The CMG-5TD combines the CMG-5td threeaxis strong motion accelerometer with the CMGDM24/3 24-bit Digitiser Module in a single, sealed case. An internal dc-dc converter ensures a completely isolated sensor system and allows the system to operate from 10 to 36 Volts. The external GPS receiver/antenna can be placed up to 50 meters from the digital sensor. The CMG-5TD sensor system has an extremely large dynamic range, combining the 140dB sensor with the 132dB noise-free resolution digitizer. The CMG-5T transducers use low noise components, high feedback loop gain, and computer-aided design to produce a linear, wide dynamic range, precision transducer. Full-scale low-gain sensitivity can be specified as 0.1, 0.2, 0.4, 0.5, 1.0, 2.0 or 4.0 g. The standard frequency pass band is flat to acceleration from dc to 100 Hz. Other low pass corners from 50 Hz to 100 Hz can be ordered. The CMG-5TD Accelegraph has 2 separate RS232 outputs. While one RS232 port can be used for data transmission and configuration of the accelegraph parameters, the second RS-232 port (Monitor port) can be used locally to check system operation and additionally configure the system if so desired. Up to four simultaneous rates can be selected from 1 to 200 samples per second. (options from 1 to 1000 samples per second are available - please consult the factory). Detailed system calibration information is provided with each CMG-5TD, including amplitude and phase 2 responses, the transducer output in Volts/meter/second , the transfer function in poles/zeros notation, and the digitizer sensitivity in counts per microvolt. The CMG-5TD has an internal flash memory with a capacity of up to 256 Mb. The digitiser program space is held in flash updateable memory allowing easy updating of the program either remotely or locally.
It is extremely simple to install the CMG5TD system, as no sensor levelling is required. The CMG-5TD output offsets can be reduced down to the sub millivolt range, they are adjusted electronically without exposing the insides of the accelerometer. The access to the offset adjustment is as simple as removing an 'O' ring sealed cap next to the sensor connector. It is possible to adjust the sensor offsets remotely when the optional remote centering is specified. The top cover of the CMG-5TD shows the sensor connectors, these being Analogue output, high and low gain outputs, RS-232 for Data, GPS port and Monitor Port. SIGNAL AND NOISE LEVELS The figure below contains a typical estimate of CMG-5TD transducer noise power plotted as (thick line) non-coherent power for the vertical and horizontal sensors. The USGS Low Noise Model, together with CMG-3T noise, is also plotted as a reference.
CMG-5TD - Page 2 of 8
The CMG-5TDB is available as a posthole or downhole package with the downhole version of the CMG-DM24. The CMG-5TDB sensor can be installed to depths of 100meters (other options are available). The CMG-5TDB is supplied with remote mass centering mechanism which ensures that the dc-coupled outputs of the accelerometer offset can be reduced to below the micovolt level. The mass centering mechanism is operated remotely from the CMG-DM24. SOFTWARE: SCREAM Guralp Systems Ltd SCREAM! software is a real-time packetised software application, which allows the user to acquire, configure, control, monitor and record data from all Guralp systems sensors and digitisers. SCREAM! is the perfect partner for GSL digitisers and digital output broadband sensors. Developed in parallel, they work as a team to provide an intuitive graphical interface to control the digitiser configuration, digitiser parameters and broadband seismometer commands. Sample rates, baud rates, triggering parameters, trigger band-pass filtering, storage and many other parameters are controllable using the mouse. Broadband sensor locking, unlocking and centering are achieved using point-and-click operations, which is particularly useful for borehole and cabled ocean bottom digital broadband seismometers, and duplex telemetered networks where the instrument is at a remote site. Sensor calibration, with adjustable amplitude and duration of the sinewave or squarewave signal can be initiated from the interactive display. It provides information about the complete broadband system in a convenient way. The data port of the digitiser allows the user to monitor the data without any loss to the data storage process. If the user has Matlab installed INSTANT sensor PSD, Self-Noise and coherence information can be calculated giving immense confidence regarding the status of the Instrument. Further details about this functionality are printed in the SCREAM datasheet.
CMG-5TD - Page 3 of 8
By simply typing in the instrument gains and digitiser scaling, the user can quickly plot the digitizers Power Spectral Density with ideal digitizer noise curves, Total Harmonic Distortion and Crosstalk between the two selected channels. It will also run system tests and plot the Coherence and PSD of both channels; or the self noise of either channel, in velocity or acceleration, referenced to ground motion, with the NLNM as a reference. The plot shows the power spectral density of Ground motion of data highlighted in SCREAM to give instant idea of quality of signal. TRIGGERING In it's standard configuration the digitiser outputs continuous data at a user-selectable sample rate. An additional powerful feature of the digitiser is the ability to simultaneously run a STA/LTA event triggering algorithm in parallel with the continuous acquisition. This permits the system to record continuously at a relatively low sample rate, and record at a much higher sample rate during short periods when triggered. Parameters controlling the triggering algorithm, and controlling the data output once the system is triggered, are all selectable by the user, permitting the maximum flexibility of operation and the most efficient use of available storage space. Shown below in the upper window, is an example of a data stream recording over a two month period. Two seismic events are shown highlighted in the two lower windows which, given suitable triggering parameters, can be recorded in greater detail at a higher sampling rate of upto 200 samples per second. (Upto 1000sps available please consult factory)
Triggering of all three components from vertical channel 100Hz tap, filter from 5 to 45 Hz Sta = 1, Lta = 50, Sta/Lta = 10, pre-trigger = 40, post-trigger = 70
CMG-5TD - Page 4 of 8
4g
2g
1g
0.5g
0.4g
0.2g
0.1g
>140dB >130dB dc to 100Hz (-3dB point) 50, 100 or 200 Hz 0.1% of full scale 0.001 g/g See plot on Page 3.
Calibration Controls Closed loop response: Calibration Signal Calibration signal is injected into the feedback network of the sensor Sine wave -0.001 Hz to 10 Hz (amplitude adjustable) Square wave or step response. (amplitude adjustable) The Calibration signal is injected through the CMGDM24. Standard instrument manual operation. Optional Remote DC null (as in borehole system).
Construction The CMG-5TD employs solid body technology along with surface mount and discrete electronics for Robust and reliable design.
CMG-5TD - Page 5 of 8
: : :
Anti-alias Filters Low Pass Filters Out of Band Rejection In band ripple Trigger Modes Digitizer Performance Standard Output Format Noise-free Resolution, NPR Absolute Accuracy Type Analogue Transducer Outputs Clock Oscillator Interface for External Receiver Sync for External Receiver Output Options RS232 RS422 Optical Short Haul modem
: : : : :
: : : : : : : : : : : :
CMG-5TD - Page 6 of 8
Physical Diameter Height Operating Temperature Range Pressure jacket material Weights: Triaxial:
: : :
168mm (6.6 in) 160mm (6.3 in) - 20C to + 65C Hard anodised aluminium 4.5Kg
Top Cap Connectors Digital Outputs and Power (RS232) GPS Input Power Customer Power Supply Current at 12 Vdc
: : : :
Optional CMG-5TD Baseplate The CMG-5TD can be provided optionally with a specially designed mounting plate. The mounting plate consists of two rings. One is securing fastened to the base of the instrument using the mount locations of the instruments feet. The second ring which includes a leveling device to give +/- 5 degrees of leveling is bolted using one central fixing hole to the ground. The instrument is then coupled to this plate via a series of screws.
CMG-5TD - Page 7 of 8
! ! ! ! ! ! ! ! ! ! ! ! ! !
110-240 V AC input Supplies Filtered UPS DC supply to Instrument RS-232 Modem Connection Support for Sync/async or leased line connections ISDN version available Full Modem LED status display Supports all key ITU data communication protocols Remote FLASH capability for software upgrade Upto 56K Kbps downloads with ITU V.90 or X2 ITU V.34 at 33.4 Kbps, V.32 at 19.2 Kbps Remote management capable 2 hour UPS standard, longer run times available Provides connectivity for compatible, reliable connections for all telephone networks Specifically designed for unattended remote operation.