Circuit and Outlet Conversion Information ..............340 V10 Series ......................................................341 - 345 V12 Series ......................................................347 - 350 V20 Series ......................................................351 - 372 25P Series ......................................................373 - 378 V42 Series ......................................................379 - 384 V50 Series ......................................................385 - 388 SP, SPK, & SSK Series ....................................389 - 391 300 & 400 Series ............................................392 - 393 Solenoid Operated Directional Valves......................394 Directional Control Valves (4-Way)..................395 - 396 Float Position Valves ................................................397 Selector Valves ................................................398 - 400 Directional Control Valves ..............................401 - 402 Unidirectional Valves ................................................403 Check Valves ..................................................404 - 405 Lock Valves ....................................................406 - 409 Flow Dividers ..................................................410 - 417 Flow Control Valves ........................................418 - 419 Cushion Valves ................................................420 - 422 Relief Valves ....................................................423 - 430 Repair Parts & Seal Kits ..................................543 - 552
GRESEN VALVES
Valves
PARALLEL HYDRAULIC CIRCUITS
The most common type of hydraulic circuit is the parallel circuit. Refer to the parallel circuit diagram. With all valve spools centered, the pump flow will return to tank at low pressure through the open center bypass. When a spool is actuated, the open center bypass is blocked and the inlet is connected to one of the work ports. The opposite work port will be connected to tank, completing the circuit. If more than one valve spool is shifted at the same time, the oil will follow the path of least resistance and the hydraulic cylinder or motor having the lightest load will begin to function first. If the spool of the cylinder or motor having the lightest load is metered (not fully shifted), then both may be operated at the same time.
340
GRESEN - V10
Series V10
V10
Directional Control Valves
Parallel and Tandem work sections with individual load (reverse flow) checks Available for open center, closed center and power beyond applications Low flow and high flow spool options available offering flows to 15 GPM (45 lpm). Continuous system operating pressures to 3500 PSI (Work port pressures to 5000 PSI) Utilizes many common components such as relief valves, spool positioners and handles with Models V11 and V16 3-Way, 4-Way, and 4-Way Float operation Numerous manual spool positioner options plus remote hydraulic or electric solenoid operation Work Port relief valves and anti-cavitation check valves available Single handle or dual function mechanical joystick control of manual sections Enclosed spool ends with handles Long life - low friction spool seals Gresens Model V10 sectional directional control valves provide parallel or tandem circuit operation for open center and closed center systems. They offer economy and excellent performance in a compact design.
Specifications . . . . . . . . . . . . . . . . . . .15 GPM (56,7 liters/min)
Operating Pressure (maximum) Continuous Operating . . . . . . . . . . . . . . . . . . . . . .3500 PSI (242 bar) Work Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5000 PSI (345 bar) Exhaust Core . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500 PSI (34,5 bar) Operating Temperature . . . . . . . . . . . .-40F (-40C) to +200F (+93C) Standard Port Sizes 2 Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SAE 10 Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SAE 10 Power Beyond . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SAE 10 Work Ports (Manual and Solenoid Work Sections) . . . . . . . . . . .SAE 8 Fluid Compatibility Petroleum Based . . . . . . . . . . . . . . . . . . . .60-1000 SSU (10-216 cST) O-Ring Seals . . . . . . . . . . . . . . . . . . . .Buna-N Standard (Optional Viton) Spool Seals . . . . . . . . . . . . . . . .Lip Type (Standard in 24990 Housings) O-Rings (Standard in 23592 Housings) Filtration Required . . . . . . . . . . . . . . . . . . . . .10 micrometers (nominal) Number of Work Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9 Weight (approx.) No. 23613 Inlet Cover . . . . . . . . . . . . . . . . . . .Approx. 5 lbs. (2,3 kg) No. 23627 Outlet Cover . . . . . . . . . . . . . . . . . .Approx. 5 lbs. (2,3 kg) No. 24990 Work Section (Manual) . . . . . . . . . .Approx. 6 lbs. (2,8 kg) No. 23962 Work Section (Solenoid) . . . . . . . .Approx. 8.5 lbs. (3,8 kg) Mounting Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Not Restricted
GRESEN - V10
Series V10
V10 INLET COVERS (Housing No. 23613)
Item No.
Model Number
Part Number
End Inlet
End Outlet
Top Inlet
Top Outlet
SAE 10
SAE 8
List Price
1 2 3
23613 Left Cover
1
All inlet covers machined to accept main relief cartridges. Two SAE port plugs are furnished loose with Items 1 and 2. Used for Solenoid Valve Assemblies. Only top ports are available with this cover.
Model Number
Part Number
Pressure Range and Setting 1750-1999 2000-2599 2600-3000 3001-3500 Externally Set @ 1950 Set @ 2550 Set @ 3000 Set @ 3500 Adjustable PSI c/p PSI c/p PSI c/p PSI c/p PSI c/p
List Price
1
No Relief Cavity Plug
2 3 4 5 6 7
Model Number
Part Number
Description
List Price
1
External Adjustment Kit
K-WH-A
8650381
15.60
Model Number
Part Number
SAE 8
SAE 10
Top Outlet
End Outlet
List Price
1 2
23627 Outlet Cover
1
10-RC-8-EY 10-RC-10-EY
13650719 13650720
10-RC-10-P-MECH 26157002
All outlet covers machined to accept (top) Option Cartridges. Two SAE port plugs furnished loose with each cover. Used for Solenoid Valve Assemblies. The pressure control cartridge must be located in the downstream valve if using the optional power beyond feature in the solenoid-operated upstream valve.
Model Number
Part Number
Description
List Price
1 2 3
Closed Center Plug
Closed Center Plug SAE 8 Power Beyond Sleeve SAE 10 Power Beyond Sleeve Pilot Control Cartridge (for Solenoid Valves)
The power beyond sleeves listed here are required for (top) power beyond port only. To power beyond out the (end) of the valve, requires installation of the K-10-C plug in the (top) option port. Refer to the V10 Service Manual for procedures on selecting Closed Center and Power Beyond options.
342
GRESEN - V10
Series V10
V10 Parallel Work Sections with Machined Upper Option Cavities (Housing No. 24990)
3-Way 3-Pos [3] 4-Way 3-Pos [4] 4-Way 3 -Pos Free Flow [F4] 4-Way 4-Pos Float [K4] Spring Return to Neutral [0] 3-Pos Detent [D] 1-Pos. Detent (Spool In) [R]
Item No.
Model Number
Part Number
SAE 8 [8]
List Price
1 2 3 4 5 6
The work sections listed above all have the upper work port relief option cavities machined and plugged. V10 work sections do not include handles or brackets. They are supplied (LCHA) Less Complete Handle Assembly.
V10 Parallel Work Sections Without Upper Option Cavities (Housing No. 24990)
3-Way 3-Pos [3] 4-Way 3-Pos [4] 4-Way 3 -Pos Free Flow [F4] 4-Way 4-Pos Float [K4] Spring Return to Neutral [0] 3-Pos Detent [D] 1-Pos. Detent (Spool In) [R]
Item No.
Model Number
Part Number
SAE 8 [8]
List Price
1 2 3 4 5 6
The N in the work sections listed above designates that the upper work port relief option cavities are NOT machined. If the application requires the use of work port option cartridges, (i.e. reliefs or anti-cavitation checks), do not select work section from this group. V10 work sections do not include handles or brackets. They are supplied (LCHA) Less Complete Handle Assembly.
V10 Tandem Work Sections with Machined Upper Option Cavities (Housing No. 24990)
3-Way 3-Pos [3] 4-Way 3-Pos [4] 4-Way 3 -Pos Free Flow [F4] 4-Way 4-Pos Float [K4] Spring Return to Neutral [0] 3-Pos Detent [D] 1-Pos. Detent (Spool In) [R]
Item No.
Model Number
Part Number
SAE 8 [8]
List Price
1 2 3 4 5 6
The work sections listed above all have the upper work port relief option cavities machined and plugged. V10 work sections do not include handles or brackets. They are supplied (LCHA) Less Complete Handle Assembly.
V10 Tandem Work Sections Without Upper Option Cavities (Housing No. 24990)
3-Way 3-Pos [3] 4-Way 3-Pos [4] 4-Way 3 -Pos Free Flow [F4] 4-Way 4-Pos Float [K4] Spring Return to Neutral [0] 3-Pos Detent [D] 1-Pos. Detent (Spool In) [R]
Item No.
Model Number
Part Number
SAE 8 [8]
List Price
1 2 3 4 5 6
The N in the work sections listed above designates that the upper work port relief option cavities are NOT machined. If the application requires the use of work port option cartridges, (i.e. reliefs or anti-cavitation checks), do not select work section from this group. V10 work sections do not include handles or brackets. They are supplied (LCHA) Less Complete Handle Assembly.
343
GRESEN - V10
Series V10
V10 Parallel Solenoid-Operated Work Sections with Machined Upper Option Cavities (Housing No. 23962)
3-Way 3-Pos [3] 4-Way 3-Pos [4] 4-Way 3 -Pos Free Flow [F4] 12 VDC On/Off Solenoid [SOL-I-12] 12 VDC Proportional Solenoid [EPC-I-12]
Item No.
Model Number
Part Number
SAE 8 [8]
List Price
1 2 3 4 5 6
The solenoid-operated work sections listed above all have the upper work port relief option cavities machined and plugged. These sections do NOT offer the handle override feature. Contact the Gresen factory in Minneapolis for solenoid sections with handle.
Model Number
Part Number
Description
List Price
1 2 3
Positioner Kit
K-10-A K-V10-A K-10-D K-V10-D K-10-M K-V10-M K-10-S K-V10-S K-10-RI K-V10-RI K-10-RO K-V10-RO
13650746 26157056 13650747 26157057 13650748 26157058 13650749 26157059 13650750 26157060 13650751 26157061
Spring Extended Spool Positioner 1 Spring Extended Spool Positioner (For Use With 24990 Housing) 1 3-Position, D Detent Spool Positioner 3-Position, D Detent Spool Positioner (For Use With 24990 Housing) Manual M Spool Positioner Manual M Spool Positioner (For Use With 24990 Housing) Spring Center to Neutral Spool Positioner Spring Return to Neutral Spool Positioner (For Use With 24990 Housing) 1-Position, R Detent Spool IN with Spring return to Neutral 1-Position, R Detent Spool IN with Spring return to Neutral 1-Position, R Detent Spool OUT with Spring return to Neutral
2
24.20 24.20 29.10 29.10 23.10 23.10 26.00 26.00 47.60 47.60 48.40 48.40
4 5 6 7 8 9 10 11 12
1-Position, R Detent Spool OUT with Spring return to Neutral (For Use with 24990 Housing) 2
The Above K-V10-(Kits) are for use with the new style 24990 work section housings. The internal working parts are NOT interchangeable with the equivalent K-10-(Kits).
1
K-10-A and K-V10-A Spool Positioners holds the spool in the B port power (Spool Out) position and will limit the shifting of the spool to the neutral position only. K-10-RO and K-V10-RO Spool Positioner detent sleeve may be reversed for RIO (Detent In and Out) applications. Refer to the V10 Service and Parts manual for procedures.
Model Number
Part Number
Description
List Price
1 2 3 4
1
V10 Mechanical Joystick, LH Assembly V10 Mechanical Joystick, RH Assembly Mechanical Joystick Offset Handle Assembly Mechanical Joystick Straight Handle Assembly
344
GRESEN - V10
Series V10
Handle Option Kits
Item No.
Model Number
Part Number
Description
List Price
1 2 3 4 5 6
26157100 13650752 13650753 13650786 13650948 26157101 Vertical Handle Assembly Horizontal Handle Assembly Extended Vertical Handle Kit - For use in V10/V11 valves using port reliefs on handle end Extended Horizontal Handle Kit - For use in V10/V11 valves using port reliefs on handle end
46.40 5.20
Refer to Model V10 Service Catalog No. GSD-1010 for information regarding handle installation.
Horizontal Handle Assembly List Price
Model Number
Part Number
Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 K-10-1 K-10-2 K-10-3 K-10-4 K-10-5 K-10-6 K-10-7 K-10-8 K-10-9 K-10-10 K-10-11 K-10-SECT-SEAL K-10-SOL-SEAL 13650755 13650756 13650757 13650758 13650759 13650760 13650761 13650762 13650763 13650764 13650765 13650767 26157030
Spacer for Older Handles Stud Kit for One (1) Work Section Stud Kit for Two (2) Work Sections Stud Kit for Three (3) Work Sections Stud Kit for Four (4) Work Sections Stud Kit for Five (5) Work Sections Stud Kit for Six (6) Work Sections Stud Kit for Seven (7) Work Sections Stud Kit for Eight (8) Work Sections Stud Kit for Nine (9) Work Sections Stud Kit for Ten (10) Work Sections Stud Kit for Eleven (11) Work Sections Section Seal Kit (Tall) Mounting Bracket - For use with V10 Solenoid Valve Assemblies Section Seal for Solenoid Pilot Passage (25 pieces of 21866001 Seal).
6.50 26.70 26.70 26.70 26.70 26.70 29.60 29.60 29.60 29.60 29.60 29.60 3.30 23.70 29.50
Assembly Stud Kit
K-10-SOL-BRACKET 26157088
Each Stud Kit includes (4) Studs, (8) Nuts, (2) Mounting Brackets and the required number of Section Seals.
Model Number
Part Number
Anti-Cav Check
Relief Valve
List Price
1 2 3 4 5
Model RP10A (-AC) relief cartridges are externally adjustable. Model RP10N (-AC) relief cartridges are preset at specified setting and offer a tamper resistant cover.
Model Number
Part Number
Description
List Price
K-10-NR-WP
13650773
Work Port Relief Cavity NRPlug (Not for use in V10 Inlet Covers)
10.80
345
ntertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen Cylinders, Pumps, Motors & Valves / Commercial ntertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen Cylinders, Pumps, Motors & Valves / Commercial ntertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories / Cylinders / Prince Cylinders & Pumps / Chief Cylinders / Perfection Pumps / White Motors / Gresen Cylinders, Pumps, Motors & Valves / Commercial Intertech Cylinders, Pumps & Motors / Custom Hoists / LHA Accessories Cylinders / Prince Cylinders & Pumps / Chief Cylinders /
GRESEN - V12
Series V12
V12
Specifications
Pressure Rating: Continuous Operating, Max. . . . . . . . . . . .3000 PSI (207 bar) Tank Port (Exhaust), Max. . . . . . . . . . . . . .500 PSI (34,5 bar) Capacity: Nominal Flow . . . . . . . . . . . . . . . . . .12 GPM (45,4 litres/min) Operating Temperature: . . . . . . . .-40F (-40C) to 176F (80C) Port Size: Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SAE 10 Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SAE 10 Work Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SAE 8 Power Beyond . . . . . . . . . . . . . . . . . . . . . . . . .SAE 8, SAE 10 Filtration Required (Min.) . . . . . . . . . . . . . . . . .33 micrometre Weight: Inlet Cover . . . . . . . . . . . . . . . . . . . .Approx. 3.3 lbs. (1,5 kg) Outlet Cover . . . . . . . . . . . . . . . . . . .Approx. 3.3 lbs. (1,5 kg) Work Sections: Standard . . . . . . . . . . . . . . . . . . . . .Approx. 5 lbs. (2,3 kg) Accessory . . . . . . . . . . . . . . . . . . .Approx. 6.5 lbs. (2,7 kg)
GRESEN - V12
Series V12
LEFT COVER
Order Code Bill of Material # SAE 10 Port Size [2] SAE 8 Port Size [1] Top & End Inlet [U] Plastic Relief Cavity Plug [N] Relief Position "B" [B]
8650-584 8650-974
Note: All Left Covers are machined to accept Main Relief Cartridge.
RCP-15A CRV-15B-2500
Model CRV-15B Pilot Operated Relief Valve Cartridge
No Relief Plug Kit (NR Option) Pilot Operated Relief Valve Cartridge set at 2500 PSI. Crack at 1 GPM Direct Acting Relief Valve Cartridge set at 2500 PSI. Crack at 1 GPM
CRV-15F-2500
Above Relief Valves are screw adjustable from 500 to 3000 PSI.
RIGHT COVER
Order Code Bill of Material # SAE 10 Port Size [2] SAE 8 Port Size [1] Top & End Outlet [U] Machined from Opened Center [O]
V12E-2UO V12E-1UO
V12E Right Cover
8650-587 8650-972
Open Center port may be converted to Closed Center or Power Beyond using Option Kits below.
Closed Center Plug SAE 8 Power Beyond Sleeve SAE 10 Power Beyond Sleeve
348
GRESEN - V12
Series V12
WORK SECTIONS
Item No.
Order Code
Bill of Material #
1 2 3 4 5 6 7 8
Note: All work ports are SAE 8. All spools include female spool end located on B port end - Handle bracket and handle assembly not included. *All relief option sections [R] include machined and plugged (plastic plugs) work port options [NN]. **All lockout option sections [L] include cylinder lock valves [EE]. Float Section(s) must be stacked next to the Inlet Cover to allow proper operation.
LVR-15-HDA
8650-598
Vertical Handle
349
GRESEN - V12
Series V12
Section Stud Assembly Kits
Includes Section Seals and Nuts.
Order Code Bill of Material # Number of Work Stations
One Section Two Section Three Section Four Section Five Section Six Section Seven Section Eight Section
K-12-D
Spool Action Assembly (Bonnet)
8650-607
3-Position Detent
Direct Acting Relief Pilot Operated Relief Combination Relief & Anti-Cav Anti-Cavitation Check No Relief Plug Kit (NR Option for R Body) Lock Cavity Plug (for L Body)
Note: All above Relief Valves are screw adjustable. Crack Pressure set at 1 GPM.
350
GRESEN - V20
Series V20
V20
Minimal spool actuating effort - Maximum, 50 pounds [22,6 kg] at the spool Improved, extra-fine metering Minimum pressure drops through open center and through work ports Float section may be installed at any point within the valve assembly
Hydraulic oil is directed from the inlet port, through the open center core to the outlet port of the Directional Control Valve when all spools are in the neutral position. Shifting the valve spool directs oil flow to the desired work port. Maximum circuit pressure is limited by the main relief valve, which relieves into the exhaust core. In a neutral position, open center systems operate at full flow and at low pressure
The Model V20C work section has no open center core. Pump flow is blocked by the valve when the valve spool is in neutral position. Shifting the valve spool directs the oil flow to the desired work port. A pump that varies the output flow and maintains a pre-determined output pressure is required for this type of circuit. Closed center systems typically operate at minimum flow and at high pressure standby when the valve spool is in the neutral position. The only flow required is that which will compensate for internal losses or for other system requirements.
351
GRESEN - V20
Series V20
V20 LEFT COVERS (Housing No.'s 8398 & 7736)
Order Code Bill of Material # End Inlet Top Inlet End Outlet Top Outlet Port Size SAE 12 [12] Port Size 3/4" NPT [75] With 4-25 GPM Flow Control To Allow Use of Excess Flow [FC]
Note: All the above inlet covers are machined to accept the main relief cartridges listed below. Two port plugs are furnished loose with each cover, one is machined for 1/4" NPTF gauge port. Excess flow plug is furnished with all 7736 housings.
Note: All above Relief Valves have stainless steel springs. WH Relief Valves are internal shim adjustable. RP51A Relief Valves are external screw adjustable.
K-WH-A
8650-381
352
GRESEN - V20
Series V20
V20 RIGHT COVERS (Housing No.s 6770 & 8644)
Outlet Port Size & Location Order Code Bill of Material # 3/4" NPT [75] SAE 10 [10] SAE 12 [12] Top Power Beyond Port [MY] (8644 Housing Only) Machined for Power Beyond [MY] Includes Load Sense Option Includes Bleed-off [LS] Includes 12VDC On-off Pressure Control Cartridge [PC] 24VDC On-off Pressure Control Cartridge [PC] SAE 4 Load Sense Port & Pilot Seal Cbores [P-NB]
20-RC-75-E 20-RC-75-E-MY 20-RC-10-E 20-RC-12-E 20-RC-12-E-MY 20-RC-12-E-LS 20-RC-12-E-PC-SOL-12 20-RC-12-E-PC-SOL-24 20-RC-75-ET-75-MY 20-RC-12-ET-12-MY 20-RC-12-E-LS-P-NB (NB = No bleed off)
13650-147 8650-027 13650-145 13650-146 8650-024 8650-025 8650-026 13650-307 8650-023 8650-022
END END END END END END END END END & TOP END & TOP END 3/4" NPT SAE 12
13650-169
NOTE: A 3/4" NPT or SAE 12 Plug will be shipped with all 8644 Outlet Covers to plug either the outlet port or power beyond port if either is not required. Plugging top power beyond port will convert valve to closed center unless internal plug is removed. This cover must be used in the downstream valve if a power beyond sleeve is used in the utility section of a solenoid upstream valve. No Bleed Off (NB) cannot be converted to Bleed Off. Bleed Off Covers, however, may be converted to No Bleed Off.
Closed Center Plug Conversion Plug 1/2" NPT Power Beyond Sleeve SAE 8 Power Beyond Sleeve SAE 10 Power Beyond Sleeve
NOTE: These option kits may not be used with 6770 LS (Load Sense) or 8644 covers.
353
GRESEN - V20
Series V20
V20 PARALLEL WORK SECTIONS (Housing No. 8072)
Bracket Assembly included. Includes load checks where applicable.
4-Way 3-Pos. Free Flow Spool [F] 4-Way 4-Pos. Float Assembly [K4] 1/2" NPT Work Ports [50] SAE 8 Work Ports [08] SAE 10 Spring Return Work to Ports Neutral [10] Internal Hydraulic Detent Release Set @ 2000 PSI [KO] 12VDC Solenoid (External Pilot Design) [SOL-E] Hydraulic Remote Spool Actuator [HRO] Rotary Spool Actuator [W] Stainless Steel Spool [SS] 24 VDC Solenoid (External Pilot Design) [SOL-E]
Item No.
Order Code
Bill of Material #
1 20-50-04 2 20-08-04 3 20-10-04 4 20-50-F4 5 20-08-F4 6 20-10-F4 7 20-50-03 8 20-08-03 9 20-10-03 10 20-50-K4 11 20-08-K4 12 20-10-K4 13 20-10-04-SOL-E-12 14 20-10-04-SOL-E-24 15 20-10-03-SOL-E-12 16 20-10-03-SOL-E-24 17 20-10-04-HRO* 18 20-10-KO4-2000 19 20-10-W4* 20 20-10-DF4 21 20-10-W4-SS* 22 20-10-WF4-SS* 23 20-10-F4-SOL-E-24 24 20-10-F4-SOL-E-12 25 20-08-DF4
8650-021 13650-148 8650-020 8650-019 13650-151 8650-018 8650-017 13650-149 8650-016 8650-015 13650-150 8650-014 8650-013 13650-279 13650-280 13650-278 8650-578 8650-011 8650-010 8650-009 8650-638 8650-639 13650-530 13650-529 13650-838
*Bracket Assembly not furnished with Rotary Spool Option (W) Items 19, 21 & 22 or Hydraulic Remote Spool Actuator (HRO) Item 17.
Model V20P
354
GRESEN - V20
Series V20
V20RP PARALLEL WORK SECTIONS (Housing No. 10954)
Bracket assembly included. Includes load checks where applicable.
Reduced Pressure Drop Section [RP] 4-Way 4-Way 4-Way 3-Position 4-Position Spring 3-Position Detent Free Return to Float Free Flow Flow Neutral [K] [F4] [DF] Internal Pilot ThruPassage [PILOT]
Item No.
Order Code
Bill of Material #
1 20R-10-R3 2 20R-10-03 3 20R-12-03 4 20R-12-R3 5 20R-10-04 6 20R-12-04 7 20R-10-F4 8 20R-12-F4 9 20R-10-DF4 10 20R-10-K4
13650-855 13650-856 13650-857 13650-858 8650-613 13650-859 13650-276 13650-860 13650-861 13650-862
11 20R-10-04-PILOT 13650-863
NOTE: The "Pilot" code designates that the internal pilot through-passages have been machined for use when intermixing solenoid and manual sections.
V20T and V20RT TANDEM WORK SECTIONS (Housing No.s 8112 & 10762)
Item No.
Order Code
Bill of Material #
Model V20T (8112 Section)
NOTE: V20T and V20RT (Tandem) sections may be stacked with V20 (Parallel) sections. Refer to V20T product literature for stacking sequence restrictions.
Order Code
Bill of Material #
1 2 3
Model V20S (11483 Section)
NOTE: V20S (Series) sections may be stacked with V20P (Parallel) and V20 T (Tandem) sections. Refer to V20S product literature for stacking sequence restrictions.
355
GRESEN - V20
Series V20
V20LO LOCKOUT WORK SECTIONS (Housing No. 11571)
Item No.
Order Code
Bill of Material #
1
Model V20LO (11571 Section)
20-10-L03 20-10-LO4
13650-864 8650-007
NOTE: V20S (Series) sections may be stacked with V20P (Parallel) and V20T (Tandem) sections. Refer to V20S product literature for stacking sequence restrictions.
Order Code
Bill of Material #
4-Way 4-Way 4-Way 3-Position 4-Way 3-Way Spring 3-Position Detent Free 4-Position R-Type Detented Float 3-Position 3-Position Return to Free Flow Flow [F4] [4] [4] [K] [3] Neutral [DF4]
1 20C-10-R3
Model V20C (8364 Section)
NOTE: The Pilot code designates that the internal pilot through-passages have been machined for use when intermixing solenoid and manual sections.
Order Code
Bill of Material #
4-Way 4-Way 3-Pos Spring 3-Pos Detent Return to Free Flow Free Flow Neutral [F4] [DF4]
O-Ring Internal Pilot "R" Type Cbores Only ThruDetent Machined Passage [R] [CBORES} [PILOT]
13650-844 13650-575 13650-572 13650-954 8650-005 13650-576 13650-277 13650-845 13650-846 13650-847 13650-848 13650-849
NOTES: The Cbore code designates that the pilot seal counterbores have been machined into the upstream side of the work section. This section must be used as the first manual section in V20 valve assemblies using an upstream Unloading Utility Section when having V20LS solenoid and manual sections downstream. The Pilot code designates that the internal pilot through-passages have been machined for use when intermixing solenoid and manual sections.
356
GRESEN - V20
Series V20
V20PC PRESSURE COMPENSATED WORK SECTIONS (Housing No. 8364)
(Manually-Operated) Load Checks not available with V20PC Work Sections.
Closed Center/ Load Sensing [LS]* SAE 10 Work Ports [10] Maximum Flow Rate (GPM) [05] [10] [15]
Item No.
Order Code
Bill of Material #
1 2 3 4 5 6 7 8 9
* Load sensing sections may be used for closed center or load sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover.
Item No.
Order Code
Bill of Material #
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
20PC-LS-10-04-05-EPC-I-12 20PC-LS-10-04-10-EPC-I-12 20PC-LS-10-04-15-EPC-I-12 20PC-LS-10-03-05-EPC-I-12 20PC-LS-10-03-10-EPC-I-12 20PC-LS-10-03-15-EPC-I-12 20PC-LS-10-F4-05-EPC-I-12 20PC-LS-10-F4-10-EPC-I-12 20PC-LS-10-F4-15-EPC-I-12 20PC-LS-10-02-05-EPC-I-12 20PC-LS-10-02-10-EPC-I-12 20PC-LS-10-02-15-EPC-I-12 20PC-LS-12-02-15-EPC-I-12 20PC-LS-10-F2-05-EPC-I-12 20PC-LS-10-F2-10-EPC-I-12 20PC-LS-10-F2-15-EPC-I-12
13650-010 13650-011 13650-012 13650-013 13650-014 13650-015 13650-016 13650-017 13650-018 13650-058 13650-059 13650-060 13650-865 13650-866 13650-867 13650-868
* Load sensing sections may be used for closed center or load sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover. ** Because of the internal pilot porting, EPC sections must be stacked directly upstream from the utility section.
357
GRESEN - V20
Series V20
V20PC PRESSURE COMPENSATED WORK SECTIONS (Housing No. 8364), Continued
Solenoid-Operated (ProportionalEPC) Load Checks not available with V20PC Work Sections.
Closed 4-Way 2-Way SAE 10 SAE 12 Maximum Flow SAE 10 Center/ 4-Way 3-Way 3-Pos. 2-Way 2-Pos. Work Work Rate Ports Load 3-Pos. 3-Pos. Free 2-Pos. Free Ports Ports (GPM) [10] [03] [2] Sensing [04] Flow Flow [12] [10] [LS]* [F4] [F2] [05] [10] [15] 12 VDC EPC Actuator [EPC-I] 24VDC EPC Actuator [EPC-I]
Item No.
Order Code
Bill of Material #
17 18 19 20 21 22 23 24 25 26 27 28 29
20PC-LS-12-F2-15-EPC-I-12 20PC-LS-10-02-05-EPC-I-24 20PC-LS-10-02-10-EPC-I-24 20PC-LS-10-02-15-EPC-I-24 20PC-LS-10-04-05-EPC-I-24 20PC-LS-10-04-10-EPC-I-24 20PC-LS-10-04-15-EPC-I-24 20PC-LS-10-03-05-EPC-I-24 20PC-LS-10-03-10-EPC-I-24 20PC-LS-10-03-15-EPC-I-24 20PC-LS-10-F4-05-EPC-I-24 20PC-LS-10-F4-10-EPC-I-24 20PC-LS-10-F4-15-EPC-I-24
13650-869 13650-195 13650-196 13650-197 13650-198 13650-199 13650-200 13650-201 13650-202 13650-203 13650-204 13650-205 13650-206
* Load sensing sections may be used for closed center or load sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover. ** Because of the internal pilot porting, EPC sections must be stacked directly upstream from the utility section.
Item No.
Order Code
Bill of Material #
1 2 3 4 5 6 7 8 9 10 11
20PC-LS-10-04-05-SOL-I-24 20PC-LS-10-04-10-SOL-I-24 20PC-LS-10-04-15-SOL-I-24 20PC-LS-10-03-05-SOL-I-24 20PC-LS-10-03-10-SOL-I-24 20PC-LS-10-03-15-SOL-I-24 20PC-LS-10-F4-05-SOL-I-24 20PC-LS-10-F4-10-SOL-I-24 20PC-LS-10-F4-15-SOL-I-24 20PC-LS-10-04-05-SOL-I-12 20PC-LS-10-04-10-SOL-I-12
13650-207 13650-208 13650-209 13650-210 13650-211 13650-212 13650-213 13650-214 13650-215 13650-061 13650-062
* Load sensing sections may be used for closed center or load sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover. ** Because of the internal pilot porting, SOL sections must be stacked directly upstream from the utility section.
358
GRESEN - V20
Series V20
V20PC PRESSURE COMPENSATED WORK SECTIONS (Housing No. 8364), Continued
Solenoid-Operated (On/OffSol) Load Checks not available with V20 PC Work Sections.
Closed Center/ Load Sensing [LS]* SAE 10 Work Ports [10] Maximum Flow Rate (GPM) [05] [10] [15] 12 VDC On/off SOL [SOL-I] 24 VDC On/off SOL [SOL-I]
Item No.
Order Code
Bill of Material #
12 13 14 15 16 17 18
* Load sensing sections may be used for closed center or load sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover. ** Because of the internal pilot porting, SOL sections must be stacked directly upstream from the utility section.
Item No.
Order Code
Bill of Material #
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
20PC-LS-10-04-05-EPC-IH-12 20PC-LS-10-04-10-EPC-IH-12 20PC-LS-10-04-15-EPC-IH-12 20PC-LS-10-03-05-EPC-IH-12 20PC-LS-10-03-10-EPC-IH-12 20PC-LS-10-03-15-EPC-IH-12 20PC-LS-10-F4-05-EPC-IH-12 20PC-LS-10-F4-10-EPC-IH-12 20PC-LS-10-F4-15-EPC-IH-12 20PC-LS-10-04-05-EPC-IH-24 20PC-LS-10-04-10-EPC-IH-24 20PC-LS-10-04-15-EPC-IH-24 20PC-LS-10-03-05-EPC-IH-24 20PC-LS-10-03-10-EPC-IH-24 20PC-LS-10-03-15-EPC-IH-24 20PC-LS-10-F4-05-EPC-IH-24
13650-225 13650-226 13650-227 13650-228 13650-229 13650-230 13650-231 13650-232 13650-233 13650-252 13650-253 13650-254 13650-255 13650-256 13650-257 13650-258
* Load sensing sections may be used for closed center or load sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover. ** Because of the internal pilot porting, EPC sections must be stacked directly upstream from the utility section.
359
GRESEN - V20
Series V20
V20PC PRESSURE COMPENSATED WORK SECTIONS (Housing No. 8364), Continued
Solenoid-Operated (EPC Proportional With Handle) Load Checks not available with V20 PC Work Sections.
Closed Center/ Load Sensing [LS]* SAE 10 Work Ports [10] Maximum Flow Rate (GPM) [05] [10] [15] 12 VDC 24 VDC EPC EPC with with Handle Handle [EPC-IH-12] [EPC-IH-24]
Item No.
Order Code
Bill of Material #
17 18
20PC-LS-10-F4-10-EPC-IH-24 20PC-LS-10-F4-15-EPC-IH-24
13650-259 13650-260
* Load sensing sections may be used for closed center or load sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover. ** Because of the internal pilot porting, EPC sections must be stacked directly upstream from the utility section.
Item No.
Order Code
Bill of Material #
1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19
20PC-LS-10-04-05-SOL-IH-12 20PC-LS-10-04-10-SOL-IH-12 20PC-LS-10-04-15-SOL-IH-12 20PC-LS-10-03-05-SOL-IH-12 20PC-LS-10-03-10-SOL-IH-12 20PC-LS-10-03-15-SOL-IH-12 20PC-LS-10-F4-05-SOL-IH-12 20PC-LS-10-F4-10-SOL-IH-12 20PC-LS-10-F4-15-SOL-IH-12 20PC-LS-10-04-05-SOL-IH-24 20PC-LS-10-04-10-SOL-IH-24 20PC-LS-10-04-15-SOL-IH-24 20PC-LS-10-03-05-SOL-IH-24 20PC-LS-10-03-10-SOL-IH-24 20PC-LS-10-03-15-SOL-IH-24 20PC-LS-10-F4-05-SOL-IH-24 20PC-LS-10-F4-10-SOL-IH-24 20PC-LS-10-F4-15-SOL-IH-24
13650-234 13650-235 13650-236 13650-237 13650-238 13650-239 13650-240 13650-241 13650-242 13650-261 13650-262 13650-263 13650-264 13650-265 13650-266 13650-267 13650-268 13650-269
* Load sensing sections may be used for closed center or load sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover. ** Because of the internal pilot porting, SOL sections must be stacked directly upstream from the utility section.
360
GRESEN - V20
Series V20
V20RP PARALLEL SOLENOID WORK SECTIONS (Housing No. 10954)
Solenoid-Operated (On/OffSOL) (V20-SOL-I internal pilot porting design).
Bill of Material # Closed Center/ 4-Way 3-Pos. Load Sensing [04] [LS*] 3-Way 3-Pos. [03] 4-Way 3-Pos. Free Flow [F4] SAE 10 Work Ports [10] SAE 12 Work Ports [12] 24VDC On-off SOL Actuator [SOL-I] 12VDC On-off SOL Actuator [SOL-I]
Item No.
Order Code
Parallel Circuit
Letter code I stands for internal porting. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section.
Item No.
Order Code
Letter code I stands for internal porting. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section.
361
GRESEN - V20
Series V20
V20RP PARALLEL SOLENOID WORK SECTIONS (Housing No. 10954)
Solenoid-Operated (ProportionalEPC) (V20-SOL-I internal pilot porting design).
Bill of Material # Closed Center/ 4-Way 3-Pos. Load Sensing [04] [LS*] 3-Way 3-Pos. [03] 4-Way 3-Pos. Free Flow [F4] SAE 10 Work Ports [10] SAE 12 Work Ports [12] 12VDC EPC Actuator [EPC-I-12] 24VDC EPC Actuator [EPC-I-24]
Item No.
Order Code
Parallel Circuit
Letter code I stands for internal porting. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section.
Item No.
Order Code
Letter code I stands for internal porting. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section.
362
GRESEN - V20
Series V20
V20LS CLOSED CENTER AND LOAD SENSING SOLENOID WORK SECTIONS (Housing No. 8364)
Solenoid-Operated (On/OffSOL) (V20-SOL-I internal pilot porting design).
Bill of Material # Closed Center/ 4-Way 3-Pos. Load Sensing [04] [LS*] 3-Way 3-Pos. [03] 4-Way 3-Pos. Free Flow [F4] SAE 10 Work Ports [10] 24VDC On-off SOL Actuator [SOL-I] 12VDC On-off SOL Actuator [SOL-I]
Item No.
Order Code
Open Center
V20 EPC Load Sensing Valve
Letter code I stands for internal porting. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section. *Load Sensing sections may be used for Closed Center or Load Sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover.
V20LS CLOSED CENTER AND LOAD SENSING SOLENOID WORK SECTIONS (Housing No. 8364)
Solenoid-Operated (Proportional-EPC) (V20-EPC-I internal pilot porting design).
Bill of Material # Open Center Closed Center/ 4-Way 3-Pos. Load Sensing [04] [LS*] 3-Way 3-Pos. [03] 4-Way 3-Pos. Free Flow [F4] SAE 10 Work Ports [10] 24VDC On-off Solenoid Actuator [SOL-I] 12VDC On-off Solenoid Actuator [SOL-I] 12 VDC EPC Actuator [EPC-I-12] 24VDC EPC Actuator [EPC-I-24]
Item No.
Order Code
Letter code I stands for internal porting. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section. *Load Sensing sections may be used for Closed Center or Load Sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover.
363
GRESEN - V20
Series V20
V20RP PARALLEL SOLENOID WORK SECTIONS (Housing No. 10954)
Solenoid-Operated (On/Off) With Handle (V20-SOL-I internal pilot porting design).
Bill of Material # Open Center Closed Center/ 4-Way 3-Pos. Load Sensing [04] [LS*] 3-Way 3-Pos. [03] 4-Way 3-Pos. Free Flow [F4] SAE 10 Work Ports [10] SAE 12 Work Ports [12] 24VDC 12VDC SOL SOL with with Handle Handle [SOL-IH-12] [SOL-IH-24]
Item No.
Order Code
Letter code I stands for internal porting. Letter code H stands for manual lever assembly. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section.
Order Code
Letter code I stands for internal porting. Letter code H stands for manual lever assembly. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section.
364
GRESEN - V20
Series V20
V20RP PARALLEL SOLENOID WORK SECTIONS (Housing No. 10954)
Solenoid-Operated (Proportional-EPC) With Handle (V20-EPC-I internal pilot porting design).
Bill of Material # Open Center Closed Center/ 4-Way 3-Pos. Load Sensing [04] [LS*] 3-Way 3-Pos. [03] 4-Way 3-Pos. Free Flow [F4] SAE 10 Work Ports [10] SAE 12 Work Ports [12] 12VDC 24VDC EPC EPC with with Handle Handle [EPC-IH-12] [EPC-IH-24]
Item No.
Order Code
Letter code I stands for internal porting. Letter code H stands for manual lever assembly. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section.
Item No.
Order Code
Letter code I stands for internal porting. Letter code H stands for manual lever assembly. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section.
365
GRESEN - V20
Series V20
V20LS CLOSED CENTER AND LOAD SENSING SOLENOID WORK SECTIONS (Housing No. 8364)
Solenoid-Operated (On/Off-SOL) With Handle (V20-SOL-I internal pilot porting design).
Bill of Material # Open Center Closed Center/ 4-Way 3-Pos. Load Sensing [04] [LS*] 3-Way 3-Pos. [03] 4-Way 3-Pos. Free Flow [F4] SAE 10 Work Ports [10] 12VDC 24VDC SOL SOL with with Handle Handle [SOL-IH-12] [SOL-IH-24]
Item No.
Order Code
Letter code I stands for internal porting. Letter code H stands for manual lever assembly. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section. *Load Sensing sections may be used for Closed Center or Load Sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover.
V20LS CLOSED CENTER LOAD SENSING SOLENOID WORK SECTIONS (Housing No. 8364)
Solenoid-Operated (Proportional-EPC) With Handle (V20-EPC-I internal pilot porting design).
Bill of Material # Open Center Closed Center/ 4-Way 3-Pos. Load Sensing [04] [LS*] 3-Way 3-Pos. [03] 4-Way 3-Pos. Free Flow [F4] SAE 10 Work Ports [10] 12VDC 24VDC EPC EPC with with Handle Handle [EPC-IH-12] [EPC-IH-24]
Item No.
Order Code
1 20LS-10-04-EPC-IH-12 13650-244 2 20LS-10-03-EPC-IH-12 13650-246 3 20LS-10-F4-EPC-IH-12 13650-248 4 20LS-10-04-EPC-IH-24 13650-271 5 20LS-10-03-EPC-IH-24 13650-273 6 20LS-10-F4-EPC-IH-24 13650-275
Letter code I stands for internal porting. Letter code H stands for manual lever assembly. Because of internal pilot porting, these sections must be stacked directly upstream from the utility section. *Load Sensing sections may be used for Closed Center or Load Sensing applications. When used for non-load sensing applications, the load sensing passage must be blocked off at the right outlet cover.
366
GRESEN - V20
Series V20
V20 TRAVEL LIMITER/MANUAL OVERRIDES
May be added to above Solenoid/EPC positioners
Order Code Bill of Material # Description
Push type manual override Screw type travel limiter/manual override Screw type travel limiter for use with Manual Handle option (Handle End only)
UTILITY SECTIONS FOR USE WITH V20 INTERNALLY PILOTED VALVES (Housing No. 7820)
For use with V20 Internally Piloted Solenoid Work Sections. (Not compatible with Externally Piloted Sections)
Order Code Bill of Material # Description
Utility Section with 12 VDC On-off Pressure Control Cartridge installed. Utility Section with 24 VDC On-off Pressure Control Cartridge installed. Utility Section for use with closed center/load sensing valve assemblies. Utility Section with Continuous-On Pressure Control Cartridge Utility Section for use with SAE #12 Power Beyond Sleeve
V20 Valve Utility Section
Utility Section must be stacked directly upstream from the right outlet cover.
Continuous-On Pressure Control Cartridge 12 VDC Pressure Control Cartridge 24 VDC Pressure Control Cartridge Power Beyond Sleeve, SAE 12 Power Beyond Sleeve, 3/4" NPT
367
GRESEN - V20
Series V20
UNLOADING UTILITY SECTIONS (Housing No. 22952)
Allows closed center, load sensing and pressure compensated work sections to be used with a fixed displacement pump.
Order Code Bill of Material # Description
V20 Unloading Valve Section without Internal Pilot Pressure (Manual Valves) V20 Unloader Valve Section with Internal Pilot Pressure (Solenoid Valves) Option Plugs for Utility Section with Unloading Valve (See Note 2)
NOTE 1: The Unloading Valve section should be stacked next to the inlet cover unless priority sections are required. When priority is required, install unloading valve section downstream of priority pressure compensated sections. Open center, tandem and parallel sections should be stacked downstream of the unloading valve section. NOTE 2: A bag of the following parts will be included to cover several application requirements. Quantity Description Part # 21866-001 3 Pilot Hole Seals 21857-001 2 Section Seals K-20-UNL-PLUGS 21733-001 2 Section Seals 00017-001 1 1/4" NPTF Plug 22962-001 3 Expansion Plugs 6 mm
12 VDC On-off Cartridge Assembly for Solenoid Positioner 12 VDC Proportional Cartridge Assembly for EPC Positioner 24VDC On-Off Cartridge Assembly for Solenoid Positioner 24VDC Proportional Cartridge Assembly for EPC Positioner
K-20-EPC-I
NOTE: These cartridges may be used to convert the above solenoid work sections from on-off to proportional or vice versa. One cartridge per kit.
8650-104 8650-105 8650-106 8650-098 13650-531 8650-119 8650-575 8650-574 8650-630 8650-631
Spring Extended Spool Positioner Kit 3-Position Detent Kit Spool IN Detent w/Spring Return to Neutral Positioner Kit 12VDC Solenoid Actuator (External Pilot Design) 24 VDC Solenoid Actuator (External Pilot Design) Electro Magnetic Spool Release Positioner Kit Hydraulic Remote Spool Positioner Kit Hydraulic Remote w/Override Spool Positioner Kit Pneumatic Spool Positioner Kit 12V DC Solenoid Operated Pneumatic Spool Positioner Kit
*Contains both Bonnets needed. **Cannot be used with Float Spool (K4) or Standard Free Flow Spool (F4).
368
GRESEN - V20
Series V20
Vertical Handle (Black) Vertical Handle (Plain) Horizontal Handle (Black) Horizontal Handle (Plain) Standard Seal Retainer Plate Heavy Duty Seal Retainer Sec. Spool Wiper Complete Bracket (Cast Iron) less Handle and Links Spool Boot Assembly
K-20-1 K-20-2 K-20-3 K-20-4 K-20-5 K-20-6 K-20-7 K-20-8 K-20-9 K-20-10 *K-20-SECT-SEAL
8650-087 8650-088 8650-089 8650-090 8650-091 8650-092 8650-093 8650-094 8650-095 8650-096 13650-405
One Section Two Section Three Section Four Section Five Section Six Section Seven Section Eight Section Nine Section Ten Section Section seal for load sensing and/or solenoid pilot passages.
Stud Assembly Kit
NOTE: When using an 8644 Right End Cover add one section to assure proper stud length. *Kit includes 25 pieces of seal number 21866-001.
369
GRESEN - V20
Series V20
Work Port Options
Includes all necessary Seals.
Item No. Bill of Material # Relief Valve Combination Relief & Anti-Cav Check AntiCavitation Check Assembly 500-1249 Set @ 1200 PSI c/p 1250-1749 Set @ 1700 PSI c/p 1750 - 1999 2000-2599 500 - 3500 Set @ 1950 Set @ 2550 Set @ 2500 PSI c/p PSI c/p PSI c/p
Order Code
1 2
Model RC Work Port Relief Valve
RC-1200 RC-1700 RC-1950 RC-2550 RP20A-2500 CRA-1200 CRA-1700 CRA-1950 CRA-2550 K-20-AC RCS-1200* RCS-1700* RCS-1950* RCS-2550* K-20-ACS*
8650-394 8650-395 8650-396 8650-397 8650-975 8650-387 8650-388 8650-389 8650-390 8650-380 8650-632 8650-633 8650-634 8650-635 8650-636
3 4 5 6 7
8 9 10 11 12 13 14 15
*For use in V20S Series sections only. NOTE: All above Relief Valves have stainless steel springs. Crack Pressures (c/p) set at 1 GPM. RC, CRA, and RCS Relief Valves are internal shim adjustable. RP20A Relief Valve is external screw adjustable.
Order Code
1 2 3 4
K-WH-A
8650-381
Screw Adjustable Option for RC, CRA and RCS Relief Valves.
370
GRESEN - V20
Series V20
V20 MID-INLET AND TRANSITION SECTIONS (Housing No.s 6825, 12138 & 21243)
Item No. Order Code Bill of Material # Split Flow (SF) Combined Flow [CF] SAE 12 Top Inlet [12} 3/4" NPT Top Inlet [75] SAE 16 Top Inlet [16] Load Sense and Pilot Drain [LS] Pressure Reducing Cartridge [PR] Internal Pilot ThruPassage [PILOT]
1 2 3 4 5 6 7 8 9 10
V20 Mid-Inlet Section
20/30-TR-16-PR-LS 13650-079
NOTES: All of the above Mid-Inlet and Transition Sections are machined to accept main relief cartridges . *V20/V50 mid-inlet sections combine V20 work sections (upstream) with V50 work sections (downstream). Standard V50 section stud kits are used for downstream V50 work sections. Special V20 section stud kits listed below are used for upstream V20 work sections. The Pilot code designates that the internal pilot passages have been machined through the Mid-Inlet Section. These sections will allow pilot oil to be available to both upstream and downstream sections.
371
GRESEN - V20
Series V20
Utility Sections For Use With V20 Externally Piloted Valves (Housing No. 7820)
(Not for Use in Internally Piloted Valve Assemblies)
Order Code Bill of Material # Description
Utility Section with 12VDC On-off Pressure Control Cartridge Installed. Utility Section with 24VDC On-off Pressure Control Cartridge Installed. Utility Section with Continuous-On Pressure Control Cartridge Utility Section with SAE #12 Power Beyond Sleeve
20-SOL-E-UT-PB
*Fitting Kits For Externally Piloted V20 and V42 Solenoid Valves
Order Code Bill of Material # Description
For single spool solenoid valve For First section (closest to valve inlet) in a multi-spool solenoid valve. (Last section for Model V42) For the center section(s) in a multi-spool solenoid valve. For the last section (closest to utility section) in a multi-spool solenoid valve. (First section for Model V42)
* Each kit contains one adjustable speed control fitting assembly and one non-adjustable fitting assembly for one actuator assembly.
372
GRESEN - 25P
Series 25P
25P
Gresens Model 25P Directional Control Valve is a stack type valve which allows versatility in porting, assembly of various combinations of the different type working sections, and the addition of working sections in the field as required. 3-way, 4-way, Free Flow, and 4-way 4-position float sections can be combined in assemblies of 1 to 9 spools. Excellent metering characteristics in raising and lowering positions make this valve an excellent choice for precise control of any implement.
35 GPM nominal flow rating Pressures to 2500 PSI Integral inlet/work and outlet/work sections available. Provide economy and flexibility Parallel and Tandem circuit options Manual or solenoid actuator options
Specifications
Pressure Rating: Continuous Operating, Max. . . . . . . . . . .2500 PSI (172,9 bar) Capacity: Nominal Flow . . . . . . . . . . . . . . . . . .35 GPM (133 litres/min) Operating Temperature: . . . . . . . .-40F (-40C) to 176F (80C) Filtration Required (Min.) . . . . . . . . . . . . . . . . .33 micrometre Maximum Exhaust Core Pressure: With Handle Bracket or Heavy Duty Spool Seal Retainer Installed Continuous Operating . . . . . . . . . . . . . . . .1000 PSI (69,0 bar) With Standard Spool Seal Retainer Installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500 PSI (34,5 bar)
GRESEN - 25P
Series 25P
25P LEFT COVER (Housing No. 8089)
Two Port Plugs are furnished with each Cover. One Plug is machined for 1/4" NPT gauge port. Gauge port will be plugged. All Left Covers machined to accept Main Relief Cartridges.
Order Code Bill of Material # Top Inlet and Outlet End Inlet and Outlet 1" NPT Ports (100) SAE 16 Ports (16)
25-LC-100 40-LC-16
8089 Left Cover
8650-058 8650-057
8089 Left Cover with trepan grooves for use with 25P and V40 Valves
Main Relief Options For 25P, V40 and V42 Inlet Covers
Includes all necessary Seals.
Pressure Range, PSI 400-1400 Set @ 1100 PSI c/p 1401-2000 Set @ 2000 PSI c/p 500-5000 Set @ 2500 PSI c/p
Bill of Material #
For use in all 25P, V40 and V42 Inlet Covers NOTE: KC and RP60A Relief Valves are external screw adjustable. Crack Pressure set at 1 GPM.
*1644 Right Cover No trepan grooves, for use with 25P Valves
NOTE: 3/4" NPT plug furnished with 8090 covers for conversion to power beyond. 8090 Right cover No trepan grooves, for use with 25P Valves *1644 Right Cover Identification Covers with 1 hole through inner surface are used for Power Beyond or Closed Center Covers with 2 holes through inner surface (pictured above ) are used for Turn Around or Outlet
374
GRESEN - 25P
Series 25P
25P LEFT INTEGRAL SECTION (Housing No.s 3000 & 3001)
Integral Section Includes Valve Spool and Handle Bracket.
3-Way 1 NPT 4-Way 3-Pos. Inlet & Outlet 3-Pos. [3] Ports [4] [100] SAE 16 Inlet & Outlet Ports [16] Upper & Lower Work Port Options Machined& Plugged [UL]
Order Code
Bill of Material #
3/4" NPT SAE 12 SAE 16 Work Work Work Ports Ports Ports [75} [12] [16]
25-L-T-100-75-04 25-L-T-100-75-UL-04 25-L-T-16-12-UL-04 25-L-T-16-16-04 25-L-E-100-75-04 25-L-E-100-75-UL-04 25-L-E-16-16-04 25-L-E-16-16-UL-04 25-L-E-100-75-W4 25-L-T-16-16-03
8650-372 13650-133 13650-134 8650-371 8650-370 13650-131 8650-369 13650-132 8650-641 13650-824
3001 Left Cover
NOTE: Machined for Main Relief Options. Not machined for gauge port. Bracket Assembly not furnished with Rotary Spool Option [W].
1624 Right Integral Section
Conversion Plug Kit Closed Center Plug Kit SAE 12 Power Beyond Sleeve Kit 3/4" NPT Power Beyond Sleeve Kit
375
GRESEN - 25P
Series 25P
25P PARALLEL WORK SECTIONS (Housing No. 1614)
Includes Handle Bracket.
4-Way 3-Pos. Free Flow [F4] Upper & Upper Lower 3/4" SAE 10 Rotary Stainless Work Port SAE 16 SAE 12 Work Port 4-Way NPT Work Steel Spool Options Work Work Options 4-Pos. Work Actuator Spool Ports Machined Ports Ports Machined Float Ports [SS] [W] [16] & Plugged [10] [12] [75] [K4] & Plugged [U] [UL]
Item No.
Order Code
Bill of Material #
13650-120 8650-343 13650-123 13650-128 8650-364 8650-341 13650-121 8650-339 8650-941 8650-615 8650-479 13650-122 13650-129 13650-130 8650-338 8650-340
6 25-75-04 7 25-75-U-04 8 25-75-UL-04 9 25-75-W4 10 25-10-04 11 25-10-U-04 12 25-12-04 13 25-12-U-04 14 25-12-UL-04 15 25-16-04 16 25-16-UL-04
17 25-16-UL-W4-SS 8650-508 18 25-75-F4 19 25-12-F4 20 25-16-F4 21 25-16-WF4-SS 22 25-75-K4 23 25-75-UL-K4 24 25-10-U-K4 25 25-12-K4 26 25-12-U-K4 27 25-12-UL-K4 28 25-16-K4 29 25-16-UL-K4 8650-337 13650-124 8650-342 8650-509 8650-333 8650-331 8650-480 13650-125 13650-126 13650-127 8650-332 8650-330
NOTE: Bracket Assembly not furnished with Rotary Spool Option [W], Items 9, 17 and 21. When using (K4) Float Sections in Model 25P Control Valve assemblies, it must be placed next to the inlet cover. Only ONE float section may be used in the valve assembly.
376
GRESEN - 25P
Series 25P
Upper Work Port Relief Options for 25P and V42 Control Valves Relief Model YC
Pressure Range and Setting Order Code Bill of Material # 500-1000 Set @ 1000 PSI c/p 1001-1500 Set @ 1500 PSI c/p 1501-3000 Set @ 3000 PSI c/p YC Relief Valve Cartridge
NOTE: All the above Relief Valves have stainless steel springs. Model WH Relief Valves are internal shim adjustable. Model RP51 Relief Valves are external screw adjustable. Crack Pressure (c/p) set at 1 GPM.
Screw adjustable option for WH Relief Upper Anti-Cavitation Check Lower Anti-Cavitation Check
Lower Anti-Cavitation Check
MID INLET SECTIONS FOR 25P AND V40 CONTROL VALVES (Housing No. 3953)
Order Code Bill of Material # Combined Flow w/Top Inlet [CF] 1" Port [100] SAE 16 Port [16]
25-100-CF 40-16-CF
8650-055 8650-056
3953 Mid-Inlet Section
NOTE: Machined to accept the same relief options as the Left Inlet Cover.
K-40-SF K-40-CF
8650-080 13650-929
Mid-Inlet Conversion Kit to Split Flow Mid-Inlet Conversion Kit to Combined Flow
377
GRESEN - 25P
Series 25P
Spool Positioner Option Kits
Order Code Bill of Material # Description
Spring Extended Spool Positioner Kit 3-Position Detent Kit Spool IN Detent w/Spring Return to Neutral Positioner Kit Rotary Spool Positioner Kit Spool Travel Limiter Pneumatic Spool Positioner Kit
K-25-L K-PA100-25
NOTE: The above kits will not work with Float or Regenerative Spools.
K-25-VH-B
Vertical Handle
Vertical Handle Assembly (Black) Vertical Handle Assembly (Plain) Horizontal Handle Assembly (Black) Horizontal Handle Assembly (Plain) Spool Boot Assembly (See Note) Male Spool Clevis
Horizontal Handle
NOTE: * Special Order Only Standard Distributor Stock sections do not have boot grooves in spools.
Bill of Material #
Bill of Material #
Bill of Material #
Bill of Material #
1 2 3 4 5 6 7 8
378
GRESEN - V42
Series V42
V42
Gresens Model V42 Directional Control Valve is designed for parallel hydraulic circuit applications, up to 3500 PSI (242 bar) continuous operating pressure. Pressure is limited to 2000 PSI (136 bar) if NPT pipe ports are required. For pressures beyond 2000 PSI, SAE straight thread O-ring ports or BSP ports are required. Service or conversion is simple since individual sections can be added, removed or replaced in the field. Individual service or field conversion sections, rather than complete valve assemblies, can be stocked thus reducing inventories. The Model V42 is a parallel circuit valve. Two or more spools may be actuated at the same time and the oil will follow the path of least resistance. If a 2-spool valve is used to control two hydraulic cylinders, each with a different load, the cylinder with the lightest load will operate first if both spools are fully actuated at the same time. If the spool controlling the cylinder with the light load is metered (not fully actuated), then both cylinders may be operated at the same time. When a spool is fully actuated, the open center core is blocked and oil is directed into the power core. Oil is then available to the work ports of all sections in the valve assembly.
40 GPM nominal flow rating Pressures to 3500 PSI Manual or solenoid actuator options Manual, solenoid, hydraulic remote or pneumatic actuator options. Mid inlet for combination and split flow applications
Specifications
Pressure Rating: Continuous Operating. . . . . . . . . . . . . . .*3500 PSI (242 bar)
*Limited to 2000 PSI (136 bar) when NPT pipe ports are used
Capacity: . . . . . . . . . . . . . . . . . . . . . .Flow rate is determined by the maximum pressure drop acceptable for the application Operating Temperature: . . . . . . . .-40F (-40C) to 176F (80C) Filtration Required (Min.) . . . . . . . . . . . . . . . . .33 micrometre Weight: Inlet Cover . . . . . . . . . . . . . . . . . . . . .Approx. 12 lbs. (5,4 kg) Outlet Cover . . . . . . . . . . . . . . . . . . . . .Approx. 6 lbs. (2,7 kg) Work Section, Each . . . . . . . . . . . . . .Approx. 15 lbs. (6,8 kg)
379
GRESEN - V42
Series V42
V42 LEFT COVERS (Housing No.s 8089 & 8288)
Order Code 8089 Left Cover Bill of Material # Top Inlet & Outlet End Inlet & Outlet SAE 20 [20] With Pressure Reducing Valve for Solenoid Option
42-LC-20 42-LC-20-P
8650-032 8650-033
NOTE: Two Port Plugs are furnished with each cover. One Plug is machined for 1/4" NPT gauge port. Gauge port will be plugged. All inlet Covers machined to accept Relief Cartridges.
8288 Left Cover Trepan grooves not machined. Use with V42 Valves
Main Relief Options for 25P, V40 and V42 Inlet Covers
Includes all necessary Seals.
Order Code RP60A Relief Valve Cartridge Bill of Material # Pressure Range, PSI 500-5000 Set @ 2500 PSI c/p
RP60A-2500 K-40-NR
8650-393 8650-379
NOTE: Above Relief Valve has stainless steel spring and is external screw adjustable. Crack Pressure (c/p) set at 1 GPM.
*8091 Right Cover Trepan grooves machined for use with V42 Valves
Order Code
8090 Right Cover Trepan grooves machined for use with V42 Valves
NOTE: 3/4" NPT plug furnished with 8090 covers for conversion to power beyond. 8287 Right cover Trepan grooves machined for use with V42 Valves *8091 Right Cover Identification Covers with 1 hole through Inner Surface are used for Power Beyond or Closed Center Covers with 2 holes through Inner Surface (pictured above) are used for Turn Around or Outlet
380
GRESEN - V42
Series V42
V42 PARALLEL WORK SECTIONS (Housing No. 8045)
Includes Handle Bracket.
4-Way 3-Pos. [4] 3-Way 3-Pos. [3] 4-Way 3-Pos. Free Flow [4] 4-Way Rotary 4-Pos. 3 Pos. Spool Float Detent Actuator Assembly [D] [W] [K4] SAE 12 SAE 16 Work Work Ports Ports [12] [16] Internal Upper & Hydraulic Hydraulic StainUpper Lower Detent Remote 12 VDC less 24 VDC Options Options Release Actuator Solenoid Steel Solenoid Machined Machined & Set @ 2000 [HRO] [SOL] Spool [SOL] & Plugged Plugged PSI [HRH] [SS] [U] [UL] [KO]
Item No.
Order Code
Bill of Material #
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
42-12-03 42-12-U-03 42-16-U-03 42-12-04 42-12-U-04 42-12-UL-04 42-12-F4 42-12-K4 42-16-F4 42-16-UL-04 42-16-DF4 42-16-U-K04-2000 42-16-04-HRO 42-16-04-HRH 42-16-04-SOL-12 42-16-UL-DF4 42-16-04 42-16-U-04 42-16-UL-W4-SS 42-16-WF4-SS 42-16-W4 42-16-04-SOL-24 42-16-U-F4 42-16-UL-F4
13650-138 13650-142 8650-038 13650-137 13650-140 13650-141 13650-139 13650-143 8650-040 8650-041 8650-050 8650-616 8650-581 8650-580 8650-044 8650-047 8650-481 8650-617 8650-511 8650-510 8650-642 13650-281 13650-284 13650-285
NOTE: Bracket Assembly not furnished with Rotary Spool Option [W], items 19, 20 and 21 and Hydraulic Remote Option [HRO] [HRH] Items 13 and 14.
381
GRESEN - V42
Series V42
V42 SPECIAL WORK SECTIONS, (Housing No.s 8046, 8138 & 8675)
Includes Handle Bracket.
4-Way 3-Position [4] 4-Way 4-Position [K4] 4-Way 4-Position Regenerative [RG4] SAE 16 Work Ports [16] Tandem Circuit [T] Upper Options Machined & Plugged [U] Upper & Lower Options Machined & Plugged [UL]
Order Code
Bill of Material #
42-16-UL-K4
8138 Regenerative Work Section or 8046 Float Section
42-16-RG4 42T-16-U-04
42-16-CF 42-16-SF
3953 Mid Inlet Section
8650-048 8650-049
NOTE: Machined to accept the same relief options as the Left Inlet Cover.
K-40-SF K-40-CF
8650-080 13650-929
Mid Inlet Conversion Kit to Split Flow Mid Inlet Conversion Kit to Combined Flow
Upper Work Port Relief Options for 25P and V42 Control Valves Relief Model YC
Pressure Range and Setting Order Code Bill of Material # 500-1000 Set @ 1000 PSI c/p 1001-1500 Set @ 1500 PSI c/p 1501-3000 Set @ 3000 PSI c/p
YC-1000
YC Relief Valve Cartridge
YC-1500 YC-3000
382
GRESEN - V42
Series V42
Relief Models WH and RP51
Pressure Range and Setting Order Code Bill of Material # 500-1249 Set @ 1200 PSI c/p 1250-1749 Set @ 1700 PSI c/p 1750-1999 Set @ 1950 PSI c/p 2000-2599 Set @ 2550 PSI c/p 2501-3000 Set @ 3000 PSI c/p 500-3500 Set @3000 PSI c/p
NOTE: All the above Relief Valves have stainless steel springs. Model WH Relief Valves are internal shim adjustable. Model RP51 Relief Valves are external screw adjustable. Crack Pressure (c/p) set at 1 GPM.
Screw Adjustable Option for WH Relief Upper Anti-Cavitation Check Assembly Lower Anti-Cavitation Check Assembly
Lower Anti-Cavitation Check
Spring Extended Spool Positioner Kit 3-Position Detent Kit Spool IN Detent w/Spring Return to Neutral Positioner Kit Rotary Spool Positioner Kit 12VDC Solenoid Actuator 24VDC Solenoid Actuator Hydraulic Remote Spool Positioner Kit Hydraulic Remote Spool Positioner Kit w/Override Pneumatic Spool Positioner Kit
Spool Action Assembly (Bonnet)
NOTE: The above kits will not work with Float, Hydraulic Detent Release (KO), or Regenerative spools. *Contains both Bonnets required.
383
GRESEN - V42
Series V42
Handle End Option
Handle Kit contains necessary Links and Pins.
Order Code Bill of Material # Description
Vertical Handle Assembly (Black) Vertical Handle Assembly (Plain) Horizontal Handle Assembly (Black) Horizontal Handle Assembly (Plain) Standard Seal Retainer Plate Spool Boot Assembly Male Spool Clevis
Horizontal Handle
One Section Two Section Three Section Four Section Five Section Six Section Seven Section Eight Section
K-42-TUBE
8650-486
384
GRESEN - V50
Series V50
V50
50 GPM nominal flow rating Pressures to 3500 PSI Series, Parallel and Tandem circuit options Manual, hydraulic remote or pneumatic actuator options
Gresens Model V50 Directional Control Valve is available for parallel, tandem and combined parallel/tandem hydraulic circuit applications, up to 3500 PSI (242 bar) continuous operating pressure. Its new spool design has resulted in lighter spool actuating effort making its finger-tip touch and extra fine metering characteristics ideal for back hoe, front end loader, personnel lift, as well as heavy duty crane applications. This sensitivity also gives the design engineer a wider latitude of mechanical linkage possibilities. Service or conversion is simple since individual sections can be added, removed or replaced in the field. Individual service or field conversion sections, rather than complete valve assemblies, can be stocked thus reducing inventories.
Specifications
Pressure Rating: Continuous Operating, Max. . . . . . . . . . . .3500 PSI (242 bar) Capacity: Nominal Flow . . . . . . . . . . . . . . . . . .50 GPM (189 litres/min) Maximum flow rate is determined by the maximum pressure drop acceptable for the application Operating Temperature: . . . . . . . .-40F (-40C) to 176F (80C) Filtration Required (Min.) . . . . . . . . . . . . . . . . .33 micrometre Weight: Inlet Cover . . . . . . . . . . . . . . . . . . . . .Approx. 18 lbs. (8,2 kg) Outlet Cover . . . . . . . . . . . . . . . . . . . .Approx. 11 lbs. (5,0 kg) Work Section, Each . . . . . . . . . . . . . .Approx. 17 lbs. (7,7 kg)
385
GRESEN - V50
Series V50
V50 LEFT COVERS (Housing No. 8916)
Order Code Bill of Material # End Inlet [E] Top Inlet [T] End Outlet [E] Top Outlet [T] 1/4" NPT Gauge Port Plugged SAE 20 Port Size [20]
50-LC-20-E 50-LC-20-T
8916 Left Cover
8650-535 8650-536
NOTE: All Left Covers are machined to accept Main Relief Valve, Model RP50A.
K-50-NR
Model RP50A Relief Valve Cartridge
8650-561 8650-560
RP50A-2500
NOTE: Above Relief Valve has stainless steel spring and is external screw adjustable from 500 to 3500 PSI. Relief Valve Cartridge set at 2500 PSI crack (c/p) at 1 GPM.
50-RC-20-ETY
22691 Right Cover
13650-650
NOTE: Top Port plugged. End port may be converted to Closed Center or Power Beyond using Option Kits below.
386
GRESEN - V50
Series V50
V50 WORK SECTIONS (Housing No.s 8917 & 8918)
3-Way or 4-Way Sections include Handle Brackets* and drilled and plugged work port options.
Item No. Bill of Material # 4-Way 3-Pos. [4] 3-Way 3-Pos. [3] Free Flow Motor Spool [F] 4-Way 4-Position Float [K4] SAE 16 Work Ports [16] 3-Position Detent [D] Hydraulic Remote Spool Actuator [HR] Tandem Circuit [T] Series Circuit [S]
Order Code
1 2 3 4 5 6 7 8 9 10 11 12 13
50-16-03 50-16-F3 50-16-04 50-16-F4 50-16-DF4 50-16-K4 50-16-04-HR 50-16-F4-HR 50T-16-03 50T-16-04 50T-16-K4 50T-16-04-HR 50S-16-04
8650-538 8650-539 8650-540 8650-541 8650-542 8650-543 8650-544 8650-545 8650-546 8650-547 8650-548 8650-549 13650-144
V20/V50 Split Flow Transition Mid Inlet V20/V50 Combined Flow Transition Mid Inlet V50 Split Flow Mid Inlet V50 Combined Flow Mid Inlet
NOTE: All sections machined to accept main relief cartridges. For cartridges, refer to page 48. V20/V50 mid-inlet sections combine V20 work sections (upstream) with V50 work sections (downstream) Standard V50 section stud kits are used for downstream V50 work sections Special V20 section stud kits listed on page A-9 are used for upstream V20 work sections
387
GRESEN - V50
Series V50
Section Stud Assembly Kits
Includes Section Seals and Nuts.
Order Code Bill of Material # Number of Work Sections
One Section Two Section Three Section Four Section Five Section Six Section
3-Position Detent Pneumatic Spool Positioner Kit Hydraulic Remote Spool Positioner Kit Hydraulic Remote with Override Spool Positioner Kit
*K-50-HRO
*Contains both bonnets needed.
RP50A-2500
Model RP50A Relief Valve Cartridge
Pilot-Operated Relief Cartridge Combination Relief & Anti-Cav. Anti-Cavitation Check No Relief Plug Kit (NR Option)
NOTE: All above Relief Valves have stainless steel springs and are external screw adjustable. Crack Pressure (c/p) set at 1 GPM.
388
SP
The Gresen Model SP Directional Control Valve is manufactured to give outstanding, long-lasting performance. Spools are hone-fitted for above average load-hold characteristics. Model SP Valves are available either 3-way (single-acting), 4-way (double-acting) or with combinations of both. Monoblock valve housings are available in 1-, 2-, and 3-spool configurations. Optional spools, bonnet assemblies and ports are available on special order.
Shipping Weights
1-Spool . . . . . . . . . . . . . . . .151/2 lbs (7,03 kg) 2-Spool . . . . . . . . . . . . . . . . .24 lbs (10,89 kg) 3-Spool . . . . . . . . . . . . . . .321/2 lbs (14,74 kg)
SPK
The Model SPK Directional Control Valve is available in 1-, 2-, or 3-spool configurations. The No. 1 spool is always a 4-way float spool. Spools No. 2 and No. 3 are either 3-way or 4-way, the same as in the SP valve. The float spool is the same as the 4-way, 3-position spool, with the addition of a fourth Float position. When in Float position, the pump flow is directed to the tank through the open center core. Both work ports are open to the tank. Applications for valves with Float positions are bulldozers, snow plows and other types of equipment that require a combination of both Float and Hold when in neutral.
Features
Detent in Float Position (Spool No. 1 only). Adjustable or Non-Adjustable Ball/Spring Type Relief Valve. Model WK Differential Poppet Relief available. Built-In Load Checks - One Check for A Port Circuit and one for B Port Circuit. Control Handles may be mounted in UP or DOWN position. Power Beyond Outlet Available.
Shipping Weights
1-Spool . . . . . . . . . . . . . . . .171/2 lbs (7,94 kg) 2-Spool . . . . . . . . . . . . . . .231/2 lbs (10,66 kg) 3-Spool . . . . . . . . . . . . . . .291/2 lbs (13,38 kg)
The Model SSK 2-Spool Directional Control Valve is designed for Series Circuit Operation, which allows the simultaneous operation of two cylinders or motors by directing the discharge oil from the cylinder or motor controlled by the No. 1 spool to the cylinder or motor controlled by the No. 2 spool. The No. 1 spool is a 4-way, 4-position float spool. This spool is spring-centered to neutral in 3 positions with a detent provided for the Float position. The No. 2 spool is a 4way, 3-position spool with spring return to neutral from both work ports. For use in any Open Center circuit where it is necessary to actuate two different functions simultaneously.
SSK
Features
Available in 2-spool model only. Detent in Float Position (Spool No. 1 only). Adjustable or Non-Adjustable Ball/Spring Type Relief Valve. Model WK Differential Poppet Relief available. Built-In Load Checks - One Check for each spool. Control Handles may be mounted in UP or DOWN position. Power Beyond Outlet Available.
Shipping Weights
2-Spool . . . . . . . . . . . . . . . . .24 lbs (10,89 kg)
389
SP 1-Spool (See Note 1) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 SP-4-HP SPXTE-4-HP-SS SP-D4-HP SP-W4-HP SPXTE-W4-HP-SS SPXTE-F4-HP SPXTE-4-HP SP-3-HP SPXTE-3-HP GSP-4-HP GSPXTE-4-HP SP-4-4-HP SPXTE-4-4-HP SPXTE-4-4-HP-SS GSPXTE-4-4-HP SPXTE-4-3-HP SPXTE-3-4-HP SPXTE-3-4-4-HP SP-4-4-4-HP SPXTE-4-4-4-HP-SS SPXTE-4-4-4-HP GSPXTE-4-4-4-HP SPK-4-HP SPKXTE-4-HP GSPKXTE-4-HP SPK-4-4-HP SPKXTE-4-4-HP GSPKXTE-4-4-HP SPK-4-4-4-HP SPKXTE-4-4-4-HP GSPKXTE-4-4-4-HP SSKXT-4-4-HP 8650-674 8650-936 8650-673 8650-671 8650-937 8650-938 8650-670 8650-668 8650-665 8650-667 8650-666 8650-664 8650-663 8650-662 8650-661
8650-660 #1-Spool #2-Spool 8650-659 #2-Spool #1 Spool 8650-658 #2 Spool #3 Spool #1 Spool 8650-657 8650-939 8650-655 8650-653 8650-652 8650-651 8650-650 8650-649 8650-648 8650-647 8650-646 8650-645 8650-644 8650-643
390
Inlet - 3/4" NPT Work Ports - 1/2" NPT Outlets - 3/4" NPT
Inlet - SAE 12 Work Ports - SAE 10 Outlet - Standard, SAE 12 End With Optional Conversion Machining (X) SAE 10 (Top or End)
3/4" NPT Power Beyond Sleeve Kit SAE #10 Power Beyond Sleeve Kit SAE #12 Power Beyond Sleeve Kit Closed Center Plug Kit Conversion Plug Kit
Power Beyond Sleeve
3-Position Detent Kit Detent Stop for Neutral & Spool Out or Spool In Spring Extended Spool Spool IN Travel Limiter, Adjustable
Standard Handle (Black) Standard Handle (Plain) Link and Pin Kit for SP Handles
SP Handle
Relief Kit
Order Code Bill of Material # Description
K-SP-NR
8650-211
391
300
The Model 300 Valve was designed to control a single-acting cylinder or a uni-directional hydraulic motor. The spool in this valve is a 3-way, 3-position spool - the 3 positions are Power, Neutral, and Exhaust. B Port is always the power port and A port is always plugged.
Features
Built-In Relief Valve, Shim adjustable (optional). Replaceable, Hardened Relief Valve Seats. Built-In Load Check.
The Standard Model 300 Valve is spring-centered to neutral position with work port blocked in neutral. Optional spool and spool positioner assemblies are available. This valve, available in single-spool housing only, is ideal for general mobile and industrial hydraulic applications.
400
Features
Built-In Relief Valve, Shim adjustable (optional). Replaceable, Hardened Relief Valve Seats.
The Model 400 Valve was designed to control a double-acting cylinder or a reversible hydraulic motor. The standard spool in this valve is a 4-way, 3-position spool. The Model 400 Valve cannot be converted to a 3-way valve.. The Model 400 Valve does not have a load check assembly to prevent reverse flow. The spool is spring-centered to Neutral position with cylinder ports blocked in neutral. Optional spool and spool positioner assemblies are available This valve, available in single-spool housing only, is ideal for general mobile and industrial hydraulic applications.
Operating Temperature: . . . . . . . .-40F (-40C) to 176F (80C) Filtration Required (Min.) . . . . . . . . . . . . . . . . .33 micrometre Port Sizes: Inlet and Outlet Ports . . . . . . . . . . . . . . . . . . . . . . . . . .3/4 NPT Work Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/2 NPT Shipping Weight: . . . . . . . . . . . . . . . . . . . . . .81/4 lbs. (3,74 kg)
392
300 Valve
NOTE: All valves include relief set @ 1500 PSI @ 7.6 GPM - shim adjustable. Standard porting includes 1/2" NPT work ports, 3/4" NPT inlet and outlet ports. SAE porting is SAE 12 Inlet and SAE 10 ports. Optional porting includes SAE #10 work ports and SAE #12 Inlet and Outlet ports. 400 Valve
K-400-D K-400-A
8650-141 8650-143
Three Position Detent for Models 300 and 400 Spring Extended Spool for Models 300 and 400
Spool Action Assembly (Bonnet)
Port Plugs
PORT PLUGS
For use with all directional control valves.
Order Code Bill of Material # Description
K-NPT-13 K-NPT-25 K-NPT-38 K-NPT-50 K-NPT-75 K-NPT-100 K-NPT-125 K-SAE-6 K-SAE-8 K-SAE-10 K-SAE-12 K-20-X K-SAE-16 K-SAE-20 K-SAE-24
8650-306 8650-307 8650-308 8650-309 8650-310 8650-305 8650-304 8650-296 8650-297 8650-298 8650-299 8650-100 8650-301 8650-302 8650-303
1/8" NPTF Pipe Plug 1/4" NPTF Pipe Plug 3/8" NPTF Pipe Plug 1/2" NPTF Pipe Plug 3/4" NPTF Pipe Plug 1" NPTF Pipe Plug 1 1/4" NPTF Pipe Plug Includes 2825-100 SAE 6 Plug and 2705-001 Seal Includes 2684-001 SAE 8 Plug and 2706-001 Seal Includes 1458-001 SAE 10 Plug and 2707-001 Seal Includes 1726-001 SAE 12 Plug and 2708-001 Seal Includes 1727-001 SAE 14 Plug and 2709-001 Seal Includes 1629-001 SAE 16 Plug and 2710-001 Seal Includes 6280-001 SAE 20 Plug and 6281-001 Seal Includes 8095-001 SAE 24 Plug and 3640-001 Seal
SAE Plug NPT Plug
393
SERIES
VALVE
Series circuits unload the pump flow to tank when all 4-ways are in the center position. Pump flow passes through each valve making the pressure drops additive. Series circuits have the capability, when energizing two valves, of positive motion of two functions by using exhaust flow from the upstream actuator. Cautions to observe when applying valves in series circuits are pressure and flow intensification from differential cylinders and the effects of back pressure on upstream functions.
PARALLEL
VALVE
Parallel circuits have pressure blocked in neutral and are generally used with pressure compensated pumps or some type of unloading valve. Parallel circuits do not have the problems of pressure and flow intensification but will not insure motion of more than one actuator when two valves are energized at the same time.
PARALLEL WITH UNLOADING RELIEF This circuit gives the advantages of parallel with the added feature of unloading a fixed displacement pump. The circuit incorporates a normally open solenoid operated relief to unload the pump. The solenoid on the relief valve is wired so that it is energized every time a valve is actuated and closes the vent on the relief valve.
394
MD04-SDNC-AB-12B MD04-SDNC-AD-12B
994542-12B 994511-12B
Model MD04
MD04-SDNC-DD-12B 994526-12B
SAE 1/4" blade terminals, 12 VDC, standard. Consult factory for other options.
Model MD06 Spool Options 4-Way 3-Position [D] 4-Way Free Flow [B]
Order Code
SAE /4" blade terminals, 12 VDC, standard. Consult factory for other options.
395
MR-06-RFN
994436
Section Stud Assembly Kits, 1/4" and 3/8" (Series) With Inlet Relief Section
Includes tie bolts, mounting feet and nameplate.
Order Code Bill of Material # Number of Work Sections
K-708162 w/Relief K-708163 w/Relief K-708164 w/Relief K-708155 w/Relief K-708156 w/Relief
One Section Two Section Three Section Four Section Five Section
One Section Two Section Three Section Four Section Five Section
Model MD06 Spool Options A&B To Tank [J] Free Flow [B] 2-Pos. [M]
MD06-PDNC-AA-12B MD06-PDNC-AJ-12B MD06-PDNC-AB-12B MD06-PDNH-AA-12B MD06-PDNA-AM-12B MD06-PDNC-RA-12B MD06-PDNC-RJ-12B MD06-PDNC-SA-12B MD06-PDNC-SJ-12B MD06-PDNC-DA-12B
999300-12B 999305-12B 999301-12B 999320-12B 999341-12B 999375-12B 999311-12B 999334-12B 999306-12B 999321-12B
SAE 1/4" blade terminals, 12 VDC, standard. Consult factory for other options.
396
HM
Model H
The Models H and HM Float Position Valves are used with standard 4-way, 3-position valves to provide a float or freewheeling position. These valves are designed for snow plows, loaders, winches and similar equipment applications which may require the optional function of having a cylinder able to float or a motor to free-wheel. The hydraulic circuit which is to be operated should be selected before pressure is applied.
Model HM
Specifications
H Capacity (nominal): . . . . . . . . . . . . . . . . . .25 GPM (94 litres/min) Maximum Operating Pressure: . . . . . . . . .3000 PSI (207 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . .51/2 lbs (2,5 kg) HM 10 GPM (37 litres/min) 2000 PSI (138 bar) 23/4 lbs (1,3 kg)
397
S
3 SIZES FROM WHICH TO CHOOSE S-50 S-75 S-100
Features
Pressure Balanced Spool Chrome Plated Spool High-Tensile Cast Iron Body Easy to Mount
The Model S, Two-Position, Selector Valves offer a simple method of directing the flow of hydraulic oil to two separate hydraulic lines. The addition of these Selector Valves to the hydraulic circuit will permit operation of two single-acting cylinders with one three-way control valve. In some applications, two double acting cylinders may be operated with one 4-way control valve. The hydraulic circuit which is to be operated should be selected before pressure is applied. Valve Spool is of the open crossover type. As Spool is moved and one outlet port starts to close, the other outlet port starts to open. Three sizes; 15 GPM (56litres/min), 24 GPM (90 litres/min), and 40 GPM (151 litres/min) permit selection for any application
Specifications
S-50 Capacity (nominal): . . . . . . . . . . . . . . . . . .15 GPM (56 litres/min) Maximum Operating Pressure: . . . . . . . . .3000 PSI (207 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . .23/4 lbs (1,3 kg) S-75 S-100 24 GPM 40 GPM (90 litres/min) (151 litres/min) 3000 PSI 3000 PSI (207 bar) (207 bar) 51/2 lbs 91/2 lbs (2,5 kg) (4,3 kg)
398
SM
The Model SM, Two-Position, Selector Valve is a two-way hydraulic selector offering a simple method of directing the flow of oil in a hydraulic system to two separate hydraulic lines. The addition of this Selector Valve to the hydraulic system will permit operation of two single-acting cylinders with one three-way control valve. In some applications, two double acting cylinders may be operated with one 4-way control valve. The hydraulic circuit which is to be operated should be selected before pressure is applied. Valve Spool is of the open crossover type. As Spool is moved and one outlet port starts to close, the other outlet port starts to open.
Specifications
SM Capacity (nominal): . . . . . . . . . . . . . . . . . .20 GPM (75 litres/min) Maximum Operating Pressure: . . . . . . . . .2000 PSI (138 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . .23/4 lbs (1,3 kg)
399
DS
Features
Pressure Balanced Spool Chrome Plated Spool High-Tensile Cast Iron Body Three Handle Position Options
The Model DS, Two-position, Double selector Valve directs the flow of hydraulic oil to two separate circuits. This permits operation of two doubleacting cylinders with one four-way control valve or four single-acting cylinders with two three-way control valves. The hydraulic circuit which is to be operated should be selected before pressure is applied. Valve Spool is of the open crossover type. As Spool is moved and one outlet port starts to close, the other outlet port starts to open.
Specifications
Capacity (nominal): . . . . . . . . . . . .20 GPM (75 litres/min) Maximum Operating Pressure: Model DS-75 . . . . . . . . . . . . . . . . . . .2000 PSI (138 bar) Model DS-12 . . . . . . . . . . . . . . . . . . .3000 PSI (207 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . .12 lbs (5,5 kg)
400
Directional Controls
MODEL HM 3-WAY (FLOAT) VALVES
(Two Position)
Order Code Bill of Material # Port Size
3
Knob/Clevis Option
HM-38 HM-38-R HM-50 HM-50-R HM-50 w/Clevis H-75 HM-8 HM-8 w/Clevis H-12 H-12 w/Clevis
07254035 07254047 07254019 00983034 00983098 07251015 07254039 07254046 07251019 07251030
/8" NPT /8" NPT /2" NPT /2" NPT /2" NPT /4" NPT SAE 8 SAE 8
Knob Knob Knob Knob Clevis Knob Knob Clevis Knob Clevis
Model HM
SAE 12 SAE 12
Knob/Clevis Option
S-50 S-50-L/Knob S-50 w/Clevis S-50-R S-50-R w/Clevis S-75 S-75 w/Clevis S-75-R S-100 S-100-R S-8 S-8 w/Clevis S-8-R S-8-R-L/Knob S-8-R w/Clevis S-10 S-10-L/Knob & Clevis S-10 w/Clevis S-10-R-L/Knob & Clevis S-10-R w/Clevis S-10-R w/Knob S-12 S-12-L/Knob & Clevis S-12 w/Clevis S-12-R S-12-R w/Clevis S-16 S-16 L/Knob S-16 w/Clevis S-16-R
07252004 07252001 07252007 07252006 07252023 07251002 07251004 07251021 07253001 07253002 07252018 07252029 07252033 07252034 00983053 07252012 07252021 07252045 07252056 07252013 07252025 07251010 07251009 07251018 07251028 07251011 07253007 07253019 07253017 07253008
/2" NPT /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 1" NPT 1" NPT SAE 8 SAE 8 SAE 8 SAE 8 SAE 8 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 12 SAE 12 SAE 12 SAE 12 SAE 12 SAE 16 SAE 16 SAE 16 SAE 16
Knob Clevis Knob Clevis Knob Clevis Knob Knob Knob Knob Clevis Knob Clevis Knob Clevis Clevis Knob Knob Clevis Knob Clevis Knob Clevis Knob
Model S
401
Directional Controls
MODEL SM SELECTOR VALVES
Order Code Bill of Material # Port Size
3 3
Knob/Clevis Option
Detent
Model SM
SM-38 SM-38-L/Knob SM-38-R SM-38-R-L/Knob SM-38-S1 SM-50 SM-50 w/Clevis SM-50 L/Clevis or Knob SM-50 w/1688 Clevis SM-50-R SM-50-R-L/Knob SM-50-S1 SM-50-S1 w/Clevis SM-8 SM-8-L/Knob SM-8 w/Clevis SM-8 w/Detent & Clevis SM-8-R SM-8-R-L/Knob SM-8-R with Detents SM-8-S1 SM-8-S1 w/Clevis
07254009 07254007 07254056 07254008 00983031 07254003 07254006 07254022 07254060 07254005 07254002 00983037 07254031 07254013 07254012 07254016 00983115 07254014 07254024 00982922 07254057 07254065
/8" NPT /8" NPT 3 /8" NPT 3 /8" NPT 3 /8" NPT 3 /8" NPT 1 /2" NPT 3 /8" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT SAE 8 SAE 8 SAE 8 SAE 8 SAE 8 SAE 8 SAE 8 SAE 8 SAE 8
Clevis Knob Knob Clevis Knob Clevis Clevis Knob Knob Knob Clevis
Option Kit
(Models S & SM)
Order Code Bill of Material # Description
K-S-CLV
08650235
Knob/Handle Option
Detent
Viton
07255021 07255029 07255026 07255023 07255020 00983146 00983066 07255008 07255010 07255018 07255012
/4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT
Knob Handle Handle LCHA LHO Handle Handle Handle LCHA LHO LCHA
DS-75 w/Detent w/Handle DS-12 w/Detent w/Handle DS-12 w/Handle Assy. DS-12-LCHA DS-12-LHO DS-16-LCHA
402
LT
MODEL LT
MALE-FEMALE PORTS
LTF
Specifications
Maximum Operating Pressure: . . . . . . .3000 PSI (207 bar)
MODEL LTF
FEMALE-FEMALE PORTS
THROTTLE
CHECK
The Model LT and LTF Valves will operate satisfactorily when installed in any position. These valves may be used as Line Check Valves, permitting full flow of hydraulic oil in one direction only or they may be used as restrictors. An assortment of restrictors are available. When installed, the valve becomes a Line Throttle Valve permitting free flow of hydraulic oil in one direction and a restricted flow in the opposite direction. An array of color-coded poppets allows easy and quick identification and simplifies conversions.
[litres/min] 15,1 .062" HOLE .095" HOLE 1400 1200 .156" HOLE [bar] PSI .189" HOLE 800 .220" HOLE 600 400 CURVE NO. 1 200 13 10 41 27 30 20 55 PSI 1000 69 50 40 .125" HOLE 96 82 1400 60 30,2 45,4 60,5 75,7 90,8 105,9 121,1 136,2 151,4 15,1 30,2 45,4
1600
110
1600
FLOW IN REVERSE DIRECTION OF THAT IN CURVE NO. 1 LT-50 LT-8 LTF-8 LT-10 LTF-10 LT-75 LTF-12 LT-12
136,2 151,4
5,5 4,8 4,1 3214-000 3214-095 3214-125 3214-156 3214-189 3214-220 1,3 CURVE NO. 2 0,6
12
16
20 GPM
24
28
32
36
40
12
16
20 GPM
24
28
32
36
40
[bar]
403
Check Valves
Check Valves
MODEL LT LINE CHECK VALVES
Order Code Bill of Material # Port Size
1
Orifice
Order Code
Bill of Material #
Port Size
Orifice
07133001 07133010 07133002 07133012 07133003 07133004 07133005 07133006 07133007 07133008 07133009 07134001 07134002 07134003 07134004 07134005 07134006 07134007 07134008 07135001 07135010 07135002
/2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT SAE 8 SAE 8 SAE 8
None .047 .062 .078 .095 .109 .125 .141 .156 .189 .252 None .095 .125 .156 .189 .220 .252 .314 None .047 .062
LT-8-9 R LT-8-9R w/O-Ring LT-8-11 BW LT-8-12 Y LT-8-14 O LT-8-15 G LT-8-18 B LT-8-25 LB LT-10-0W LT-10-0W w/O-Ring LT-10-6 P LT-10-9 R LT-10-12 Y LT-10-18 B LT-10-14 O LT-12-00 W LT-12-00 W w/O-Ring LT-12-90 R LT-12-120 Y LT-12-180 B LT-12-250 LB
07135003 00983057 07135004 07135005 07135006 07135007 07135008 07135012 07137001 00983085 07137002 07137003 07137005 07137008 07137006 07139001 00983092 07139002 07139003 07139005 07139007
SAE 8 SAE 8 SAE 8 SAE 8 SAE 8 SAE 8 SAE 8 SAE 8 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 12 SAE 12 SAE 12 SAE 12 SAE 12 SAE 12
.095 .095 .109 .125 .141 .156 .189 .252 None None .062 .095 .125 .189 .141 None None .095 .125 .189 .252
LT-50-12 Y LT-50-14 O LT-50-15 G LT-50-18 BG LT-50-25 LB LT-75-00 W LT-75-90R LT-75-120 Y LT-75-150 G LT-75-180 B LT-75-210 O LT-75-250 LB LT-75-310-LG LT-8-0 W LT-8-4BR LT-8-6 P
K-LTF-8-BODY K-LTF-10-BODY
Model LTF Body
K-LTF-12-BODY
LT Bodies
(Male-Female Ports) Order Code Bill of Material # Description
1
404
Check Valves
Check Valves
Taper Pins (Models LT or LTF)
Order Code Bill of Material # Description
1.50" Length for LT-50, LT-8, & LTF-8 1.75" Length for LT-10 & LTF-10 2.00" Length for LT-75, LT-12, & LTF-12
Color
K-LT-4 K-LT-6 K-LT-8 K-LT-9 K-LT-11 K-LT-12 K-LT-14 K-LT-15 K-LT-18 K-LT-25 K-LT-0
08650431 08650432 08650433 08650434 08650435 08650436 08650437 08650438 08650439 08650440 08650326
.047 .062 .078 .095 .109 .125 .141 .156 .189 .252 Check (No Hole)
Brown Purple Pink Red Beige Yellow Orange Lt. Green Black Lt. Blue White
Color
.095 .125 .156 .189 .220 .252 .281 .314 Check (No Hole)
Red Yellow Green Black Orange Lt. Blue Purple Lt. Grey White
405
Lock Valves
LOCK VALVES
PILOT OPERATED CHECK VALVES MODEL MODEL
LO
MODEL LO
STANDARD
LOA
LO and LOA Lock Valves are designed to lock a cylinder, or part of a circuit, without leakage while a control valve is in a neutral position. Lock Valves function as check valves, allowing flow to a cylinder and blocking reverse flow until pilot pressure is applied to unlock the circuit. These valves may be used to prevent movement of a load while the pressure source is inactive.
Features
Hardened Seats Ball/Spring Checks High-Tensile Cast Iron Body
MODEL LOA
Specifications
LO Capacity (nominal): . . . . . . . . . . . . . . . . . .25 GPM (94 litres/min) Maximum Operating Pressure: . . . . . . . . .3000 PSI (207 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . . .6 lbs (2,7 kg) LOA 10 GPM (37 litres/min) 3000 PSI (207 bar) 23/4 lbs (1,3 kg)
TYPES AVAILABLE
Besides model variations in port sizes and capacities, three different types are available.
SINGLE TYPE (S), Designed for use with a single-acting cylinder or to lock one side of a double-acting cylinder.
OPTIONS
EXPANSION RELIEF (R), prevents build up of pressure in a locked circuit due to temperature rise.
SINGLE-UNLOADING TYPE (SU), available on Model LO only. May be used only with single-acting cylinders. This type unloads the pump after unlocking the circuit. U is stamped on the construction plug for identification.
ORIFICE RESTRICTOR (T), restricts rate of return flow after unloading prevents chattering by maintaining unloading pressure. Not available for Model LOA.
DOUBLE-TYPE (D), used with a double-acting cylinder or motor where it is necessary to lock in two directions.
MANUAL UNLOCK (M), enables circuit to be unlocked manually in event that hydraulic unlocking pressure is insufficient. For S and SU options only. Not available for Model LOA.
406
Lock Valves
LOCK VALVES
PILOT OPERATED CHECK VALVES MODEL MODEL
LD1
LD2
Lock valves are designed to lock a cylinder, or part of a circuit, without leakage while the control valve is in neutral position. Lock valves function as check valves, allowing flow to a cylinder and blocking reverse flow until pilot pressure is applied to unlock the circuit. Model LD1 and LD2 lock valves incorporate a two-stage poppet design which minimizes shock. These valves provide prolonged holding of cylinder position and smooth operation throughout the entire pressure range.
Specifications
Flow Rating (nominal): 1/4" . . . . . . . . . . . . . . . . . . . . . . . . . . .8 GPM (30 litres/min.) 3/8" & 1/2" . . . . . . . . . . . . . . . . . . . . .25 GPM (95 litres/min.) Maximum Operating Pressure: . . . . . . . . . . .3000 PSI (207 bar) Seals: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Viton Filtration: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 micron Decompression Ratio (nominal): 1/4" Single . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10:1 1/4" Double . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8:1 3/8" & 1/2" Single . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.4:1 3/8" & 1/2" Double . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1:1 Opening Ratio: 1/4" Single . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.3:1 1/4" Double . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1:1 3/8" & 1/2" Single . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.4:1 3/8" & 1/2" Double . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1:1 Weights (approx.): 1/4" Single . . . . . . . . . . . . . . . . . . . . . . . . . .1.25 lbs (0,57 kg) 1/4" Double . . . . . . . . . . . . . . . . . . . . . . . . .1.75 lbs (0,79 kg) 3/8" & 1/2" Single . . . . . . . . . . . . . . . . . . . . .2.5 lbs (1,13 kg)
LD1
PILOT OPERATED CHECK VALVES
Nominal Flows of 8 and 25 GPM 3000 PSI, 1/4", 3/8" and 1/2"
Specifications
Flow Rating (nominal): . . . . . . . . . . . . .50 GPM 190 litres/min.) Maximum Operating Pressure: . . . . . . . . . . .3000 PSI (207 bar) Seals: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Viton Filtration: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 micron Decompression Ratio (nominal): . . . . . . . . . . . . . . . . . . . .12:1 Opening Ratio: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1:1 Weights (approx.): Single Valve . . . . . . . . . . . . . . . . . . . . . . . . . . .6 lbs (2,72 kg) Double Valve . . . . . . . . . . . . . . . . . . . . . .10 lbs 8 oz (4,76 kg)
LD2
PILOT OPERATED CHECK VALVES
Nominal Flow of 50 GPM 3000 PSI, SAE 16 Ports
407
Lock Valves
Lock Valves
MODEL LO LOCK VALVES
Pilot Operated Check Valve
Order Code Bill of Material # Type Port Size
1
07259007 07259006 07259004 07259005 07259009 07259065 07259016 07259011 07259010 07259037 07259012 07259038 07259020 07259059 07259062 07259061 07259055 07259023 07259063 07259021 07259046 07259022 07259058
Single Single Single Single Single Unloading Single Unloading Double Double Double Double Double Double Single Single Single Single Unloading Single Unloading Double Double Double Double Double Double Double
/2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT Side 1 Side 1 & 2 Side 1 & 2 Side 2 Side 2 Side 2 Side 1 Side 2
LO-50-SU LO-50-SU-M LO-50-D LO-50-D-R1 LO-50-D-R1-R2 LO-50-D-R1-R2 LP LO-50-D-R2 LO-50-D-R2 LP LO-10-S LO-10-S-M2 LO-10-S-R1 LO-10-SU LO-10-SU-T1 LO-10-D LO-10-D w/HD Piston LO-10-D-R1 HP
SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 Side 1 & 2 Side 1 Side 1 Side 1 Side 1 & 2 Side 1 & 2 Side 1 Side 1
Model LOA
LOA-25-S LOA-25-S-R1 LOA-25-D LOA-25-D-R1 LOA-38-D LOA-38-D-R1 LOA-6-S LOA-6-D LOA-6-D-R1 LOA-C-25-S LOA-C-25-D LOA-C-25-D-R1 LOA-C-25-D-R1-R2 LOA-C-6-S LOA-C-6-S-R1 LOA-C-6-D-R1-R2
07260002 07260001 07260005 07260018 07260009 07260011 07260012 07260008 07260026 07260014 07260015 07260028 07260025 07260029 07260031 07260024
Single Single Double Double Double Double Single Double Double Single Double Double Double Single Single Double
/4" NPT /4" NPT /4" NPT /4" NPT /8" NPT /8" NPT SAE 6 SAE 6 SAE 6 Side 1 Side 1 Side 1 and 2 Side 1 Side 1 and 2 Side 1 Side 1 Side 1
408
Lock Valves
Lock Valves
Option Kits
Pilot Operated Check Valve
Order Code Bill of Material # Description
Thermal Relief Set @ 4000 PSI for LO Lock Valve Thermal Relief Set @ 4000 PSI for LOA Lock Valve Manual Unlock for Single Type LO Valves only
Model LD1
LD1-25-1S LD1-25-1SR LD1-25-1D LD1-25-1DR LD1-25-1DT LD1-25-1DTT LD1-38-1S LD1-38-1D LD1-38-1DR LD1-50-1S LD1-50-1D LD1-50-1DR LD1-06-2S LD1-06-2SR LD1-06-2D LD1-06-2DT LD1-08-2S LD1-08-2SR LD1-08-2ST LD1-08-2D LD1-08-2DR LD1-10-2D
2989238 2987426 2989232 2988493 2989272 2982649 2989256 2989222 2982287 2989254 2987360 2982235 2987346 2982503 2987372 2982463 2987790 2982451 2988459 2987789 2982839 2989224
Single Single Double Double Double Double Single Double Double Single Double Double Single Single Double Double Single Single Single Double Double Double
/8" NPT /8" NPT /2" NPT /2" NPT /2" NPT SAE 6 SAE 6 SAE 6 SAE 6 SAE 8 SAE 8 SAE 8 SAE 8 SAE 8
SAE 10
LD2-16-2S LD2-16-2D
2982734 2982575
Single Double
SAE 16 SAE 16
Model LD2
409
Flow Dividers
PROPORTIONAL TYPE PRESSURE COMPENSATED
FLOW DIVIDER
MODEL MODEL
PD
PDC
The Model PD, Proportional-Type, Pressure-Compensated Flow Divider offers an efficient means of proportionally dividing a single flow of hydraulic oil. The flow ratio from the outlet ports remains constant despite load differences between the ports. Outlet flow ratios are preset at the factory and a range of ratios from 50/50 to 90/10 are available. Flow through the Model PD Divider cannot be reversed. It is a flow divider only not a flow combiner. A Model PDC with a combiner feature is offered by substituting a combiner spool assembly for a standard spool. This feature not only divides flow, but flow may be combined in reverse direction and synchronized in both directions. It is only available with a 50/50 flow dividing ratio. If other ratios are required with the combiner feature, consult the factory. Model PD and PDC Flow Dividers will divide the inlet flow to 10% of the specified, major output flow when used within recommended capacities. Neither model, however, should be construed as a flow regulator. In many applications, actuators can displace fluid different from the ratio of the divider and lockup. A means of re-phasing the actuators is recommended.
Features
P
Pressure Compensated. Optional Model PDC Synchronizes in Both Directions. Cross-Drilled, Shifting-Type Spool provides extremely accurate metering. Six Ratios Available in Model PD. High-Tensile, Cast Iron Body. Hardened Metering Spool.
Low Flow Models (Model PD Only) Low Flow Models (Model PDC Only)
300
21
Specifications
Capacity (nominal) Low Flow Models: . . . . . . . . . . . . . . . . . . .5-20 GPM (18-94 litres/min) High Flow Models: . . . . . . . . . . . . . . . . .20-35 GPM (56-132 litres/min) Maximum Operating Pressure: . . . . . . . . . . . . . . . . . .2500 PSI (172 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . .Approx. 7 lbs (3,2 kg)
100
7.0
10
15
20
25
30
35
410
BAR
PSI
FLOW DIVIDER
MODEL Features
Integral Relief Valve in Constant Flow Circuit. (Adjustable with shims) Also available without Relief Valve (NR). Cross-Drilled, Shifting-Type Spool provides extremely accurate metering. Ten Metering Spool Sizes Available. High Strength, Cast Iron Body. Hardened Metering Spools Are Interchangeable.
CFD
CF
EF
Specifications
Input Capacity (nominal): . . . . . . . . . . . . . . . . . . .20 GPM (75 litres/min) Maximum Operating Pressure: . . . . . . . . . . . . . . . . . .3000 PSI (207 bar) Constant-Flow Relief Valve Pressure Setting: . . . . . . . . . . . . . .Up to 2500 PSI (172 bar) (Cracking) Shipping Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 lbs. (3,6 kg)
Gresens Model CFD, Constant-Volume, Priority-Type Flow Divider is designed for power steering systems and other applications where two separate hydraulic power circuits are to be served from a single pump. Hydraulic oil is divided into two separate flows. One, a constant flow (regardless of input pressure) and the other, a flow in excess of the constant flow. Flow can be reversed through the Controlled Flow Work Port but is not pressure compensated. Hydraulic oil flow through the Excess Flow Port cannot be reversed. The constant flow output is determined by the type of Metering Spool which is installed.
411
FLOW DIVIDER
MODEL
CFDA
Gresens Model CFDA Adjustable Flow Divider offers an inexpensive, dependable means of obtaining flow adjustment up to 15 GPM (15,8 litres/min.). Provides easy manual control where frequent flow change is required. Pressure compensation provides a smooth, constant output flow regardless of pressure changes at the Controlled Flow Work Port. Rotating the adjusting knob varies the flow from the Controlled Flow Work Port. After the controlled flow demand is satisfied, the balance of the inlet flow passes through the Excess Flow Port and returns to the tank. The Excess Flow Port is not a work port. Flow through the Controlled Flow Work Port can be reversed but is not pressure compensated. The Model CFDA is not available with a built-in relief valve.
Features
Adjustable Flow Rate. Cross-Drilled, Shifting-Type Spool provides extremely accurate metering. High Strength, Cast Iron Body. Hardened Metering Spool.
EF TO TANK CF
Specifications
)( )( )( IN
Capacity (nominal) Adjustable: . . . . . . . . . .Up to 15 GPM (56 litres/min) Maximum Operating Pressure: . . . . . . . . . . . . . . . . . .2500 PSI (172 bar) Flow Adjustment: . . . . . . . . . . . . . . . . . . . . . . . . .Approx. 6 turns of knob from min. to max. flow Shipping Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 lbs. (3,6 kg)
PRESSURE DROP Typical Test Figures Using 150 SUS Oil at 100F (37,8C) PRESSURE DROP PRESSURE DROP OUTPUT THRU CF PORT THRU EF PORT GPM (litres/min) PSI (bar) PSI (bar)
3 (11,3) 6 (22,7) 9 (34,0) 12 (45,4) 15 (56,7) 4 (0,2) 7 (0,4) 17 (1,1) 28 (1,9) 40 (2,7) 45 (3,1) 43 (2,9) 40 (2,7) 35 (2,4) 32 (2,2)
412
FLOW DIVIDER
Features
Differential Poppet Relief Valve In The Controlled Flow Circuit also available without relief valve (NR). Available With Adjustable or Non-Adjustable Flow To The Controlled Flow Circuit. Adjustable Divider Offers 12 Flow Adjustment Positions (Positive Detents) in 360 Rotation Of Knob. Non-Adjustable Divider Has An Interchangeable Orifice Restrictor In The Spool to change flow, simply change orifice restrictor not the spool. High Strength, Cast Iron Body. Hardened Metering Spool. Excess Flow Can Be Used In A Secondary Circuit.
MODEL
DC25
Gresens Model DC25 Priority Flow Divider is designed for applications where two separate hydraulic power circuits are to be served from a single pump. The Flow Divider provides priority flow to the primary circuit, and any excess flow to a secondary circuit or tank. An optional hand adjusting knob with 12 positive detent positions is available for readily adjusting the flow from 1 to 20 GPM (3,8 to 76 litres/min) at the controlled-flow port.
Operation
Flow enters the inlet port and passes through a control orifice. The control orifice is of fixed size in the non-adjustable unit or can be varied externally in the adjustable unit. Flow through the control orifice causes a pressure drop, which is sensed across the compensator spool. Any tendency to exceed the flow setting increases this pressure drop causing the spool to shift and bypass the excess flow. If the secondary circuit (excess flow) pressure is greater than the controlled-flow pressure, the spool will shift even further and begin to throttle the controlled-flow to maintain the preset flow. If the controlled-flow port is blocked, the compensator spool will return to the closed position allowing no flow through the Flow Divider. To protect the system, if this condition occurs, an optional differential poppet relief valve may be installed in the controlled-flow circuit to insure flow to the secondary circuit under all operating conditions.
Specifications
Capacity (nominal): Input Flow . . . . . . . . . . . . . . . . . . . . . . .Up To 30 GPM (113 litres/min) Adjustable Controlled-Flow Range . . . . . . . . . . . . . . . . . .1 to 20 GPM (3,8 to 76 litres/min) Adjustable Controlled-Flow Range (14 Orifice Sizes Available) . . . . . . . . . . . . . . . . . .1 to 16 GPM (3,8 to 62 litres/min) Maximum Operating Pressure: . . . . . . . . . . . . . . . . .*3500 PSI (242 bar) Control Accuracy of Controlled-Flow: . . . . . . . . . . . . . . . . . . . . . . . .10% Minimum Operating Pressure Drop: . . . . . . . . . . . . . . . . .70 PSI (4,8 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 lbs. (3,6 kg) Filtration Required (Min.): . . . . . . . . . . . . . . . . . . . . . . . . .33 micrometre
413
Flow Dividers
Flow Dividers
MODELS PD FLOW DIVIDERS and PDC FLOW DIVIDER/COMBINER
(Proportional Type) Order Code Bill of Material # Flow Rating Pressure Rating Port Size
1
07262001 07262004 07262003 07262002 07262005 07262019 07262023 07262006 07262011 07262010 07262009 07262012 07262008 07262007 00982928 07262026 00983042 07262025 07262038 07262040 08435001 08435002 08435020 08435011 08435017
5-20 GPM 5-20 GPM 5-20 GPM 5-20 GPM 5-20 GPM 5-20 GPM 5-20 GPM 20-35 GPM 20-35 GPM 20-35 GPM 20-35 GPM 20-35 GPM 20-35 GPM 20-35 GPM 5-20 GPM 5-20 GPM 5-20 GPM 5-20 GPM 20-35 GPM 20-35 GPM 5-20 GPM 20-35 GPM 5-20 GPM 5-20 GPM 20-35 GPM
2000 PSI 2000 PSI 2000 PSI 2000 PSI 2000 PSI 2000 PSI 2000 PSI 2000 PSI 2000 PSI 2000 PSI 2000 PSI 2000 PSI 2000 PSI 2000 PSI 2500 PSI 2500 PSI 2500 PSI 2500 PSI 2500 PSI 2500 PSI 2000 PSI 2000 PSI 2500 PSI 2500 PSI 2500 PSI
/2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT SAE 8
50/50 60/40 66w/d/33q/d 70/30 75/25 80/20 90/10 50/50 60/40 66w/d/33q/d 70/30 75/25 80/20 90/10 50/50 50/50 60/40 66w/d/33q/d 50/50 66w/d/33q/d 50/50 50/50 50/50 50/50 50/50
PD-50-80 PD-50-90 PD-75-50 PD-75-60 PD-75-67 PD-75-70 PD-75-75 PD-75-80 PD-75-90 PD-8-50 PD-10-50 PD-10-60 PD-10-67 PD-12-50 PD-12-67 PDC-50-50 PDC-75-50 PDC-8-50 PDC-10-50 PDC-12-50
SAE 10 SAE 12
60% 40% Spool Kit 60% 40% Spool Kit 70% 30% Spool Kit
414
Flow Dividers
Flow Dividers
MODEL CFD FLOW CONTROL
(Priority Type) Order Code Bill of Material # Port Sizes
1 1
Constant Flow
Relief Setting
CFD-50-1.5 CFD-50-1.5-HP CFD-50-1.5-HP-2000 CFD-50-1.5-NR CFD-50-2 CFD-50-2-HP CFD-50-2-NR CFD-50-3 CFD-50-3-HP CFD-50-3-NR CFD-50-4 CFD-50-4-HP CFD-50-4-HP-2000 CFD-50-4-NR CFD-50-5 CFD-50-5-HP CFD-50-5-NR CFD-50-6 CFD-50-6-HP CFD-50-6-NR CFD-50-7 CFD-50-7-NR CFD-50-8 CFD-50-8-HP CFD-50-9 CFD-50-9-HP CFD-50-10-NR CFD-50-10-HP CFD-75-1.5 CFD-75-1.5 NR CFD-75-2-HP CFD-75-2-NR CFD-75-3 CFD-75-3-HP CFD-75-4 CFD-75-4-HP CFD-75-4-HP-2000 CFD-75-4-NR CFD-75-5 CFD-75-5-HP CFD-75-5-NR CFD-75-6 CFD-75-6-HP CFD-75-6-NR
07261001 07261002 08650687 07261069 07261003 07261004 07261106 07261005 07261006 07261064 07261059 07261009 08650686 07261007 07261011 07261012 07261010 07261013 07261014 00983138 07261015 07261016 07261017 07261018 07261019 07261020 07261086 00983228 07261023 07261105 07261026 07261084 07261028 07261029 07261030 07261031 08650685 07261080 07261033 07261034 07261032 07261036 07261037 07261035
/2" NPT /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 1 /2" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT
1.5 GPM 1.5 GPM 1.5 GPM 1.5 GPM 2 GPM 2 GPM 2 GPM 3 GPM 3 GPM 3 GPM 4 GPM 4 GPM 4 GPM 4 GPM 5 GPM 5 GPM 5 GPM 6 GPM 6 GPM 6 GPM 7 GPM 7 GPM 8 GPM 8 GPM 9 GPM 9 GPM 10 GPM 10 GPM 1.5 GPM 1.5 GPM 2 GPM 2 GPM 3 GPM 3 GPM 4 GPM 4 GPM 4 GPM 4 GPM 5 GPM 5 GPM 5 GPM 6 GPM 6 GPM 6 GPM
500-1500 PSI 1500-2500 PSI 2000 PSI None 500-1500 PSI 1500-2500 PSI None 500-1500 PSI 1500-2500 PSI None 500-1500 PSI 1500-2500 PSI 2000 PSI None 500-1500 PSI 1500-2500 PSI None 500-1500 PSI 1500-2500 PSI None 500-1500 PSI None 500-1500 PSI 1500-2500 PSI 500-1500 PSI 1500-2500 PSI None 1500-2500 PSI 500-1500 PSI None 1500-2500 PSI None 500-1500 PSI 1500-2500 PSI 500-1500 PSI 1500-2500 PSI 2000 PSI None 500-1500 PSI 1500-2500 PSI None 500-1500 PSI 1500-2500 PSI None
Model CFD
415
Flow Dividers
Flow Dividers
MODEL CFD FLOW CONTROL, Continued from previous page
(Priority Type) Order Code Bill of Material # Port Size
3 3
Regulated Flow
Relief
Model CFD
CFD-75-7-HP CFD-75-8 CFD-75-8-HP CFD-75-8-HP-2000 CFD-75-8-NR CFD-75-9-HP CFD-75-10 CFD-75-10-HP CFD-75-10-NR CFD-10-1 CFD-10-1.5 CFD-10-1.5 HP CFD-10-1.5-HP-2000 CFD-10-1.5-NR CFD-10-2 CFD-10-2-NR CFD-10-3 CFD-10-3-NR CFD-10-4 CFD-10-4-HP CFD-10-4-HP-2000 CFD-10-5-HP CFD-10-5-NR CFD-10-6-HP CFD-10-9-HP CFD-10-10-HP
07261039 07261041 07261042 08650684 07261040 07261044 07261045 07261046 00983349 07261104 07261088 07261091 08650689 07261107 07261095 07261103 07261099 07261100 07261092 07261101 08650688 07261070 07261096 07261108 07261110 07261102
/4" NPT /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10
7 GPM 8 GPM 8 GPM 8 GPM 8 GPM 9 GPM 10 GPM 10 GPM 10 GPM 1 GPM 1.5 GPM 1.5 GPM 1.5 GPM 1.5 GPM 2 GPM 2 GPM 3 GPM 3 GPM 4 GPM 4 GPM 4 GPM 4 GPM 5 GPM 6 GPM 9 GPM 10 GPM
1500-2500 PSI 500-1500 PSI 1500-2500 PSI 2000 PSI None 1500-2500 PSI 500-1500 PSI 1500-2500 PSI None 500-1500 PSI 500-1500 PSI 1500-2500 PSI 2000 PSI None 500-1500 PSI None 500-1500 PSI None 500-1500 PSI 1500-2500 PSI 2000 PSI 1500-2500 PSI None 1500-2500 PSI 1500-2500 PSI 1500-2500 PSI
Port
Flow
1 3 3
SAE 10 SAE 10
08650262 Locknut Option, for Adjustable Flow Divider only 08650261 Relief Option for Model CFD, 1500-2500 PSI 08650260 Constant Flow Spool Kit (1.5 GPM) 08650259 Constant Flow Spool Kit (2 GPM) 08650258 Constant Flow Spool Kit (3 GPM) 08650256 Constant Flow Spool Kit (4 GPM) 08650257 Constant Flow Spool Kit (5 GPM)
Constant Flow Spool Kit (6 GPM) Constant Flow Spool Kit (7 GPM) Constant Flow Spool Kit (8 GPM) Constant Flow Spool Kit (9 GPM) Constant Flow Spool Kit (10 GPM)
416
Flow Dividers
Flow Dividers
MODEL DC25A FLOW CONTROL (Adjustable)
(Priority Type) Order Code Bill of Material # Port Size
1 1
Flow
/2" NPT /2" NPT 3 /4" NPT 3 /4" NPT SAE 10 SAE 10 SAE 12 SAE 12
Constant Flow
DC25N-50-2-NR DC25N-50-4-NR DC25N-50-5-NR DC25N-50-7-NR DC25N-75-1.5-NR DC25N-75-3-NR DC25N-75-6-NR DC25N-75-6-R DC25N-10-6-R DC25N-12-3-NR DC25N-12-4-NR DC25N-12-6-NR DC25N-12-6-R DC25N-12-12-NR *Relief valve set at 1500 PSI.
08387045 08387046 08387020 08387047 08387071 08387019 08387063 08387032 08387065 08387066 00983157 08387055 00983122 08387069
/2" NPT /2" NPT 1 /2" NPT 1 /2" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT 3 /4" NPT SAE 10 SAE 12 SAE 12 SAE 12 SAE 12 SAE 12
2 GPM 4 GPM 5 GPM 7 GPM 1.5 GPM 3 GPM 6 GPM 6 GPM 6 GPM 3 GPM 4 GPM 6 GPM 6 GPM 12 GPM
None None None None None None None 1500 PSI 1500 PSI None None None 1500 PSI None
K-OP-1 K-OP-1.5 K-OP-2 K-OP-3 K-OP-4 K-OP-5 K-OP-6 K-OP-7 K-OP-8 K-OP-9 K-OP-10 K-OP-12 K-OP-14 K-OP-16
08650363 08650362 08650361 08650360 08650359 08650358 08650357 08650356 08650355 08650354 08650353 08650352 08650351 08650350
1 GPM 1.5 GPM 2 GPM 3 GPM 4 GPM 5 GPM 6 GPM 7 GPM 8 GPM 9 GPM 10 GPM 12 GPM 14 GPM 16 GPM
417
QA
QD
Dual or Single
To 2500 PSI (172 bar) 40 GPM (151.4 litres/min)
The Models QA & QD are pressure compensated, flow regulators. They are designed to be used in applications such as spreaders where precise control of one or two functions may be required without regard to variations in work load. The valves are available with single or double controls, and can be supplied with or without a manual shut-off option. No relief, nonadjustable relief or adjustable relief options are available along with SAE or NPT porting A load sensing version of this valve is available.
Specifications
Capacity: . . . . . . . . . . . . . . . . . . . . . .40 GPM (151,4 litres/min) Maximum Operating Pressure: . . . . . . . . . . .2500 PSI (172 bar) Flow Adjustment Ranges: #1 (Spinner) . . . . . . . . . . . . .0 to 5 GPM (0 to 18,9 litres/min) 0 to 7 GPM (0 to 26,5 litres/min) 0 to 10 GPM (0 to 37,9 litres/min) #2 (Auger) . . . . . . . . . . . . .0 to 10 GPM (0 to 37,9 litres/min) 0 to 16 GPM (0 to 60,6 litres/min) 0 to 30 GPM (0 to 113,6 litres/min) Operating Temperature: Normal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180F (82C) Maximum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200F (93C) Material: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum
418
Flow Controls
MANUAL SPREADER VALVES
Description Bill of Material # Double Double w/ w/o Man. Man. Shut. Shut. Single w/ Man. Shut. Single w/o Man. Shut. Double w/LS & Man. Shut. SOL OP (12V) Shut.
First Adjustment Second Adjustment
0-5
QAA-12-A16-NA QAB-12-A00-B16-AR-01 QAB-75-A00-B10-NA QAB-75-A00-B16-AR-01 QAB-75-A00-B16-NA QAB-75-A00-B30-AR-01 QAB-75-A00-B30-NA QDA-12-A07-B16-NR QDA-12-A10-B16-NR QDA-75-A10-B30-NA QDB-12-A05-B10-NR QDB-12-A05-B16-AR-01 QDB-12-A07-B16-AR-01 QDB-12-A07-B16-NA QDB-12-A10-B10-AR QDB-12-A10-B16-AR-01 QDB-12-A10-B20-AR QDB-12-A10-B30-AR-01 QDB-12-A10-B30-NA QDB-75-A05-B10-AR-01 QDB-75-A05-B10-NA QDB-75-A05-B16-AR-01 QDB-75-A05-B16-NA QDB-75-A05-B30-AR-01 QDB-75-A07-B16-AR-01 QDB-75-A07-B16-NA QDB-75-A07-B16-NR QDB-75-A10-B16-AR-01 QDB-75-A10-B30-AR-01 QDB-75-A10-B30-NA QDB-75-A10-B30-NR QDL-12-A05-B10-NR QDL-12-A05-B16-NR QDL-12-A07-B16-NR QDL-12-A10-B16-NR QDL-12-A10-B30-NR QDL-75-A07-B16-NR QDL-75-A10-B30-NR QDA-12-A05-B10-NR QDS-12-A07-B16-AR-12 QDS-12-A10-B16-AR-12 QDS-12-A10-B30-AR-12 QDS-75-A07-B16-AR-12 QDS-75-A05-B16-NA-12 QDS-75-A07-B16-NA-12 QDS-75-A10-B30-AR-12 QDS-75-A10-B30-NA-12
97929-05 97920-02 97921-04 97921-02 97921-05 97921-03 97921-06 97922-23 97922-26 97923-18 97919-25 97919-02 97919-05 97919-14 97919-07 97919-08 97919-21 97919-09 97919-18 97917-01 97917-10 97917-02 97917-11 97917-03 97917-05 97917-14 97917-23 97917-08 97917-09 97917-18 97917-27 97918-01 97918-02 97918-05 97918-08 97918-09 97916-05 97916-09 97922-19 97932-01 97932-02 97932-03 97931-01 97931-03 97931-04 97931-02 97931-05
419
CUSHION VALVES
MODEL DXV
Ball/Spring Relief Valve
Features
MODEL DWV
Uses Model WH Relief Cartridge Differential Poppet Type
Non-adjustable Type Reliefs can be adjusted by adding or subtracting shims. Adjustable Relief Available for Model DWV. Factory Pre-Set to Customers Specific Pressure Requirements High-Tensile, Cast Iron Body.
Specifications
DXV DWV Capacity (nominal): . . . . . . . . . . . . . . . . . .10 GPM 30 GPM (37 litres/min) (113 litres/min) Minimum Operating Pressure: . . . . . . . . . . . .5 PSI 300 PSI (0,3 bar) (20 bar) Maximum Operating Pressure: . . . . . . . . .2500 PSI 3000 PSI (172 bar) (207 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . . .4 lbs 5 lbs (1,8 kg) (2,3 kg)
420
Cushion Valves
Cushion Valves
MODEL DXV CUSHION VALVES
Ball/Spring Type Dual Crossover Relief
Pressure Range, PSI* Model Bill of Material # Port Size
3
50400
401750
751900
9011300
13011450
14511800
18012000
20013000
30013500
DXV-38 50-400 PSI DXV-38 401-750 PSI DXV-38 751-900 PSI DXV-38 901-1300 PSI DXV-38 1301-1450 PSI DXV-38 1451-1800 PSI DXV-38 1801-2000 PSI DXV-38 2001-3000 PSI DXV-50 50-400 PSI DXV-50 401-750 PSI DXV-50 751-900 PSI DXV-50 901-1300 PSI DXV-50 1301-1450 PSI DXV-50 1451-1800 PSI DXV-50 1801-2000 PSI DXV-50 2001-3000 PSI DXV-50 3001-3500 PSI DXV-75 901-1300 PSI DXV-75 1451-1800 PSI DXV-75 1801-2000 PSI DXV-75 2001-3000 PSI DXV-75-1300 DXV-75-1800 DXV-75-2000 DXV-8 401-750 PSI DXV-8 901-1300 PSI DXV-8 1451-1800 PSI DXV-8 1801-2000 PSI DXV-8 2001-3000 PSI DXV-10 401-750 PSI DXV-10 751-900 PSI DXV-10 901-1300 DXV-10 1451-1800 PSI DXV-10 1801-2000 PSI DXV-10 2001-3000 PSI DXV-10-2500
07595029 07595005 07595094 07595015 07595020 07595006 07595021 07595022 07595017 07595011 07595010 07595003 07595028 07595002 07595009 07595004 07595025 07595008 07595019 07595048 07595036 08650408 08650409 08650410 07595023 07595026 07595054 07595024 07595016 07595082 07595070 07595074 07595047 07595030 07595103 08650404
/8" NPT /8" NPT /8" NPT /8" NPT /8" NPT /8" NPT /8" NPT /8" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT SAE 8 SAE 8 SAE 8 SAE 8 SAE 8
Model DXV
*Relief valves set at the high setting within the range selected. (Exception: Order Code DXV-10-2500 is set at 2500 PSI.)
421
Cushion Valves
Cushion Valves
MODEL DWV CUSHION VALVES
(Differential Type Double Relief) Model and Pressure Range* or Pressure Setting Bill of Material # Port Size Adjustment Option Stainless Steel Spring
1 03744008 /2" NPT 1 DWV-50 1250-1749 PSI 03744009 /2" NPT 1 DWV-50 1750-1999 PSI 03744010 /2" NPT 1 DWV-50 2000-2599 PSI 03744011 /2" NPT 1 DWV-50-1350 08650411 /2" NPT 1 DWV-50-1750 08650412 /2" NPT 1 DWV-50-2000 08650413 /2" NPT 1 DWV-50-A 500-1249 PSI 03744021 /2" NPT 1 DWV-50-A 1250-1749 PSI 03744028 /2" NPT 1 DWV-50-A 1750-1999 PSI 03744037 /2" NPT 1 DWV-50-A 2001-2600 PSI 03744045 /2" NPT 1 DWV-50-SS 1750-1999 PSI 03744051 /2" NPT 3 DWV-75 500-1249 PSI 03744003 /4" NPT 3 DWV-75 1250-1749 PSI 03744004 /4" NPT 3 DWV-75 1750-1999 PSI 03744005 /4" NPT 3 DWV-75 2000-2599 PSI 03744006 /4" NPT 3 DWV-75 2601-3000 PSI 03744061 /4" NPT 3 DWV-75-1350 08650414 /4" NPT 3 DWV-75-1750 08650415 /4" NPT 3 DWV-75-2000 08650416 /4" NPT 3 DWV-75-A 1250-1750 PSI 03744015 /4" NPT 3 DWV-75-A 1751-2000 PSI 03744034 /4" NPT 3 DWV-75-A 2001-2600 PSI 03744039 /4" NPT 3 DWV-75-A 2001-2600 PSI 03744016 /4" NPT DWV-8 500-1249 PSI 03744029 SAE 8 DWV-8 1750-1999 PSI 03744001 SAE 8 DWV-8 2000-2599 PSI 03744002 SAE 8 DWV-8-SS 1250-1749 PSI 03744060 SAE 8 DWV-8-A 2001-2600 PSI 03744057 SAE 8 DWV-10 1750-1999 PSI 03744022 SAE 10 DWV-10 2000-2599 PSI 03744040 SAE 10 DWV-10-A 1351-1750 PSI 03744035 SAE 10 DWV-10-A 2001-2600 PSI 03744053 SAE 10 DWV-12 1750-1999 PSI 03744012 SAE 12 DWV-12 2000-2599 PSI 03744047 SAE 12 DWV-12 2500-3000 PSI 03744059 SAE 12 DWV-12 500/2000 PSI 00983060 SAE 12 DWV-12-A 2000 PSI 03744063 SAE 12 DWV-12-A 2001-2600 PSI 03744032 SAE 12 *Relief Valves set @ the high setting within the pressure range unless specified.
Model DWV
Shim Shim Shim Shim Shim Shim Shim Screw Screw Screw Screw Shim Shim Shim Shim Shim Shim Shim Shim Shim Screw Screw Screw Screw Shim Shim Shim Screw Screw Shim Shim Screw Screw Shim Shim Shim Shim Screw Screw
K-DWV-10 K-DWV-50
08650238 08650239
DWV Housing SAE 10 for WH Relief Valve DWV Housing /2" NPT for WH Relief Valve
1
K-DWV-75 08650240 DWV Housing 3/4" NPT for WH Relief Valve NOTE: Do not use Model RP51 relief cartridge in DWV housings.
422
RELIEF VALVES
Models JT and JL Relief Valves are used to limit the maximum pressure which can be applied to the portion of the hydraulic circuit to which they are connected. They may be used as a system relief when installed between the pump and the first of a series of separate control valves or as a line relief by installing between a control valve port and actuator. Adjustable valves can be readily reset and feature a jam nut to lock the new setting. Shim-set valves are best left unchanged after installation due to manufacturing tolerances.
MODEL MODEL
JT
JL
P P T
JL
MODEL JT
MODEL JL
Features
Two Housings Available For Tee-Mounting or In-Line Mounting. Adjustable and Non-Adjustable Models Available. Compacted Graphite Bodies. Replaceable, Hardened Seat. JT
P
Specifications
PERFORMANCE DATA
[litres/min] 18,9 37,9 56,8 75,7 18,9 [litres/min] 37,9 56,8 75,7 18,9
Capacity (nominal) Adjustable: . . . . . . . . . .Up to 20 GPM (75 litres/min) Maximum Operating Pressure: . . . . . . . . . . . . . . . . . .2500 PSI (172 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . . . . . .Approx. 21/2 lbs. (1,1 kg)
[litres/min] 37,9 56,8 75,7
600
41
1500
103
3000
207
500
34
1250
86
2500
172
400 PSI
27 (bar) PSI
1000
69 [bar] PSI
2000
138
300
20
750
51
1500
103
200
13
500
34
1000
69
100
6,9
250
17
500
34
10 GPM
15
20
10 GPM
15
20
10 GPM
15
20
JT (LP) Relief With 953-001 Spring 145-400 PSI [10-27,6 bar]. Crack.
[litres/min] 18,9 37,9 56,8 75,7
400
27
2000
138
2500
172
[bar]
[bar]
200
13
1000
69
2000
138
100
6,9
500
34
1750
120
10 GPM
15
20
10 GPM
15
20
10 GPM
15
20
JT-N (LP) Relief With 987-011 Spring 50-200 PSI [3,4-13,8 bar]. Crack
[bar]
300 PSI
20
1500 PSI
103
2250 PSI
155
423
RELIEF VALVES
MODELS
WJT/RPJT and WJL/RPJL Relief Valves are used for limiting the maximum pressure which can be applied to the portion of the hydraulic circuit to which it is connected. These valves have housings constructed of high strength compacted graphite cast iron. Differential Poppet Reliefs, Model WJ, allow pressure settings up to 3000 PSI [207 bar]. Pilot-Operated Reliefs, Model RP, allow pressure settings up to 5000 PSI [345 bar]. Adjustable valves can be readily reset and feature a jamnut to lock the new setting. Shim-set valves are best left unchanged after installation, due to manufacturing tolerances.
WJT/RPJT WJL/RPJL
Features
Compact, Low Profile Design. Compacted Graphite Bodies. All Units Are Factory Pre-set
Model RPJT Model WJL
Specifications
Capacity (nominal): . . . . . . . . . . . . . . . . . . .Up to 25 GPM (94 litres/min) Maximum Operating Pressure: . . . . . . . . . . . . . .(WJ) 3000 PSI (207 bar) (RPJ) 5000 PSI (345 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 lbs. (1,4 kg)
Model WJT
Model RPJL
P P
[litres/min] 18,9 3500 3000 2500 PSI 2000 1500 1000 500 0 0 5 10 15 GPM 20 25 1870 SPRING 7078 SPRING 7638 SPRING 1869 SPRING 7497 SPRING 37,9 56,8 75,7 94,6 241 207 172 [bar] 138 103 69 34
T
WJL/RPJL Adjustable
WJT/RPJT SHIM-SET
PERFORMANCE DATA
[litres/min] 37,9 5000 4500 75,7 113,6
151,4
189,3 345 310 276 [bar] 241 207 172 138 103 69 34
424
RELIEF VALVES
These Relief Valves have been designed to give long life and smooth performance. They afford over-load protection for hydraulic circuits and for structural members of tools and machines. RPL Pilot Relief Valves and KCL Ball/Spring Relief Valves are available as adjustable or non-adjustable. An optional gage port is available on Model RPL.
MODEL MODEL
KL
RPL
MODEL KCL-N
Features
In-Line Mounting. Adjustable. Compacted Graphite Bodies. Smooth and Quiet Operation. Optional Gauge Port.
T P
Specifications
RPL KL Capacity (nominal): . . . . . . . . . . . . .Up to 60 GPM Up to 38 GPM (227 litres/min) (143 litres/min) Maximum Operating Pressure: . . . . .500-5000 PSI 300-2000 PSI (34-345 bar) (20-138 bar) Shipping Weight: . . . . . . . . . . . . . . . . . . . . . .6 lbs 63/4 lbs (2,7 kg) (3,1 kg)
MODEL RPL-A
PERFORMANCE DATA
[litres/min] 37,8 75,7 113,5 151,4
155 138
3500 120 [bar] 103 86 69 1000 51 500 0 PSI 3000 2500 2000 1500
425
Relief Valves
Relief Valves
MODEL JT RELIEF VALVES
(Ball/Spring, Tee Mounted Type)
Bill of Material # Port Size
1
Order Code
Adjustment Option
11904009 11905008 11905009 11905010 11904010 11904008 11906008 11906009 11904015 11904014 11904001 11905006
/2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT 8 SAE 8 SAE
Screw Handle Handle Handle Screw Screw Shim Shim Screw Screw Handle Screw
JT-50-HP JT-50-LP JT-50-N 1301-1800 PSI JTR-50-N-HP-1801-2500 PSI JT-8 JT-8-LP 50-250 PSI JT-10 290-1200 PSI JT-10-A-HP 1201-2500 PSI
10 SAE 10 SAE
*Relief valves set at the high setting within the range selected.
JL-10-HP 1201-2500 PSI JL-50 290-1200 PSI JL-50-A 290-1200 PSI JL-50-A-HP 1201-2500 PSI JL-50-HP 1201-2500 PSI
Model JL
11893007 11893002 12057002 12057001 11893003 08650474 11893001 12058001 12058002 08650472 11893005 12057003 12057004 11893006 11893004 12058003 08650477 08650478
SAE 10
1
Screw Screw Handle Handle Screw Screw Screw Shim Shim Screw Screw Handle Handle Screw Screw Shim Screw Screw
/2" NPT
/2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT
JL-50-HP-2000 JL-50-LP 145-400 PSI JL-50-N 301-1800 PSI JL-50-N-LP 50-400 PSI JL-50-1200 JL-75 290-1200 PSI JL-75-A 290-1200 PSI JL-75-A-HP 1201-2500 PSI JL-75-HP 1201-2500 PSI JL-75-LP 145-400 PSI JL-75-N-LP 145-400 PSI JL-75-1200 JL-75-2000-HP
*Relief valves set at the high setting within the range selected. (Exception: order code JT-50-2000-HP is set at 2000 PSI)
426
Relief Valves
Relief Valves
Handle
Order Code Bill of Material # Description
K-JA
08650246
Model
Adjustment Option
300499
20002599
26003000
WJT-38 WJT-50 WJT-50-N WJT-50 WJT-50 WJT-50 WJT-50 WJT-50 WJT-50-A WJT-8 WJT-8-A WJT-10 WJT-10 WJT-10 WJT-10 WJT-10A WJT-10-A
11908029 11908011 11903010 11908012 11908013 11908014 11908015 11908010 11902012 11908025 11902015 11908001 11908004 11560341 11908005 11902004 11902005
/8" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT SAE 8 SAE 8
Shim Shim Shim Shim** Shim Shim Shim Screw Screw Shim Screw Shim Shim Shim Shim Screw Screw
Model WJT
*Relief valves set at the high setting within the range selected. **Includes lockwire.
427
Relief Valves
Relief Valves
MODEL WJL RELIEF VALVES
(Differential, Inline Mounted type)
Model Bill of Material # Port Size
1
Adjustment Option
300499
20002599
26003000
11414001 11414002 11414003 11414004 11414005 12055002 12055007 00983117 12056006 11414007 11414008 11414009 11414010 11414011 12055005 12055004 12056004 12056005 12056007 12056003 11414013 11414014 11414015 11414016 11414017 12055003 12055006 00983029 12056001 12056002 11414023 11414022
/2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /2" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT /4" NPT
Shim Shim Shim Shim Shim Screw Screw Screw Shim** Shim Shim Shim Shim Shim Screw Screw Shim** Shim** Shim** Shim** Shim Shim Shim Shim Shim Screw Screw Screw Shim** Shim** Shim Shim
WJL-50 WJL-50-A WJL-50-A WJL-50-A WJL-50-N WJL-75 WJL-75 WJL-75 WJL-75 WJL-75 WJL-75-A WJL-75-A WJL-75-N WJL-75-N WJL-75-N WJL-75-N WJL-10 WJL-10 WJL-10 WJL-10 WJL-10 WJL-10-A WJL-10-A WJL-10-A WJL-10-N WJL-10-N WJL-12 WJL-12
SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 10 SAE 12 SAE 12
*Relief valves set at the high setting within the range selected **Includes lockwire
428
Relief Valves
Relief Valves
MODEL RPJT RELIEF VALVES
Pilot Operated
Order Code Bill of Material # Type Port Size Adjustment Option Pressure Range*
RPJT-10-A
11907001
Pilot Pilot
SAE 10 SAE 8
Adjustable Adjustable
RPJT-8-A 11907003 *Relief valves set @ 3500 PSI. Consult factory for applications over 3500 PSI.
Differential Poppet Differential Poppet Differential Poppet Differential Poppet Differential Poppet Pilot
NOTE: All above Relief Valves have stainless steel springs. WH Relief Valves are shim set, RP51A Relief Valves are screw adjustable. All Relief Valves set at crack pressure of 1 GPM flow.
WJT Housing with 1/2" NPT Ports WJL Housing with /2" NPT Ports WJL Housing with 3/4" NPT Ports WJL Housing with SAE 10 Ports WJL Housing with SAE 10 Ports
1
Order Code
Bill of Material #
Description
K-WH-A
08650381
429
Relief Valves
Relief Valves
MODEL RPL RELIEF VALVES
(Inline Mounted)
Order Code Bill of Material # Type Port Size
3
Adjustment Option
Pressure Range*
/ " NPT
4
500-3500 PSI 500-3500 PSI 500-3500 PSI 500-3500 PSI 500-3500 PSI 500-3500 PSI 500-3500 PSI 500-3500 PSI 500-3500 PSI
/4" NPT
1" NPT 1" NPT 1" NPT SAE 16 SAE 16 SAE 16 SAE 16
RPL-16-N-G 11370002 Pilot *Relief valve set at 3500 PSI. Consult factory for applications over 3500 PSI.
NOTE: KC and RP60A Relief Valves are screw adjustable. Set at crack pressure of 1 GPM flow.
Relief Valve Housing w/SAE 16 Ports Relief Valve Housing w/3/4" NPT Ports Relief Valve Housing w/1" NPT Ports
430