F 7000 Brochure
F 7000 Brochure
F 7000 Brochure
Hitachis Superior Fluorescence Technology Has Created a New Generation of Fluorescence Spectrophotometers.
High S/N Ratio, Ultra-Fast Scanning, Compact Design, Multiple Accessories
P. 3~4
Extensive Application Capabilities
Industrial Materials, Pharmaceutical, and Biotechnology.
P. 5~6
Easy-to-Use Software
P. 7~8
High sensitivity measurement (S/N 800 RMS) (equivalent to S/N 250 peak to peak) 60,000 nm/min ultra-high scanning speed, ideal for 3-D measurement. Compact design (approx. 2/3 the size of the F-4500) A wide range of accessories accommodating various applications
1
P. 9~10
Stigmatic concave diffraction grating, mechanically ruled, resulting in a very bright monochromator of F-number 2.2.
Ruling engine.
A dividing engine for ruling diffraction gratings, invented in 1880s by Henry Augustus Rowland of Johns Hopkins University. Compared to a holographic grating, mechanically ruled gratings have the following advantages: (1) Mirror-finished groove surface results in high diffraction efficiency. (2) Groove spacing required for aberration correction can be adjusted, making it possible to have a greater correction effect. These characteristics of mechanically ruled gratings work well to create an excellent monochromator.
Diffraction grating
Fluorescent intensity
11012 mol/L
3-D Measurement
Data of fluorescent marker pen A 3-dimensional fluorescence spectrum can clearly distinguish slight differences that a 2-dimenstional spectrum cannot detect. Measurements can now be carried out with higher accuracy than before.
3 3-dimensional spectrum of fluorescent marker pen (green red) 3-dimensional spectrum of fluorescent marker pen (green) 2-dimensional spectrum (excitation wavelength 460nm) 4
Other functions
Automatic pre-scan function optimized for unknown sample measurement Ratio photometry (0 point correction) ensuring stable measurements High-resolution multi-stage slit with a resolution as small as 1nm Shutter control for minimizing sample deterioration
Fluorescent intensity
Calibration curve and spectrum overlay of fluorescein The automatic gain change-over function, a technique unique to Hitachi fluorescence spectrophotometers, has made it possible to generate calibration curves using up to 6-digit concentration values. An unknown sample can be quantitatively analyzed without additional sample preparation.
Biological Field
Measurement of intermolecular actions
FRET (Fluorescence Resonance Energy Transfer) and BRET (Bioluminescence Resonance Energy Transfer) The Model F-7000 can measure the intermolecular activiunit proteins of an ATP-active purine receptor. ties such as FRET and BRET. Shown below are fluoresData provided by Mr. Takaaki Koshimizu, Kyoto University Graduate School of Pharmaceutical Sciences Genomic Drug Discovery Science. cence spectra presenting the interactions between the sub-
100 80 60 40 20
100 80 60 40
P22e-YFP
20 460 480 500 520 540
Negative control
Scan speed: 12,000nm/min Excitation slit: 5.0nm Emission slit: 5.0nm Photomultiplier voltage: 400V Response: Automatic Spectrum correction: Activated Beam-cut filter (UV-39) used Photomultiplier R928F used The acquisition of these data was made possible by the 3-D measurement function and high-speed scanning capability of the F-7000.
460
480
500
520
540
EGF
Pharmaceutical Field
Phosphorescence measurement
Rare earth element complex (Eu chelate) The example below shows the phosphorescence spectrum and lifetime measurement of the Eu(tta)3 (TOPO)2 complex, a rare earth element. With the F-7000, the analysis of phosphorescence life of 1 ms order can be performed at room temperature without special accessories.
Ca2+ (nM)
200
100
50
100 sec
150
200
Micro-plate Accessory
Features Automatic measurement using a 96 well microplate is available. Used as an autosampler, allows wavelength scan, time scan, and 3-dimensional measurement. Can be used in conjunction with the polarization accessory.
Fluorescent intensity
Wavelength (nm)
New functions
Collective file conversion Multiple files can be converted simultaneously.
Condition setting
Pre-scan
Measurement
Measurement window
Measurement window
Spectrum measurement
Quantitative calculation
3-dimensional measurement
Automatic Polarization accessory for UV/VIS (5J0-0137) Automatic Polarization accessory for VIS (5J0-0138)
Used for the measurement, calculation and data recording of fluorescence polarization angle and fluorescence anisotropy. Optimized for the measurement of antigen-anti body reaction, biological cells, proteins, enzymes, and other samples for the medical and biochemical fields.
Wavelength range 380 - 730nm (5J0-0137) 260 - 700nm (5J0-0138) Polarizer rotation 0 to 90 automatic repetitive rotation on both excitation and emission sides Measured items Change of fluorescence polarization angle vs. time, fluorescence polarization angle, fluorescence anisotropy
Sub standard light source (115V) (5J0-0135) Sub standard light source (220-240V) (5J0-0136)
Required for correction of emission spectrum at longer wavelengths.
Emission side 200 to 800nm correction range (200 to 600nm with standard light source)
(Requires Photomultiplier R928F (650-1246).)
Band pass filter from 250 to 390nm only. Cut off filters for wavelengths shorter than 290, 310, 350, 390 and 430nm respectively.
Max. error due to cell changeover 3%, with the same sample and cell
(Cell must be prepared separately.)
Polarization accessory for UV/VIS (650-0155) Polarization accessory for VIS (650-0156)
Used to measure the polarization angle in the UV-VIS region (with 650-0155) and in the VIS region (with 650-0156). The 650-0156 provides a higher accuracy in VIS region.
Wavelength range 260 to 700nm (650-0155) 380 to 730nm (650-0156)
Compatible cells
10mm rectangular cell Test tube of outer dia. 10/12mm and height 105mm or less Error due to cell changeover Max. 3% in signal level difference with the same sample and 10mm rectangular cell
SPECIFICATIONS
DESCRIPTION S/N 800 or better (RMS) using Raman band of water Sensitivity S/N 250 or better (Peak to Peak) Excitation wavelength 350nm, bandpass 5nm, response 2s Minimum sample volume 0.6mL (in use of standard 10mm rectangular cell) Photometric principle Monochromatic light monitoring ratio calculation Light source 150W xenon lamp, self-deozonating lamp house Stigmatic concave diffraction grating: 900 lines/mm, F2.2 Monochromator Brazed wavelength: Excitation side 300nm, emission side 400nm Measuring wavelength range 200 to 750nm, and zero-order light (on both EX and EM) (Expandable up to 900nm with optional detector) Excitation side: 1, 2.5, 5, 10, 20nm Bandpass Emission side: 1, 2.5, 5, 10, 20nm Resolution 1.0nm Wavelength accuracy 1nm 30, 60, 240, 1,200, 2,400, 12,000, 30,000, Wavelength scan speed 60,000nm/min Wavelength drive speed 60,000nm/min Response from 0 to 98%: Response 0.002, 0.004, 0.01, 0.05, 0.1, 0.5, 2, 4 s Photometric value range 9999 to 9999 Data processing unit PC: Windows XP Professional Printer Printer compatible with Windows XP Spectrophotometer: 620 W 520 D 300 H mm Dimensions/weight (excluding protrusions)/41kg Working temperature 15 to 35C, 45 to 80% (condensation not /humidity allowed, 70% or less at 35C or higher) Power consumption 100, 115, 220, 230, 240 V AC, 50/60 Hz, 380 VA (spectrophotometer) FL Solutions program Standard software
* Microsoft, Windows, Microsoft Excel, Microsoft Word and Windows XP are registered trademarks, and other company names and merchandise names are registered trademarks or brand names of respective companies.
FUNCTIONS
ITEM 3-dimensional measurement DESCRIPTION Contour plotting (fluorescence/phosphorescence), birds eye view Readout of EX/EM spectra from contour Peak detection Calculation between files (+, , , ) Fluorescence/phosphorescence/luminescence spectra Synchronous spectra/repetitive measurement/CAT Excitation spectrum correction (200 to 600nm) Emission spectrum correction (200 to 600nm) Excitation longer wavelength spectrum correction (500 to 800nm) Emission longer wavelength spectrum correction (500 to 800nm)
Note: Sub standard light source (option) is necessary.
ITEM
Wavelength scan
Photometry mode
Others
Tracing, scale conversion, graph axis conversion Smoothing Calculation between files (+, , , ) Differentiation (first to fourth order) Contour plotting (fluorescence/phosphorescence), birds eye view Readout of time scan/EM spectra from contour Peak detection Calculation between files (+, , , ) Time scan fluorescence/phosphorescence measurement mode (minimum data interval 1.0ms) Phosphorescence attenuation curve measurement Rate calculation Tracing, scale conversion, graph axis conversion Smoothing Calculation between files (+, , , ) Differentiation (first to fourth order) Area calculation Quantitative analysis (fluorescence/phosphorescence/luminescence) Two/three-wavelength calculation Calibration curve (linear, quadratic, cubic, polygonal), factor enterable Peak ratio, peak area, quantization via differentiation Interruption, sample blank measurement, data deletion Calibration curve data correction, calibration curve tracing Cumulative data averaging Statistic calculation Automatic sensitivity measurement function Pre-scan Data transport and graph copying to Microsoft Excel Print preview function
NOTICE: For proper operation, follow the instruction manual when using the instrument. Specifications in this catalog are subject to change with or without notice, as Hitachi High-Technologies Corporation continues to develop the latest technologies and products for our customers.