Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

MAHMOUD EL-MOSHNEB ELEC.

CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL. 1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

THE CONTRACTOR WILL FURNISH SUPPLY & INSTALL THE FOLLOWING MATERIALS AND EQUIPMENT IN 'ACCORDANCE WITH THE CONTRACT SPECIFICATIONS, LOCAL CODES, REQUIREMENT AND WITH RELATIVE ELECTRICAL, HVAC, MECHANICAL & ARCHITECTURAL DRAWING. a. LIGHTING OUTLETS 1 LIGHTING FIXTURE OUTLET CONTROLLED BY ONE WAY LIGHTING SWITCH BY PVC INSULATED COPPER CONDUCTORS [(3X2.5)(mm2)] IN HEAVY RIGID PVC CONDUIT DIA.(20mm) FOR BOTH [MAIN/BRANCH] CIRCUIT STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. LIGHTING FIXTURE OUTLET CONTROLLED BY THREE WAY LIGHTING SWITCH BY PVC INSULATED COPPER CONDUCTORS [(3X2.5)(mm2)] IN HEAVY RIGID PVC CONDUIT DIA.(20mm) FOR MAIN CIRCUIT AND BY[(52.5)(mm2)]IN HEAVY RIGID PVC COUDUIT DIA. (25mm) FOR BRANCH CIRCUIT STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. LIGHTING FIXTURE OUTLET CONTROLLED BY IMPULSE PUSH BUTTON BY [TCCC-PVC/PVC][(26)(mm2)] PLUS [SCCC-PVC/PVC][(16)(mm2)(E)] IN HEAVY RIGID GALVANIZIED STEEL CONDUIT DIA.(1 INCH) AND ON CABLE TRAY FOR MAIN CIRCUIT AND BY [(22.5)(mm2)] IN HEAVY RIGID GALVANIZIED STEEL COUDUIT DIA. (3/4 INCH) AND ON CABLE TRAY FOR BRANCH CIRCUIT STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. LIGHTING FIXTURE OUTLET CONTROLLED BY TIMER LOCATED AT PANEL BOARD BY [TCCC-PVC/PVC][(26)(mm2)] PLUS [SCCC-PVC/PVC] [(16)(mm2)(E)] IN HEAVY RIGID GALVANIZIED STEEL CONDUIT DIA.(1INCH) AND ON CABLE TRAY STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. EXIT FIXTURE OUTLET BY PVC INSULATED COPPER CONDUCTORS [(32.5)(mm2)] IN HEAVY RIGID PVC CONDUIT DIA. (20mm) STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS.

147

PCS

PCS

96

PCS

18

PCS

PCS

B1 / 1

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

b. SOCKET AND POWER OUTLETS 6 SOCKET OUTLET BY PVC INSULATED COPPER CONDUCTORS [(34)(mm2)] IN HEAVY RIGID PVC CONDUIT DIA. (25mm) STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. SOCKET OUTLET BY PVC INSULATED COPPER CONDUCTORS [(36)(mm2)] IN HEAVY RIGID GALVANIZED STEEL CONDUIT DIA. (1 INCH) STARTING FROM SECONDARY DISTRIBATION BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. FAN OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY PVC INSULATED COPPER CONDUCTORS [(32.5)(mm2)] IN HEAVY RIGID PVC CONDUIT DIA.(20mm) FOR BOTH [MAIN/BRANCH] CIRCUIT STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN ON DRAWING AND SPECIFICATIONS. ELECTRIC WATER HEATER OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY PVC INSULATED COPPER CONDUCTERS [(34)(mm2)] IN HEAVY RIGID PVC DIA. (25mm) FOR BOTH [MAIN/BRANCH] CIRCUIT STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. (A/C) UNIT OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY PVC INSULATED COPPER CONDUCTERS [(34)(mm2)] IN HEAVY RIGID PVC CONDUIT DIA. (25mm) FOR BOTH [MAIN/BRANCH] CIRCUIT STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. (A/C) UNIT OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY PVC INSULATED COPPER CONDUCTERS [(36)(mm2)] IN HEAVY RIGID PVC CONDUIT DIA. (25mm) FOR BOTH [MAIN/BRANCH] CIRCUIT STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. EMPTY HEAVY RIGID PVC CONDUIT DIA. (20mm) COMPLETE WITH STEEL PULL WIRE STARTING FROM SAFETY FUSED DISCONNECTED SWITCH FED (A/C) UNIT TILL THERMOSTAT (PROVIDED AND INSTALLED BY OTHERS) AS SHOWN IN DRAWING AND SPECIFICATIONS.

101

PCS

13

PCS

26

PCS

PCS

10

PCS

11

15

PCS

12

125

L.M

B1 / 2

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

13

SUBMERSIBLE PUMP OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY PVC INSULATED COPPER CONDUCTORS [(36)(mm2)] IN HEAVY RIGID PVC CONDUIT DIA. (25mm) FOR BOTH [MAIN/BRANCH] CIRCUIT STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. ELECTRIC WATER HEATER OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY PVC INSULATED COPPER CONDUCTORS [(56)(mm2)] IN HEAVY RIGID PVC CONDUIT DIA. (32mm) FOR BOTH [MAIN/BRANCH] CIRCUIT STARTING FROM PANEL BOARD TILL OUTLET AS SHOWN IN DRAWING AND SPECIFICATIONS. CONTROL PANEL (PROVIDED AND INSTALLED BY OTHERS) FOR AUTOMATIC DOORS BY PVC INSULATED COPPER CONDUCTORS [(56) (mm 2)] IN HEAVY GALVANIZED STEEL CONDUIT DIA. (1.5 INCH) STARTING FROM SECONDARY DISTRIBUTION BOARD TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS LEKTROTUG EQUIPMENT OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY PVC INSULATED COPPER CONDUCTORS [(316)(mm 2)] IN HEAVY RIGID GALVANISED STEEL CONDUIT DIA. (1.5 INCH) FOR BOTH (MAIN/ BRANCH) CIRCUIT STARTING FROM SECONDARY DISTRIBUTION BOARD TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS. FAN OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY PVC INSULATED COPPER CONDUCTORS [(516)(mm2)] IN HEAVY RIGID GALVANISED STEEL CONDUIT DIA. (1.5 INCH) FOR BOTH (MAIN/BRANCH) STARTING FROM SECONDARY DISTRIBUTION BOARD TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS. CIRRUS AW (139) AND GULF STREAM (G550) EQUIPMENT OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY [MCCC-PVC/PVC][(416)(mm2)] ON CABLE TRAY FOR (MAIN/BRANCH) CIRCUIT STARTING FROM SECONDARY DISTRIBUTION BOARD TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS.

PCS

14

PCS

15

PCS

16

PCS

17

PCS

18

10

L.M

B1 / 3

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

19

CIRRUS AW (139) AND GULF STREAM (G550) EQUIPMENT OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY [MCCC-PVC/PVC][(416)(mm2)] ON (CABLE TRAY/TRENCH) FOR (MAIN/BRANCH) CIRCUIT STARTING FROM MAIN LOW VOLTAGE DISTRIBUTION BOARD TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS. (A/C) UNIT OUTLET FOR GULF STREAM (G550) EQUIPMENT CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY [MCCC-PVC/PVC][(395+50)(mm2)] ON (CABLE TRAY/TRENCH) FOR (MAIN/BRANCH) CIRCUIT STARTING FROM MAIN LOW VOLTAGE DISTRIBUTION BOARD TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS. HYDROULIC MULE EQUIPMENT OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY [MCCC-PVC/PVC][(395+50)(mm2)] ON (CABLE TRAY/TRENCH) FOR (MAIN/BRANCH) CIRCUIT STARTING FROM MAIN LOW VOLTAGE DISTRIBUTION BOARD TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS. AIR COMPRESSOR UNIT OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY [MCCC-PVC/PVC][(3150+70)(mm2)] ON (CABLE TRAY/TRENCH) AT INDOOR LOCATIONS AND IN HEAVY RIGID PVC CONDUIT DIA. (150mm) AT OUTDOOR LOCATIONS [PRICE INCLUDES ALL CIVIL WORKS i.e CONCRETE MANHOLE (6060)(CM) WITH HEAVY RIGID CONCRETE COVER ETC.]STARTING FROM MAIN LOW VOLTAGE DISTRIBUTION BOARD TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS. HYDROLUIC MULE EQUIPMENT OUTLET CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY [MCCC-PVC/PVC][(3150+70)(mm2)] ON (CABLE TRAY/TRENCH) AT INDOOR LOCATIONS AND IN HEAVY RIGID PVC CONDUIT DIA. (150mm) AT OUTDOOR LOCATIONS [PRICE INCLUDES ALL CIVIL WORKS i.e CONCRETE MANHOLE (6060)(CM) WITH HEAVY RIGID CONCRETE COVER ETC.]STARTING FROM MAIN LOW VOLTAGE DISTRIBUTION BOARD TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS.

10

L.M

20

10

L.M

21

10

L.M

22

120

L.M

23

160

L.M

B1 /4

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

24

(A/C) UNIT OUTLET FOR GULF STREAM (G550) EQUIPMENT CONTROLLED BY SAFETY FUSED DISCONNECTED SWITCH BY [MCCC-PVC/PVC][(3150+70)(mm2)] ON (CABLE TRAY/TRENCH) AT INDOOR LOCATIONS AND IN HEAVY RIGID PVC CONDUIT DIA. (150mm) AT OUTDOOR LOCATIONS [PRICE INCLUDES ALL CIVIL WORKS i.e CONCRETE MANHOLE (6060)(CM) WITH HEAVY RIGID CONCRETE COVER ETC.]STARTING FROM MAIN LOW VOLTAGE DISTRIBUTION BOARD TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS. c. LIGHTING SWITCHES AND PUSH BUTTENS

160

L.M

25

ONE WAY LIGHTING SWITCH , 10 AMP. (MIN.) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. ONE WAY LIGHTING SWITCH , 10 AMP. (MIN.) - IP 54 -AS SHOWN IN DRAWINGS AND SPECIFICATIONS. TWO WAY LIGHTING SWITCH , 10 AMP. EACH (MIN.) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. THREE WAY LIGHTING SWITCH , 10 AMP. (MIN.) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. IMPULSE PUSH BUTTON , 16 AMP. (MIN.) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. d. LIGHTING FIXTURES

36

PCS

26

PCS

27

PCS

28

PCS

29

PCS

30

LIGHTING FIXTURE WITH DESIGNATION (F1-2b) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. LIGHTING FIXTURE WITH DESIGNATION (F2-2b) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. LIGHTING FIXTURE WITH DESIGNATION (F4-4c) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. LIGHTING FIXTURE WITH DESIGNATION (I1) AS SHOWN IN DRAWINGS AND SPECIFICATIONS.

26

PCS

31

27

PCS

32

87

PCS

33

11

PCS

B1 / 5

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

34

LIGHTING FIXTURE WITH DESIGNATION (S1) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. LIGHTING FIXTURE WITH DESIGNATION (S2) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. LIGHTING FIXTURE WITH DESIGNATION (S3) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. EXIT SIGN AS SHOWN IN DRAWINGS AND SPECIFICATIONS. e. SOCKETS

72

PCS

35

12

PCS

36

30 6

PCS PCS

37

38

WALL SIMPLEX SOCKET , 16 AMP. (2POLE + EARTH) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. WALL DUPLEX SOCKET , 16 AMP. EACH (2POLE + EARTH) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. WALL DUPLEX SOCKET , 16 AMP. EACH (2POLE + EARTH) WITH DIFFERENT COLOUR FOR COMPUTER SET AS SHOWN IN DRAWINGS AND SPECIFICATIONS. WALL DUPLEX SOCKET , 16 AMP. EACH (2POLE + EARTH) - IP 54 AS SHOWN IN DRAWINGS AND SPECIFICATIONS. WALL INDUSTRIAL SOCKET , 32 AMP. (2POLE + EARTH) - IP 66 AS SHOWN IN DRAWINGS AND SPECIFICATIONS. f. SAFELTY FUSED DISCONNECTED SWITCH

47

PCS

39

27

PCS

40

19

PCS

41

PCS

42

13

PCS

43

SAFETY FUSED DISCONNECTED SWITCH , 15 AMP. (2POLE + EARTH) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH, 15AMP. IP 54-(2POLE+EARTH) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH , 20 AMP. (2POLE + EARTH) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH , 25 AMP. (2POLE + EARTH) AS SHOWN IN DRAWINGS AND SPECIFICATIONS.

24

PCS

44

PCS

45

10

PCS

46

PCS

B1 / 6

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

47

SAFETY FUSED DISCONNECTED SWITCH , 30 AMP. (2POLE + EARTH) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH , 30 AMP. (2POLE+EARTH) IP 54 AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH , 40 AMP. (2POLE + EARTH) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH , 50 AMP. (2POLE + EARTH) IP 66 - AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH , 30 AMP. (3PHASE + NEUTRAL + EARTH) - IP 66 - AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH , 40 AMP, (3 PHASE + NEUTRAL + EARTH) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH , 50 AMP. (3PHASE + NEUTRAL + EARTH) - IP 66 - AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH , 150 AMP. (3PHASE+ NEUTRAL + EARTH) - IP 66 - AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SAFETY FUSED DISCONNECTED SWITCH , 200 AMP. (3PHASE + NEUTRAL + EARTH) - IP 66 - AS SHOWN IN DRAWINGS AND SPECIFICATIONS. g. UPS

PCS

48

PCS

49

11

PCS

50

PCS

51

PCS

52

PCS

53

PCS

54

PCS

55

PCS

56

(UPS) - 3PHASE / 3PHASE - 10KVA AS SHOWN IN DRAWINGS AND SPECIFICATIONS. h. PANEL BOARDS AND DISTRIBUTION BOARDS

PCS

57

PANEL BOARD WITH DESIGNATION (EM - LP - VIP) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. PANEL BOARD WITH DESIGNATION (EM - LP - ST) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. B1 / 7

PCS

58

PCS

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

59

PANEL BOARD WITH DESIGNATION (EM - LP - MEC) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. PANEL BOARD WITH DESIGNATION (EM - LP - HANG) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. PANEL BOARD WITH DESIGNATION (EM - PP - HANG) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. PANEL BOARD WITH DESIGNATION (LP - U - VIP) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. PANEL BOARD WITH DESIGNATION (LP - U) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SECONDARY DISTRIBUTION BOARD WITH DESIGNATION (EM-SDB-VIP) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SECONDARY DISTRIBUTION BOARD WITH DESIGNATION (EM-SDB-ST) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. SECONDARY DISTRIBUTION BOARD WITH DESIGNATION (SDB-PP-VIP) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. EMERGENCY MAIN DISTRIBUTION BOARD WITH DESIGNATION (EM - MDB) COMPLETE WITH AUTOMATIC TRANSFER SWITCH WITH DESIGNATION (ATS) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. MAIN LOW VOLTAGE DESIGNATION BOARD WITH DESIGNATION (LT - MDB) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. i. POWER FEEDER

PCS

60

PCS

61

PCS

62

PCS

63

PCS

64

PCS

65

PCS

66

PCS

67

PCS

68

PCS

69

[MCCC-PVC/PVC][(46)(mm2)] ON (CABLE TRAY / TRENCH) AT INDOOR LOCATIONS AND IN HEAVY RIGID PVC CONDUIT DIA. (150mm) [THE SAME CONDUIT WITH OTHER EMERGENCY FEEDERS] AT OUTDOOR LOCATIONS [PRICE INCLUDES ALL CIVIL WORKS i.e CONCRETE MANHOLE (6060)(cm) WITH HEAVYRIGID CONCRETE COVER ETC.] FROM PANEL BOARD WITH DESIGNATION (LP-U) TO FEED PANEL BOARD WITH DESIGNATION (LP - U - VIP) AS SHOWN IN DRAWINGS AND SPECIFICATIONS

160

L.M

B1 / 8

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

70

[MCCC-PVC/PVC][(410)(mm2)] ON (CABLE TRAY / TRENCH) FROM EMERGENCY MAIN DISTRIBUTION BOARD WITH DESIGNATION (EM - MDB) TO FEED PANEL BOARD WITH DESIGNATION (LP-U) VIA (UPS) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. [MCCC- PVC/PVC][(410)(mm2)] ON (CABLE TRAY / TRENCH) AT INDOOR LOCATIONS AND IN HEAVY RIGID PVC CONDUIT DIA. (50mm) AT OUTDOOR LOCATIONS [PRICE INCLUDES ALL CIVIL WORKS l.e CONCRETE MANHOLE (6060)(cm) WITH HEAVY RIGID CONCRETE COVER .. ETC.] FROM EMERGENCY MAIN DISTRIBUTION BOARD WITH DESIGNATION (EM - MDB) TO FEED PANEL BOARD WITH DESIGNATION (EM - LP - MEC) AS SHOWN IN DRAWINGS AND SPECIFICATIONS.

10

L.M

71

LUM

LUM

[MCCC - PVC/PVC][(370+35)(mm2) ON CABLE TRAY FROM CORRESPONDING SECONDARY DISTRIBUTION BOARD TO FEED THE FOLLOWING AS SHOWN IN DRAWINGS AND SPECIFICATIONS AND SPECIFICATIONS :72-1 PANEL BOARD WITH DESIGNATION (EM - LP - VIP). 72-2 PANEL BOARD WITH DESIGNATION (EM - LP - ST). [MCCC- PVC/PVC][(395+50)(mm2)] ON (CABLE TRAY / TRENCH) FROM EMERGENCY MAIN DISTRIBUTION BOARD WITH DESIGNATION (EM - MDB) TO FEED THE FOLLOWING AS SHOWN IN DRAWINGS AND SPECIFICATIONS : 73-1 PANEL BOARD WITH DESIGNATION (EM - LP - HANG). 73-2 SECONDARY DISTRIBUTION BOARD WITH DESIGNATION (EM - SDB - ST). 74 [MCCC- PVC/PVC][(395+50)(mm2)] ON (CABLE TRAY / TRENCH) AT INDOOR LOCATIONS AND IN HEAVY RIGID PVC CONDUIT DIA.(150mm) AT OUTDOOR LOCATIONS [PRICE INCLUDES ALL CIVIL WORKS .. i.e CONCRETE MANHOLE (6060)(cm) WITH HEAVY RIGID CONCRETE COVER ETC.] FROM MAIN LOW VOLTAGE DISTRIBUTION BOARD WITH DESIGNATION (LT-MDB) TILL SECONDARY DISTRIBUTION BOARD WITH DESIGNATION (SDB - PP - VIP) AS SHOWN IN DRAWINGS AND SPECIFICATIONS [MCCC- PVC/PVC][(3120+70)(mm2)] ON (CABLE TRAY / TRENCH) FROM EMERGENCY MAIN DISTRIBUTION BOARD WITH DESIGNATION (EM-MDB) TILL PANEL BOARD WITH DISTRIBUTION (EM - PP - HANG) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. 73

72

7 7

L.M L.M

7 7

L.M L.M

160

L.M

75

L.M

B1 / 9

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

[MCCC- PVC/PVC][(3150+70)(mm2)] ON (CABLE TRAY / TRENCH) AT INDOOR LOCATIONS AND IN HEAVY RIGID PVC CONDUIT DIA.(150mm) AT OUTDOOR LOCATIONS [PRICE INCLUDES ALL CIVIL WORKS .. i.e CONCRETE MANHOLE (6060)(cm) WITH HEAVY RIGID CONCRETE COVER ETC.] FROM EMERGENCY MAIN DISTRIBUTION BOARD WITH DESIGNATION (EM-MDB) TO FEED THE FOLLOWING AS SHOWN IN DRAWINGS AND SPECIFICATIONS : 76-1 SECONDARY DISTRIBUTION BOARD WITH DESIGNATION (EM-SDB-VIP). 76-2 CONTROL PANEL FOR FIRE FIGHTING SYSTEM (PROVIDED AND INSTALLED BY OTHERS). 77 QTY (2) [MCCC - PVC/PVC][(3300+150)(mm2)] ON ((CABLE TRAY / TRENCH) FROM MAIN LOW VOLTAGE DISTRIBUTION BOARD WITH DESIGNATION (LT-MDB) TO EMERGENCY MAIN DISTRIBUTION BOARD WITH DESIGNATION (EM-MDB) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. QTY (2) [MCCC - PVC/PVC][(3300+150)(mm2)] ON ((CABLE TRAY / TRENCH) AT INDOOR LOCATIONS AND IN QTY (2) HEAVY RIGID PVC CONDUIT DIA. (150mm) AT OUTDOOR LOCATIONS [PRICE INCLUDES ALL CIVIL WORKS .. i.e CONCRETE MANHOLE (6060)(cm) WITH HEAVY RIGID CONCRETE COVER ETC.] FROM EMERGENCY MAIN DISTRIBUTION BOARD WITH DESIGNATION (EM-MDB)TILL CONTROL PANEL FOR EMERGENCY GENERATING UNIT AS SHOWN IN DRAWINGS AND SPECIFICATIONS. QTY (2) EMPTY HEAVY RIGID PVC CONDUIT DIA. (150mm) FOR MAIN INCOMING POWER FEEDERS FROM MAIN INTAKE POWER POINT (LOCATION TO BE DETERMINED BY OTHERS) TO MAIN LOW VOLTAGE DISTRIBUTION BOARD WITH DESIGNATION (LT-MDB) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. j. EARTHING FEEDERS 80 [SCCC - PVC/PVC][(16)(mm2)(E)] ON CABLE TRAY STARTING FROM CORRESPENDING EARTHING BAR LOCATED AT CORRESPONDING ELECTRIC ROOM TILL THE PANEL BOARD WITH DESIGNATION (LP-U-VIP) AS SHOWN IN DRAWINGS AND SPECIFICATIONS.

76

160 LUM

L.M LUM

L.M

78

50

L.M

79

LUM

LUM

10

L.M

B1 / 10

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

[SCCC - PVC/PVC][(110)(mm2)(E)] ON CABLE TRAY STARTING FROM CORRESPENDING EARTHING BAR LOCATED AT CERRESPONDING ELECTRIC ROOM TILL THE FOLLOWING AS SHOWN IN DRAWINGS AND SPECIFICATIONS ; 81-1 PANEL BOARD WITH DESIGNATION (LP-U). 81-2 UPS. 81-3 PANEL BOARD WITH DESIGNATION (EM-LP-MEC). [SCCC - PVC/PVC][(116)(mm2)(E)] ON CABLE TRAY STARTING FROM CORRESPENDING EARTHING COPPER BAR LOCATED AT CORRESPONDING (ELEC./COMPRESSOR/GENERATOR) ROOM TILL THE FOLLOWING AS SHOWN IN DRAWINGS AND SPECIFICATIONS. 82-1 CIRRUS AW(139) AND GULF STREAM (G550) EQUIPMENT LOCATED AT (VIP) WING. 82-2 CIRRUS AW(139) AND GULF STREAM (G550) EQUIPMENT LOCATED AT STAFF WING. [SCCC - PVC/PVC] [(135) (mm 2) (E)] ON CABLE TRAY STARTING FROM CORRESPONDING EARTHING BAR LOCATED AT CORRESPONDING ELECTRIC ROOM TILL THE FOLLOWING AS SHOWN IN DRAWINGS AND SPECIFICATIONS. 83-1 PANEL BOARS WITH DESIGNATION (EM - LP - VIP) 83-2 PANEL BOARS WITH DESIGNATION (EM - LP - ST) 83 84 [SCCC - PVC/PVC][(150)(mm2)(E)] ON CABLE TRAY STARTING FROM CORRESPENDING EARTHING COPPER BAR LOCATED AT CORRESPONDING (ELEC./COMPRESSOR/GENERATOR) ROOM TILL THE FOLLOWING AS SHOWN IN DRAWINGS AND SPECIFICATIONS. A/C UNIT FOR GULF STREAM (G550) EQUIPMENT. HYDROULIC MULE EQUIPMENT AT STUFF WING. PANEL BOARD WITH DESIGNATION (EM-LP-HANG). SECONDARY DISTRIBUTION BOARD WITH DESIGNATION (EM-SDB-ST). SECONDARY DISTRIBUTION BOARD WITH DESIGNATION (SDB-PP-VIP). [SCCC - PVC/PVC] [(150)(mm 2) (E)] IN HEAVY RIGID PVC CONDUIT DIA. (50mm) FOR BONDING STEEL COLUMNS AS SHOWN IN DRAWINGS AND SPECIFICATIONS. 82

81

10 10 LUM

L.M L.M LUM

10 10

L.M L.M

7 10

L.M L.M

84-1 84-2 84-3 84-4 84-5 85

10 10 7 7 7

L.M L.M L.M L.M L.M

LUM

LUM

B1 / 11

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

86

86-1 86-2 86-3 86-4 86-5 86-6 86-7 86-8

[SCCC - PVC/PVC][(170)(mm2)(E)] ON CABLE TRAY STARTING FROM CORRESPENDING EARTHING COPPER BAR LOCATED AT CERRESPONDING (ELEC./COMPRESSOR/GENERATOR) ROOM TILL THE FOLLOWING AS SHOWN IN DRAWINGS AND SPECIFICATIONS. AIR COMPRESSOR UNIT. HYDROULIC MULE AT (VIP) WING. (A/C) UNIT FOR GULF STREAM (G550) EQUIPMENT AT (VIP) WING. SECONDARY DISTRIBUTION BOARD WITH DESIGNATION (EM-PP-HANG). SECONDARY DISTRIBUTION BOARD WITH DESIGNATION (EM-SDB-VIP). CONTROL PANEL FOR FIRE FIGHTING SYSTEM (PROVIDED AND INSTALLED BY OTHERS) EMERGENCY MAIN DISTRIBUTION BOARD WITH DESIGNATION (EM-MDB). MAIN LOW VOLTAGE DISTRIBUTION BOARD WITH DESIGNATION (LT-MDB). k.EARTHING PITS

10 10 10 7 7 LUM 7 7

L.M L.M L.M L.M L.M LUM L.M L.M

87

EARTHING PIT BY SCCC - PVC/PVC [(150) (mm 2) (E)] IN HEAVY RIGIDE PVC CONDUIT DIA. (50mm) [PRICE INCLUDES ALL CIVIL WORKS i.e CONCRETE MANHOLE (3030) (cm) WITH HEAVY RIGIDE CONCRETE COVER etc.] AS SHOWN IN DRAWINGS AND SPECIFICATIONS EARTHING PIT BY QTY (2) SCCC - PVC/PVC [(170) (mm 2) (E)] IN QTY (2) HEAVY RIGID PVC CONDUIT DIA. (50mm) COMPLETE WITH EARTHING COPPER BAR (800505mm) AND TESTING LINKS INSIDE CORRESPONDING (ELEC./ COMPRESSOR/ GENERATOR) ROOM [PRICE INCLUDES ALL CIVIL WORKS i.e CONCRETE MANHOLE (3030) (cm) WITH HEAVY RIGID CONCRETE COVER ETC.] AS SHOWN IN DRAWINGS AND SPECIFICATIONS. l. CABLE TRAY

PCS

88

PCS

89

89-1 89-2 89-3 89-4 89-5

HOT DIPPED GALVANIZED HEAVY RIGID STEEL CABLE TRAY WITH THE FOLLOWING DIMENSIONS AS SHOWN IN DRAWINGS AND SPECIFICATIONS. (10100.2) cm (15100.2) cm (20100.2) cm (40100.2) cm (60100.2) cm

30 5 10 20 140

L.M L.M L.M L.M L.M

B1 / 12

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

m. SPARE EXTERNAL CONDUITS 90 EMPTY HEAVY RIGID PVC CONDUIT DIA. (150mm) AS SHOWN IN DRAWINGS AND SPECIFICATIONS. n.TELEPHONE & DATA OUTLETS & CABLES AND PATCH PANEL. 91 TELEPHONE SOCKET OUTLET BY TELEPHONE CABLE UTP (4PAIR) (CAT 6A) WALL MOUNTED IN HEAVY RIGID PVC CONDUIT DIA. (20mm) STARTING FROM CORRESPONDING TELEPHONE PATCH PANEL TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS. DATA SOCKET OUTLET BY TELEPHONE CABLE UTP (4PAIR) (CAT 6A) WALL MOUNTED IN HEAVY RIGID PVC CONDUIT DIA. (20mm) STARTING FROM CORRESPONDING TELEPHONE PATCH PANEL TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS. TELEPHONE SIMPLEX SOCKET (RJ45) (CAT.6A) WALL MOUNTED AS SHOWN IN DRAWINGS AND SPECIFICATIONS. DATA DUPLEX SOCKET (RJ45) (CAT.6A) WALL MOUNTED AS SHOWN IN DRAWINGS AND SPECIFICATIONS. TELEPHONE PATCH PANEL WITH DESIGNATION (TEL - VIP) - 25 PAIR -IN ACCORDANCE WITH (CAT.6A) STANDARDS AS SHOWN IN DRAWINGS AND SPECIFICATIONS. TELEPHONE PATCH PANEL WITH DESIGNATION (TEL - ST) - 50 PAIR -IN ACCORDANCE WITH (CAT.6A) STANDARDS AS SHOWN IN DRAWINGS AND SPECIFICATIONS. DATA PATCH PANEL (6 PORT) FOR (VIP) WING AS SHOWN IN DRAWINGS AND SPECIFICATIONS. DATA PATCH PANEL (12 PORT) FOR STAFF WING AS SHOWN IN DRAWINGS AND SPECIFICATIONS.

LUM

LUM

30

PCS

92

19

PCS

93

30

PCS

94

19

PCS

95

PCS

96

PCS

97

PCS

98

PCS

B1 / 13

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

99

FIBER OPTICAL TELEPHONE CABLE (25PAIR) IN HEAVY RIGIDE PVC CONDUIT DIA.(50mm) [PRICE INCLUDES ALL CIVIL WORKS i.e CONCRETE HANDHOLE (3030)(cm) WITH HEAVY RIGIDE CONCRETE COVER . ETC.] FROM TELEPHONE PATCH PANEL WITH DESIGNATION (TEL - ST) TO TELEPHONE PATCH PANEL WITH DESIGNATION (TEL -VIP) AS SHOWN IN DRAWINGS AND SPECIFICATIONS.

160

L.M

100 EMPTY HEAVY RIGID PVC CONDUIT DIA. (50mm) FROM MAIN INTAKE TELEPHONE POINT (LOCATION TO BE DETERMINED BY OTHERS) TO LIGHT CURRENT ROOM AT STAFF WING AS SHOWN IN DRAWINGS AND SPECIFICATIONS. 101 EMPTY HEAVY RIGID PVC CONDUIT DIA. (50mm) FROM MAIN INTAKE DATA POINT (LOCATION TO BE DETERMINED BY OTHERS) TO THE FOLLOWING:101-1 DATA PATCH PANEL AT STUFF WING 101-2 DATA PATCH PANEL AT (VIP) WING o. FIRE ALARM 102 FIRE ALARM OUTLET BY FIRE ALARM CABLE IN HEAVY RIGID GALVANIZED STEEL CONDUIT DIA. (1 INCH) STARTING FROM FIRE ALARM MAIN PANEL TILL OUTLET AS SHOWN IN DRAWINGS AND SPECIFICATIONS.
2 103 FIRE ALARM SIREN OUTLET BY PVC COPPER CABLE [(22.5)(mm )] IN HEAVY GALVANIZED STEEL CONDUIT DIA. (1 INCH) STARTING FROM FIRE ALARM MAIN PANEL TILL OUTLET AS AHOWN IN DRAWINGS AND SPECIFICATIONS.

LUM

LUM

LUM LUM

LUM LUM

54

PCS

PCS

104 ADDRESSABLE MULTI - SENSOR FIRE ALARM DETECTOR AS SHOWN IN DRAWINGS AND SPECIFICATIONS. 105 ADDRESSABLE HEAT FIRE ALARM DETECTOR AS SHOWN IN DRAWINGS AND SPECIFICATIONS. 106 ADDRESSABLE MANUAL STATION AS SHOWN IN DRAWINGS AND SPECIFICATIONS.

35

PCS

PCS

PCS

B1 / 14

MAHMOUD EL-MOSHNEB ELEC.CONSULTANT ENGINEER

CLEOPATRA AVIATION CO. AIRCRAFT HANGER CAIR AIRPORT

TENDER ISSUE NOV. 2010

BILL.1

ITEM

DESCRIPTION

QTY

UNIT

RATE AMOUNT L.E L.E

107 ADDRESSABLE TRANSMISSION BEAM DETECTOR AS SHOWN IN DRAWINGS AND SPECIFICATIONS. 108 ADDRESSABLE REFLECTOR BEAM AS SHOWN IN DRAWINGS AND SPECIFICATIONS. 109 FIRE ALARM SIREN AS SHOWN IN DRAWINGS AND SPECIFICATIONS. 110 FIRE ALARM PANEL AS SHOWN IN DRAWINGS AND SPECIFICATIONS. p. SPARL EXTERNAN CONDUIT 111 EMPTY HEAVY RIGID PVC CONDUIT DIA. (50mm) AS SHOWN IN DRAWINGS AND SPECIFICATIONS.

PCS

3 7 1

PCS PCS PCS

LUM

LUM

TOTAL B1 / 15