Liebert: Continuous Protection For Your Business
Liebert: Continuous Protection For Your Business
Liebert: Continuous Protection For Your Business
LM Series
Power Protection
THE LM SERIES:
The LM Series can be a facility-wide product family and may be installed from service entrances to distribution panels to branch panels. Commercial buildings Institutional facilities Industrial plants Any facility that has an environment with electronics-based equipment
At A Glance
Modular design allows for flexibility Surge suppression range of 60 to 500 kA per phase Industry's highest surge current repeatability Internal/external monitoring, including neutral to ground UL rated 200k AIC with component level fusing for safe operation All modes of protection standard, any combination optional Sine wave tracking, EMI/RFI filtering UL 1449 (second edition), UL1283 and CUL listed ANSI/IEEE C62.11, C62.41, C62.45 categories A, B, and C3 tested NEMA 12 enclosure with 3R, 4, and 4X options available. 5-year warranty 2 sets of Form C dry contacts Audible alarm Choice of options Disconnect Transient counter Remote monitor panel Test set Tested to NEMA LS1
STANDARD FEATURES
Unit Status Indicators The unit has an integral status circuit that monitors the operational status of all modes of protection, including Line to Neutral, Line to Ground, and Neutral to Ground. In the unlikely event that protection is reduced, the green LED will go out and the red LED will be lit. LED indication shall be provided internal and external to the product. Enclosure The unit is housed in a heavy duty, steel, NEMA 12 dust-tight, drip-tight enclosure. Undervoltage Detection LED will indicate an undervoltage at 70% of nominal. Warranty Phase and Power Loss Monitoring LED will indicate a loss of any phase or loss of power. Noise Attentuation The filter provides insertion loss with a maximum of 60 dB from 100 kHz to 100 MHz per 50 Ohm Insertion Loss Methodology from MIL Std. 220A. Overcurrent Protection All components are individually fused and unit is UL rated for 200k AIC for safe operation. Life Cycle Testing The system is life cycle tested to survive multiple 10kA, 20KV, IEEE C62.41 Category C3 transients with less than 5% degradation of clamping voltage. The minimum number of surges the unit shall be able to protect against is 8,000 per phase. Form C Dry Contacts Two sets of electronically isolated form C dry contacts are provided, (one normally open and normally closed for remote monitoring). A full five-year parts warranty. Audible Alarm The system is equipped with an audible alarm activated when summary alarm contacts are activated. An ON/OFF switch is provided to silence the alarm, and an alarm push-to-test switch to test the alarm function. A visible LED confirms whether alarm is on or disabled. Both switches and audible alarm will be located on the panel's front cover. Agency Listing The specified unit is UL 1449 (Second Edition) Listed, UL 1283 Listed, and CUL Listed. Control Concepts/Liebert is also company certified ISO 9001 for manufacturing, design, and service.
OPTIONAL FEATURES
Integral Fused Disconnect A 200k AIC integral fused disconnect switch located in line with the system enclosure with an external manual operator. Transient Counter The system can be equipped with a transient counter which totals transient surges that deviate from the sine wave envelop by more than 125 volts. The counter is located on the unit's front cover and features a six digit LCD, lithium batteries (with 10-year life), and remotely located reset switches. Test Point/Kit The unit can include a test point and diagnostic test kit option. The test kit (TS-X) uses a microprocessor monitor and controlled pulse generator to induce a high voltage transient, which drives the surge protective device into clamping. This test kit allows the end user to test and monitor in every mode (L-N, N-G, L-G). Remote Monitor Panel A self contained, UL Listed monitoring panel. Input power to the monitoring panel is equipped with a 6-foot power cord with a 3 NEMA 5-15 plug. The monitor has an audible alarm, red and green LEDs silence switch, and a test switch.
SPECIFICATIONS
LM Series Surge Suppression
Maximum Continuous Operating Voltage (MCOV) Fault Current Rating (AIC) Operating Frequency Range Response Time Operating Humidity Status Indication Certifications Enclosure Warranty
48dB
60kA/mode 060 120-120V 80kA/mode 080 208-208V 100kA/mode 100 220-220V 125kA/mode 125 230-230V
N Standard Monitoring System, S LEDs, Audible Alarm, Disconnect R Dual Form C Contacts LEDs, Audible Alarm, C Surge Counter, Dual Form C Contacts
200kA/mode 200 277-277V Three Phase Delta Hi-leg 3W+gnd H 225kA/mode 225 480-480V 250kA/mode 250 600-600V
All
20
16
21.25
10
0.31
45
Power Protection
L I E B E R T CO R P O R AT I O N
1050 DEARBORN DRIVE P.O. BOX 29186 COLUMBUS, OHIO 43229 800.877.9222 PHONE (U.S. & CANADA ONLY) 614.888.0246 PHONE (OUTSIDE U.S.) 614.841.6022 FAX VIA LEONARDO DA VINCI 8 ZONA INDUSTRIALE TOGNANA 35028 PIOVE DI SACCO (PD) ITALY 39 049 9719 111 PHONE 39 049 5841 257 FAX 23/F ALLIED KAJIMA BLDG. 138 GLOUCESTER ROAD WANCHAI HONG KONG 852 2 572 2201 PHONE 852 2 831 0114 FAX
24
7 WARRANT Y SUPPORT
TECHNICAL SUPPORT
800 288 6169 PHONE 607 724 2484 607 722 8713 FAX
While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 2003 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. Liebert and the Liebert logo are registered trademarks of the Liebert Corporation. Keeping Business in Business is a registered trademark of the Liebert Corporation. The Emerson logo is a trademark and service mark of Emerson Electric Co. SL-22055 (9/03) Printed in USA
No organization in the world today has a better understanding of exactly what it takes to keep critical information and industrial processes operating continuously than Liebert.
www.liebert.com