Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

To-218 Isolated SCR: Hutson Industries, Inc

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Hutson Industries,Inc.

1000 Hutson Circle


Frisco, TX 75034
TEL:(972)335-8600
Fax:(972)377-2197
TO-218 ISOLATED*
SCR
1. CATHODE
2. ANODE
3. GATE
SYM. INCHES
A 0.610 0.628
B 0.625 0.650
C 0.480 0.500
D 0.500 0.610
E 0.040 0.065
F 0.205 0.225
G 0.165 0.200
H 0.053 0.065
I 0.015 0.025
J 0.095 0.126
MAXIMUM RATINGS SYMBOL DEVICE NUMBERS UNITS
Repetitive Peak Off-State Voltage and Repetitive Peak Voltage.
Gate open, and Tj=110C /VDRM
50
100
200
400
600
HIS025
HIS125
HIS225
HIS425
HIS625
HIS040
HIS140
HIS240
HIS440
HIS640
HIS065
HIS165
HIS265
HIS465
HIS665
VOLT
RMS On-State Current at TC=80 C
and Conduction Angle of 180
It(RMS) 25 40 65 AMP
Peak Surge (Non-Repetitive) On-State
Current, One-Cycle, at 50Hz or 60 Hz
ITSM 250 400 650 AMP
Peak Gate-Trigger Current for 3sec. Max. IGTM 5 5 5 AMP
Peak Gate-Power Dissipation at IGT < IGTM PGM 20 20 20 WATT
Average Gate-Power Dissipation PG(AV) 0.5 0.5 0.5 WATT
Storage Temperature Range Tstg -40 to +150 C
Operating Temperature Range, Tj Toper -40 to +110 C
Peak Off-State Current, Gate Open
TC=110 C VDRM &VRRM=Max. Rating
IDRM 0.5 0.5 0.5
mA
MAX.
Maximum On-State Voltage, (PEAK) at TC=25C, and IT =
Rated Amps
VTM 1.6 1.8 1.8
VOLT
MAX
DC Holding Current, Gate Open
and TC = 25C
IHO 100 100 100
mA
MAX.
Critical Rate-Of-Rise of Off-State Voltage,Gate Open, TC =
110C
Critical
dv/dt
200 200 200 V/sec.
DC Gate Trigger Current for Anode Voltage = 12VDC, RL =
60 ohm and at TC=25 C
IGT 40 40 50
mA
MAX.
DC Gate-Trigger Voltage for Anode Voltage=12VDC, RL = 60
ohm and at TC=25C
VGT 2 2 2
VOLT
MAX
Gate-Controlled Turn-on Time for
t D + t R, IGT=150mA and TC = 25C
Tgt 2.5 2.5 2.5 sec.
Thermal Resistance, Junction-to-Case RqJ-C 1.1 0.95 1.0 C/WATT TYP
Notes: *All Hutson Isolated TO-218 devices are UL recognized. UL Number E95589 (N)