With the recent development in smart grid systems, there is now a growing interest in the development of on-line monitoring techniques. This is to reduce the maintenance costs as well as minimizing the probability of unexpected outages,... more
With the recent development in smart grid systems, there is now a growing interest in the development of on-line monitoring techniques. This is to reduce the maintenance costs as well as minimizing the probability of unexpected outages, or potentially to prevent catastrophic failures in the electrical network.
— Frequency response analysis (FRA) is a technique used to diagnose the mechanical integrity of a transformer winding; such diagnostic tools can be of enormous value since power transformers are a critical asset within any electrical... more
— Frequency response analysis (FRA) is a technique used to diagnose the mechanical integrity of a transformer winding; such diagnostic tools can be of enormous value since power transformers are a critical asset within any electrical network. To minimize the probability of an unexpected outage, or prevent a catastrophic failure, maintenance and monitoring of power transformers is essential for utilities. Over the past couple of decades, FRA has been utilized as an off-line diagnosis method. However, with the recent development in smart grid systems, there is now a growing interest in the development of on-line FRA techniques. This paper proposes a technique for in-service monitoring of power transformer winding deformation, which uses a broad frequency sine wave voltage excitation signal and high frequency Current Transformers (CT) in conjunction with the bushings test taps. Experiments using this system were conducted and then validated on a single-phase 22kV/110V voltage transformer.
— Frequency response analysis (FRA) is a technique used to diagnose the mechanical integrity of a transformer winding; such diagnostic tools can be of enormous value since power transformers are a critical asset within any electrical... more
— Frequency response analysis (FRA) is a technique used to diagnose the mechanical integrity of a transformer winding; such diagnostic tools can be of enormous value since power transformers are a critical asset within any electrical network. To minimize the probability of an unexpected outage, or prevent a catastrophic failure, maintenance and monitoring of power transformers is essential for utilities. Over the past couple of decades, FRA has been utilized as an off-line diagnosis method. However, with the recent development in smart grid systems, there is now a growing interest in the development of on-line FRA techniques. This paper proposes a technique for in-service monitoring of power transformer winding deformation, which uses a broad frequency sine wave voltage excitation signal and high frequency Current Transformers (CT) in conjunction with the bushings test taps. Experiments using this system were conducted and then validated on a single-phase 22kV/110V voltage transformer.
Research Interests: