Optimux-106 6.1 Ds
Optimux-106 6.1 Ds
Optimux-106 6.1 Ds
Optimux-106
Four-Channel T1 and Ethernet Multiplexer
Multiplexes four T1 channels and Ethernet link over a fiber optic link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber Automatic link backup with optional hot-swappable second main link Power redundancy with optional second wide-range power supply Management via ASCII terminal, dedicated Ethernet port, SNMP management station, or ConfiguRAD Web-based remote access terminal
The Optimux-106 multiplexer combines four T1 channels and an optional Ethernet link over a fiber optic uplink. A pair of Optimux units provides a simple and low-cost solution for connectivity over distances of up to 120 km (74.5 miles). For transmission reliability, an optional modular second link provides automatic backup upon link failure. An optional second power supply provides power redundancy for failsafe operation. Each of the four T1 signals of the tributary interface is transmitted independently, so that each T1 channel can be set to a different clock source.
Various optical uplink interfaces include: 850 nm VCSEL (Vertical Cavity Surface Emitting Laser) for multimode fiber 1310 nm LED for multimode fiber 1310/1550 nm laser diode or long-haul laser diode for extended range over single-mode fiber Single fiber (SF1, SF2 options), using a 1310 nm and 1550 nm laser diode transmitter with WDM technology, enables the laser to transmit the signal at a different wavelength than the receive signal
Single fiber (SF3 option) using SC/APC (Angled Polished Connector) technology, with a 1310 nm laser diode for single wavelength operation.
The basic model includes a fiber optic uplink and four tributary T1 links. Optimux-106 can be also ordered with an additional Ethernet user port, and with redundant uplink or power supply. Optimux-106 has comprehensive test and diagnostics capabilities that include local and remote loopbacks on the uplink interface and on each T1 tributary link. To facilitate system diagnostics, Optimux-106 features LED status indicators, AIS alarm generation and recognition, and dry contact closure upon link failure.
Optimux-106 can be configured and monitored locally via an ASCII terminal, or remotely via Telnet, Web-based remote access terminal (ConfiguRAD) or RADview-TDM running in a Windows or Unix environment.
The power supply is a wide-range AC/DC power supply that can be connected to either an AC power source (100 to 240 VAC), or to a DC power source (48 VDC). Optimux-106 is a compact standalone unit. A rack mount adapter kit enables installation of one or two (side-by-side) units in a 19-inch rack.
Data Sheet
Specifications
FIBER OPTIC UPLINK See Table 1 TRIBUTARY T1 CHANNELS Number of Channels 4 Data Rate 1544 kbps Line Code B8ZS Impedance 100, balanced Connectors RJ-45, balanced MNGETH and USER-ETH PORTS Type 10/100BaseT Connector Shielded RJ-45 USER-ETH Port Throughput 75 Mbps CONTROL PORT Type RS232 DCE asynchronous Data Rate 9.6, 19.2, 38.4, 57.6, 115.2 kbps Connector Mini-USB 5
ALARM PORT Type Dry relay contacts for major and minor alarms Connector RJ-45 GENERAL Standards G.703, G.824, G.955, IEEE 802.3 Diagnostics Local and remote loopbacks on uplink and on each T1 tributary link Timing Uplink: internal E1 tributary: transferred transparently, independent for each channel Front Panel Indicators PWR On (green): both power supplies OK On (red): power supply A fault On (yellow): power supply B fault Off: power supply fault LINK A/B On (red): Sync/Signal Loss on Link A/B (yellow): not used Off: normal operation CH1 to CH4 On (red): Signal Loss on channel On (yellow): AIS received on channel Off: normal operation
Rear Panel Indicators Sig Link A/B (on the fiber optic module) On (green): signal exists on Link A/B Off: no signal on Link A/B LINK/ACT On (yellow): link is up Off: link is down Blinks: frames are transmitted 100 On (green): 100 Mbps mode Off: 10 Mbps mode Power Wide range: 100 to 240 VAC or 48 VDC (40 to 72 VDC) Power Consumption AC: 25 VA max DC: 9W max Physical Height: 4.37 cm (1.7 in) Width: 21.7 cm (8.5 in) Depth: 17.0 cm (6.7 in) Weight: 0.5 kg (1.1 lb) Environment Temperature: 050C (32122F) Humidity: Up to 90%, non-condensing
[nm]
850 1310 1310 1550 1310 1550
[m]
62.5/125 multimode 9/125 single mode 62.5/125 multimode 9/125 single mode 9/125 single mode 9/125 single mode Laser (VCSEL) Laser LED Laser Laser (long haul) Laser (long haul) Laser WDM (SF1) Laser WDM (SF2) Laser (SF3)
[dBm]
-7 -12 -18 -12 -2 -2 -12 -12 -12
[dBm]
-34 -34 -32 -34 -34 -34 -34 -34 -27
[km]
6 47 7 76 72 120 47 47 20
[miles]
3.7 29.2 4.3 47.2 44.7 74.5 29.2 29.2 12.4 ST, SC, FC/PC ST, SC, FC/PC ST, SC ST, SC, FC/PC ST, SC, FC/PC ST, SC, FC/PC SC SC SC/APC
Tx: 1310 Rx 1550 9/125 single mode Tx: 1550 Rx 1310 9/125 single mode Tx/Rx: 1310 9/125 single mode
Note: The ranges specified above were calculated according to the following typical attenuation rates (with a 3 dB margin): 3.5 dB/km for 850 nm multimode 0.4 dB/km for 1310 nm single mode 0.25 dB/km for 1550 nm single mode
Data Sheet
Optimux-106 Four-Channel T1 and Ethernet Multiplexer
Ordering
OP-106/%/!/#/+/*
Legend
% Optional power supply: R Second redundant power supply (default is one power supply only) Optional user port: ETH 10/100BaseT User Ethernet port Main link interface connector type: ST ST type connector FC FC/PC type connector SC SC type connector
Note: ST and FC connectors are not available for the single fiber options.
Uplink interface connector type: 85L 850 nm, multimode, VCSEL 13 1310 nm, multimode, LED
Note: Available with ST and SC connectors only
325-100-01/08 Specifications are subject to change without prior notice. 19972008 RAD Data Communications Ltd. All other trademarks are the property of their respective holders.
13L
1310 nm, single mode, laser diode 15L 1550 nm, single mode, laser diode 13LH 1310 nm, single mode, long-haul laser diode 15LH 1550 nm, single mode, long-haul laser diode SF1 Transmit 1310 nm laser (WDM), receive 1550 nm SF2 Transmit 1550 nm laser (WDM), receive 1310 nm SF3 Transmit and receive at 1310 m laser diode Optional link module: D Second redundant uplink module (of same type as first uplink module). Default is a single uplink module
Note: For single fiber applications, a device with SF1 interface is always used opposite a device with SF2 interface, and vice versa. An SF3 interface works only opposite another SF3 interface.
SUPPLIED ACCESSORIES AC power cord DC adapter plug CBL-MUSB-DB9F Control port cable CBL-RJ45-DB9/F Alarm port cable OPTIONAL ACCESSORIES RM-33-2 Kit for mounting 1 or 2 units in a 19-inch rack
International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail market@rad.com
North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail market@radusa.com
www.rad.com