0\times10^13 s^-1 cm^-2 at the oven temperature of 450 °C, reached with an electrical power consumption of 36 W. The oven is based on a stainless-steel reservoir, filled with 6 g of metallic strontium, el…
▽ More
Here we describe a compact and efficient strontium oven well suited for laser-cooling experiments. Novel design solutions allowed us to produce a collimated strontium atomic beam with a flux of 1.0\times10^13 s^-1 cm^-2 at the oven temperature of 450 °C, reached with an electrical power consumption of 36 W. The oven is based on a stainless-steel reservoir, filled with 6 g of metallic strontium, electrically heated in a vacuum environment by a tantalum wire threaded through an alumina multi-bore tube. The oven can be hosted in a standard DN40CF cube and has an estimated continuous operation lifetime of 10 years. This oven can be used for other alkali and alkaline earth metals with essentially no modifications.
△ Less
Submitted 25 September, 2012;
originally announced September 2012.
-
High accuracy correction of blackbody radiation shift in an optical lattice clock
Authors:
Thomas Middelmann,
Stephan Falke,
Christian Lisdat,
Uwe Sterr
Abstract:
We have determined the frequency shift that blackbody radiation is inducing on the $5s^2$ $^1$S$_0$ -- $5s5p$ $^3$P$_0$ clock transition in strontium. Previously its uncertainty limited the uncertainty of strontium lattice clocks to $1\times10^{-16}$. Now the uncertainty associated to the black body radiation shift correction translates to $5\times 10^{-18}$ relative frequency uncertainty at room…
▽ More
We have determined the frequency shift that blackbody radiation is inducing on the $5s^2$ $^1$S$_0$ -- $5s5p$ $^3$P$_0$ clock transition in strontium. Previously its uncertainty limited the uncertainty of strontium lattice clocks to $1\times10^{-16}$. Now the uncertainty associated to the black body radiation shift correction translates to $5\times 10^{-18}$ relative frequency uncertainty at room temperature. Our evaluation is based on a measurement of the differential dc-polarizability of the two clock states and on a modeling of the dynamic contribution using this value and experimental data for other atomic properties.
△ Less
Submitted 29 October, 2012; v1 submitted 14 August, 2012;
originally announced August 2012.
-
Providing 1E-16 short-term stability of a 1.5 μm laser to optical clocks
Authors:
C. Hagemann,
C. Grebing,
T. Kessler,
St. Falke,
C. Lisdat,
H. Schnatz,
F. Riehle,
U. Sterr
Abstract:
We report on transferring 1E-16-level fractional frequency stability of a "master laser" operated at 1.5 μm to a "slave laser" operated at 698 nm, using a femtosecond fiber comb as transfer oscillator. With the 698 nm laser, the 1S_0 - 3P_0 clock transition of 87Sr was resolved to a Fourier-limited line width of 1.5 Hz (before: 10 Hz). Potential noise sources contributed by the frequency comb are…
▽ More
We report on transferring 1E-16-level fractional frequency stability of a "master laser" operated at 1.5 μm to a "slave laser" operated at 698 nm, using a femtosecond fiber comb as transfer oscillator. With the 698 nm laser, the 1S_0 - 3P_0 clock transition of 87Sr was resolved to a Fourier-limited line width of 1.5 Hz (before: 10 Hz). Potential noise sources contributed by the frequency comb are discussed in detail.
△ Less
Submitted 8 August, 2012;
originally announced August 2012.
-
The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems
Authors:
S. Schiller,
A. Görlitz,
A. Nevsky,
S. Alighanbari,
S. Vasilyev,
C. Abou-Jaoudeh,
G. Mura,
T. Franzen,
U. Sterr,
S. Falke,
Ch. Lisdat,
E. Rasel,
A. Kulosa,
S. Bize,
J. Lodewyck,
G. M. Tino,
N. Poli,
M. Schioppo,
K. Bongs,
Y. Singh,
P. Gill,
G. Barwood,
Y. Ovchinnikov,
J. Stuhler,
W. Kaenders
, et al. (6 additional authors not shown)
Abstract:
The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (mapping of the gravitational potential of Earth), and astronomy (providing local oscillators for radio…
▽ More
The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (mapping of the gravitational potential of Earth), and astronomy (providing local oscillators for radio ranging and interferometry in space). Within the ELIPS-3 program of ESA, the "Space Optical Clocks" (SOC) project aims to install and to operate an optical lattice clock on the ISS towards the end of this decade, as a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Undertaking a necessary step towards optical clocks in space, the EU-FP7-SPACE-2010-1 project no. 263500 (SOC2) (2011-2015) aims at two "engineering confidence", accurate transportable lattice optical clock demonstrators having relative frequency instability below 1\times10^-15 at 1 s integration time and relative inaccuracy below 5\times10^-17. This goal performance is about 2 and 1 orders better in instability and inaccuracy, respectively, than today's best transportable clocks. The devices will be based on trapped neutral ytterbium and strontium atoms. One device will be a breadboard. The two systems will be validated in laboratory environments and their performance will be established by comparison with laboratory optical clocks and primary frequency standards. In this paper we present the project and the results achieved during the first year.
△ Less
Submitted 17 June, 2012;
originally announced June 2012.
-
Long range transport of ultra cold atoms in a far-detuned 1D optical lattice
Authors:
Thomas Middelmann,
Stephan Falke,
Christian Lisdat,
Uwe Sterr
Abstract:
We present a novel method to transport ultra cold atoms in a focused optical lattice over macroscopic distances of many Rayleigh ranges. With this method ultra cold atoms were transported over 5 cm in 250 ms without significant atom loss or heating. By translating the interference pattern together with the beam geometry the trap parameters are maintained over the full transport range. Thus, the pr…
▽ More
We present a novel method to transport ultra cold atoms in a focused optical lattice over macroscopic distances of many Rayleigh ranges. With this method ultra cold atoms were transported over 5 cm in 250 ms without significant atom loss or heating. By translating the interference pattern together with the beam geometry the trap parameters are maintained over the full transport range. Thus, the presented method is well suited for tightly focused optical lattices that have sufficient trap depth only close to the focus. Tight focusing is usually required for far-detuned optical traps or traps that require high laser intensity for other reasons. The transport time is short and thus compatible with the operation of an optical lattice clock in which atoms are probed in a well designed environment spatially separated from the preparation and detection region.
△ Less
Submitted 16 April, 2012;
originally announced April 2012.
-
A sub-40 mHz linewidth laser based on a silicon single-crystal optical cavity
Authors:
T. Kessler,
C. Hagemann,
C. Grebing,
T. Legero,
U. Sterr,
F. Riehle,
M. J. Martin,
L. Chen,
J. Ye
Abstract:
State-of-the-art optical oscillators based on lasers frequency stabilized to high finesse optical cavities are limited by thermal noise that causes fluctuations of the cavity length. Thermal noise represents a fundamental limit to the stability of an optical interferometer and plays a key role in modern optical metrology. We demonstrate a novel design to reduce the thermal noise limit for optical…
▽ More
State-of-the-art optical oscillators based on lasers frequency stabilized to high finesse optical cavities are limited by thermal noise that causes fluctuations of the cavity length. Thermal noise represents a fundamental limit to the stability of an optical interferometer and plays a key role in modern optical metrology. We demonstrate a novel design to reduce the thermal noise limit for optical cavities by an order of magnitude and present an experimental realization of this new cavity system, demonstrating the most stable oscillator of any kind to date. The cavity spacer and the mirror substrates are both constructed from single crystal silicon and operated at 124 K where the silicon thermal expansion coefficient is zero and the silicon mechanical loss is small. The cavity is supported in a vibration-insensitive configuration, which, together with the superior stiffness of silicon crystal, reduces the vibration related noise. With rigorous analysis of heterodyne beat signals among three independent stable lasers, the silicon system demonstrates a fractional frequency stability of 1E-16 at short time scales and supports a laser linewidth of <40 mHz at 1.5 μm, representing an optical quality factor of 4E15.
△ Less
Submitted 5 January, 2012; v1 submitted 16 December, 2011;
originally announced December 2011.
-
Thermal noise in optical cavities revisited
Authors:
Thomas Kessler,
Thomas Legero,
Uwe Sterr
Abstract:
Thermal noise of optical reference cavities sets a fundamental limit to the frequency instability of ultra-stable lasers. Using Levin's formulation of the fluctuation-dissipation theorem we correct the analytical estimate for the spacer contribution given by Numata et al.. For detailed analysis finite-element calculations of the thermal noise focusing on the spacer geometry, support structure and…
▽ More
Thermal noise of optical reference cavities sets a fundamental limit to the frequency instability of ultra-stable lasers. Using Levin's formulation of the fluctuation-dissipation theorem we correct the analytical estimate for the spacer contribution given by Numata et al.. For detailed analysis finite-element calculations of the thermal noise focusing on the spacer geometry, support structure and the usage of different materials have been carried out. We find that the increased dissipation close to the contact area between spacer and mirrors can contribute significantly to the thermal noise. From an estimate of the support structure contribution we give guidelines for a low-noise mounting of the cavity. For mixed-material cavities we show that the thermal expansion can be compensated without deteriorating the thermal noise.
△ Less
Submitted 21 November, 2011;
originally announced November 2011.
-
Delivering pulsed and phase stable light to atoms of an optical clock
Authors:
Stephan Falke,
Mattias Misera,
Uwe Sterr,
Christian Lisdat
Abstract:
In optical clocks, transitions of ions or neutral atoms are interrogated using pulsed ultra-narrow laser fields. Systematic phase chirps of the laser or changes of the optical path length during the measurement cause a shift of the frequency seen by the interrogated atoms. While the stabilization of cw-optical links is now a well established technique even on long distances, phase stable links for…
▽ More
In optical clocks, transitions of ions or neutral atoms are interrogated using pulsed ultra-narrow laser fields. Systematic phase chirps of the laser or changes of the optical path length during the measurement cause a shift of the frequency seen by the interrogated atoms. While the stabilization of cw-optical links is now a well established technique even on long distances, phase stable links for pulsed light pose additional challanges and have not been demonstrated so far. In addition to possible temperature or pressure drift of the laboratory, which may lead to a Doppler shift by steadily changing the optical path length, the pulsing of the clock laser light calls for short settling times of stabilization locks. Our optical path length stabilization uses retro-reflected light from a mirror that is fixed with respect to the interrogated atoms and synthetic signals during the dark time. Length changes and frequency chirps are compensated for by the switching AOM. For our strontium optical lattice clock we have ensured that the shift introduced by the fiber link including the pulsing acousto optic modulator is below $2\cdot 10^{-17}$.
△ Less
Submitted 10 February, 2012; v1 submitted 18 August, 2011;
originally announced August 2011.